MOOVAIR MI2-400T1DHN1 Middle Static Pressure Duct Type Air Conditioner Owner’s Manual

June 3, 2024
MOOVAIR

MOOVAIR MI2-400T1DHN1 Middle Static Pressure Duct Type Air Conditioner

MOOVAIR MI2-400T1DHN1 Middle Static Pressure Duct Type Air
Conditioner IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Safety Precautions

Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain, and troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of your unit.
Please pay attention to the follow ing signs:

WARNING

Failure to observe a warning may result in death. The appliance must be installed by installers or contractors w ho are licensed HVAC professionals and in compliance with all local, state and provincial law s.
CAUTION
Failure to observe a caution may result in injury or equipment damage.
WARNING

  • Ask an authorized dealer to install this air conditioner. Inappropriate installation may cause water leakage, electric shock, or fire.
  • The warranty will be voided if the unit is not installed by professionals.
  • If abnormal situation arises (like burning smell), turn off the power supply and call your dealer for instructions to avoid electric shock, fire or injury.
  • DO NOT let the indoor unit or the remote control get wet. It may cause electric shock or fire.
  • DO NOT insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
  • DO NOT use a flammable spray such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.

CAUTION

  • DO NOT touch the air outlet while the swing flap is in motion. Fingers might get caught or the unit may break down.
  • DO NOT inspect the unit by yourself. Ask an authorized dealer to perform the inspection.
  • To prevent product deterioration, do not use the air conditioner for preservation purposes (storage of food, plants, animals, works of art, etc.).
  • DO NOT touch the evaporator coils inside the indoor unit. The evaporator coils are sharp and may cause injury.
  • DO NOT operate the air conditioner with wet hands. It may cause electric shock.
  • DO NOT place items that might be affected by moisture damage under the indoor unit. Condensation can occur at a relative humidity of 80%
  • DO NOT expose heat-producing appliances to cold air or place them under the indoor unit. This may cause incomplete combustion or deformation of the unit due to the heat.
  • After long periods of usage, check the indoor unit to see if anything is damaged. If the indoor unit is damaged, it may fall and cause injury
  • If the air conditioner is used together with other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
  • DO NOT climb onto or place objects on top of the outdoor unit.
  • DO NOT operate the air conditioner when using fumigant insecticides. The chemicals may become layered with the unit and endanger those who are hypersensitive to chemicals.
  • DO NOT let children play with the air conditioner.
  • The air conditioner can be used by children aged 8 years and older and people with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, if they have been given instruction on how to properly and safely operate the system.
  • DO NOT operate the air conditioner in a wet room (e.g. bathroom or laundry room). This can cause electrical shock and cause the product to deteriorate.
  • An all-pole disconnection device which has at least 3mm separation distance in all pole and a residual current device (RCD) with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard
  • The appliance shall be installed in accordance with national wiring regulations.
  • The indoor unit must be installed 2,5m above floor.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.

Indoor Unit Parts And Major Functions

Unit Parts

Operating Conditions

Use the system under the following temperatures for safe and effective operation. If the air conditioner is used under different conditions, it may malfunction or become less efficient.

COOL mode                HEAT mode          DRY mode

Room Temperature| 17°C – 32°C (62°F – 90°F)| 0°C – 30°C (32°F – 86°F)| 17°C – 32°C (62°F – 90°F)
Outdoor Temperature| 0°C – 50°C (32°F – 122°F)| -15°C – 24°C (5°F – 76°F)| 0°C – 50°C (32°F – 122°F)
-15°C – 50°C (5°F – 122°F) (For models with low temp. cooling systems.)
18°C – 54°C (For special tropical models)| -7°C – 24°C| 0°C – 60°C (For special tropical models)

FOR OUTDOOR UNITS WITH AUXILIARY ELECTRIC HEATER
When outside temperature is below 0°C (32°F ), we strongly recommend keeping the unit plugged in at all time to ensure smooth ongoing performance.

Features

Default Setting

When the air conditioner restarts after a power failure, it will default to the factory settings (AUTO mode, AUTO fan, 24°C (76°F)). This may cause inconsistencies on the remote control and unit panel. Use your remote control to update the status.
Auto-Restart (some models)
In case of power failure, the system will immediately stop. When power returns, the Operation light on the indoor unit will flash. To restart the unit, press the ON/ OFF button on the remote control. If the system has an auto restart function, the unit will restart using the same settings.

Louver Angle Memory Function (Optional)
Some models are designed with a louver angle memory function. When the unit restarts after a power failure, the angle of the horizontal louvers will automatically return to the previous position. The angle of the horizontal louver should not be set too small as condensation may form and drip into the machine. To reset the louver, press the manual button, which will reset the horizontal louver settings.
Refrigerant Leak Detection System (some models)
In the event of a refrigerant leak, the LCD screen will display “EC” and the LED indicator light will flash.

Energy Saving Tips
  • DO NOT set the unit to excessive temperature levels.
  • While cooling, close the curtains to avoid direct sunlight.
  • Doors and windows should be kept closed to keep cool or warm air in the room.
  • DO NOT place objects near the air inlet and outlet of the unit.
  • Set a timer and use the built-in SLEEP/ECONOMY mode if applicable.
  • If you don’t plan to use the unit for a long time, remove the batteries from the remote control.
  • Clean the air filter every two weeks.
  • Adjust louvers properly and avoid direct airflow.

Manual Operations

This display panel on the indoor unit can be used to operate the unit in case the remote control has been misplaced or is out of batteries.

  • M ANUAL button: This button selects the mode in the following order: AUTO, FORCED COOL, OFF.
  • FORCED COOL mode: In FORCED COOL mode, the Operation light flashes. The system will then turn to AUTO after it has cooled with a high wind speed for 30 minutes. The remote control will be disabled during this operation.
  • OFF mode: When the panel is turned OFF, the unit turns off and the remote control is re-enabled.

Care And Maintenance

  Safety Precautions
  • Contact an authorized service technician for repair or maintenance. Improper repair and maintenance may cause water leakage, electrical shock, or fire, and may void your warranty.
  • DO NOT substitute a blown fuse with a higher or lower amperage rating fuse, as this may cause circuit damage or an electrical fire.
  • Make sure the drain hose is set up according to the instructions. Failure to do so could cause leakage and result in personal property damage, fire and electric shock.
  • Make sure that all wires are connected properly. Failure to connect wires according to instructions can result in electrical shock or fire.
Unit M aintenance

BEFORE CLEANING OR M AINTENANCE

  • Always turn off your air conditioning system and disconnect the power supply before cleaning or maintenance
  •  DO NOT use chemicals or chemically treated cloths to clean the unit.
  • DO NOT use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
  • DO NOT wash the unit under running water. Doing so creates an electrical hazard.
  • DO NOT use water hotter than 40°C (104°F) to clean the front panel. This can cause the panel to become deformed or discolored.
  • Clean the unit using a damp, lint-free cloth and neutral detergent. Dry the unit with a dry, lint-free cloth.
How To Clean The Air Filter

The filter prevents dust and other particles from entering the indoor unit. Dust buildup can reduce the efficiency of the air conditioner. For optimum efficiency, clean the air filter every two weeks or more frequently if you live in a dusty area. Replace the filter with a new one if it’s heavily clogged and cannot be cleaned.

WARNING: DO NOT REM OVE OR CLEAN THE FILTER BY YOURSELF

Removing and cleaning the filter can be dangerous. Removal and maintenance must be performed by a certified technician.
NOTE: In households with animals, you will have to periodically wipe down the grille to prevent animal hair blocking airflow.

  1. If the unit you purchased is a rear ventilated one, take off the filter in the directions indicated by the arrows in the following diagram.

  2. If the unit you purchased is a declensional ventilated model, take off the filter
    in the directions indicated by the arrows in the following diagram

  3. Remove the air filter. 4. Clean the air filter by vacuuming the surface or washing it in warm water with mild detergent.
    A. If using a vacuum cleaner, the inlet side should face the vacuum.

B. If using water, the inlet side should face down and away from the water stream

  1. Rinse the filter with clean water and allow it to air-dry. DO NOT let the filter dry in direct sunlight.
  2. Reinstall the filter with clean water and allow it to air-dry. DO NOT let the filter dry in direct sunlight.
  3. Repairing Refrigerant Leaks

WARNING

  • If the refrigerant leaks, turn off the air conditioner and any combustible heating devices, ventilate the room and call your dealer immediately. Refrigerant is both toxic and flammable. DO NOT use the air conditioner until the leak is repaired.

  • When the air conditioner is installed in a small room, measures must be taken to prevent the refrigerant concentration from exceeding the safety limit in the event of refrigerant leakage. Concentrated refrigerant causes a severe health and safety threat.
    Refrigerant Leak Detection System (some models)

  • In the event of a refrigerant leak, the LCD screen will display “EC” and the LED indicator light will flash.

Preparation For Periods Of Non-Use

Maintenance after Extended Non-Use

  1. Remove any obstacles blocking the vents of both the indoor and outdoor units.
  2. Clean the air filter and the front grille of the indoor unit. Reinstall the clean, dry air filter in its original position.
  3. Turn on the main power switch at least 12 hours prior to operating the unit.

Storing the Unit While Not In Use

  1. Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold.
  2. Turn off the appliance and unplug it.
  3. Clean the air filter according to the instructions in the previous section. Reinstall the clean, dry filter before storing.
  4. Remove the batteries from the remote control.

Troubleshoot ing

CAUTIONS
If one of the following conditions occurs, switch off the power supply immediately and contact your dealer for further assistance.

  • The operation light continues to flash rapidly after the unit has been restarted.
  • The remote control buttons do not work.
  • The unit continually trips fuses or circuit breakers.
  • A foreign object or water enters the air conditioner.
  • Other abnormal situations.
Common Problems

The following symptoms are not a malfunction and in most situations will not require repairs.

Unit does not turn on when pressing ON/ OFF button| The unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.
---|---
Cooling and Heating Models: If the Operation light and PRE-DEF (Pre-heating/ Defrost) indicators are lit up, the outdoor temperature is too cold and the unit’s anti-cold wind is activated in order to defrost the unit.
In Cooling-only Models: If the “Fan Only” indicator is lit up, the outdoor temperature is too cold and the unit’s anti-freeze protection is activated in order to defrost the unit.
The unit changes from COOL mode to FAN mode| The unit changes its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit will resume operating when the temperature fluctuates again.
The indoor unit emits white mist| In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist.
Both the indoor and outdoor units emit white mist| When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.
The indoor unit makes noises| A squeaking sound is heard when the system is OFF or in COOL mode. The

noise is also heard when the drain pump (optional) is in operation.

A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.
Both the indoor unit and outdoor unit make noises| A low hissing sound may occur during operation. This is normal and is caused by refrigerant gas flowing through both the indoor and outdoor units.
A low hissing sound may be heard when the system starts, has just stopped running or is defrosting. This noise is normal and is caused by the refrigerant gas stopping or changing direction.
The outdoor unit makes noises| The unit will make different sounds based on its current operating mode.
Dust is emitted from either the indoor or outdoor unit| The unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.
The unit emits a bad odor| The unit may absorb odors from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations.
**| The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operate**| During operation, the fan speed is controlled to optimize product operation.

Troubleshooting Tips
Problem Possible Causes Solution
The unit is not working Power failure Wait for the power to be

restored
The power switch is off| Turn on the power
The fuse is burned out| Replace the fuse
Remote control batteries are dead| Replace the remote control batteries
The unit’s 3-minute protection has been activated| Wait three minutes after restarting the unit

Poor cooling performance

| Temperature setting may be higher than the ambient room temperature| Lower the temperature setting
The heat exchanger on the indoor or outdoor unit is dirty| Clean the affected heat exchanger
The air filter is dirty| Remove the filter and clean it according

to instructions

The air inlet or outlet of either unit is blocked| Turn the unit off, remove the obstruction and turn it back on
Doors and windows are open| Make sure that all doors and windows are closed while operating the unit
Excessive heat is generated by sunlight| Close windows and curtains during periods of high heat or bright sunshine
Low refrigerant due to leak or long-term use| Check for leaks, re-seal if necessary and top off refrigerant
The unit starts and stops frequently| There’s too much or too little refrigerant in the system| Check for leaks and recharge the system with refrigerant
There is air, incompressible gas or foreign material in the refrigeration system| Evacuate and recharge the system with refrigerant
System circuit is blocked| Determine which circuit is blocked and replace the malfunctioning piece of equipment
The compressor is broken| Replace the compressor
The voltage is too high or too low| Install a ministate to regulate the voltage
Poor heating performance| The outdoor temperature is lower than 7°C (44.5°F)| Check for leaks and recharge the system with refrigerant
Cold air is entering through doors and windows| Make sure that all doors and windows are closed during use
Low refrigerant due to leak or long-term use| Check for leaks, re-seal if necessary and top off refrigerant

Error Codes

Number| Cause| The number of flashes per second| Time indicator| Error Code
---|---|---|---|---
1| Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error| 1| Off| E0
2| Indoor and outdoor unit communication malfunction| 2| Off| E 1
3| Indoor fan speed malfunction| 4| Off| E3
4| Indoor room temperature sensor error| 5| Off| E4
5| Evaporator coil temperature sensor error| 6| Off| E5
6| Refrigerant leak detection system malfunction| 7| Off| EC
7| Water level alarm malfunction| 8| Off| EE
8| Dual indoor unit (twin model only) communication malfunction| 9| Off| E8
9| Other twin model malfunction| 10| Off| E9
10| Overload protection| 1| On| F0
11| Outdoor temperature sensor error| 2| On| F 1
12| Outdoor condenser pipe sensor error| 3| On| F2
13| Discharge air temperature sensor error| 4| On| F3
14| Outdoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error| 5| On| F4
15| Outdoor fan speed (DC fan motor only) malfunction| 6| On| F5
16| Inverter module IPM protection| 1| Flash| P0
17| High/Low voltage protection| 2| Flash| P 1
18| Compressor top overheating protection| 3| Flash| P2
19| Outdoor low temperature protection| 4| Flash| P3
20| Compressor drive error| 5| Flash| P4
21| Mode conflict| 6| Flash| P5
22| Compressor low-pressure protection| 7| Flash| P6
23| Outdoor IGBT sensor error| 8| Flash| P7
24| Indoor unit communication malfunction| 11| On| fa

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals