AIROLITE SCH601MD Flange/Sleeve with VCD-40 Damper Installation Guide

June 3, 2024
AIROLITE

Document 474791
SCH601MD
Flange/Sleeve Installation with VCD-40 Damper Florida Product Approval No: FL10093
Miami-Dade NOA No.: 17-0919.07
Maximum Wind-load: 150 PSF

SCH601MD Flange/Sleeve with VCD-40 Damper

Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions will result in voiding of the product warranty and may result in personal injury and/or property damage.

Maximum Size and Installation Information

Model SCH601MD with VCD-40 is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in accordance with the installation instructions shown herein. Model SCH601MD with VCD-40 is qualified for installation within concrete/masonry, steel stud, structural steel or wood framed building conditions. Model SCH601MD with VCD-40 is structurally calculated to withstand positive and negative wind-loads up to 150 PSF. The maximum single section rough opening width is 36.538 in. The maximum single section rough opening height is 144.788 in. While the maximum rough opening height is limited to 144.788 in., the rough opening width is limited to 1,000 in. as multiple sections may be installed side by side in accordance with installation instructions.

Building Condition/Substrate Limitations

  • All wood substrate shall be G= 0.55 density or better
  • All metal stud substrate should be min. 16 Ga. FY= 50 KSI
  • All structural steel substrate shall be min. 0.25 in. thick FY= 36 KSI
  • All concrete substrate shall be min. 3000 PSI
  • Concrete masonry shall be ASTM C90, Type II, 2000 PSI, grout-filled

Single Section

Multiple Sections
Height ≤ 96 ½ 

Multiple Sections
Height > 96 ½ ≤ 144 ½

Single Section

6 SCH601MD Flange/Sleeve Installation with Damper
Multiple Sections
Height ≤ 96 ½

Multiple Sections
Height > 96 ½ ≤ 144 ½

As a result of our commitment to continuous improvement, Airolite reserves the right to change specifications without notice.

P.O. Box 410, 525 Western Road, Schofield,
WI 54476-0410 USA 715.841.8757
fax 715.841.8773
www.airolite.com
474791
SCH601MD Flange/Sleeve Installation with Damper, Rev. 2, 12-18
Copyright 2018 © The Airolite Company LLC