LUTEC 5164202213 1-Light Bronze Motion Sensing Outdoor Wall Lantern Sconce User Manual

June 9, 2024
LUTEC

LUTEC 5164202213 1-Light Bronze Motion Sensing Outdoor Wall Lantern Sconce User Manual

Please read and understand this entire manual before attempting to assemble, operate, or install the product.

WARNING

  • Consult a qualified electrician if you are not certain about the installation process. Always install wiring connections in accordance with the local code, ordinances, and the National Electric Code.
  • Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
  • Do not attempt to install this product while it is plugged in.
  • Do not connect this light fixture to a dimmer switch or timer.
  • This light fixture is designed to fit standard junction boxes as defined by the National Electrical Code.
  • Do not install motors, transformers, or fluorescent light fixtures on the same

INSTALLATION

OFF BUTTON

INSTALLATION

INSTALLATION

INSTALLATION

(View from bottom of back plate)

\(View from bottom of back plate\)

Manual Override Operation Diagram

Turn wall switch OFF-ON in 1~3 Seconds

SECURITY Mode

Manual Override

Turn off the wall switch, and after 5 seconds turn it on.

INTRUCTION

Choose a mode by rotate the knob on the bottom of the back plate. When power is first applied, the light will turn on immediately. Wait for 15 seconds to allow the sensor to warm up.

  1. TEST MODE(daytime or nighttime operation)
    • Rotate knob on the bottom of back plate to the “TEST” position.
    • When rotate the MODE SELECTOR knob to “SECURITY”, and rotate “TEST/TIME” knob arrow to point to “TEST”, It is turned off after warming up. It is turned on when the motion is detected, and stayed on as long as the motion continues. It is turned off about 5~30 seconds after the motion is no longer detected.
    • When rotate the MODE SELECTOR knob to “DUSK TO DAWN”, and rotate “TEST/TIME” knob arrow to point to “TEST”, it is turned on no matter whether the motion is detected or not.
  2. DUSK TO DAWN MODE (nighttime operation only)
    •  To shift to “DUSK TO DAWN” mode, rotate the mode selector knob to “DUSK TO DAWN”, and rotate “TEST/TIME” knob clockwise by 90° (the photocell is exposed). At dusk the light is turned on automatically, and the light is turned off automatically at dawn.
  3. SECURITY MODE (nighttime operation only)
    • To shift to “SECURITY” mode, rotate the mode selector knob to “SECURITY”, and rotate “TEST/TIME” knob clockwise to point to the desired time setting (between 5 seconds and 10 minutes). At dusk, when motion is detected, the light is turned on and stayed on as long as motion continues. When the motion is no longer detected, the light is remained on for the predetermined time you set (5s ~ 10min), and then turned off automatically.
  * The light is turned off automatically at dawn.
  1. Manual Override Mode (nighttime operation only)
    • To temporarily override the settings in “SECURITY” mode for continuous on at night, rotate the mode selector knob to “SECURITY”, and rotate “TEST/TIME” knob clockwise away from “TEST” position, turn the wall switch “OFF” then turn it “ON” within 1~3 seconds, the light is remained on all night long. To shift back to “SECURITY” mode, turn the wall switch “OFF”, 5 seconds later, turn it “ON”, the light is reset to initial state, wait for warming up then the light is reverted back to “SECURITY” mode.
  * The light is turned off automatically at dawn

Shut-off Delay
The Shut-off delay is the length of time the light will stay on after motion has ceased to be detected. This Shut-off delay can be set when operation is in “SECURITY” mode by using the “TEST/TIME” knob located on the bottom of the back plate. To increase the shut-off delay, turn the knob clockwise. To decrease shut off delay, turn the knob counterclockwise. The delay may be adjusted from a minimum of 5 seconds to a maximum of 10 minutes. The light will stay on as long as motion is detected continuously and will automatically turn off when no more motion is detected after the delay time has passed.

Sensitivity of Motion Sensor
The sensitivity of the motion sensor can be adjusted by using the “SENSITIVITY” knob located on the bottom of the back plate. To increase sensitivity, turn the knob clockwise. To decrease sensitivity, turn the  knob counterclockwise. The sensitivity may be adjusted from a minimum of 5 feet to a maximum of 30 feet.

Adjust The View Angle of Motion Sensor
Rotate the mode selector knob to “SECURITY”, and rotate “TEST/TIME” knob arrow to point to “TEST”, walk in the tested area, when the motion is detected, the light is came on, move to another tested spot, do the same action to check the coverage area of motion detector. There are two coverage dials in the left and right of the lens. When the slot in the coverage dial is aligned to “ ” (no view angle), the built-in detector is covered, the light does not have motion sensor function. When the slot in the coverage dial is aligned to “ ” (moderate view angle), the built-in detector is covered a portion, the view angle is reduced. When the slot in the coverage dial is aligned to “ ” (maximum view angle), the built-in detector is not covered, the view angle is maximum. Rotate either side of the left or right coverage dial or both side of coverage dials to choose desired view angle.

VIEW

SENSOR

NOTE:

  1. The sensitivity of the motion sensor will increase as the environmental temperature gets cooler. For best performance, gently clean the lens with a soft cloth every
    1 or 2 months to assure maximum sensitivity.

  2. For best performance, install fixture at least 6 feet above the ground. At such a height, the fixture will provide a detection distance of up to 30 feet at 77 degrees Fahrenheit.

  3. The sensor detects across a detection range of 180 degrees.

  4. The sensor will be more sensitive to motion across its detection path than motion directly towards it.

  5. To reduce possible nuisances, do not mount the fixture near a heat source like an air conditioner, vent or furnace exhaust, or in a direction facing any reflecting object or other light source

LUTEC USA LLC:
149B Houston Rd Troutman NC 28166
Ningbo UTEC Electric Co.,LTD
CN8, Far East Industry Park , Yuyao, China
www.lutec.com

support@lutec.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals