DiamaPro SYSTEM AS-2000 Air Scrubber Owner’s Manual
- June 3, 2024
- DiamaPro SYSTEM
Table of Contents
AS-2000
AIR SCRUBBER
OWNER’S MANUAL USER & MAINTENANCE BOOK
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
AS-2000 Air Scrubber
NOTICE
FOR PROFESSIONAL USE ONLY
WARNING
IMPORTANT SAFETY INFORMATION ENCLOSED.
READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THIS PRODUCT.
IT IS YOUR RESPONSIBILITY TO MAKE THIS SAFETY INFORMATION AVAILABLE TO OTHERS
THAT WILL OPERATE THIS PRODUCT. FAILURE TO OBSERVE THE FOLLOWING WARNING COULD
RESULT IN INJURY.
PLACING MACHINE IN SERVICE
Always install, operate, inspect and maintain this product in accordance with
all applicable standards and regulations (local, state, country, federal,
etc.).
- Always use proper gauge cord with correct connections.
- Be sure all cords are securely connected to the recessed male plug.
- Ensure an accessible emergency shutoff when your machine is connected to power. Make others aware of its location.
- Do not use damaged, frayed, or deteriorated electrical cords or connections.
- Do not leave machines in operation unattended for any reason.
- Keep all electrical connections clear of water or other liquid hazards.
- Always turn off and unplug your machine before performing any maintenance.
- Do not operate the machine while flammable or volatile liquids such as gasoline, diesel or jet fuel are present. Failure to do so can result in explosion.
- Keep work area clean, uncluttered and illuminated.
- Do not remove any labels. Replace any damaged labels.
USING THE MACHINE
-
Always wear protection when operating or performing maintenance.
-
Always use Personal Protective Equipment appropriate to the work being performed. This may include dust mask or other breathing apparatus,safety glasses, ear plugs, gloves, apron, safety shoes, hard hat and other equipment.
-
If applicable, prevent exposure and breathing of harmful dust and particles:
Some dust created by power sanding, sawing, and grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
– Lead from lead based paints,
– Crystalline silica from bricks and cement and other masonry products, and
– Arsenic and chromium from chemically treated lumber
Your risk from these exposures varies, depending on how often you do this type of work. -
Keep others a safe distance from your work area, or ensure they use appropriate Personal Protective Equipment.
-
This machine is not designed for working in explosive environments, including those caused by fumes and dust, or near flammable materials.
-
This machine is not insulated against electric shock.
-
Keep hands, loose clothing, long hair and jewelry away from the machines blower assembly and “Air Intake.”
-
To avoid accidental starting – ensure machine is on the “off” position before connecting to power.
-
Do not carry or drag the machine by the cord.
-
Do not operate or maintain the machine under the influence of medication, drugs, or alcohol.
-
Never use damaged or malfunctioning machines.
-
Do not modify the machine, safety devices, or accessories.
-
Do not use this machine for purpose other than those recommended.
-
Only use accessories recommended by DiamaPro Systems.
-
Whenever applicable, wear safety shoes, hard hat, safety goggles, gloves, dust mask and any other appropriate protective clothing in the work area.
-
Do no indulge in horseplay. Distraction can cause accidents.
-
Use only proper cleaning solvents to clean parts. Use only cleaning solvents which meet current safety and health standards. Use cleaning solvents in a well ventilated area.
-
Do NOT clean machine or any parts with diesel fuel or any other petroleum distillates.
-
Do not operate the machine with broken or damaged parts.
-
This tool is not designed for working in explosive atmospheres.
SAFETY
DiamaPro Systems – Negative Air Machines are highly efficient systems
designed to reduce airborne particulates. To insure proper operation, the
following safety precautions should be strictly adhered to:
-
Do not leave machine unattended when connected to a power source.
-
Turn OFF electric supply and disconnect from power source when not in use and/or before servicing.
-
Do not operate with damaged or malfunctioning parts. If the unit is not working as intended, return to an Authorized Repair and Service Center.
NOTE: Always replace worn or damaged components with genuine DiamaPro Systems parts. Failure to comply could result in equipment failure and will void warranty. -
Remove any loose clothing and adornments prior to operation.
-
Keep outer surfaces free of dirt and debris. Be sure all controls clean and functioning properly
-
Turn off power prior to any filter inspection and replacement
-
Do not operate unit with flammable or combustible liquids or gases present
-
Do not operate the machine in wet conditions. Failure to do so could result in electrical shock or death.
-
Never operate the unit if there is any possibility of contact with the blower wheel.
-
It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and efficient operating condition.
-
Stacking of machines is limited to three units. Do not house stacked machines in areas hotter than 100 degrees Fahrenheit. (Failure to comply will void warranty.)
DUST WARNING
Cutting, especially when DRY cutting, generates dust that comes from the
material being cut, which frequently contains silica. When dry cutting, be
sure to use a HEPA filtered dust collector.
Silica is a basic component of sand, quartz, brick clay, granite and numerous
other minerals and rocks. Exposure to excessive amount of such dust can cause:
-
Respiratory diseases (affecting your ability to breath), including chronic bronchitis, silicosis and pulmonary fibrosis from exposure to silica.
These diseases may be fatal; -
Skin irritation and rash; and
-
Cancer according to NTP and IARC
*National Toxicology Program, International Agency for Research on Cancer Take precautionary steps -
Avoid inhalation of and skin contact with dust, mist and fumes;
-
Wet cut when feasible, to minimize dust;
-
Wear and ensure that all bystanders wear appropriate respiratory protection such as dust masks designed to filter out microscopic particles. (See OSHA 29 CFR Part 1910.1200)
INTRODUCTION
Thank you for purchasing a DIAMAPRO® SYSTEMS product.
This manual provides information and procedures to safely operate and maintain
the AS-2000 For your own safety and protection from injury, carefully read,
understand, and observe the safety instructions described in this manual.
Keep this manual or a copy of it with the machine. If you lose this manual or
need an additional copy, please contact DiamaPro Systems®. This machine is
designed and built with user safety in mind; however, it can present hazards
if improperly operated and serviced.
Please follow the operating instructions carefully. If there are any questions
regarding operating or servicing of this machine, please contact DiamaPro
Systems®.
Disclaimer: DiamaPro Systems® and its affiliates take no responsibility
for any damage, injury or death resulting from the incorrect or unsafe use of
this product. Use of this product should be undertaken by competent persons
only. It is the operator’s responsibility to ensure that the following safety
procedures are followed. If you are unsure, do not operate this product.
GENERAL DESCRIPTION
The AS-2000 is a portable, electrically powered Air Filtration machine,
designed and manufactured by DIAMAPRO SYSTEMS®. The machines function is to
filter air and remove suspended airborne particulates.
This unit has a three stage filtering system. The Pre-Filter stage captures
the bulk of the dust and debris. The second stage utilizes a two-ply Ring
Filter that captures any dust and dirt able to penetrate the Pre-Filter. The
final stage is the 99.97% – 0.3 micron HEPA Filter or the 5 micron general
purpose filter. The HEPA filter is utilized in abatement work or areas where
an extremely high level of filtration is desired. The general purpose filter
is utilized when trying to reduce visible air born particulates that are
deemed non hazardous.
The AS-2000 requires a 110/115V – 20 Amp, single phase power source.
DO NOT USE CIRCUITS EXCEEDING SPECIFIED VOLTAGE. HIGHER VOLTAGE WILL DAMAGE
CONTROLS AND COULD CAUSE SHOCK OR FIRE HAZARD.
ROUTINE MAINTENANCE
Inspect the unit for any loose or damaged parts prior to use.
CAUTION: Be sure power supply is in the OFF position prior to inspection!
A. Clean the surfaces of the unit to remove accumulated dust or dirt. Do not
use petroleum distillates, solvents, or thinners as cleaning agents.
Remove any accumulated dust and dirt from control panel.
B. Periodic checks should be made of the filter brackets to ensure thumbscrews
and knobs are secure.
C. Filters should be checked daily and replaced if needed. This will help
ensure proper air flow and extend motor life.
D. Inspect ALL power connection. Be sure that the recessed plug is secure to
the panel. If recessed plug is not secured, electrical shock or shortage may
occur.
E. Inspect your power cords connections for breaks, scorched areas, melting,
oxidation, or signs of wear. If cord shows ANY of these signs, replace.
CAUTION: Do not tamper with or modify the blower housing, control panel,
drive motor, or wiring scheme. Tampering or modifications could result in
premature wear or failure and will void factory warranty
CONTROL DESCRIPTIONS
-
Power Switch
Switch used to turn on your AS-2000. Select either high or low settings depending on the desired volume of air to be filtered. -
Circuit Breaker
This is attached to the units main power supply to assist in protecting the blower motor from power surges. The circuit breaker also helps protect the operator against electrical shock or hazards. -
Differential Pressure Gauge
This is used to determine filter efficiency. The DPG measures negative pressure on the clean side of the filters. As the Filters load with dust and debris, the negative pressure will increase and move the needle of the DPG. A new filter will register 1.0-1.5” of water column. A fully loaded filter will register approximately 3.0-3.5” of water column. -
Barbed Fitting
Inlet used to measure pressure of surrounding ambient air. -
Male Recessed Plug
Firmly insert the female end of a proper gauge extension cord to power the machine.
CAUTION: A loose, corroded, ill fitted or damaged extension cord can cause pre-mature failure and void your warranty. -
Audible Alarm – (Optional Feature)
Audibly alerts the operator when filters are loaded or when air flow is greatly decreased. The alarm will sound once the pressure gauge reaches 2.8-3.2” of water column. -
Visual Light – (Optional Feature)
Visually alerts the operator when filters are loaded or when air flow is greatly decreased. The alarm will light once the pressure gauge reaches 2.8-3.2” of water column
AS-2000 CONTROL PANEL
PRIOR TO USE
A. Remove any excess dust/dirt from exterior housing and control panel.
B. Be sure the HEPA Filter and Pre-Filters are installed properly with a
positive seal.
C. Insure the unit is connected to a dedicated 20Amp, 110/115 volt circuit.
D. Make sure unit is safely positioned as not to impede any entrances or exits
of the work area.
E. If applicable, check exhaust port connections for tight seal.
CAUTION: Insure your power cord is securely attached to the male recessed
plug. If any movement or play is detected, change power cord immediately! If
connection remains loose, immediately replace the male recessed plug.
OPERATION
A. When utilized in containment, the AS-2000 should be positioned a minimum
distance away from the entrance and located towards the center of the
containment.
B. When using a HEPA filter, insure the filter is correctly installed and
sealed. Anchor and secure the filter utilizing the supplied retaining
brackets.
C. Install the Ring Filter and Pre-Filter pad into unit.
D. Position the unit on a flat level surface and secure the casters using the
lock feature.
E. Insert the female end of your 20 amp rated, UL listed cord, into the male
recessed plug on control panel.
F. To begin operation, depress the power switch to either the low or high
position. Locate the differential pressure gauge located on the control panel.
The gauge will register between 1.0” – 2.5” of water column. This is the
initial reading when filters are new and unused. This reading will
incrementally increase as filters become loaded with dust and debris. When the
gauge reaches 3.0” – 3.4” of water column; either one or all of the filters
are loaded and in need of replacement.
G. Pressing the power switch to the left will operate the unit in “Low” mode
equivalent to 1200 CFM.
H. Pressing the power switch to the right will operate the unit in “High” mode
equivalent to 2100 CFM.
REPLACEMENT OF FILTERS
The work atmosphere will impact the frequency of filter replacements. As
filters begin to load, the reading of the pressure gauge will increase
incrementally. When the Pressure gauge reads 3.0” – 3.4” or when airflow is
greatly reduced, check the condition of filters.
CAUTION: If applicable, wear personal protective equipment during filter
replacement. Please observe all Federal, State, and Local regulations
regarding the handling and disposal of hazardous materials.
PRE-FILTER REPLACEMENT
A. Set the power switch (diagram #20.1, item #3) to the off position.
Disconnect power supply.
B. Remove Black Filter Door (diagram #20.1, item #10) to expose the filters.
C. Reach in and remove the Pre-Filter (diagram #20.1, item #18).
Dispose of Pre-Filter accordingly.
D. Replace the discarded Pre-Filter with a new Pre-Filter.
E. Reinsert the Black Filter Door.
F. Insert the female end of your power cord into the Male recessed plug
(diagram #20.1, item #1), and set the power switch to the “High” position. If
the reading on the pressure gauge exceeds 3.0” – 3.4” of water column, the
Ring Filter (diagram# 20.1, item #17) should be inspected.
RING FILTER REPLACEMENT
A. Follow steps A-D listed above referencing Pre-Filter replacement.
B. Reach in and remove the Ring Filter (diagram# 20.1, item #17).
Dispose of Ring Filter accordingly.
C. Replace the discarded filter with a new unused Ring Filter.
D. Reinstall the Pre-Filter.
E. Reinsert the Black Filter Door.
F. Insert the female end of your power cord into the male recessed plug
(diagram #20.1, item #1), and set the power switch to the “High” position. If
the reading on the pressure gauge exceeds 3.0-3.4” of water column, the HEPA
or General Purpose Filter should be inspected.
HEPA/GENERAL PURPOSE FILTER
A. Follow steps A-D listed above for Ring Filter replacement.
B. Locate the bracket thumbscrews (diagram #20.1, item #12). Loosen the four
bracket thumbscrews by turning them counter clockwise.
C. With all four thumbscrews loose, push the top of the filter brackets
(diagram #20.1, item #11) inward towards each other, and remove from the front
of the unit.
D. Firmly grasp the right and left sides of the HEPA or General Purpose Filter
(diagram #20.1, item #16), and pull the filter directly towards you.
Remove the used filter and dispose of accordingly
E. Carefully inspect the replacement HEPA/General Purpose Filter gaskets for
cracks, gaps or defects Any defective gaskets must be replaced.
F. The HEPA and General Purpose Filters have two sides; one side has a gasket,
the other does not. Insert replacement HEPA or General
Purpose Filter, gasket side first, into machine and press firmly against the
housing’s internal rib.
G. Reinstall the filter brackets. Once the brackets are installed, turn the
thumbscrews clockwise until tight. This will secure the main filter.
H. Reinstall Ring Filter and Pre-Filter. (Reference Pre-Filter and Ring Filter
Replacement).
I. Reinsert the Black Filter Door.
WIRING DIAGRAM
PARTS BREAKDOWN
Ref. | Part No. | Description |
---|---|---|
1 | DP-AS-MRPLUG | Male Recessed Plug |
2 | DP-AS-BREAK | Breaker |
3 | DP-AS-POWERSWITCH | Power Switch |
4 | DP-AS-2000-PRESSUREGAUGE | Pressure Gauge |
5 | DP-AS-PRESSUREFITTING | Barbed Pressure Fitting |
5A | DP-AS-DWIRENUT | Dome Wire Nut |
6 | DP-AS-2000-BLOWERHW | Blower Housing & Wheel |
7 | DP-AS-2000-BLOWERMOTOR | Blower Motor |
8 | DP-AS-2000-CAPACITOR | Capacitor |
9 | DP-AS-2000-BLOWERASSEMBLY | Blower Assembly Complete |
10 | DP-AS-2000-POLYDOOR | Black Poly Door |
11 | DP-AS-2000-FILTERBRACKET | Filter Brackets |
12 | DP-AS-2000-THUMBSCREW | Thumbscrews |
13 | DP-AS-2000-WHEELRIGID | Wheels, Rigid |
14 | DP-AS-2000-WHEELSWIVEL | Wheels, Swivel |
16 | DP-AS-2000-HEPA | Hepa Filter (2000CFM) |
16A | DP-AS-2000-GENFILTERFRAME | General Filter Frame |
16B | DP-AS-2000-GENERALFILTER | General Purpose Filter |
16C | DP-AS-2000-GENERALCONVERSIONKIT | General Purpose Conversion Kit |
(Includes Parts 16A & 16B)
17| DP-AS-2000-RINGFILTER| Ring Filter
18| DP-AS-2000-PREFILTER| Pre-Filter
19| DP-AS-2000-ALARM| Audible/Visual Alarm (optional)
ITEMS NOT PICTURED
Part No. | Description |
---|---|
DP-AS-2000-NEGAIRHOUSING | Negative Air Housing |
DP-AS-2000-INTAKEPOLYDOOR | 12” Intake Black Poly Door |
DP-AS-FOAMSEALING | Foam Sealing Strips |
DP-AS-DPSWITCH | Differential Pressure Switch |
DP-AS-DPSWITCHCONNECTOR | Tee Connector to Differential Switch |
DP-AS-DPSWITCHREDUCER | Reducer Fitting to Differential Switch |
DiamaPro Systems®
3343 Peachtree Road NE
Suite 145 #24
Atlanta, GA 30326
470-977-2323
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>