PHILIPS WL060V Ledinaire Wall Mount User Guide

June 9, 2024
Philips

WL060V Ledinaire Wall Mount
User Guide

WL060V Ledinaire Wall Mount

| System lumen {Lm)| PW)| Light source of energy efficiency class| A(mm)| B(mm)| c(mm)|
---|---|---|---|---|---|---|---
WLO6OV LED11S| 1100| 11| D| 285| 88| 200| 0.5
WLO6O0V LED17S| 1700| 17| E| 345| 97| 240| 0.7
WLO6OV LED17S MDU| 1700| 19| E| 0.7

PHILIPS WL060V Ledinaire Wall Mount - 2 ATTENTION FOR HANDLING
ELECTROSTATIC SENSITIVE

  • The luminaire shail be Installed by a qualified electrician and wired In accordance with the latest IEE electrical regulations or the national requirements.
  • This luminaire Is not suitable for use as emergency lighting.
  • Light source contained In this luminaire shall only be replaced by the manufacturer or his service agent ora similar qualified person.

PHILIPS WL060V Ledinaire Wall Mount - icon2

Inrush current

PHILIPS WL060V Ledinaire Wall Mount - 3

| LED1 1S| LED17S
---|---|---
| Electrical characteristics
Imax (A)| 10| 13
Tref (ps)| 2.| 2.
MCB| Luminaires Max.
B-10 A| 22| 22
B-13 A| 28| 28
B-16 A| 35| 35
C-10 A| 36| 36
C-13 A| 46| 46
C-16 A| 57| 57

PHILIPS WL060V Ledinaire Wall Mount - 4

HF Motion Sensor (For WLO60V LED17S MOU only)
By selecting the combination on the DIP switch, sensor data can be precisely set for each specific application.

PHILIPS WL060V Ledinaire Wall Mount - 5

| 1|
---|---|---
I| ON| 100%
II| –| 50%

Detection area, (default 100%) show pattems,
Detection area can be reduced to 50% by selecting the combination on the DIP switches to fit precise applications

| 2| 3|
---|---|---|---
I| ON| ON| 5S
II| ON| –| 1min
111| –| ON| 5min
IV| –| –| 10min

Hold time. (default 5 min.)
Refers to the time period the |uminaire remains at 100% Illumination after no mation detected

| 4| 5|
---|---|---|---
I| ON| ON| 5Lux
II| ON| –| 25Lux
III| –| ON| 50Lux
IV| _| –| Disable*

Daylight sensor. (default 25 lux.)
The sensor can be set to switch on the luminaire below certain light levels (5/25/50 l u x ) . When it is set to Disable mode, daylight sensor will switch on the luminaire when motion is detected re gardless the ambient light level

| 8|
---|---|---
1| ON| 10%
II| –| 25%

Stand-by dimming level, (default 25%)
Dimming level when there is no motion after the hold time to save energy.

| 6| 7|
---|---|---|---
I| ON| ON| OS
II| ON| –| 1min
III| –| ON| 10min
IV| –| –| +00

Stand-by period. (default 10 min.)
Time period of keeping dimmed levels before the luminaire is completely switched off when there is no motion.When itis set to ‘®’ mode, dimmed light level is maintained
until motion is detected.
Detection arsa ( radiation pattern)
Ceiling mounting

Notes:

  1. The Ledinaire Wall-mounted needs to be Installed side-by-side In the same direction. The distance between each of the luminaires should be kept at least 3m t o avold mutual Interference.

  2. Please pay attention to the Installation environment:
    2 . 1 . Avald high-density objects such as: metal, glass, concrete walls, etc., within the sensor detection area.
    2 . 2 . Avold moving signals within the sensor detection area such as: fan, DC motor, sewer pipe, alr outlet, heavy rainfall, motlon behind athin wall etc. This to avold false triggers of the sensor.
    2.3 Avold shock & vibration In the environment of the application.

  3. In order to reach the common sensor distance the object move speed should be less than 1m/S. If an object moves with speed higher than 1m/s the detection distance will decrease.

  4. I t ls advised not to Install a luminalre on a wooden surface. I n case It must be Installed on a wooden surface, the wood thickness must be more than 15¢em.

  5. To avold smaller detection range or abnormal operation, the Ledinalre Wall-mounted should not be Installed In close distance to large areas of metal and glass {separation distance at least 1m).

Please reduce detection area setting or contact Signify to confirm the situation once the Ledinalre Wall- mounted works falls.
Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
Disconnecthelors evicing
Luminaire hae basic ingulation between Low Voltage supply and control conductors
Thelight source contalned inthis luminal and the extomal flexible cab Ohad be renloved by the wis sarvee agent ble shall only be replaced by the manufacturer or his service agent or a similar qualified person.
SR compatibility – For SR-based luminaires only SR-Certified components/sensors are to be used (see also:
http://www.lighting.philips.co.uk/oem-emea/products/driving-connected- lighting). The functional compatibility of two (SR-certified) components/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based luminaire, is to be released by the master component/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non-compliance for which Signify cannot take any responsibility.

WEEE Statement

Please inform yourself about the local waste disposal, separation and collection system for electrical and electronic products and packaging. Please act according to your local rules and do not dispose your old product and packaging with your normal household waste. The correct disposal of the packaging, your product and/or batteries will help prevent potential negative consequences for the environment and human health. Batteries should be disposed separately from the municipal waste stream via designated collection facilities. When disposing a product that contains non-user replaceable batteries, the non-user replaceable batteries shall be removed by a professional.
The light source and/or control gear and/or the external flexible cable containedinthis aminaire shall only be replaced by the manufacturer or his service agent or a similar qualified parson.
This product containsa light sourca of energy efficiency class: see table ‘or label.
© 2021 Signify Holding.
All rights reserved. This document contains information relating to the product portfolio of Signify which information may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or their respective owners.
Signify Holding.
The Netherlands

0000 000 00000 ©2021
signify Holding.All rights reserved
Printed in China
Data subject to change without notice
Keep for future reference: www.philips.com/lighting
PHILIPS WL060V Ledinaire Wall Mount - icon