  1. Channel/RDM/Stand-alone function/Leading edge or trailing edge/Numeric display/Din rail

Features

  • AC phase-cut mosfet dimmer with DMX512 function, one channel output.
  • Comply with the DMX512 standard protocols.
  • Digital numeric display, set DMX decode start address by bottoms.
  • RDM function can realize intercommunication between DMX master and decoder.
  • Reverse-phase dimming or forward-phase dimming selectable.
  • Minimum brightness set from 1% to 40%.
  • Stand-alone dynamic mode and dimmer mode selectable, which be controlled by buttons with built-in programs, instead of DMX signal.
  • To dim and switch single color dimmable LED lamps, traditional incandescent and halogen lights.
  • Overheat protection, recover automatically.
  • Available in white or black.

Technical Parameters

Input and Output

Input voltage 100-240VAC
Output voltage 100-240VAC
Output current 1CH, 2A
Output power 200-480W

Safety and EMC

EMC standard (EMC)| ETSI EN 301 489-1 V2.2.3
ETSI EN 301 489-17 V3.2.4
---|---
Safety standard(LVD)| EN 62368-1:2020+A11:2020
Certification| CE,EMC,LVD

Dimming data

Input signal DMX512
Dimming level 256 levels
Dimming range 0 -100%

Environment

Operation temperature Ta: -30° C ~ +55°C
Case temperature (Max.) T c: +85°C
IP rating IP20

Warranty

  Warranty  5 years

Weight

Gross weight  0.130kg
  Net weight  0.160kg

Compatible Load Types

Load Type Maximum Load Remarks
Dimmable LED lamps 300W @ 220V
150W @ 110V Due to variety of LED lamp designs, maximum number of LED lamps

is further dependent on power factor result when connected to dimmer.
Triac Dimmable
LED drivers| 300W @ 220V
150W @ 1 1 OV| Maximum permitted number of drivers is 300W divided by driver nameplate power rating, and make sure the surge current is no more than 2 times 65A.
Incandescent lighting,
HV Halogen lamps| 500W @ 220V
250W @ 1 10V|

Mechanical Structures and Installations

MOKUNGIT S1-D1 AC Triac DMX Dimmer - 8

Wiring Diagram

MOKUNGIT S1-D1 AC Triac DMX Dimmer - 7

Caution:
Please carefully ensure all wire connections and polarities are correct and secure before applying power, otherwise this controller will be damaged.
Note: When calculating the maximum number of load lamps or drivers, the input power or input current parameters of a single lamp or driver must be used, the output power parameters can not be used. In addition, the maximum surge current of the dimmer is 65A, the sum of surge current of multiple dimmable LED drivers should not exceed 2 times. otherwise, the product will be overloaded and damaged.

Operation

System parameter setting

  • Long press M and ◀ key for 2s, prepare for setup system parameter: control method, minimum brightness curve, default output level, automatic blank screen. short press M key to switch four item.
  • Control method: short press ◀ or ▶ key to switch forward-phase(“C-F”) or reverse-phase(“C-R”).

MOKUNGIT S1-D1 AC Triac DMX Dimmer - 2

  • Minimum brightness: short press ◀ or ▶ key to set minimum brightness, from 1% to 40%(“b01″ to”b40”). You need set suitable minimum brightness to avoid
  • Default output level: press ◀ or ▶ key to change default 0-100% level (“d00” to “dFF” ) when no DMX input signal.
  • Automatic blank screen: short press ◀ or ▶ key to switch enable(“bon”) or disable(“boF”) automatic blank screen.
  • Long press M key for 2s or timeout 10s, quit system parameter setting.

DMX mode

  • Short press M key, when display 001~512, enter DMX mode.
  • Press ◀ or ▶ key to change DMX decode start address(001~512), long press for fast adjustment.
  • If there is a DMX signal input, will enter DMX mode automatically.
  • DMX Dimming: Each S1-D1 DMX decoder occupy 1 DMX address when connecting the DMX console.

Stand-alone dimmer mode

  • Short press M key, when display L-1~L-8, enter stand-alone dimmer mode.

  • Press ◀ or ▶ key to change dimmer mode number(L-1~L-8).

  • Each dimmer mode can adjust brightness independently.
    Long press M key for 2s, prepare for setup brightness.
    Press ◀ or ▶ key to setup brightness value(100-1FF).
    Long press M key for 2s, or timeout 10s, quit setting.

  • Enter stand-alone dimmer mode only when DMX signal is disconnected or lost.

MOKUNGIT S1-D1 AC Triac DMX Dimmer - 4

Stand-alone dynamic mode

  • Short press M key, when display P-1~P-2, enter stand-alone dynamic mode.

  • Press ◀ or ▶ key to change dynamic mode number(P-1~P-2).

  • Each mode can adjust speed and brightness.
    Long press M key for 2s, prepare for setup mode speed, brightness.
    Short press M key to switch two item.
    Press ◀ or ▶ key to setup value of each item.
    Mode speed: 1-10 level speed(S-1, S-9, S-F).
    Mode brightness: 1-10 level brightness(b-1, b-9, b-F).
    Long press M key for 2s, or timeout 10s, quit setting.

  • Enter stand-alone dynamic mode only when DMX signal is disconnected or lost.

Dynamic mode list

P-1 Name
P-2 0%,50%,100% light change in sequence
No. light fadein and fadeout

Restore factory default parameter

  • Long press ◀ and ▶ key for 2s, restore factory default parameter, display”RES”.
  • Factory default parameter: DMX decode mode, DMX decode start address is 1, reverse-phase control, 10% minimum brightness, dimmer mode number is 1, dynamic mode number is 1, output 100% level when no DMX input,disable automatic blank screen.