justanswer Evaporative Emission Canister Purge Valve Instruction Manual
- June 3, 2024
- justanswer
Table of Contents
justanswer Evaporative Emission Canister Purge Valve
Removal
WARNING:
Do not smoke, carry lighted tobacco or have an open flame of any type when
working on or near any fuel-related component. Highly flammable mixtures may
be present and may be ignited. Failure to follow these instructions may result
in serious personal injury.
- Do not carry personal electronic devices such as cell phones, pagers or audio equipment of any type when working on or near any fuel-related component. Highly flammable mixtures may be present and may be ignited. Failure to follow these instructions may result in serious personal injury.
NOTE:
Removal steps in this procedure may contain installation details.
-
Disconnect the quick release couplings.
Refer to: Quick Release Coupling (310-00A) . -
Disconnect the quick release couplings.
Refer to: Quick Release Coupling (310-00A) . -
Disconnect the quick release coupling.
Refer to: Quick Release Coupling (310-00A) .- Loosen the clamp and position aside the air cleaner outlet pipe.
Torque: 42 lb.in (4.8 Nm)
- Loosen the clamp and position aside the air cleaner outlet pipe.
-
Disconnect the electrical connector.
- Disconnect the quick release coupling. Refer to: Quick Release Coupling (310-00A) .
- Remove the fastener and purge valve.
Torque: 97 lb.in (11 Nm)
Installation
- To install, reverse the removal procedure.