HINKLEY 32980 Carter Brass Glass Lantern Vintage Pendant Light Instruction Manual

June 3, 2024
HINKLEY

HINKLEY 32980 Carter Brass Glass Lantern Vintage Pendant Light Instruction Manual

Mounting Instructions

  1. Find a clear place to work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly

The construction of this fixture will be accomplished by first mounting the mounting strap to the junction box. Making all necessary electrical connections, assembling the main body of the fixture, mounting the fixture to the wall. and then installing the glass.

- Fixture Mounting

  1. Remove main mounting plate (A) from fixture back plate (B) by removing the four flat head screws (C) – see Drawing 1.
  2. Slide the wires from the junction box, through the large center hole, making sure slots (D) line up with the threaded holes (E) in the junction box.
  3. Using two 8-32 screws (F) attach the main mounting plate (A) to the junction box, making sure side of mounting plate (A) is square to ceiling.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

Make electrical connections from supply wire to fixture lead wires. Refer to instuction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to continue installation of this fixture. Haga las conexiones eléctricas desde el cable de alimentación a los cables conductores de la luminaria. Consulte la hoja de instrucciones (I.S. 18) y siga todas las instrucciones para realizar todas las conexiones de cableado necesarias. Luego, consulte esta hoja para continuar con la instalación de este accesorio. Effectuez les connexions électriques entre le fil d’alimentation et les fils de sortie du luminaire. Reportez-vous à la fiche de montage (I.S.18) et suivez toutes les instructions pour effectuer toutes les connexions de câblage nécessaires. Reportez-vous ensuite à cette fiche pour poursuivre l’installation de ce luminaire.

  1. Mount the fixture by sliding the back plate (B) over mounting plate (A) – see Drawing 1.
  2. Attach the back plate (B) to the mounting plate (A) using the screws (C)

Glass installation

wiring grounding instructions

SAFE TY WARNI NG: READ WIRIN G AND GR OUNDING INSTRUCTIO NS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSU LT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

Indoor Fixtures

  1. Connec t positi ve supp ly wir e (A ) (typical ly black or the smoo th, unma rked side of the two-conduc tor cord) to positi ve fi xture lead (B ) wit h ap propri ately sized t wist on connec tor – see Dra w ings 1 o r 2.
  2. Connec t nega ti ve supp ly wi re (C) (t ypica lly white or the ribbed , marked side of the two-conduc tor cord) to nega tive fi xture lead (D).
  3. Ple ase refe r to the grounding instructions below to complet e all electrical connec tion s

Outdoor Fixtures

  1. Connec t positi ve supp ly wir e (A) (typical ly black or the smoo th unma rked side of the two-conduc tor cord) to positi ve fi xture lead (B) wit h ap propri ately sized twist on connec tor — see Drawings 2 or 3.
  2. Connec t nega ti ve supp ly wi re (C) (t ypica lly white or the ribbed , marked side of the two-conduc tor cord) to nega tive fi xture lead (D).
  3. Cove r open end of connec tor s wit h silicone sealant to fo rm a wate rt ight seal. If installing a wall moun t fi xture, use cau lk to seal gaps between the fi xture mo unting p late (backpla te) and the wall. This will he lp prevent wa ter fr om en tering the out let box . If the wal l sur face is lap siding, use cau lk and a fi xture moun ti ng plat form specially.
  4. Ple ase refe r to the grounding instructions below to complet e all electrical connec tion s.

grounding instructions

Flush Mount

Flush Mount Fixtur es
For positive ground ing in a 3-wir e elect ri cal system, fasten the fi xture ground wir e ( E) (typ ically coppe r or green plasti c coated) to the fi xture moun ti ng strap (M ) wit h the ground screw ( S) – see D r aw in g 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung

Chain Hung Fixtur es
Loop fi xture ground wir e ( E ) (typically coppe r or green plast ic coa ted) unde r the head of the ground screw ( S ) on fi xture mo unting strap ( M ) and connec t to the l oo se end of the fi xture ground wire directly to the ground wir e of the building system wit h ap propri ately sized twist-on connec tors – see D r aw in g 2.

Post-Mount

Post-Mou nt Fixtur es
Connec t fi xture ground wir e ( E ) (typical ly copper or green plastic coa ted) to power supp ly ground wit h app ropri ately sized twi st-on connec tor inside post. Cove r open end of connec tor wi th silicone sealant to form a wate rt ight seal – see Drawing 3.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals