EUTRAC ONETRACK Track System Instruction Manual
- June 3, 2024
- EUTRAC
Table of Contents
EUTRAC ONETRACK Track System
Introduction
Warnings
All the described operations of this instructions page must be done by
specialized personnel only. Exclude voltage plant. Please respect national
installation regulations. The manufacturer allows to use only ONETRACK by
Eutrac parts in applications where its track system is used. These parts must
be installed according to the installation instructions. The company as a
manufacturer is not responsible for the safety and functioning of the ONETRACK
by Eutrac system if parts not belonging to it are used or if any deviation
from the installation instructions occurs. It is then the user’s
responsibility to ensure the electrical, mechanical and thermal compatibility
between ONETRACK by Eutrac system and the fixtures used with it. ONETRACK by
Eutrac tracks, its components and also the adapters can’t be used with
accessories without the Quality Mark. On ONETRACK by Eutrac tracks one can use
only ONETRACK by Eutrac connections. ONETRACK by Eutrac connections can be
used only with ONETRACK by Eutrac tracks. Do not exceed listed loading
indicated in the relevant section and respect fixing distances during the
track mounting. It is strictly forbidden to use any kind of solvent, glue,
oil, grease or cleaner in contact with ONETRACK by Eutrac system components.
The company is not responsible of any demage caused by the use of the
materials mentioned above.
The electrical connection to the mains can be carried out only with articles
575 2 1201 and 575 2 1202 or, alternatively, the track can be powered with
items 575 2 1208/1209/1210/1211/1212/ 1213/1214/1215/1216 under the following
conditions:
- using the same conductors adopted for the end power feeds 575 2 1201, 575 2 1202.
- Including a cable anchoring device, for suspended installations in which the power cable is accessible.
- The anchoring device is NOT required for ceiling-mounted installations.
The installer shall be fully responsible for the wiring of these items. Whenever any components are modified, the manufacturer shall be the subject responsible for the modification.
SURFACE INSTALLATION
1 – 575 2 110..
USE
CEILING FIXING
SUSPENDED FIXING
MAX LOAD
575 0 1217
575 2 1206
575 2 1208
575 2 1209 575 2 1210
575 2 1212 575 2 1213 575 2 1214 575 2 1215
575 2 1216
CUTTING
ADAPTERS
For all the details regarding ONETRACK by EUTRAC adapters read the QR code
PLEASE ENSURE THAT THE DATA BUS WIRING DOES NOT CREATE A RING STRUCTURE. A
FAILURE-FREE DATA BUS CANNOT BE ENSURED IF ONE IS PRESENT.
IF THE TRACK INSTALLATION REQUIRES THE USE OF “L”, “T” OR “X” -SHAPED JOINT,
IT IS POSSIBLE TO DISCONNECT THE DATA BUS IN THESE JOINTS TO AVOID CREATING A
RING STRUCTURES
DIRECTIVE 2012/19/UE (Waste Electrical and Electronic Equipment – WEEE) The product at the end of life must be disposed of and recycled in a designated collection point, cannot be treated as household waste. Details on the collection points available c/c local government office or the product retailer