NeoRhythm B08B1WH9NC Gesture Controlled Headband User Manual
- June 3, 2024
- NeoRhythm
Table of Contents
- NeoRhythm B08B1WH9NC Gesture Controlled Headband
- Introduction
- Device Description
- Included in the Package
- Who CAN and CAN’T Use NeoRhythm
- Age Restrictions
- Possible Side Effects and General Precautions
- NeoRhythm Set-Up
- NeoRhythm’s Bluetooth® Settings (Stimulation status in the app)
- Controls
- Light Indicators
- Customization of the NeoRhythm band
- Band Positions
- Test Tube – How to Use and What Does It Tell You
- How to Use NeoRhythm Most Effectively
- Maintenance and Cleaning
- Troubleshooting Guide
- Technical and System Specification
- Classification
- Safety Warnings
- Manufacturer and Warranty Service
- DISCLAIMER
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NeoRhythm B08B1WH9NC Gesture Controlled Headband
Introduction
In a world full of options, we want to take a moment to say thank you for choosing us. Stimulation wearables using PEMF are an excellent tool for achieving the desired state of body and mind. Please take your time to read this user manual carefully, even if you are familiar with a similar product. To ensure your safety and that of others, please read this user manual before using NeoRhythm. Please do not disassemble the device. It can be unsafe and will void the manufacturer’s warranty.
This appliance should be used by adults over 18 years. Children over 8 years can also use it provided that they are under adult supervision. It can be used by people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning the use of the appliance in a safe manner and in addition to that understand the hazards involved. Children shall not play with the appliance. Children shall not clean or make any device maintenance without supervision. This appliance contains non-replaceable batteries. Must only be supplied with a safety extra-low voltage corresponding to the marking on the appliance. The appliance is only to be used with the power supply unit provided with the appliance.
WARNING: To recharge the battery, use only the detachable supply unit provided with this appliance.
Device Description
NeoRhythm is the first PEMF device with a multi-coil structure and gesture controls, which makes it one of the most user-friendly PEMF devices on the market. It helps you get into the desired state of mind by emitting scientifically supported frequencies through electromagnetic fields. The brain synchronizes with these frequencies to help you relax, enhance focus, energize body and mind, fall asleep quicker and sleep better, meditate better, or help living well with your pain. With appropriate positioning of the coils inside the device which generate electromagnetic fields, we precisely target the right locations to get the desired effect. NeoRhythm’s efficiency is confirmed by two independent double-blind, placebo-controlled studies and supported by many other scientific studies. To find out more, please visit https://omnipemf.com/how-it-works/.
Included in the Package
- NeoRhythm
- Charging dock
- Micro USB cable
- Adjustment kit
- User Manual
- Test tube
- NeoRhythm bag
- Hard reset tool
Who CAN and CAN’T Use NeoRhythm
CAN : NeoRhythm has been developed for the general public to safely and effectively energize your body. The expected key benefit of using NeoRhythm is better living. When PEMF is regularly and properly applied, the expected results are improved sleep quality, a facilitated reach of specific awake states, as well as improved emotional and logical intelligence.
CAN’T : The use of a pulsed electromagnetic field device is
contraindicated in people with pacemakers or other electronic implants, non-
MRI-safe IUDs, cochlear implants, or mechanical heart valves because the
magnetic field can shut the device off or otherwise interfere with its
functioning. You also shouldn’t use NeoRhythm if you have epilepsy.
Pulsed electromagnetic field is also contraindicated in organ transplant
patients due to a possible risk of affecting the immune suppression/rejection
process. There is a chance that electromagnetic fields may stimulate or
activate a more aggressive rejection process by stimulating the immune system.
The safety of pulsed electromagnetic fields has not been established in
pregnancy, although there is no evidence of harm. We advise against using
NeoRhythm during pregnancy.
Patients should consult their doctors when thinking about using a pulse
generator (NeoRhythm) with conventional medical treatment. This information is
not a substitute for professional medical advice.
Age Restrictions
NeoRhythm should only be used by individuals aged 18 years or older (“Permitted Age”). Children over 8 years can also use it provided that they are under adult supervision. If the user is of the Permitted Age but under the age of majority in the jurisdiction in which the user is domiciled, the user should review this manual and any applicable terms of use with their parent or guardian to make sure that the parent or guardian understands this manual and the applicable terms of use.
Possible Side Effects and General Precautions
NeoRhythm emits an electromagnetic field. There is no valid scientific reason to believe that NeoRhythm’s pulsed electromagnetic emission is harmful, but if you have concerns about exposure to these emissions, you should not use this device. Pulsed electromagnetic field side effects are usually non-existent or minor and temporary, but they may be observed in users who are hypersensitive to electromagnetic fields. It is very important to drink at least 8-10 oz (2-3 dl) of water before and after using NeoRhythm.
NeoRhythm Set-Up
- Make sure your band is fully charged.
- Search your app store for OmniPEMF or NeoRhythm. Download the app.
- Follow the in-app tutorial. It will guide you through connecting your band to your mobile device and completing your first NeoRhythm session. How to connect both devices using Bluetooth® is also described in Chapter 8, How to Pair NeoRhythm with Your Mobile Device.
- Join NeoRhythm’s social networks. They are a great place to learn more about the device and its features, share experience with other users, and chat with the team behind NeoRhythm.
NeoRhythm’s Bluetooth® Settings (Stimulation status in the app)
When NeoRhythm is activated, its Bluetooth® is automatically enabled and ready to connect with your device. However, the settings in the NeoRhythm app allow you to keep NeoRhythm’s Bluetooth® active while the stimulation process is on or to deactivate it WHILE the program is running, completely.
Bluetooth® during stimulation ON
This setting leaves Bluetooth® active also when you are using your NeoRhythm
(a stimulation program is running).
ADVANTAGES:
- A countdown timer progress bar will be activated while the stimulation program is running.
- You will have access to the in-app statistics on your mobile device (duration of stimulation program used, frequency of past usage, etc.) once the program ends and the Bluetooth® connection is reestablished (automatically).
- It’s easier to change stimulation programs, as your phone doesn’t need to reestablish its Bluetooth® connection to NeoRhythm. Simply select a new program and tap NeoRhythm twice or press the PLAY button in the app on your smartphone to start it.
DISADVANTAGES:
- If Bluetooth® is also active during stimulation, it emits its own (much higher) frequencies.
- Your mobile phone has to be within the Bluetooth® connectivity range of the band, or else due to connectivity loss, the data will not be synced.
Bluetooth® during stimulation OFF
This setting automatically deactivates NeoRhythm’s Bluetooth® when a
stimulation program starts and activates it again when the program ends.
Bluetooth® is completely disabled ONLY while the program is running.
ADVANTAGES:
- No unwanted additional frequencies emitted during stimulation, just the ones NeoRhythm emits to help you reach the desired state of mind.
- You don’t need your mobile device (only for setting up the program).
DISADVANTAGES:
- A countdown timer progress bar will not be activated while the stimulation program is running as the communication via Bluetooth® is not established.
- You will have access to the in-app statistics on your mobile device (duration of stimulation program used, frequency of past usage, etc.) only when you reconnect to the app via Bluetooth®. In this case, only the last 10 sessions run will be synced.
- Your mobile device needs to re-establish the connection to NeoRhythm every time you want to change the stimulation program. That means you will have to go to the home page and click CONNECT.
- Your mobile device won’t be able to communicate with NeoRhythm during the stimulation. Visiting the app on your smartphone, you will see the CONNECT button active, however, the connection will not be established because the program is running, and NeoRhythm’s Bluetooth® is OFF. You will have to stop (interrupt) the stimulation program with a double-tap and reconnect to the application on your smartphone.
Which setting is better for you?
The ON option is selected by default, and we suggest that you leave it this
way for the first few uses as it doesn’t require to re-establish the
connection each time you want to select a new stimulation program. You can
turn it off later if you don’t want the Bluetooth® to be active when you use
your NeoRhyhtm.
NOTE: If you are using the same stimulation program most of the time, it is recommended that you turn Bluetooth® off in the app’s settings. This will allow you to use your NeoRhythm only with the gesture controls – simply tap it twice (after waking it up) to restart your most recently used program.
How will I know that my chosen stimulation program has started/stopped if I
turn off Bluetooth®?
Although you won’t be able to see the progress bar, NeoRhythm will notify you
when your chosen program starts/stops with vibrations and light indicators.
Controls
NeoRhythm is gesture-controlled. No buttons. No cables. Bluetooth® is also not required, except for when you are changing or choosing a new program. This makes NeoRhythm one of the most user-friendly devices on the market. Neorhythm can be controlled by pressing the PLAY/STOP button in the app on your smartphone or by tapping the device with your hand. For regular use of the same program, you don’t need your smartphone. A smartphone is only needed for switching among different stimulation programs or changing the settings.
USING NEORHYTHM FOR THE FIRST TIME
-
CHARGE
Charge your NeoRhythm for a minimum of 2.5 hours when using it for the first time. NeoRhythm is unlocked when plugged into the charger. -
DOWNLOAD THE APP
Download the OmniPEMF App to your mobile device or tablet from the iOS App Store or Google Play store. -
START THE APP
Press START and accept the Terms and Conditions. Make sure to have Bluetooth on your device turned ON and follow the step-by-step User Guide. If you are using an Android device, you will be asked to enable location services while using the app. -
WAKE UP THE DEVICE
Double tap the device to wake it up (confirmed by a double vibration) – at this point the device is ready to use. -
CONNECT
Click the CONNECT button in the app and wait until NeoRhythm pairs with your device. -
CHOOSE YOUR MODE
Choose between QUICK START or ADVANCED MODE. -
START SESSION
Once you choose a program, set your duration and the session will begin (followed by single vibration). To stop a session either press the STOP button in the app or double tap the device.
How to turn it off?
Tap NeoRhythm twice to stop the current program or press the STOP button in
the app. It will turn off by itself in a few minutes.
How to check if stimulation is in progress?
Check if the green light is blinking (1 blink per second). Each stimulation
program also starts with 1 short vibration. You can also use the test tube
with a magnet to confirm the presence of a magnetic field.
How to check if NeoRhythm is charging?
Orange light means it’s charging. No light while charging means it’s fully
charged. Blinking red light (1 blink per second) means the battery is low.
How do I know NeoRhythm is connected to my phone?
Blinking orange light (1 blink per second) means it’s connected to your mobile
device (and no program is running).
How to change a program?
To change a program currently running just double tap the device (followed by
double vibration) or press the STOP button in the app. Go back into the main
menu and choose a desired program.
How to restart the same program?
To restart the last used program, pick up NeoRhythm and double tap it
(followed by a single vibration) – the last used program will restart itself.
You do not need to use the app to run the same program repeatedly.
How and when to use the hard reset tool?
If you encounter a problem and NeoRhythm stops functioning, you can use the
hard reset feature (number 3).
When should you use hard reset?
- No response when charging the device,
- Wrong LED light color when charging/done charging/starting a new program (check the light signals described in the next chapter),
Always check if the battery is full. When resetting the device, insert the
hard reset tool into the hole close to the micro USB port and push gently.
To keep you updated on the current state of the device, NeoRhythm has
integrated 3 different color light indicators – orange, red, and green LED
lights. Read more about them in the next chapter.
How and when to use the “LOCK NEORHYTHM” function in the app?
If you want to turn NeoRhythm off completely, connect to the device via
Bluetooth®, go under settings, and click LOCK NEORHYTHM. This will completely
shut it down and lock it to prevent further use. To start using it again, plug
it into a USB port to unlock it. All the statistics will be stored on the
phone.
When to use this function?
You can lock your NeoRhythm when traveling or carrying it in a
bag/purse/backpack for more extended periods to prevent unintentional use.
Light Indicators
NeoRhythm has a LED light on its left side that indicates what state it’s in. The light can be green, orange or red.
- Blinking red light : The battery is low and you have to recharge the device.
- Blinking orange light (1 blink per second): NeoRhythm is connected to your phone via Bluetooth®.
- Orange light on : NeoRhythm is charging, USB is plugged in.
- No light on when charging : NeoRhythm is fully charged.
- Blinking green light (1 blink per second): The chosen stimulation program is running.
- Slowly blinking green light (1 blink per 5 seconds) : NeoRhythm is on standby and ready to connect.
Customization of the NeoRhythm band
NeoRhythm is designed to fit most users. The band should be suitable for at
least 90% of people with different head sizes and shapes. Individual
characteristics will sometimes require customization of the band. In this
case, you can use the included Adjustment kit to make sure NeoRhythm fits your
head perfectly.
We advise you to first try NeoRhythm as it is. If it fits your head, no
further action is required. If it feels loose and it feels like it’s going to
slide off your head, use the included extra pads to make it fit comfortably.
The default side and front pads are 1.6 mm (0.063 in) thick. The Adjustment
Kit includes extra pads that are 3 mm (0.118 in) and 6 mm (0.236 in) thick.
How to Select the Right Pads
Before sticking the self-adhesive surface of the pads onto NeoRhythm, we
recommend that you just place the pads on the appropriate spot and try wearing
the band to find out which thickness of pads works best for you. After that,
you can either remove the default pads and stick the chosen extra pads onto
their place, or simply stick the chosen extra pads onto the default pads.
How to Stick the Extra Pads for a Perfect Fit
- Remove the protective foil on the pad to expose its self-adhesive surface.
- Align the edges of the pad with the edges of the corresponding area on the band and stick just the edges first.
- Press the middle of the pad down to the surface of the band to stick the remainder of the pad. Failing to stick the edges first as described may result in pads not being aligned with the surface of the band.
Failing to stick the edges first as described may result in pads not being aligned with the surface of the band.
NeoRhythm Adjustment Kit includes:
- 6 x Big Pads (114 x 19,6 mm) in 3 different thicknesses (1.5 mm, 3 mm, 6 mm)
- 1 x Medium Pad (36.5 x 23.5 mm) in 1 thicknesses (3 mm)
Warning : Contains small parts that pose a choking hazard. Keep away from young children.
Band Positions
NeoRhythm has five specially designed coils that generate electromagnetic fields and are powered by a pulse generator also located in the band. The ability to adapt stimulation zones to the chosen program is a unique advantage of NeoRhythm. This benefit enables it to target the right part of the body more efficiently. That is why we wear NeoRhythm in different positions on the body depending on the chosen stimulation program.
Note : The positions shown below can be slightly adjusted to better fit your individual needs and make wearing NeoRhythm comfortable in any situation. Changing the band’s position for up to about an inch (3-4 cm) won’t decrease its effectiveness or interfere with its functioning in any significant way.
Note : Proper band positioning is also shown within each stimulation program in the NeoRhythm app.
INFLUENCED AREAS
Where to use: For more information please see https://omnipemf.com/support/
Test Tube – How to Use and What Does It Tell You
In most cases, the non-invasive pulses are not tangible. Because of that reason, we added a magnetic tester tube in the NeoRhtyhm package with which you can hear the impulses emitted by the band. It can be used to confirm that a stimulation program is running (NeoRhythm emits an electromagnetic field when active and the magnet reacts to it – you can hear a sound when listening to the test tube). You can also test the frequency of pulsed electromagnetic fields in different stimulation programs, as well as observe the change in the strength of the electromagnetic field as the test tube moves away from or closer to NeoRhythm.
What do you actually hear when using the tube?
As the magnet in the tube reacts to the magnetic field produced, you get to
hear the frequency of the electromagnetic pulses emitted by the coils inside
NeoRhythm.
Testing the FREQUENCY of different stimulation programs
Choose the desired program in the application, run it and place the test tube
on NeoRhythm. The test tube must touch the device. Place the glassy bottom of
the tube on the device and place your ear on the other side where the silver
cap is. Testing is done on both the ends of the band and in the middle of it.
That is where the coils are placed and the impulses can be heard. If you, for
example, choose the Improve Sleep program, you will be able to hear a low
frequency, because this program uses low frequencies of theta brainwaves to
calm your brain and prepare it for sleep. It will sound like a slow beating
(with 3-4 beats per second). Then try the Improve Focus Capacity program.
Select it in the application, run it, and move the test tube close to
NeoRhythm. The sound frequency will be much higher because the Improve Focus
Capacity program uses beta brainwave frequencies to sharpen your brain and
prepare it for intensely focused work. This program produces a fast-beating
noise (with 30+ beats per second).
Contact us through our social media (FB) accounts or by email about using
NeoRhythm. It is possible that the band has been placed incorrectly. There are
several positions how you can use NeoRhythm. In many cases, simply adjusting
the band placement greatly improves the effectiveness of the device.
It is also possible that the period of use has not been long enough for the
desired effect to be seen. Consider using NeoRhythm regularly for 2 to 3
weeks. Beneficial effects are usually seen within the first few days.
NeoRhythm seems to help, but then the problem eventually comes back.
If a short period of using NeoRhythm yielded good results, but then after not
using NeoRhythm for a while, the problem recurs, consider using NeoRhythm for
a more extended period. Proper nutritional support and supplements are also
helpful in conjunction with using NeoRhythm.
How to Use NeoRhythm Most Effectively
Recommendations
- For general wellness, it is recommended that you use your NeoRhythm twice a day. That helps recharge your cells to their optimal state. Check the in-app instructions found inside each stimulation program to learn what is the recommended usage frequency and the duration of stimulation.
- It is recommended to drink enough water (at least 8-10 8-ounce cups or 2 liters a day) and at least one 8-ounce (2 dl) cup of water before using NeoRhythm and immediately after as to help facilitate the natural release of toxins.
- Eat a healthy diet, free of chemicals and pesticides, refined foods and sugar, and consume a lot of green vegetables.
Maintenance and Cleaning
Do not use NeoRhythm near water and when you are wet. NeoRhythm is not water-
resistant but may be wiped down with a damp cloth for cleaning.
Avoid excessive physical impact to the device, and do not stretch or bend it
as this can damage the copper coils and the hardware. The manufacturer does
not take responsibility for devices damaged by improper use.
Troubleshooting Guide
It is important to know that we are always here for you. If you have any questions, please contact us through our social media (Omnipemf Community on Facebook) or by email (foryou@omnipemf.com) also found on our website.
The LED indicator is not working.
Recharge the battery. Check the USB cable.
The device has been exposed to excessive amounts of water.
NeoRhythm is not designed to be waterproof, although short exposure to water
may not permanently damage the device. If NeoRhythm has been exposed to water,
recovery may be possible by placing the unit in a sealed bag or a container
with dry uncooked rice for 2 to 3 days. The rice will act as a desiccant and
slowly remove the moisture.
NeoRhythm fails to help the problem for which it was purchased.
First, verify that NeoRhythm is functioning. Make sure that the battery is
fully functional for the whole duration of stimulation each time it is used.
Make sure the LED lights are functioning and that the green light is blinking.
Make sure that the start of the program is confirmed by 1 short vibration.
Contact us through our social media (FB) accounts or by email about using
NeoRhythm. It is possible that the band has been placed incorrectly. There are
several positions how you can use NeoRhythm. In many cases, simply adjusting
the band placement greatly improves the effectiveness of the device.
It is also possible that the period of use has not been long enough for the
desired effect to be seen. Consider using NeoRhythm regularly for 2 to 3
weeks. Beneficial effects are usually seen within the first few days.
NeoRhythm seems to help, but then the problem eventually comes back.
If a short period of using NeoRhythm yielded good results, but then after not
using NeoRhythm for a while, the problem recurs, consider using NeoRhythm for
a more extended period. Proper nutritional support and supplements are also
helpful in conjunction with using NeoRhythm.
Technical and System Specification
Operating system| Android 5.0 and above iOS
7 and above
---|---
Waveform| Trapezoidal
Frequency Range| 1 – 303.41 Hz
Maximum Magnetic Field Intensity| 25 gauss (2.5 mT)
Number of Programs| 12 + custom programs
Program Duration| 30 min – 8 hours; selected minutes or
continuous
Power| Internal rechargeable battery
Weight| 105 g
Dimensions| 160 mm (6.3 in) x 170 mm (6.7 in)
x 28 mm (1.1 in)
Warranty| 2 years
Classification
NeoRhythm is classified as a household device.
CE regulatory information:
- Safety : EN 60335-1
- EMC EN 303 4461 (EN 55014-1/2)
- Radio Equipment Directive (RED) 2014/53/EU
FCC regulatory information:
device complies with part 15 of the FCC Rules
Safety Warnings
- Do not expose NeoRhythm to fire, place it near a hot oven, or mechanically crush or cut the device or its battery, as this may result in an explosion.
- Do not expose NeoRhythm to extremely high temperatures, as this may result in an explosion or leakage of flammable liquid or gas.
- Do not expose NeoRhythm to extremely low air pressure, as this may result in an explosion or leakage of flammable liquid or gas.
- Don’t attempt to replace NeoRhythm’s battery yourself – you may damage the battery, which could cause overheating and/or injuries
Manufacturer and Warranty Service
MANUFACTURER MDCN TECH Ltd Made in Europe WARRANTY SERVICE
Contact
Email: foryou@omnipemf.com
Our warranty policy covers physical and digital defects. All devices purchased through omnipemf.com or any other official sale channels of MDCN Tech Ltd are covered by this warranty. If a device exhibits physical or digital defects that affect its functioning and this is verified by our customer support team, then a replacement or direct compensation is in line with this Warranty Policy. The Warranty Policy is active for two (2) years after the device is received by the customer, with a maximum extension of twenty-six (26) months. If a defect is verified and replacement approved, anew replacement product will be sent to the customer using the address and shipping instructions of their original order, unless requested otherwise. We offer no replacements or refunds for any products designated on this site as nonreturnable. The warranty is not applicable in the following cases:
- Failure or damage to the device or its components due to improper use.
- Damage and contamination of the device caused by improper protection.
- If the device’s hardware or software has been opened, accessed and/or modified from its original functioning state.
DISCLAIMER
MDCN TECH LTD and its distributors offer low risk, general wellness products that promote a healthy lifestyle, help to maintain or encourage good health, or reduce the impact or risk of some chronic diseases and conditions where a healthy lifestyle has been shown to play an essential role in improving quality of life and living well. These statements have not been evaluated by the FDA and products are not intended to diagnose, treat, cure, or prevent any disease or medical condition. PEMF products are meant to address energetic elements that aid the body’s natural healing abilities and help restore and maintain energetic balance. The therapeutic low- and medium-intensity pulsed electromagnetic fields generated by these products use similar levels of energy as the natural vitalizing energy of the Earth. The use of a PEMF product is contraindicated in people with pacemakers or other electronic implants, cochlear implants, or mechanical heart valves.
PEMF products are also contraindicated during pregnancy and in people with epilepsy or bleeding. PEMF therapy is also contraindicated for: organ transplant recipients orthose on immunosuppressive therapy and those with non- MRI-safe IUDs. Patients should tell their physicians when they are thinking about using NeoRhythm* with conventional medical treatment. This information is not a substitute for professional medical advice. If you have or suspect a medical problem, please consult your healthcare provider. Content generated or found through MDCN TECH LTD services or products is for informational purposes only and is not intended to replace the relationship between you and your physician or other healthcare providers. MDCN TECH LTD is not a licensed medical or healthcare provider and has no expertise in diagnosing, examining, or treating medical conditions of any kind.
References
- Omnipemf | Optimize your health with PEMF technology
- Omnipemf | Optimize your health with PEMF technology
- PEMF Science | Why Our Product Works | Omnipemf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>