niko 25466 Swiss Garde 360 Presence Master Instruction Manual

June 3, 2024
niko

niko 25466 Swiss Garde 360 Presence Master

niko-25466-Swiss-Garde-360-Presence-PRODUCT

Product Description

The device detects the movements and the presence of persons using a passive infrared sensor (PIR). It reacts most sensitively to movements that are tangential to the monitored area (1a). Movements directly towards the detector have a reduced sensitivity of approx. -50% (1b). The detector does not switch until the brightness drops below the set value (twilight threshold). The switching duration is extended as long as movements (entire area 1d) or the presence of persons (presence area 1e) are detected. The detector detects an increase in daylight after switching on and, if there is sufficient daylight, switches off automatically. Products which are indicated as accessories are not included in the scope of delivery.

Application

The detector is suitable for indoor use for lighting control. Outdoor applications require the use of the an IP55 housing (accessory). Adhere to the following during installation:

niko-25466-Swiss-Garde-360-Presence-FIG-3

  • Install only on stable ceilings.
  • Mask moving objects in the monitored area by covering up the lens.
  • Do not place any lamps underneath or next to the detector at a distance of less than 1 m away (2a).
  • Do not install in direct cold (2b) or hot air flows (2c).

Safety notes

  • Ensure that the electrical lines are de-energized before installation.
  • Installation is only permitted by electricians in compliance with local legislation.

Installation

The detector is intended for ceilling installation at a height of 2 to 6 m. The diameter Ø of the monitored area depends on the installed height (1c). For a Master / Secondary application the Master must be installed in a position with medium brightness.

Install the detector as follows

  • Remove the front cover.
  • Wire the detector according to item 5.
  • Fasten the detector in the flush-mounting box.
  • Configure the device according to item 7.
  • Mount the front cover.

Wiring

niko-25466-Swiss-Garde-360-Presence-FIG-7

The electrical circuit must be protected with a circuit breaker. The external push-button switches the current conduction line to the R terminal. Use push- buttons without a glow lamp and keep wires short. A maximum of 10 secondary detectors can be connected to the S terminal. Keep wires short.

  • Current conduction line: L
  • Neutral conductor: N
  • Switching output relay: L’
  • External push-button (optional): R
  • Secondary detector (optional): S
Connection of loads

High inrush currents shorten the service life of the relay which is integrated in the detector. Adhere to the technical specifications provided by the manufacturer of the lamps and lighting equipment to avoid overloading the relay (3a–b). To keep the circuit well-arranged, we recommend switching no more than 3–4 detectors in parallel. If there is an above-average number of switching cycles or in case of increased loads, we recommend switching the load via an external contractor.

Configuration

The detector is ready for operation about 1min after the mains connection. Parameter changes must be made during operation eighter by adjusting the device’s potentiometers or using the remote control (accessory).

  • Time: TIME determines the delay after the last movement (5b). If the relay output is wired to an automatic staircase switch, set TIME to pulse mode ( ).
  • Twilight threshold: LUX gradually sets the trigger threshold of the twilight sensor between Z-day mode and 4-night mode (5a).
  • Range: SENS sets the detection range of the PIR sensor (5c).
  • Mode: MODE toggle between semi-automatic (SEMI-AUTO) and automatic mode (AUTO) (5d).

External button

SEMI-AUTO mode requires the connection of an external push-button as the light has to be switched on using the push-button (7a). In AUTO mode the external push-button (7c) is optional because the light is switched on automatically upon motion detection. The light can be switched on and off at any time by the push-button. Both conditions (ON and OFF) are extended with each detection. After the last detection, the condition is still active for the set delay time. Press and hold the push-button to switch the detector to the 6 h ON and 6 h OFF conditions. The conditions 6 h ON and 6 h OFF are cancelled before the time elapses by pressing the push-button again briefly:

  • Press push-button for 0.1–2.0 seconds ➡ automatic mode (ON / OFF)
  • Press and hold push-button for 2.0–4.0 seconds ➡ 6 h ON
  • Press and hold push-button for > 4.0 seconds ➡ 6 h OFF

Display

niko-25466-Swiss-Garde-360-Presence-FIG-12

The following statuses are indicated by the LED. Parameter changes can be made at the detector’s potentiometers or by using the remote control (accessory). When a parameter change is confirmed, the detector briefly switches off the relay output.

Troubleshooting

  • The 30 m presence detectors are compatible with the 16 m lens (accessory).
  • If the detection range is too high, the lens can be replaced with the 16 m lens.

The switching output does not switch

  • Twilight threshold too high
  • Check the lamp/fuse protection
  • Check the mode

The switching output switches too frequently

  • Reduce the range
  • Cover the lens
  • Twilight threshold too low

Technical data

niko-25466-Swiss-Garde-360-Presence-FIG-13

Warnings regarding installation

The installation of products that will permanently be part of the electrical installation and which include dangerous voltages should be carried out by a qualified installer and in accordance with the applicable regulations. This user manual must be presented to the user. It should be included in the electrical installation file and it should be passed on to any new owners. Additional copies are available on the Niko website or via Niko customer services.

Environment

This product and/or the batteries provided cannot be disposited in non- recyclable waste. take your discarded product to a recognized collection point. Just like producers and importers, you too play an important role in the promotion of sorting, recycling and reuse of discarded electrical and electronic equipment. To finance the rubbish collection and waste treatment, the government levies recycling charges in certain cases (included in the price of this product).

Support & contact

Niko prepares its manuals with the greatest care and strives to make them as complete, correct and up-to-date as possible. Nevertheless, some deficiencies may subsist. Niko cannot be held responsible for this, other than within the legal limits. Please inform us of any deficiencies in the manuals by contacting Niko customer services at [email protected].

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

niko User Manuals

Related Manuals