WayPoint10A Series AC Outdoor Power Supplies Installation Guide
- June 2, 2024
- WAYPOINT
Table of Contents
WayPoint10A Series
AC Outdoor Power Supplies
10A Series AC Outdoor Power Supplies
Models Include:
WayPoint10AU
– 24VAC @ 4A and/or 28VAC @ 3.5A.
– Two (2) fuse protected outputs.| WayPoint10ADU
– 24VAC @ 4A and/or 28VAC @ 3.5A.
– Two (2) Class 2 Rated PTC protected power-limited outputs.
---|---
WayPoint10A4U
– 24VAC @ 4A or 28VAC @ 3.5A.
– Four (4) fuse protected outputs.| WayPoint10A4DU
– 24VAC @ 4A or 28VAC @ 3.5A.
– Four (4) Class 2 Rated PTC protected power-limited outputs.
WayPoint10A8U
– 24VAC @ 4A or 28VAC @ 3.5A.
– Eight (8) fuse protected outputs.| WayPoint10A8DU
– 24VAC @ 4A or 28VAC @ 3.5A.
– Eight (8) Class 2 Rated PTC protected power-limited outputs.
Installation Guide
More than just power.TM
Rev. 091514-10A
Installing Company: ____ Service Rep. Name:
Address: __ Phone #: _____
Overview:
Altronix WayPoint Outdoor Power Supplies provide 24VAC and/or 28VAC distributed via two (2), four (4) or eight (8) outputs for powering CCTV cameras, heaters, and other video accessories.
WayPoint10A Series AC Reference Chart:
Altronix
Model Number
| Output Voltage| Total Output Current (Power)| Number and Type of Outputs|
Fuse Output Ratings| PTC Output Ratings| Class 2 Rated power-limited outputs|
Input Current Draw| Product Weight
---|---|---|---|---|---|---|---|---
115VAC
60Hz| 230VAC
50Hz
WayPoint10AU| 24VAC| 4A| 1| 5A/32V*| ****
–
| ****
–
| ****
1.0A
| ****
0.5A
| ****
4.68kg
28VAC| 3.5A
24VAC and 28VAC| 3.5A| 1 of each
WayPoint10ADU| 24VAC| 4A| 1| ****
–
| ****
9A
| |
4.68kg
28VAC| 3.5A
24VAC and 28VAC| 3.5A| 1 of each
WayPoint10A4U| 24VAC| 4A| 4 Fused| 5A/
32V*
| –| –| 4.8kg
28VAC| 3.5A
WayPoint10A4DU| 24VAC| 4A| 4 PTCs| –| 2.5A| | 4.8kg
28VAC| 3.5A
WayPoint10A8U| 24VAC| 4A| 8 Fused| 5A/
32V*
| –| –| 4.95kg
28VAC| 3.5A
WayPoint10A8DU| 24VAC| 4A| 8 PTCs| –| 2.5A| | 4.95kg
28VAC| 3.5A
*Lower rated fuses can be used.
Specifications:
Agency Listings:
-
UL/cUL Listed:
UL 60950-1 Information Technology Equipment.
UL 60950-22 Equipment to be Installed Outdoors. -
CE European Conformity.
Input:
- Input: 115VAC, 60Hz,1A or 230VAC, 50Hz, 0.5A.
Output:
-
Output options:
a. 24VAC or 28VAC.
b. Both 24VAC and 28VAC (WayPoint10AU/ADU only). -
Fuse ratings:
WayPoint10A Series incorporate 5A/32V fuses.
Visual Indicators:
- Individual power output LED indicators.
- Illuminated master power switch.
Features:
- Surge suppression.
- Spare fuses included.
Accessories:
- Optional PMK1 Pole Mount Kit simplifies installation of outdoor units.
Enclosure:
- NEMA 4/4X, IP66-11 Rated enclosure for outdoor use.
- Enclosure Dimensions (H x W x D approx.): 13.31” x 11.31” x 5.59” (338.1 mm x 287.3 mm x 142 mm).
Installation Instructions:
Unit shall be installed in accordance with The National Electrical Code and all applicable Local Regulations.
-
Remove backplane from enclosure prior to mounting (do not discard hardware).
-
Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 4).
Note: Inlets for conduit fittings should only be made on the bottom of the enclosure.
UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets. -
Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure enclosure with appropriate fasteners (Fig. 5, pg. 8 and Fig. 11, pg. 12).
-
Mount back plane to enclosure with hardware.
-
Set the input voltage selector switch for 115VAC or 230VAC operation (Figs. 2-4, pgs. 5-7)
-
To facilitate wire entry utilize weather-tight NEMA 4 rated connectors, bushings, and cable.
-
Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 5-7).
-
Connect unswitched AC power (115VAC/230VAC, 50/60Hz) to terminals marked [L, N] (Figs. 2-4, pgs. 5-7).
Green branch wire connects to earth (safety) ground lug .
Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter). -
Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 5-7).
-
WayPoint10A4U/A4DU, WayPoint10A8U/A8DU are factory set for 24VAC operation.
For 28VAC operation adjust unit prior to mounting and applying power as follows:
Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected to the terminal marked [S]. -
Measure output voltage on terminals marked [COM, 24V, 28V] on WayPoint10AU or WayPoint1OADU (Fig. 2, pg. 5) or [1-4] or [1-8 COM] on WayPoint10A4U, WayPoint10A4DU, WayPoint10A8U and WayPoint10A8DU before connecting devices (Fig. 3, pg. 6, Fig. 4, pg. 7).
This helps avoiding potential damage. -
Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 5-7).
-
Connecting devices to WayPoint10AU or WayPoint10ADU:
For 24VAC output connect devices to terminals marked [COM, 24V] (Fig. 2, pg. 5).
For 28VAC output connect devices to terminals marked [COM, 28V] (Fig. 2, pg. 5).
Connecting devices to WayPoint10A4U or WayPoint10A4DU:
Connect device to terminals marked [1-4] and [COM] (Fig. 3, pg. 6).
Connecting devices to WayPoint10A8U or WayPoint10A8DU:
Connect device to terminals marked [1-8] and [COM] (Fig. 4, pg. 7). -
Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 5-7).
-
LEDs will illuminate indicating each output is powered (Figs. 2-4, pgs. 5-7).
-
Upon completion of wiring secure enclosure door with latches and optional lock.
Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: When installing in a non-restricted service area use lock or
other fastened means on door latches. This installation should be made by
qualified service personnel and should conform to the National Electrical
Code and all local codes.
Bottom of Enclosure
LED Identification Chart:
ON | OFF |
---|---|
Normal operating condition. | No AC output. Blown fuse or tripped PTC, |
illuminated master power disconnect circuit breaker is tripped or OFF, AC failure.
To reset a tripped PTC turn the power off for 1 minute and then turn it back on.
Technical Specifications:
Parameter | Description |
---|---|
Input power requirements | 115VAC, 60Hz, 1A or 230VAC, 50Hz, 0.5A. |
Indicators | Individual power output LED indicators. Illuminated master |
power switch.
Environmental Conditions| Operating Ambient Temperature:
For 24VAC @ 4A output: – 40°C to 60°C (– 40°F to 140ºF).
For 28VAC @ 3.5A output: – 40°C to 70°C (– 40°F to 158ºF).
Relative Humidity: 85%, +/– 5%
Storage Temperature: – 40ºC to 75ºC (– 40ºF to 167ºF).
Operating Altitude: – 304.8 to 2,000m.
Regulatory Compliance| UL/cUL Listed for Information Technology
Equipment (UL 60950-1)
Equipment to be Installed Outdoors (UL 60950-22). CE
European Conformity.
Fig. 2 – WayPoint10AU (Fuses)
Fig. 3 – WayPoint10A4U (Fuses)
Fig. 4 – WayPoint10A8U (Fuses)
Wall Mount Installation:
1- Place unit at desired location and secure with mounting screws (not included) (Fig. 5, pg. 8).
Pole Mounting Using Optional Pole Mount Kit PMK1:
This installation should be made by qualified service personnel. This product
contains no serviceable parts.
PMK1 outdoor pole mount kit is designed to simplify the installation of
Altronix outdoor rated power supplies and accessories housed in models WP1,
WP3 and WP4 NEMA rated enclosures. PMK1 can be mounted on 2” to 8” (50.8mm to
203.2mm) diameter round or 5” (127mm) square poles. Brackets are designed for
use with the Wormgear Quick Release Straps (two included).
- Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 6, pg. 8).
- Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16” hex socket driver (Fig. 7, pg. 8 and Fig. 9, pg. 8).
- Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 8, pg. 8).
- Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (Fig. 9, pg. 8).
- Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 7, pg. 8).
- Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with flat head screwdriver or 5/16” hex socket driver (Fig. 7, pg. 8).
- Clip excess straps.
For fuse protected models:
Replace fuses with the same type and rating 5A/32V.
The lightning flash with arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE
within the product’s enclosure that may be of sufficient magnitude to
constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure.
There are no user serviceable parts inside.
Refer servicing to qualified service personnel.
Notes:
Enclosure Dimensions (H x W x D approximate):
13.31” x 11.31” x 5.59” (338.1mm x 287.3mm x 142mm) Altronix is not
responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056
website: www.altronix.com | e-mail:
info@altronix.com | Lifetime Warranty