Panasonic S-3650PU3E Cassette Air Conditioner Instruction Manual
- June 3, 2024
- Panasonic
Table of Contents
Operating Instructions
Air Conditioner
Instruction Manual
S-3650PU3E Cassette Air Conditioner
INDOOR UNIT
4-Way Cassette
(Type U3)
Model No. S-3650PU3E, S-6071PU3E, S-1014PU3E
https://eu.datanavi.ac.smartcloud.panasonic.com/documents/
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
This booklet mainly mentions the safety-related regulatory matters. Regarding
the contents of the operation, please scan the matrix two-dimensional (2D)
barcode and refer to the detailed manuals.
Thank you for purchasing this Panasonic product.
This product is a commercial air conditioner indoor unit.
Installation Instructions attached.
Safety Precautions
The following symbols used in this manual, alert you to potentially dangerous
conditions to users, service personnel or the appliance:
WARNING
This symbol refers to a hazard or unsafe practice which can result in severe
personal injury or death.
CAUTION
This symbol refers to a hazard or unsafe practice which can result in personal
injury or product or property damage.
Prohibited matters
Matters to be observed
- Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
- This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
WARNING| This symbol shows that this equipment uses a flammable
refrigerant. If the refrigerant is leaked, together with an external ignition
source, there is a possibility of ignition.
---|---
CAUTION| This symbol shows type of flammable refrigerant contained in
the system.
CAUTION| This symbol shows that a service personnel should be handling
this equipment with reference to the Technical Manual.
CAUTION| This symbol shows that there is information included in the
Operating Instructions and/or Installation Instructions.
Important Information Regarding The Refrigerant Used
NOTE
Refer to the Installation Instructions attached to the outdoor unit.
WARNING
Confirm to authorized dealer or specialist on usage of specified
refrigerant type. Using of refrigerant other than the specified type may cause
product damage, burst and injury etc.
This air conditioner has no ventilator for intaking fresh air from outdoors.
You must open doors or windows frequently when you use gas or oil heating
appliances in the same room, which consume a lot of oxygen from the air.
Otherwise there is a risk of suffocation in an extreme case.
Never use or store gasoline or other flammable vapor or liquid near the air
conditioner — it is very dangerous.
Do not use this appliance in a potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your fingers or other objects into the air conditioner indoor or
outdoor unit, rotating parts may cause injury.
Information for Users on Collection and Disposal of Old Equipment and Used
Batteries
These symbols on the products, packaging, and/or accompanying documents mean
that used electrical and electronic products and batteries should not be mixed
with general household waste.
For proper treatment, recovery and recycling of old products and used
batteries, please take them to applicable collection points, in accordance
with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products and batteries correctly, you will help to save
valuable resources and prevent any potential negative effects on human health
and the environment which could otherwise arise from inappropriate waste
handling.
For more information about collection and recycling of old products and
batteries, please contact your local municipality, your waste disposal service
or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in
accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact
your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard
these items, please contact your local authorities or dealer and ask for the
correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case
it complies with the requirement set by the Directive for the chemical
involved.
If the refrigerant comes in contact with a flame, it produces a toxic gas.
For safety, be sure to turn the air conditioner off and also to disconnect the
power before cleaning or servicing.
Pull off the power plug from a receptacle, or switch off the breaker, or
switch off the power disconnecting mean to isolate the air conditioner from
the main power supply in case of emergency.
Dispose of according to national and/or local legislation.
This product must not be modified or disassembled under any circumstances.
Modified or disassembled unit may cause fire, electric shock or injury.
Do not clean inside the indoor and outdoor units by users. Engage authorized
dealer or specialist for cleaning.
In case of malfunction of this appliance, do not repair by yourself.
Contact the sales dealer or service dealer for a repair and disposal.
Provide a power outlet to be used exclusively for each unit, and a power
supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current
Device (RCDfor overcurrent protection should be provided in the exclusive
line.
Provide a power outlet exclusively for each unit, and full disconnection means
having a contact separation in all poles must be incorporated in the fixed
wiring in accordance with the wiring rules.
To prevent possible hazards from insulation failure, the unit must be
grounded.
Do not use modified cord, joint cord, extension cord or unspecified cord to
prevent overheating and fire.
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open flames, an operating gas appliance or an
operating electric heater).
Be aware that refrigerants may not contain an odour.
An unventilated area where the appliance using flammable refrigerants is
installed shall be so constructed that should any refrigerant leak, it will
not stagnate so as to create a fire or explosion hazard.
The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
After the unit is installed, never fail to ask the installer for the floor
space of the room where the unit is installed and the refrigerant charge
amount.
In case the unit or the room divider is changed, never fail to consult the
sales dealer or service dealer.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
Do not pierce or burn.
In cases that require mechanical ventilation, ventilation openings shall be
kept clear of obstruction.
WARNING
The appliance shall be stored in a room without continuously operating open
flames (for example: an operating gas appliance) and ignition sources (for
example: an operating electric heater).
Stop using the product when any abnormality/failure occurs and disconnect the
power plug or turn off the power switch and breaker.
(Risk of smoke/fire/electric shock) Examples of abnormality/failure:
- The ELCB trips frequently.
- The product sometimes does not start when turned on.
- The power is sometimes disconnected when the cord is moved.
- Burnt odor or abnormal noise is detected during operation.
- The body is deformed or abnormally hot.
- Water leaks from the indoor unit.
- Power cord or plug becomes abnormally hot.
- Fan speed cannot be controlled.
- The unit stops running immediately even if it is switched on for operation.
- The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.
Do not sit or step on the unit.
You may fall down accidentally.
CAUTION
This appliance is intended to be used by expert or trained users in shops, in
light industry and on farms, or for commercial use by lay persons.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
Keep the fire alarm and the air outlet at least 1.5 m away from the unit. Do
not cool or heat the room too much if babies or invalids are present.
Do not turn the air conditioner on and off from the power mains switch. Use
the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is
dangerous because the fan is rotating at high speed.
Do not touch the air inlet or the sharp aluminum fins of the outdoor unit.
You may get injured.
Do not stick any object into the FAN CASE. You may be injured and the unit may
be damaged.
NOTICE
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
- The English text is the original instructions. Other languages are translation of the original instructions.
Maintenance
WARNING
- For safety, be sure to turn the air conditioner off and disconnect the power before cleaning. (Otherwise, electric shock or injury may result because the fan is rotating at high speed.)
- Do not pour water on the indoor unit. (This may damage the internal components and cause an electric shock hazard.)
CAUTION
- Never use solvents or harsh chemicals. Also, do not wipe plastic parts using very hot water. (This may cause deformation or change in colour.)
- Some metal edges and fins are sharp. Be careful when you clean those parts. (Injury may result.)
- Use a firm stool or ladder when cleaning an indoor unit installed in high locations.
Air Filter Maintenance
Consult your dealer or service center when the (Filter) appears on the
display of the wired remote controller.
Timer Remote Controller| High-spec Wired Remote Controller| Wired Remote
Controller
---|---|---
Indoor unit (e.g. Type U3)
- The internal coil and other components of the outdoor unit must be cleaned periodically.
- Consult your dealer or service center.
Operation Mechanism
„ Heating performance
This air conditioner utilizes outside air for heating; its heating performance
reduces as outside temperature decreases.
→ In the event that heating is not sufficient, please use an additional
heating appliance.
„ Defrosting
This appliance may start defrosting operation to melt frost formed in the
outdoor unit.
-
Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow).
→“ ” (STANDBY) appears. -
Heating operation resumes after several minutes: The indoor unit fan remains stopped (or it will run at a very slow speed) until the indoor heat exchanger coil warms up sufficiently.
→ “ ” (STANDBY) appears. -
Defrosting is complete: The indoor unit fan starts operation.
→ “ ” (STANDBY) disappears.
„ ‘‘DRY’’ operation
- Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically.
- When the room temperature is more likely to reach the level that was set, the fan speed is set to ‘‘breeze’’ (light wind) automatically.
„ Should power failure occur while the unit is running
The unit will resume operation automatically. Operation settings prior to
power failure will be used.
NOTICE
Label (attached to the lid of electrical component box)
This air conditioner incorporates a biocidal product.
Ionized air generated by a device incorporated in the air conditioner
deactivates bacteria and viruses in the air, and on surfaces, and inhibits
mould growth on surfaces.
Active substances: free radicals generated in situ from ambient air or water
Specifications
Model Name | S-3650PU3E | S-6071PU3E | S-1014PU3E |
---|---|---|---|
Power source (Europe) | 220 – 230 – 240 V~ 50 Hz | ||
Power source (Oceania) | – | 230 – 240 V~ 50 Hz | |
Cooling capacity | kW | 3.6 | 4.5 |
BTU/h | 12,300 | 15,400 | 17,100 |
Sensible | kW | 3.2 | 3.7 |
Latent | kW | 0.4 | 0.8 |
Heating capacity | kW | 4.0 | 5.2 |
BTU/h | 13,600 | 17,700 | 19,100 |
**Cooling electric power input*** | kW | 0.024 | 0.026 |
0.100 | 0.110 | 0.120 | |
**Heating electric power input*** | kW | 0.022 | 0.024 |
0.095 | 0.105 | 0.115 | |
Sound pressure level | High | dB(A) | 30 |
Medium | dB(A) | 28 | 28 |
Low | dB(A) | 27 | 27 |
Sound power level | High | dB(A) | 45 |
Medium | dB(A) | 43 | 43 |
Low | dB(A) | 42 | 42 |
Corresponding language table
- 4-Way Cassette (Type U3)
- Model Name
- Power Source
- Cooling Capacity
- Sensible
- Latent
- Heating Capacity
- Cooling electric power input
- Heating electric power input
- Sound pressure level (High/Medium/Low)
- Sound power level (High/Medium/Low)
- In the case of nanoe™ X “OFF”
• Product Information
If you have problems or questions concerning your Air Conditioner, you will
need the following information. Model and serial numbers are on the nameplate.
Model No.—-
Serial No.—
Date of purchase—-
Dealer’s address—-
Phone number—–
Model No. / Serial No. / Date of purchase / Dealer’s address / Phone number
Panasonic Corporation
http://www.panasonic.com
© Panasonic Corporation 2019
Printed in Malaysia
Authorised representative in EU
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany
ACXF55-25410
DC0819-11019
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>