- Flow Reversal
- Replacing Your Filters
- Installation Diagram
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PRO AQUA BNDL-WEL-RO ELITE Well Water Filtration
Don’t miss out on four (4) free years of additional system coverage.
Register your product within 60 Days from time of purchase to add four years of protection covered under our Pro+Aqua Warranty.
- Locate the serial number on your bracket.
- Visit proaquawater.com/warrantyregistration
- Enter your purchase and serial number information.
No time to go online?
Let our Pro+Aqua Certified Tech Team do the work for you. Simply follow the
steps below and in 2-3 working days we’ll send you confirmation of your
product being registered.
Registration with your mobile device is easy.
- Fill out the form by handwriting your info.
- Take a picture of the form with your device.
- Scan the QR code with your device camera and click the banner that appears.
- Attach the picture of the form to the email that opens.
- Hit Send and you’re DONE!
PRO+AQUA filtration systems are designed in California USA and are made
from quality NSF Approved filters and components.
System Inspection Before Starting
Remove the system and all the components out of the box, take note of all
parts. Inspect the system housings, fittings and connections carefully, make
sure nothing was damaged during transit. If any part is cracked or damaged,
please do not proceed with the installation and contact us or your distributor
for an exchange or diagnosis.
Components List
- 2 Stainless Steel Bolts & Washers
- 1 Bracket (Preinstalled)
- 3 housing (1 clear, 2 black)
- 3 Heads (Preinstalled on bracket)
- 1 Housing Wrench
- 2 Quick Connect Fittings 1” x 1”
- 2 Quick Connect Fittings 1” x 3/4”
- 2 Nipple 1” x 1”
- 1 Removal Tool
Tools Recommended For Installation
- Variable Speed Drill
- Drill Bit
- Bolt Bit
- Adjustable Wrench
- Teflon Tape
- Pen or Pencil
System Maintenance
All of our systems require little maintenance. The only regular maintenance required is filter replacement every 4 – 6 or 6 – 12 months (depending on usage and water quality in your area). It is important to change out your filters at the recommended intervals as indicated in this sheet to keep your system working properly. When replacing any of the filter elements, pay special attention to the housing it belongs to as installing the filters incorrectly will impact the performance of the system.
System installation
-
Shut off the main water line to your home.
-
Install system to wall using the included SS bolts.
-
Attach your incoming supply line to the “IN” Port on the system then attach the line going into your home to the “OUT” port on the system. Plastic fittings recommended. DO NOT solder.
-
Unwrap cartridges and drop into the correct housings, centering on the stand pipe in the bottom of the housing. Stage 1 is closes to the “IN” port on the system.
-
Install housing(s) onto the corresponding head and turn clockwise until snug.
Hand Tighten. (DO NOT OVERTIGHTEN) -
Locate nearest faucet and remove aerator.
- Turn water supply on for 5 min. to flush filters.
- Check system for leaks.
- System is now ready.
Flow Reversal
Depending on the location of your feed water and the entry location of the pipe to your home, you may need to flip the direction flow of your system. This will reverse the flow of your system to be Left to Right.
- Carefully remove the Pressure Gauges from the system.
- Remove the 12 bolts and washer to separate the Cap Module from the Bracket.
- Flip the Cap Module so the IN port is on the opposite side.
- Reinstall the 12 bolts and washer to attach the Cap Module.
- Apply new Teflon to the Pressure Gauges to prevent any leaks. Ensure to apply plenty of Teflon, it should feel snug while installing the Pres-sure Gauges.
- The Flow Direction is now flipped.
Replacing Your Filters
Replacement Filter Set: FC-PK-100E
To insure your system keeps performing at its best, only use original OEM
Certified filters, untested filters will reduce performance and void its
warranty.
Before starting: Turn incoming water off then press and hold the PR
button to relief the pressure in the system. Ensure to place a bucket or rag
to catch any splashing water.
- Remove housing using the housing wrench by turning the handle counterclockwise.
- Remove the old filter and install the new filter. Ensure to center the filter cartridge properly in the housing.
- Inspect the O-Ring on the housing for any damage or cracks. Ensure the O-Ring is sitting properly in the groove. Lubricate the O-Ring and housing threads with silicone lubricant or a food-grade lubricant.
- Reinstall the housing by pushing the housing up and at the same time turning the housing clockwise. Ensure to keep the housing and filter cartridge straight. Improper installation will cause the filter cartridge to not sit properly in the housing and will prevent the housing from closing all the way.
Hand tighten. Do not overtighten housing.
Optional Add Ons
Ball Valves, Bypass, Ground Jumper Wire, Water Softener, Post Filter, and UV
Filter are not included.
Warning
The plastic components of the system will interrupt the continuity of the
grounded (conductive) plumbing system. A grounded “jumper wire” bridging the
equipment to the plumbing system must be installed prior to systems use.
Consulting a Licensed Plumber is highly recommended (see Installation
Diagram).
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. It is highly
recommended to test your well at least once a year to properly manage your
water quality and
Caution
Filtration System must be protected against freezing and extreme heat, which
can cause the housing(s) to crack and the components to fail and may cause
water leakage. Filtration system should not be installed in direct sunlight
since UV rays make housings and other components brittle.
It is important that the O-ring be properly seated or a water leak could occur
as the O-ring provides the water-tight seal between the cap and the housing.
To prevent possible water damage, housings should be replaced every 4 years (5
years for clear housings).
Operational Parameters
Installation needs to comply with state and local plumbing regulations. These
systems are in-tended to be used with cold water only.
Maximum | Minimum | |
---|---|---|
Operational Temperature | 100°F (37.8°C) | 40°F (4.4°C) |
Operating Pressure | 80 psi (5.98 kg/cm²) | 20psi (1.406 kg/cm²) |
pH Parameters | 10 | 5 |