PACKAGE CONTENTS

PART| DESCRIPTION| #4968563
QUANTITY| #4968570
QUANTITY
---|---|---|---
A| Fixture| 1| 1
B| Mounting Plate (preassembled)| 1| 1
C| Screw (preassembled)| 2| 2
D| Socket Ring (preassembled)| 3| 4
E| Shade| 3| 4

allen plus roth VB220 3MBK VB220 4MBK Vanity Light -
fig

HARDWARE CONTENTS (shown actual size)

SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS.
DANGER

  • For your protection and safety, carefully read and understand the information provided in this manual completely before attempting to assemble, install or operate this  product. Failure to do so could lead to electrical shock, fire or other injuries that could be hazardous or even fatal.
  • DO NOT connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use a fixture in a two-wire system that is not  grounded. Installing a fixture into an electrical system not having a proper grounding means could cause metal parts of the fixture to carry electrical currents if any of the fixture wires, wire connections or splices were to become broken, cut or loose during the mounting or normal operation of the fixture. Under this condition, anyone  coming in contact with the fixture would be subject to electrical shock, which could cause serious injury or death.
  • DO NOT connect the bare or green insulation fixture ground wire to the black (HOT) current-carrying wire or the white NEUTRAL house wire. Connection of the  bare or green fixture ground wire to the black or white house wires may cause metal parts of the fixture to carry electrical currents. Under this condition anyone coming  in contact with the fixture will receive electrical shock, which could cause serious injury or death.
  • DO NOT damage or cut the wire insulation (covering) during installation of fixture. DO NOT permit wires to contact any surface having a sharp edge. To do so may  damage or cut the wire insulation, which could cause serious injury or death from electrical shock.

WARNING

  • All electrical connections must be in agreement with local codes and ordinances, the National Electric Code (NEC) and ANSI/NFPA 70-1999. Contact your municipal  building department to learn about your local codes, permits and/or inspections. Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F (60 °C). Consult a qualified electrician before installation.
  • To avoid personal injury, the use of gloves may be necessary while handling fixture parts with sharp edges.
  • DO NOT suspend any fixture by the house wires. A fixture must always be mounted directly to an outlet box or to a mounting strap that is first attached to the outlet  box. Wire connectors will not support the weight of a fixture. Suspending a fixture by the house wires and wire connectors will result in the fixture falling, with the  possibility of personal injury and the danger of electrical shock or fire.
  • To reduce the risk of fire, electrical shock or personal injury, wire connectors provided with this light fixture are designed to accept only one 12-gauge house wire and  two lead wires from the light fixture. If your house wire is larger than 12-gauge or there is more than one house wire to connect to the corresponding fixture lead wires,  consult an electrician for the proper size wire connectors to use.

CAUTION

  • TURN OFF ELECTRICITY at main fuse box (or circuit breaker box) before beginning installation by removing the fuse (or switching the circuit breaker off).
  • If you are not sure the lighting system has a grounding means, DO NOT attempt to install this fixture. Contact a qualified, licensed electrician for information regarding  the proper grounding methods as required by the local electrical code in your area.
  • All fixtures must be mounted to an outlet box that is supported by the building structure.
  • DO NOT use bulbs having a wattage greater than the maximum value stated on the fixture. The use of bulbs with higher wattage than specified will increase  temperatures and risk of fire.
  • If a dimmer control switch is used with this fixture, obtain professional advice to determine the correct type to use as well as the electrical rating required.

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.

Estimated Assembly Time: 30 minutes
Tools Required for Assembly (not included): Flathead Screwdriver, Phillips Screwdriver, Wire Strippers, Pliers, Wire Cutters, Safety Glasses, Stepladder, Electrical Tape Helpful Tools (not included): A/C Tester Light, Do-It-Yourself Guide, Soft Cloth, Level

ASSEMBLY INSTRUCTIONS

  1. Turn off circuit breakers and wall switch to the fixture supply line leads.
    DANGER: Failure to disconnect power supply prior to installation may result in serious injury or death.

  2. Remove existing fixture and disconnect all electrical wiring.

  3. Remove mounting plate (B) from fixture (A) by removing mounting plate screws (C) from the edges of the fixture (A).
    Save mounting plate screws (C) for later use.

  4. Attach mounting plate (B) to outlet box (not included) using existing washers and outlet box screws or the machine screws (BB).
    NOTE: If the outlet box screws required for your outlet box are of a different size than the machine screws (BB), consult a licensed electrician before proceeding.  Tighten machine screws (BB) to secure mounting plate (B). CAUTION: The fixture must be mounted to an outlet box that is supported by the building structure. Plastic outlet boxes are not recommended.
    Hardware Usedallen plus roth VB220 3MBK VB220 4MBK Vanity Light - fig
6

  5. Unwrap BARE fixture wire from BLACK and WHITE fixture wires. Prepare wires by stripping 3/4 in. of insulation from wire ends using wire strippers (not included).  Connect WHITE wire from fixture (A) to WHITE wire from outlet box using existing wire connector or wire connector (AA). Connect BL ACK wire from fixture (A)  to BLACK wire from outlet box using existing wire connector or wire connector (AA). Connect BARE/GREEN ground wire from outlet box to BARE ground wire  from fixture (A) with wire connector (AA). NOTE: Screw wire connectors (AA) on in a clockwise direction.
    WARNING: Never connect ground wire to WHITE or BLACK power supply wires.
    WARNING: To reduce the risk of fire, electrical shock or personal injury, wire connectors (AA) are designed to accept only one 12-gauge house wire and two lead wires  from the light fixture. If your house wire is larger than 12-gauge or there is more than one house wire to connect to the corresponding fixture lead wires, consult an  electrician for the proper size wire connectors to use.
    Hardware Usedallen plus roth VB220 3MBK VB220 4MBK Vanity Light - fig
8

  6. Wrap electrical tape (not included) around each individual wire connector (AA) down to the wire. Push wire connectors (AA) gently back into outlet box. Carefully push excess wiring into outlet box.
    WARNING: Make sure no bare wire or wire strands are visible after making connections.

  7. Attach fixture (A) to mounting plate (B) using the mounting plate screws (C) previously removed (Step 3, Page 5).
    NOTE: Before tightening mounting plate screws (C) completely, use level (not included) to check fixture (A) — adjust if necessary.
    NOTE: Fixture (A) can be installed with the sockets facing either up or down.

  8. Remove socket ring (D) from socket of fixture (A).
    Attach shade (E) to socket, securing with socket ring (D).
    Repeat for remaining sockets.
    WARNING: Do not overtighten socket ring (D) as shade may crack or break.

  9. Install standard-base bulbs (not included). Use 60-watt max. incandescent bulbs or CFL/LED equivalent.
    WARNING: When replacing bulb(s), please allow bulbs and fixture to cool down before touching.
    Restore power and test fixture (A).
    If lights do not function, please refer to TROUBLESHOOTING.

CARE AND MAINTENANCE

  • Shut off main power supply. Wipe with soft cloth or use window cleaner. Do not use an abrasive cleaner.

TROUBLESHOOTING

WARNING: Before beginning work, shut off the power supply to avoid electrical shock.

  PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Bulb will not light. 1. Bulb is burned out.

2. Power is OFF.
3. Faulty connection.| 1. Replace light bulb.
2. Make sure power supply is ON.
3. Check wiring and all connections.
Fuse blows out or circuit breaker trips.| 1. Crossed wires.
2. Power wire is grounding out.| 1. Check wiring.
2. Check all connections.

WARRANTY
The distributor warrants all of its lighting fixtures against defects in materials and workmanship for one (1) year from the date of purchase. If within this period the product is  found to be defective, take a copy of the bill of sale as a proof of purchase and the product in its original carton to the place of purchase. The distributor will, at its option,  repair, replace or refund the purchase price to the consumer. All costs of installation and removal of the fixture is the responsibility of the consumer. This warranty does not  cover fixtures becoming defective due to misuse, accidental damage or improper handling and/or installation and specifically excludes liability for direct, incidental or  consequential damages. As some states do not allow exclusions of limitations on an implied warranty, the above exclusion and limitation may not apply. This warranty gives  you specific rights and you may also have other rights which may vary from state to state.

ALLEN+ROTH and logo design are trademarks or registered trademarks of LF, LLC. All rights reserved.

ITEM #4968563
4968570
VANITY LIGHT
MODEL #VB220-3MBK
VB220-4MBK
Purchase Date
ATTACH YOUR RECEIPT HERE

Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 866-439-9800, 8 a.m. – 8 p.m., EST, Monday – Sunday. You  could also contact us at partsplus@lowes.com.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals