niko 25342 Swiss Garde 360 Plus Instruction Manual
- June 3, 2024
- niko
Table of Contents
Swiss Garde
360 Plus
Edition 06-2021
Art.-Nr. 25000, 25042, 25190, 25340, 25341, 25342
Motion detector 16 m, 360°
INSTALLATION INSTRUCTIONS
25342 Swiss Garde 360 Plus
Product description
The device detects the movements using a passive infrared sensor (PIR).
It reacts most sensitively to movements which are tangential to the monitored
area (1a).
Movements directly towards the detector have a reduced sensitivity of approx.
-50% (1b).
The detector does not switch until the brightness drops below the set value
(twilight threshold).
The switching duration is extended as long as movements are detected (1d).
Products which are indicated as accessories are not included in the scope of
delivery.
Application
The detector is suitable for indoor use for lighting control.
Outdoor applications require the use of the an IP55 housing (accessory).
Adhere to the following during installation:
– Install only on stable ceilings.
– Mask moving objects in the monitored area by covering up the lens.
– Do not place any lamps underneath or next to the detector at a distance of
less than 1 m away (2a).
– Do not install in direct cold (2b) or hot air flows (2c).
Safety notes
Ensure that the electrical lines are de-energised before installation.
Installation is only permitted by electricians in compliance with local
legislation.
Installation (4)
The detector is intended for ceilling installation at a height of 2 to 6 m.
The diameter Ø of the monitored area depends on the installed height (1c).
Install the detector as follows:
– Remove the front cover.
– Wire the detector according to item 5.
– Fasten the detector in the flush-mounting box.
– Configure device accrding to item 7.
– Mount the front cover.
Wiring (7)
The electrical circuit must be protected with a circuit breaker. The external push-button switches the current conduction line to the R terminal. Use push- buttons without a glow lamp and keep wires short.
Current conduction line | L |
---|---|
Neutral conductor | N |
Switching output relay | L’ |
External push-button (optional) | R |
Connection of loads
High inrush currents shorten the service life of the relay which is integrated
in the detector. Adhere to the technical specifications provided by the
manufacturer of the lamps and lighting equipment to avoid overloading the
relay (3a–b). To keep the circuit well-arranged, we recommend switching no
more than 3–4 detectors in parallel. If there
is an above-average number of switching cycles or in case of increased loads,
we recommend switching the load via an external contactor.
Configuration
The detector is ready for operation about 1min after mains connection.
Parameter changes must be made during operation eighter by adjusting the
device’s potentiometers or using the remote control (accessory).
Time: IME determines the delay after the last movement (5b). If the relay
output is wired to an automatic staircase switch, set TIME to pulse mode ( ).
Twilight threshold: LUX gradually sets the trigger threshold of the twilight
sensor between day mode and night mode (5a).
Range: SENS sets the detection range of the PIR sensor (5c).
External button
The light can be switched on at any time by the push-button.
After the last detection, the condition is still active for the set delay
time.
Display
The following statuses are indicated by the LED. Parameter changes can be made at the detector’s potetiometers or by using the remote control (accessory). When a parameter change is confirmed, the detector briefly switches off the relay output.
Status | LED indication | Duration |
---|---|---|
Start-up | ![niko-icon3](https://manuals.plus/wp-content/uploads/2022/12/niko- | |
icon3.png) | approx. 1 min, short flashes | |
Parameter change | 3x short flashes | |
Movement detection | 1x long flash |
Troubleshooting
The 16 m motion detectors are compatible with the 30 m lens (accessory).
If the range is insufficient, the lens can be replaced.
The switching output does not switch:
– Twilight threshold too high
– Check the lamp / fuse protection
The switching output switches too frequently:
– Reduce the range
– Cover the lens
– Twilight threshold too low
Technical data
Supply voltage | 230 V / 50 Hz |
---|---|
Switching power | max. 2300 W, 10 A (cos ϕ = 1.0) max. 1150 VA, 5 A (cos ϕ = |
0.5) LED 350W
Detection area| 360°
Detection range| max. 14 m at 3 m height
Lux level control| 5–2000 lx
Timer control| Pulse, 10 s to 20 min
Protection type| IP20
Temperature range| -20 to +40 °C
Dimensions (L x W x H) round cover| Ø 105×35 mm (Edition RA)
Dimensions (L x W x H) rectangular cover| 88x88x35 mm
Connection terminal| Ø 1.5 mm
Warnings regarding installation
The installation of products that will permanently be part of the electrical
installation and which include dangerous voltages, should be carried out by a
qualified installer and in accordance with the applicable regulations. This
user manual must be presented to the user. It should be included in the
electrical installation file and it should be passed on to any new owners.
Additional copies are available on the Niko website or via Niko customer
services.
CE marking
This product complies with all of the relevant European guidelines and
regulations. For radio equipment Niko llc declares that the radio equipment in
this manual conforms with the 2014/53/EU directive. The full text of the EU
declaration of conformity is available at www.niko.eu
under the product reference, if applicable.
Environment
This product and/or the batteries provided cannot be disposited in non-
recyclable waste. take your discarded product to a recognised collection
point. Just like producers and importers, you too play an important role in
the promotion of sorting, recycling and reuse of discarded electrical and
electronic equipment. To finance the rubbish collection and waste treatment,
the government levies recycling charges in certain cases (included in the
price of this product).
Support & contact
nv Niko sa
Industriepark West 40
9100 Sint-Niklaas, Belgium
www.niko.eu
+32 3 778 90 80
support@niko.eu
Niko prepares its manuals with the greatest care and strives to make them as
complete, correct and up-to-date as possible. Nevertheless, some deficiencies
may subsist. Niko
cannot be held responsible for this, other than within the legal limits.
Please inform us of any deficiencies in the manuals by contacting Niko
customer services at support@niko.eu.
PM25000_25042_25190_2534xR21242
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>