ducasa AVANT-DGi+ Thermal Electric Radiator Instruction Manual
- June 3, 2024
- ducasa
Table of Contents
AVANT-DGi+ Thermal Electric Radiator
Manual AVANT- DGi+ EN v28 · E1400297 · 20220421
AVANT-DGi+ AVANT-DGi+ L
Thermal Electric Radiator Operating and Installation Instructions (Read these
instructions carefully and retain for future reference)
MODE CONFIG. PROG.
MODE
CONFIG. PROG.
Models: AVANT-DGi+ 350 AVANT-DGi+ 500 AVANT-DGi+ 750 AVANT-DGi+ 1000 AVANT-
DGi+ 1250 AVANT-DGi+ 1500 AVANT-DGi+ 1800 AVANT-DGi+ 950 L AVANT-DGi+ 1425 L
Amazon Alexa and Google Home compatible
NOTE A qualified electrician must carry out the electrical installation of
this radiator. The electrical installation must comply with current UK
regulations. Any claim on the warranty could be invalid
if these requirements have not been met.
CONTENT
TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .5 GENERAL INFORMATION. . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . .5 INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .6 CONTROL OPTIONS . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .8 OPERATING INSTRUCTIONS . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Switching ON (Master SWITCH) . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .9 Switching OFF (Master SWITCH) .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . .9 Stand-by function . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Using with smartcomand tevolve . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .9
Connecting to the smart command tevolve app . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . 9 Geolocation. . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . 10 Using without smartcommand tevolve . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .10 Mode operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Setting Programme and Clock . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Adjust Programmed
Temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . 11 Keypad Locking (Anti-Tamper). . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 11 Advanced Settings . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
QUICK GUIDE TO MANUAL PROGRAMMING . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . .13 ECODESIGN TABLE. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
MAINTENANCE AND CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .16
2
IMPORTANT SECURITY INFORMATION
· This appliance can be used by children aged 8 years and above and persons
with reduced physical, sensory or mental abilities or lack of experience and
knowledge, if they have been given supervision or appropriate training
regarding the use of the device in a safe way and they understand the dangers
involved.
· Children should not play with the appliance. Cleaning and maintenance should
not be performed by unsupervised children.
· Children under 3 years should be kept out of reach of the appliance unless
they are constantly supervised.
· Children between age 3 and younger than 8 years old should only turn on /
off the device whenever it has been placed or installed at its normal
operating position provided they are supervised or have received instructions
concerning use of the appliance safely and understand the risks that the
device has. Children from 3 years and under 8 years old should not plug in,
regulate, clean the appliance or perform maintenance.
· Warning: Some parts of this product can become hot and cause burns. Pay
particular attention when children and vulnerable people are present.
· Heaters must be installed correctly following the specific requirements of
the Installation Instructions section below.
Warning: in order to avoid over heating the unit, do not cover the heaters.
This symbol “DO NOT COVER”, is placed on the heater as a reminder to the user.
ATTENTION:
· The heaters must not be covered by clothing, containers or any other objects
that may block the air ventilation.
VERY IMPORTANT:
The “OFF” indicator shown on the heater’s control panel does not mean
disconnection of the heater from the power supply and should be understood as
a standby condition. To ensure the heater is completely off and without access
to the power supply, it is recommended to disconnect it from the power supply
by removing the fuse from the spur outlet. Alternatively, change the
mechanical switch on the side of the heater to “OFF”. · The unit must be
placed away from flammable objects and children must not be left
unattended when the heater is heating. · The heater should not be located
underneath any electrical connection. · The electric supply line should be
protected with a high sensitivity differential device
(RCBO). · Do not use the heater to dry clothes. · Heaters must not be
installed in places where there are risks of splashes such as next to
bathtubs, sinks, etc. · If the power cord is damaged, it must be changed by
the manufacturer, its after-sales
service or persons qualified to do so, to avoid possible danger · Anyone who
is in the bathtub or shower should not have access to the switches or other
power operation devices. Always keep at least 0.6m (UK) or 3.0m (Ireland)
between the radiator and the bath or shower. (UK: Outside zone 2, Ireland:
Outside zone 3) · The radiator must be installed so that around the radiator
there is sufficient space for proper circulation of hot air, with a minimum
distance of 150 mm to curtains, furniture, etc
3
· All repairs where required must be completed by the manufacturing company or
by special authorised staff.
· If the heater is sold without cable and plug or any other disconnecting
method, the installer must incorporate a disconnecting device taking into
account the specific regulations that apply.
· This heater has been designed and created as a fixed heating device unless
it’s being used with the optional feet and castor/pad set and must be used for
this purpose only.
· If being wall mounted, the heater must be mounted using the brackets
supplied with the heater.
· Do not place the heater directly on the floor. · Make sure that the wall
where the heater is going to be mounted is suitable to bear the
heater’s weight. · Use the correct fixing for the type of wall the heater is
to be mounted onto. · Make sure that the electrical power supply corresponds
to the information indicated on
the heaters rating label. · The heater must be levelled correctly both
vertically and horizontally. · When the heater is operational, the power cord
must be totally unrolled and must not
touch the surface of the unit. · Do not operate the heater with wet hands. ·
Before undertaking any type of maintenance, ensure that the heater is
disconnected
from the power supply by removing the fuse from the spur outlet.
4
TECHNICAL DATA
Model
Number Power Of Fins Rating (W)
Size (mm)
Net Weight (Kg.)
Fuse Rating
Class
Avant-DGi+ 350
3
Avant-DGi+ 500
4
Avant-DGi+ 750
6
Avant-DGi+ 1000
8
Avant-DGi+ 1250
10
Avant-DGi+ 1500
12
Avant-DGi+ 1800
12
Avant-DGi+ 950 L
10
Avant-DGi+ 1425 L 15
350
340 x 580 x 100
6.9
500
420 x 580 x 100
8
750
580 x 580 x 100
12
1000
740 x 580 x 100
16
1250
900 x 580 x 100
20
1500
1060 x 580 x 100
24
1800
1060 x 580 x 100
24
950
900 x 340 x 100
20
1425 1300 x 340 x 100
26
5 Amp.
I
5 Amp.
I
5 Amp.
I
10 Amp.
I
10 Amp.
I
10 Amp.
I
10 Amp.
I
10 Amp.
II
10 Amp.
II
GENERAL INFORMATION
The Avant DGi+ has a special cast aluminium body specifically designed to
assure the maximum rate of heat radiation; the air circulation channels
provide a very efficient convection effect.
A unique manufacturing process provides bubble free filling so that the fluid
delivers warmth from the heating element in a totally uniform way, ensuring
that the entire surface of radiator provides comfortable heat.
A monotube heating element ensures maximum heat output.
Designed and fabricated in accordance with EN 60335-1, EN 60335-2 and EN 55014
(regulations for domestic appliances)
Standard colour White (RAL 9016) Wall mounted (by quick fixing system) Bi-
metallic thermal cut-out Overheat protection Key-pad locking (anti-tamper) NTC
electronic sensor Fitted with mains power cable approximately 1450mm long
(without a plug)
5
INSTALLATION INSTRUCTIONS
Electrical Connection
A qualified electrician must carry out the electrical installation of this
radiator. The electrical installation must comply with the current UK
regulations. Any claim on the warranty could be invalid if these requirements
have not been met.
The radiator requires a 230V 50/60Hz power supply.
Connecting wires: Brown: Live Blue: Neutral Yellow-Green: Earth NOTE: The
Avant-DGi+ 950 L and Avant-DGi+ 1425 L are double insulated and do not require
an earth
cable
The connecting wires must be of the appropriate section, in regards to the
length of cable, type of cable and power rating of the radiator.
The radiator must be connected into a fused connecting box or a plug fitted
with an appropriate sized fuse for the radiator see Technical Data on Page
3.
We recommend that the connecting box is positioned 10cm to the right of the
radiator and at a height recommended by current UK regulations.
According to regulations, the radiator must be connected to the power supply
by means of an all-pole circuit breaker with a contact gap of at least 3mm or
by a thermal-magnetic circuit breaker.
Location
The ideal place to site the Ducasa radiator is as close as possible to coolest
wall in the room but it is not recommended to site the radiator on un-
insulated exterior walls, in this case, the part of the wall behind the
radiator should be insulated.
In bathrooms, the radiators must not be sited inside the protected areas. The control unit switches must not be reachable, directly or indirectly, by a person in the bath / shower or using the wash basin.
The radiator, under no circumstances, should be installed below an electric power point. Choose the location of the radiator in respect of the minimum distances that are indicated in Figure A.
window sill
150mm. min. unobstructed space each side
150mm.
150mm. Fig. A Note: If the window sill protrudes less than 20mm the gap above
the heater can be disregarded.
6
Mounting The Radiator
Place the radiator on the floor, as shown in Figure 1a. For radiators with 4,
6 and 8 elements position the brackets supplied with the radiator between the
first and second element (figure 1b). For radiators with more than 9 elements,
the bracket should be placed between the second and third element (figure 1b).
Fig. 1a
Fig. 1b
MODE
CONFIG. PROG.
MODE
CONFIG. PROG.
MODE
CONFIG. PROG.
MODE
CONFIG. PROG.
Place the supports between the elements as shown in Figure 2a, mark points on the walls through the fixing holes as shown in Figure 2b. This determines the spacing of the supports. Fix the supports to the wall with plugs and screws. Be sure that the supports are mounted in the correct position.
Fig. 2a
Fig. 2b
Lift the radiator and hang it on the supports, as Figures 3a and 3b.
Fig. 3a
Fig. 3b
7
As soon as the radiator is hanging on the supports press on the locking plate
until a click is heard. See Figure 4. The radiator is now installed.
Fig. 4
UNLOCKED
LOCKED
CONTROL OPTIONS
The Avant DGi+ is designed to be used in conjunction with the
system and App,
providing total control of your heating system from anywhere in the world via the internet. The
App is available for both Android and iOS devices and offers the ultimate in control and energy
monitoring.
Search for “Tevolve” on the either the Google Play Store or the Apple App Store. Scan this QR code to access to the download.
It is also possible to programme each radiator individually without the App by using the built
tevolve app heattend
in controls and screen. This may be convenient for single heaters however we recommend
the
Gateway to control multiple heaters.
The Avant DGi+ is also compatible with Amazon Alexa and Google Home via the
System and App.
For instructions on how to link them, visit
https://ducasa.co.uk/smartcommand/voicecontrol
8
OPERATING INSTRUCTIONS
SWITCHING ON (MASTER SWITCH)
The control is based on four buttons and an LCD display.
Once the radiator has been mounted on the wall and correctly connected to the
main electricity power supply, press the main On-Off switch on the right hand
side of the radiator.
After around 3 seconds the screen will show various information and the
radiator is ready to work.
Programmed hours
Days of the week SWITCHING OFF (MASTER SWITCH)
Desired temperature
Radio paired icon To switch off the radiator press the main On-Off
switch on the right hand side of the radiator. The
LCD screen will be blank and the radiator will lose
Heating indicator connection with the
Gateway.
Current Mode (AUTO, MANUAL, OFF)
MODE
CONFIG. PROG.
Increase
Decrease
Mode/OK
AUTO / MANUAL /OFF
CONFIG PROG
Ducasa DGi+ Radiator Controls
STAND-BY FUNCTION
Press the Mode/OK button
until the
symbol is
present as shown in the
following screen.
When the radiator is in
Stand-by Mode it will retain
programmes and continue
to communicate with the
Gateway.
To switch the radiator On again, press the MODE
button to choose programme mode
or manual
mode
you will see the following screens:
USING WITH SMARTCOMAND TEVOLVE APP
master switch
Connecting to the smart command tevolve app
To use your Avant DGi+ via the
App you must first connect and register your
Gateway . To do this follow the
instructions in the gateway manual.
Ensure you have downloaded and logged into the
App
using your user name and password, then press the + icon
Smart Command tevolve
Friday 19th Nov 2021, 11:29
on the home screen, and follow
the on-screen instructions.
Please Note: Paired devices
will show in the order they were
added onto the App and will be
called Radiator1, Radiator2
etc.
We
highly
recommend No devices were found in this home. To add a new one click on the button with the
renaming each radiator as they
symbol .
are paired to avoid confusion.
To do this select the paired
9
radiator and press the settings icon where you
can rename it.
Your Avant DGi+ is now ready to be controlled
from the
App.
If the Avant DGi+ has been linked to the
Gateway and for some
reason communication is lost, the Link icon
disappears and the antenna starts flashing on
the Avant DGi+ screen. It will continue to operate
in the mode it was in prior to losing communication.
If you don’t have the access to the
App or are unable to pair using the method
above , press the Link button on the Gateway 3
for 3 seconds.
orange green
USING WITHOUT SMARTCOMMAND TEVOLVE APP
Mode operation
To assist with programming the LCD screen is backlit and will stay illuminated
for approximately 10 seconds after the last button is pressed.
When the radiator is operational and the room temperature is lower than the
set temperature the heating symbol will be shown indicating that the radiator
is producing heat. When the room temperature equals or is above the set
temperature the heating symbol will not be present indicating
the radiator is not producing heat. The following screens show OFF, AUTO and
MANUAL modes. To chose diferent modes press MODE/OK button.
Once the orange LED starts to flash, press the CONFIG button on the Avant DGi+
and press the +/- button until the RF icon flashes. Then press OK
`Link’ together with an antenna icon will appear in the top right of the
screen.
Your Avant DGi+ is now
connected to the
Gateway.
Please Note: Once the
Gateway’s link button is pressed you have one
minute to add a heater. When the heater has
been added, you have one minute to add a further
heater without pressing button 3
Geolocation
This mode allows your
system to reduce the set temperature by a number
of degrees that is configured for each device from
the App when you are away from home. The
default is 2 degrees.
Geolocation is activated from the
App within the Homes setting. If activated,
all connected
devices in
the house will use this feature and AWAY will be
shown on the Avant DGi+ display.
If any button is pressed
on any connected
device, all devices in the
house will exit Geolocation mode for 2 hours, unless it’s turned back on
again.
When the radiator is in AUTO mode the temperature can be changed by pressing
the +/buttons. This change will remain active until the next programmed change
or until midnight when the temperature will revert to the preset value.
When in MANUAL mode, use the +/- buttons to adjust the temperature
Setting Programme and Clock
To start programming press and hold CONFIG/PROG button for 3 seconds and the
following screen will appear:
Programming starts on Monday at 00:00 and is set by choosing the required Mode
for each hour of the week. Use the OK button to choose between Comfort ,
Economy or Frost Protection modes. On the screen programme hours will show two
blocks for Comfort, one block for Economy and no blocks for frost protection).
After choosing the mode press the +/- buttons to select the next hour to be
programmed. When a full day has been programmed the screen moves to the next
day.
Once each day of the week has been programmed the clock must be set.
Press the CONFIG button to exit from programming screen and enter the time
setting screen.
To select the day of the week (1=Mon, 7=Sun) press +/- buttons and confirm
with the OK button. Next select the hour, confirm with OK and then select the
minutes and confirm pressing OK once more.
If a radiator is paired with a Gateway, time setting is not required as it
10
recognises the system’s time automatically.
Adjust Programmed Temperatures
Adjusting temperature in the following way will
only effect the temperatures used for programmed
modes.
To change these set up
temperatures press
the
CONFIG button and the
following screen appears:
When the temperature setup icon starts flashing, press OK to scroll through each mode.
setting by pressing OK. The advanced settings are:
C1-> Choose ºF or ºC C2->Choose type of thermostat accuracy C3-> Temperature
Compensation C4-> Firmware version C5-> Open Window detection C6-> Eco-Start
Degrees Fahrenheit or Celsius (C1)
Select ºC or ºF with the +/- buttons and confirm with OK button
Press the +/- button to change the temperature of each mode then press OK to
confirm and go to the next MODE to exit temperature setup, press CONFIG.
KEYPAD LOCKING (ANTI-TAMPER)
The Avant DGi+ can be locked to prevent any unauthorised person (children,
people in public places, nurseries, offices, hotels etc.) altering the
settings of the radiator. To lock the keypad press and hold the +/- buttons at
the same time for 3 seconds until “bloc” appears on the screen. Any button
presses will be ignored and “bloc” will be displayed on the screen.
To unlock keyboard, once again press and hold the +/- buttons for 3 seconds
until the word `bloc’ disappears.
When the Avant DGi+ is locked the radiator will still receive communications
from the
Gateway.
ADVANCED SETTINGS
To enter the advanced settings mode, press CONFIG while the radiator is in one
of the main modes (OFF, AUTO, MANUAL). The following screen will appear:
Type of Thermostat Accuracy (C2)
This setting shows the type of thermostat accuracy currently being used. There
are 5 types of accuracy PID, hysteresis of 0.25ºC, hysteresis of 0.35ºC,
hysteresis of 0.50ºC and hysteresis of 0.75ºC.
To change the type of accuracy press +/- button and confirm your selection by
pressing the OK button. The screens shown are:
Temperature Compensation (C3)
This setting is used to balance two radiators in the same room or to sync the
Avant DGi+ with a thermostat. It will alternate between the temperature
compensation (offset) and the measured temperature with offset applied. Alter
the offset with the +/- buttons and confirm with OK.
Temperature compensation can be adjusted up to +/- 3ºC
Now press the CONFIG button for 5 seconds and C1 appears on the screen.
To scroll through the advanced settings (C1 to C6) use the +/- buttons and
choose the required
11
Firmware Version (C4)
It shows internal software installed in the electronics.
Open Window detection (C5)
In order to save energy, if a window opens and causes a sudden drop in
temperature the heater will stop heating. If the heater is heating, it will be
disconnected for 30 minutes and shows the Open Window icon on the display.
By default this function is deactivated. To change the status of the function,
press the +/- button and then press ok to confirm.
By default this function is deactivated.
To change the status of the function, press the +/- button and then press ok
to confirm.
If this function is active then will be shown on the LCD screen.
This function is only active while in AUTO mode. If the heater is reset, all
previous Eco-Start data will be deleted.
This function detects a temperature drop of 0.6ºC every minute over a period 4
minutes.
The heater will restore normal function in any of these situations:
· After 30 minutes · If the temperature increases by 0.2ºC for 1
minute from the point of activation. · Pressing any button on the Heater
Radiator Reset
Resetting the radiator will return all settings
to the factory defaults and will also delete any
`pairing’ with a
Gateway. To
activate the RESET feature press the OK button
and the CONFIG button for 10 seconds. The
following screen will appear:
To confirm the reset, press OK again, to cancel the RESET press any other button.
Eco-Start (C6)
With this feature activated the radiator will learn what time it should switch
on to achieve the required room temperature at your programmed time.
The heater will monitor the room temperature over a rolling 10 day period to
establish how quickly the room reaches temperature and uses this information
to switch the heater on at the correct time.
By reaching the required temperature at the set time and not before, energy
use and running costs are reduced.
Factory Defaults
· Working mode: OFF · Comfort Temp : 19ºC · Economy Temp : 17ºC · Frost
Protection Temp : 5ºC · Manual Mode Temp: 19ºC · Temperature Compensation: 0ºC
· No RF paired network · Temperature units ºC · Control type: PID · Default
Programme: All Economy · Open Window detection OFF. · Eco-Start OFF.
12
Ducasa Avant DGi+
QUICK GUIDE TO MANUAL PROGRAMMING
The Avant DGi+ & Vitro-i+ radiator is programmed by using heating `modes’. The
modes are set for each hour of the week, starting from midnight on Sunday
The days are numbered 1 to 7, with 1 being Monday and 7 being Sunday
Comfort
The `modes’ are:
Economy
Frost Protection
There are 3 steps to programming your heater; 1.Programming the Modes 2.Setting the Clock 3.Setting the Temperatures
Programming the Modes
Press Prog / Config for 3 Seconds Press OK to choose the mode and +’ to confirm for each hour of each day If you make a mistake press
-‘ to go back When you are happy the modes are
correct press to move onto setting the clock
Setting the Clock
Use +/- to select the current day, 1 =Mon 7=Sun then press OK
Use +/- to set the hour then press OK
Use +/- to set the minute When you are happy the clock is correct press to
move onto setting the temperatures
Setting the Mode Temperatures
Use +/- to select then press OK
Use +/- to set the comfort temperature then press OK
Use +/- to set the Economy temperature then press OK
Use +/- to set the Frost Protection temperature then press
Press OK until
is shown on screen
Programming is complete
Notes & Tips:
When the radiator is running in Auto the set temperature can be changed by
pressing +/At the next programmed mode change, the radiator will return to the
pre-set temperature
lt can be useful to write down the times and modes you want before starting to programme the radiator
The screen backlight switches of after 10 seconds and the radiator exits programme mode. If this happens you will need to press Prog / Config for 3 seconds and re-enter your modes.
Copyright Heattend Products Ltd 2018
13
Installation Notes:
14
ECODESIGN TABLE
Models Heat output
Avant Avant Avant Avant Avant Avant Avant Avant Avant DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ 350 500 750 1000 1250 1500 1800 950 L 1425 L
Nominal heat output (Pnom)
Maximum continuous heat output (Pmax,c)
0.35 0.5 0.75 1.0 1.25 1.5 kW kW kW kW kW kW
0.35 0.5 0.75 1.0 1.25 1.5 kW kW kW kW kW kW
Auxiliary electricity consumption
1.8 0.95 1.425 kW kW kW
1.8 0.95 1.425 kW kW kW
At nominal heat output (elmax) At minimum heat output (elmin)
In standby mode (elSB)
Type of heat output/room temperature control: Other control options:
0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
kW
kW
kW
kW
kW
kW
kW
kW
kW
0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
kW
kW
kW
kW
kW
kW
kW
kW
kW
0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
kW
kW
kW
kW
kW
kW
kW
kW
kW
Electronic room temperature control plus week timer
Room temperature control, with open window detection. With adaptive start
control. With distance control option.
Heattend Products Ltd, https://www.heattend.co.uk/ Email: enquiries@heattend.co.uk
15
MAINTENANCE AND CARE
Ducasa radiators require very little maintenance. The surfaces of the radiator
must not be cleaned with an abrasive product or those containing granular
substances. We recommend regular cleaning with PH neutral products. In order
to clean the radiator, it is recommended that the electric power is switched
off. To prevent a risk of overheating and to ensure optimum performance from
the radiator, the vents within the fins and control unit must be always kept
clear.
CORRECT DISPOSAL OF THIS PRODUCT
(Waste Electrical & Electronic Equipment) (Applicable in the European Union
and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should
not be disposed of with other household wastes at the end of its working life.
To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they
can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and
conditions of the purchase contract. This product should not be mixed with
other commercial wastes for disposal.
UK Distributor of Ducasa Products: Heattend Products Ltd
Web: www.heattend.co.uk Email: enquiries@heattend.co.uk
References
- Electric Heaters, Electric Heater, Electric Heating
- Electric Heaters, Electric Heater, Electric Heating
- Electric Heaters, Electric Heater, Electric Heating
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>