PULSEWORX KPLD6 Keypad Load Controllers Installation Guide
- June 9, 2024
- PULSEWORX
Table of Contents
PULSEWORX KPLD6 Keypad Load Controllers
FUNCTION
The Keypad Load Controller Series are an all in one Keypad Controller and
Light Dimmer/Relay in a single package. They are able to transmit and receive
UPB® (Universal Powerline Bus) digital commands over the existing power wiring
to remotely turn on, off, and dim other UPB load control devices. No
additional wiring is required and no radio frequency signals are used for
communication.
Models
The KPL is available in two different models: The KPLD Dimmer has a built in
dimmer rated at 400W and the KPLR Relay is the relay version able to handle 8
Amps. Both can be mounted in any wall box that contains neutModelsral, line,
load and ground wires. Available colors are White, Black, and Light Almond.
Engraved Buttons
The KPL’s have white backlit buttons engraved with the designations of: A, B,
C, D, Off, and an Up Arrow and Down Arrow. Custom Engraved buttons are
available enabling you to tailor each button for its particular use. Consult
https://laserengraverpro.com ordering information.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions should always be followed, including the following:
- READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
- Keep away from water. If the product comes in contact with water or other liquid, turn off the circuit breaker and unplug the product immediately.
- Never use products that have been dropped or damaged.
- Do not use this product outdoors.
- Do not use this product for other than its intended purpose.
- Do not cover this product with any material when in use.
- This product uses polarized plugs and sockets (one blade is larger than the other) to reduce the risk of electric shock. These plugs and sockets fit only one way. If they do not fit, consult an electrician.
- SAVE THESE INSTRUCTIONS.
INSTALLATION
The Keypad Load Controllers are designed for indoor use. To install the KPL module in a wallbox follow these instructions:
- Before installing the KPL into a wall box, ensure that power to the wall box has been disconnected by removing the fuse or turning the circuit breaker off. Installing products while the power is on may expose you to dangerous voltage and may damage the product.
- Remove any existing wall plate and device from the wall box.
- Use wire nuts to securely connect the KPL’s white wire to the “Neutral” wire, the KPL’s black wire to the “Line” wire and the red wire to the “Load” wire (see illustration below).
- Fit the KPL into the wall box and secure with mounting screws. Install the wall plate.
- Restore power at the circuit breaker
CONFIGURATION
Once your KPL is installed it can be configured either manually or with
UPStart Configuration Software Version 6.0 build 57 or higher.
Refer to the Keypad Controller’s Manual Configuration Guide available on the
PCS website for further details on Manual
configuration to add your KPL device into a UPB network and link it to various
load control devices.
Although the factory default operation of the KPL is very useful in many
situations, it is highly recommended that you program your KPL with a
Powerline Interface Module (PIM) and UPStart Configuration Software to take
advantage of its many configurable features. User Guides are available on our
website, if you need further assistance on how to configure your system.
SETUP Mode
When configuring a UPB system, it will be necessary to place the KPL into
SETUP mode. To enter Setup Mode, simultaneously press and hold the ON and OFF
buttons for 3 seconds. All of the LED indicators will blink once the device is
in SETUP mode. To exit SETUP mode, again simultaneously press and hold the ON
and OFF buttons for 3 seconds or wait five minutes for it to time out.
Changing a Scene’s Preset Light Levels The Controllers are specially designed
to work with otherPulseWorx® Lighting System devices. Each pushbutton on these
controllers is configured to activate a Preset Light Leveland Fade Rate stored
within the PulseWorx devices. The Preset Light Levels can be easily adjusted
by following this simple procedure:
- Press the pushbutton on the Controller to activate the currently stored Preset Light Levels (scene) in the Wall Switch Dimmer(s).
- Use the local rocker switch on the Wall Switch to set the new desired Preset Light Level.
- Rapidly tap the pushbutton on the Controller five times.
- The WS1D’s lighting load will flash one time to indicate that it has stored the new Preset Light Level.
OPERATION
Once installed and configured the KPL will operate with the stored
configuration settings. Single-tap, double-tap, hold, or release the
pushbuttons to transmit a preset command onto the powerline. Refer to the
Specification Document (available for download) for more details about the
keypad operation. Backlit Pushbuttons Each of the pushbuttons has a Blue LED
behind it to provide back-lighting and to indicate when loads or scenes are
activated. By default, the back-lighting is enabled and pressing a pushbutton
will cause it to illuminate brighter than the others.
Factory Default Settings
To restore the following default settings put the KPL into SETUP mode and
then simultaneously press and hold the A and D buttons for about 3 seconds.
The indicators will light up to indicate that factory defaults have been
restored
Network 10: | 255 |
---|---|
Unit ID KPL06: | 67 |
Unit ID KPLR6: | 68 |
Network Password: | 1234 |
Receive Sensitivity: | High |
Transmit Count: | Twice |
IR Options: | N/A |
LED Options: | Backlight enabled/ Higt |
ON Button: | Link 1: Activate |
A Button Mode: | Link 3: Activate |
B Button Mode : | Link 4: Activate |
C Button Mode: | Link 5: Activate |
O Button Mode: | Link 6: Activate |
OFF Button Mode : | Link 2: Activate |
UP Button Mode: | Last link: Bright Button |
ON Button Mode: | Last link: Dim Button |
Load Settings Link 1 | KPLD / KPLR |
100%/ 100%
Load Settings link 2| 0%/0%
load Settings link 3| 80%/100%
Load Settings Link 4| 60%/100%
Load Settings link S| 40%/ 100%
Load Settings link 6| 20%/ 100%
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in materials and workmanship for a period of five years from the date of purchase. Refer to the warranty information on the PCSwebsite (www.pcslighting.com) for exact details.
19215 Parthenia St. Suite D
Northridge, CA 91324
P: 818.701.9831
pcssales@pcslighting.com
www.pcslighting.com
https://pcswebstore.com
References
- Powerline Control Systems Online Store — PCS Lighting
- Laser Engraving Services - Laser Engraver Pro
- Powerline Control Systems Online Store — PCS Lighting