PHILIPS BY120P Coreline LED High Bay Instruction Manual
- June 9, 2024
- Philips
Table of Contents
PHILIPS BY120P Coreline LED High Bay
Instruction
Description
|
System lumen(lm)
|
CCT(K)
|
Optics
|
Pmax (W)
| Dimension D| in H|
mm
| |
light source energy efficiencyclass
---|---|---|---|---|---|---|---|---|---
BY120P G5 LED105S PSU| 10500| | | 67| 290| 90| 1.9| C
BY120P G5 LED150S PSU| 15000| | | 95| 290| 90| 1.9| C
BY121P G5 LED200S PSU| 20000| | | 126| 330| 99| 2.4| C
BY122P G5 LED250S PSU| 25000| | | 157| 393| 99| 4| C
BY122P G5 LED300S PSU| 30000| 4000/6500| WB/NB| 192| 393| 99| 4| C
BY121P G5 LED105S PSD| 10500| | | 72| 330| 99| 3.2| C
BY121P G5 LED150S PSD| 15000| | | 102| 330| 99| 3.2| C
BY121P G5 LED200S PSD| 20000| | | 134| 330| 99| 3.2| C
BY122P G5 LED250S PSD| 25000| | | 168| 393| 99| 5.5| C
BY122P G5 LED300S PSD| 30000| | | 205| 393| 99| 5.5| C
- The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
- Turn power off before inspection, installation or removal.
- Before using, external earthing is must required. Earthing is also must required in its whole life.
- The Luminaire must be used within the applicable product specifications, installation instructions and environmental conditions for storage & operations according to application guidelines provided by Signify for product Warranty to be valid.
- The corrosive atmosphere or hazardous materials such as sulfur, chlorine, phthalate, etc must be avoided during the use and storage.
- The manufacturer will not take responsibility caused by improper use or self-modifications of the product.
- If the external flexible cable or cord of this luminaire is damaged. It shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
- For Indoor use only. This product is not suitable for cold storage areas where obvious temperature gradients are present, such as ventilation opening, door, etc.
- Installer needs to arrange Chain / Pipe for mounting. The default product is supplied with a mounting hook
- The height between luminous surface and ground suggested be more than 5m; the height between bottom of luminaire and mounting surface must be more than 0.3m.
- Similar installation or application like flood and tunnel luminaires are NOT allowed.
- Not suitable for use in harsh vibration and often causing vibration or swinging environment. Also, not suitable for area prone to hurricane and extreme winds.
- If customer require the luminous surface levelness<1°,the pipe mounting method is recommended, and suggest to use gradienter to precisely measure and adjust.
- Periodic cleaning of the luminaire optical lens cover will ensure maximum optical efficiency.Luminaire shall be cleaned with a dry soft cloth only.
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
- The control gear contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
- This product contains a light source of energy efficiency class: C.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Disconnect before servicing
Luminaire has basic insulation between Low Voltage supply and control
conductors.
Storage, installation, use, operation and maintenance of the products needs to
be performed exactly according the instructions in this manual and/or other
instructions as may be provided by us to guarantee safe use of the product
over its entire lifetime. Failure to adhere to these instructions will
invalidate your entitlement to warranty. Bolts with indication of torque
strength on the drawing need to be tightened using a calibrated torque wrench.
Pre-assembledbolts need to be retightened again to the required torque
specification to assure maximum strength over lifetime.
This product contains a light source of energy efficiency class: see table or
label.
References
Read User Manual Online (PDF format)