justanswer Evaporative Emission Canister Purge Valve Instruction Manual

June 3, 2024
justanswer

justanswer Evaporative Emission Canister Purge Valve

justanswer-Evaporative-Emission-Canister-product-image

Removal

WARNING:
Do not smoke, carry lighted tobacco or have an open flame of any type when working on or near any fuel-related component. Highly flammable mixtures may be present and may be ignited. Failure to follow these instructions may result in serious personal injury.

  •  Do not carry personal electronic devices such as cell phones, pagers or audio equipment of any type when working on or near any fuel-related component. Highly flammable mixtures may be present and may be ignited. Failure to follow these instructions may result in serious personal injury.

NOTE:
Removal steps in this procedure may contain installation details.

  1. Disconnect the quick release couplings.
    Refer to: Quick Release Coupling (310-00A) .justanswer Evaporative Emission
Canister 01

  2. Disconnect the quick release couplings.
    Refer to: Quick Release Coupling (310-00A) .justanswer Evaporative Emission
Canister 02

  3. Disconnect the quick release coupling.
    Refer to: Quick Release Coupling (310-00A) .

    • Loosen the clamp and position aside the air cleaner outlet pipe.
      Torque: 42 lb.in (4.8 Nm)justanswer Evaporative Emission Canister
03
  4.  Disconnect the electrical connector.

  • Disconnect the quick release coupling. Refer to: Quick Release Coupling (310-00A) .
  • Remove the fastener and purge valve.
    Torque: 97 lb.in (11 Nm)justanswer Evaporative Emission Canister
04

Installation

  1.  To install, reverse the removal procedure.