The Aquarius Fountain Set Classic is available in multiple models: 750, 1000, 2000, 3000, and 4000. It is designed for pumping normal water to create fountains. The product includes a filter housing with a filter pump, a transition piece to fasten the filter pump to the filter cover, a branch valve with flow-rate regulators, a stepped hose adapter for connection of a rivulet or waterspout, a union nut for fastening the nozzle pipe on the branch valve, a nozzle pipe, and nozzle inserts (Vulkan, Lava, Magma) for different water patterns. The unit is dust-tight and water-tight down to 2 meters and should not be disposed of with normal household waste.

Product Usage Instructions

WARNING: Disconnect all electrical devices in the water from the power supply before reaching into the water to avoid the risk of severe injuries or death by electrocution. Only operate the unit when no persons are in the water. This unit can be used by children aged 8 and above and by persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit safely and understand the hazards involved. Children should not play with the unit but can carry out cleaning and user maintenance under supervision.

Safety Information:

  • Only connect the unit if the electrical data of the unit and the power supply match.
  • Plug the unit into a correctly installed outlet that is fused for a rated fault current of max. 30 mA using a fault current protection device.
  • Protect the plug connections from moisture.
  • Do not use the unit if electrical lines or the housing are damaged. Dispose of the unit in such cases.
  • Keep a distance of at least 0.2 m between the unit’s magnet and pacemakers or implantable cardioverter defibrillators (ICDs).
  • Do not carry or pull the unit by its power cable.
  • Route lines in a way that they are protected from damage and do not present a tripping hazard.
  • Contact the authorized customer service or OASE for assistance with problems.

Intended Use:

  • Only use the product for pumping normal water to create fountains.
  • Operate the unit according to the provided instructions.

Restrictions:

  • Do not use the unit in swimming ponds.
  • Never use the unit with fluids other than water.
  • Never run the unit without water.
  • Do not use the unit for commercial or industrial purposes.

Symbols on the Unit:

  • The unit is dust-tight and water-tight down to 2 m.
  • Remove the unit in freezing temperatures.
  • Danger for persons with pacemakers. The unit contains a strong magnet.
  • Do not dispose of the unit with normal household waste.
  • Read the operating instructions.

Installing the Pump:

WARNING: Never operate the unit in a swimming pond to avoid death or serious injuries from hazardous electrical voltage.

WARNING

  • Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise, there is a risk of severe injuries or death by electrocution.
  • Only operate the unit if no persons are in the water.
  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit safely and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.

Safety information

Electrical connection

  • Only connect the unit if the electrical data of the unit and the power supply
  • Only plug the unit into a correctly installed outlet. Ensure that the outlet is fused for a rated fault current of max. 30 mA using a fault current protection de-
  • Protect the plug connections from

Safe operation

  • Do not use the unit, if electrical lines or the housing are
  • A damaged connection cable cannot be disposed of in the unit.
  • The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Keep a distance of at least 0.2 m between the implant and the magnet.
  • Do not carry or pull the unit by its power
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Should problems occur, please contact the authorized customer service or

Product Description

OverviewOase-750-Aquarius-Fountain-Set-Classic-FIG-
\(1\)

  1. Filter housing with filter pump
  2. The transition piece fastens the filter pump to the filter cover
  3. Branch valve with flow-rate regulators
  4. Stepped hose adapter 13/19/25 mm for connection of a rivulet or waterspout
  5. Union nut for fastening the nozzle pipe on the branch valve
  6. Nozzle pipe
  7. Nozzle mount
  8. Nozzle inserts (Vulkan, Lava, Magma) for different water patterns

Intended use
Only use the product described in this manual as follows:

  • Pumping of normal water for creating fountains.
  • Operate by instructions.

The following restrictions apply to the unit:

  • Do not use it in swimming ponds.
  • Never use the unit with fluids other than water.
  • Never run the unit without water.
  • Do not use for commercial or industrial purposes.

Symbols on the unit

  • The unit is dust-tight and water-tight down to 2 m.
  • Remove the unit in the event of freezing temperatures.
  • Danger for persons with pacemakers. The unit contains a strong magnet.
  • Do not dispose of the unit with the normal household waste.
  • Read the operating instructions

Installing the pump

WARNING: Death or serious injuries from hazardous electrical voltage due to the operation of this unit in a swimming pond.

Oase-750-Aquarius-Fountain-Set-Classic-FIG- \(2\)

  • Never operate the unit in a swimming pond.

  • Ensure that the connection to the power supply is at least 2 m from the pond.

  • Place the pump horizontally on a stable, mud-free surface.

  • The pump is underwater, and the nozzle intake emerges from the water.
    TIP : Thoroughly clean the pond or pool and place the pump approx. 200 mm above the bottom of the pond, so that no muddy water runs through the pump.

  • Muddy water will cause the nozzle to clog faster and the impeller unit to become worn prematurely

Commissioning/start-up

NOTE: Never connect the pump to a dimmer. Otherwise, the pump will be destroyed.

Maintenance and cleaning

NOTE : Never use chemical cleaning agents. These are hazardous to animals, plants, and the environment.

  • Only use clear water and a soft brush to clean the unit.

Recommendation regarding cleaning:

  • Clean the unit as required, but at least twice a year.
  • When cleaning the pump, pay particular attention to the impeller unit and the pump housing.

Opening/closing the housing
Before closing the housing, place the power cable in the recess in the housing to prevent it from being crushed.

  • Opening the housing
  • Closing the housing

Cleaning/replacing the impeller unit

  • Remove the pump cover or pump housing from the motor housing by turning it counterclockwise (bayonet catch).
  • After removing the impeller unit, clean all parts under the running tap
  • Replace a worn or damaged impeller
  • Assemble in the reverse order.Oase-750-Aquarius-Fountain-Set-Classic-FIG- \(10\)

Cleaning/replacing the impeller unit

  • Remove the pump cover or pump housing from the motor housing by turning it counterclockwise (bayonet catch).
  • After removing the impeller unit, clean all parts under the running tap
  • Replace a worn or damaged impeller
  • Assemble in the reverse order.

Malfunction remedyOase-750-Aquarius-Fountain-Set-Classic-FIG-
11

Technical data

Unit data|
---|---
Aquarius Fountain Set Eco|  | 750| 1000| 2000| 3000| 4000
Rated voltage| AC V| 230| 230| 230| 230| 230
Mains frequency| Hz| 50| 50| 50| 50| 50
Power consumption| W| 9| 11| 18| 26| 42
Protection type|  | IP 68| IP 68| IP 68| IP 68| IP 68
Max. pump capacity| l/h| 720| 1000| 2100| 3000| 4000
Max. water column| m| 1.1| 1.3| 2.1| 2.5| 2.9
Max. pump immersion depth| m| 2| 2| 2| 2| 2
Water feature connection|  | G1| G1| G1| G1| G1
Stepped hose adapter| mm| 13/19/25| 13/19/25| 13/19/25| 13/19/25| 13/19/25
Dimensions           Length| mm| 205| 205| 205| 205| 205
Width| mm| 180| 180| 180| 180| 180
Height| mm| 140| 140| 140| 140| 140
Weight| kg| 1.8| 1.8| 2.0| 2.2| 2.7
Permissible water values|
---|---
 |  | Freshwater, pond water
pH value|  | 6.8 … 8.5
Hardness| °dH| 8 … 15
Free chlorine| mg/l| <0.3
Chloride content| mg/l| <250
Salt content| %| <0.4
Overall dry residue| mg/l| <50
Temperature| °C| +4 … +35

Wear parts

  • Impeller unit

Spare parts
The use of original parts from OASE ensures the continued safe and reliable operation of the unit. Please visit our website for spare parts drawings and spare parts. www.oase.com/ersatzteile

Disposal
NOTE:

  • Do not dispose of this unit with household waste.
  • Dispose of the unit by using the return system provided for this purpose.
  • Render the unit unusable by cutting the cables.