NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set Instruction Manual

June 3, 2024
NATIONAL GEOGRAPHIC

NATIONAL GEOGRAPHIC-logo

NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set

NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set-fig1

WARNING! Not for children under three years. Choking hazard – small parts. Contains functional sharp edges and points!
ATTENTION: Only suitable for children of at least 8 years of age. Instructions for parents or other responsible persons are enclosed and must be followed. Keep packaging as it contains important information.

General Information

About This instruction Manual
Please read the safety instructions in this manual carefully. To avoid damage to the unit and the risk of injury, only use this product as described in the manual. Keep the instruction manual handy so that you can easily look up information on all the func-tions.

Intended Use

  • This product is intended only for private use.
  • It was developed for magnified viewing of natural and man-made objects.

General Warnings

  • Choking hazard — This product contains small parts that could be swallowed by children. This poses a choking hazard.

  • Risk of electric shock — This device contains electronic components that operate via a power source (batteries). Only use the device as described in the manual, otherwise you run the risk of an electric shock.

  • Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion.

  • Risk of chemical burn — Make sure you insert the batteries correctly. Empty or damaged batteries could cause burns if they come into contact with the skin. If necessary, wear adequate gloves for protection.

  • Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately with a plenty of water and seek medical attention.

  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands, types or with different capacities. Remove the batteries from the unit if it is not to be used for a long period of time, or if the batteries are empty!

  • Never recharge normal, non-rechargeable batteries. This could lead to explosion during the charging process.

  • Rechargeable batteries are only to be charged under adult supervision.

  • Rechargeable batteries are to be removed from the toy before being charged

  • The terminals must not be short-circuited.

  • Do not disassemble the device. In the event of a defect, please contact your dealer.
    The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.

  •  Tools with sharp edges are often used when working with this device. Because there is a risk of injury from such tools, store this device and all tools and accessories in a location that is out of the reach of children.

  • Keep instructions and packaging as they contain important information.

Parts overview

NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set-fig2

  1. 10X WF eyepiece
  2. 16X WF eyepiece
  3. Barlow lens
  4. Electronic eyepiece (MicrOcular)
  5. Microscope head
  6. Objective revolver
  7. Microscope stage
  8. Focus wheel
  9. LED lighting (transmitted light)
  10. Electricity supply
  11. Microscope base
  12. Main plug
  13. 5 slides, 10 covering glasses and 5 preparations in a plastic box
  14. Colour filter disc
  15.  LED lighting (reflected light)
  16. Direct light/transmitted light switch
  17. Microscope tools: a) pipette; b) tweezers
  18. Hatchery
  19. MicroCut
  20.  Specimens:
    • a) yeast;
    • b) gum media (specimen inclusion medium);
    • c) sea salt;
    • d) brine shrimp eggs
  21. Locking screw

General/Location

  • Make sure you position your microscope on a stable, solid surface. An electricity sup-ply is required for observation with the electric illuminator.
  • Position your device so that it can be disconnected from the power supply at any time. The wall you use socket should be located near the device and easily accessible, since the plug on the power cord serves as a disconnecting device for the power supply. Always pull on the plug to separate the device from the power supply. Never pull on the cord.

Electric LED lighting

  • Before use, make sure the light switch (16) is set to ‘off’.
  • The microscope has two light sources. Lighting can be of three types. Set the switch (16) to ‘II’ to light the specimen from above (reflected light) or ‘I’ to light it from below (transmitted light). Use setting ‘III’ to light the specimen simultaneously by transmitted and reflected light. The transmitted light unit (9) is used for transparent specimens (those on glass slides). To view solid, non-transparent specimens, use the reflected light unit (15). Use of both forms of lighting simultaneously is only recommended for semitransparent specimens. This operating mode is not recommended for transmitted light specimens on slides as it may cause reflection on the slide.

Colour filter disc

The colour filter (14) under the microscope table (7) aids in viewing very bright and transparent objects. Just select the right colour for the specimen in question. The components of colourless or transparent objects (e.g. starch particles, single-cell specimens) can thus be better recognised.

Microscope setup

  • The microscope head (5) will now be prepared for your first observation. First, loosen the screw (21) and rotate the head into a convenient position. Begin every observation with the lowest magnification. Place the microscope’s table (7) with the focus knob (8) into the lowest position and rotate the objective revolver (6) until it locks on the lowest magnification (4X).
    NOTE:
    Make sure to place the microscope’s table (7) in its lowest position before changing the objective in order to prevent damage to the microscope.

  • Insert the 10X eyepiece (No. 1, 1) in the Barlow lens (No. 1, 3).
    Take care that the Barlow lens is inserted completely into the monocular head (No. 1, 4).

Observation

After you have set up the microscope with the proper illumination, the following prin-ciples are important:

  • Begin each observation at the lowest magnification, so that the centre and position of the object to be viewed is in focus. The higher the magnification, the more light is required for good picture quality.

  • Place a permanent slide culture directly under the microscope lens on the plate (7). The specimen to be examined must be directly over the lighting.

  • Look through the eyepiece (1 and 2) and carefully turn the focus wheel (8) until you can see a sharp picture.

  • Now you can progress to a higher magnification. Slowly pull the Barlow lens (No. 2, 3) out of the monocular barrel (No. 2, 4). When the Barlow lens is nearly entirely pulled out, the magnification is raised to 2X.

  • For even higher magnification, you can put the 16X eyepiece (2) into the objective revolver (6) and rotate the objective revolver to a higher magnification (10X or 40X).
    TIP:
    Depending on the preparation, higher magnifications do not always lead to better pictures.

  • When changing the magnification of your microscope by changing or adjusting the eyepiece, objective lens or Barlow lens, you must readjust the focus wheel (8) to sharpen the image.
    NOTE:
    Please be very careful when doing this. If you move the mechanical plate upward too fast, the objective lens and the slide can touch and become damaged.

Experiments

Use the following web link to find interesting experiments you can try out. http://www.bresser.de/downloads

  • How do I install the MicrOcular?
    Note:

    • The MicrOcular only works without the included Barlow lens! The magnification setting is changed when the MicrOcular is used, and it must be readjusted with the focus knob.

NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set-fig5
NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set-fig6
NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set-fig8

  * First, remove the Barlow lens (Fig. 5, 3) with the current eyepiece from the eyepiece support (Fig. 5, 5) and place the MicrOcular (Fig. 6, 4) in the eyepiece (Fig. 6, 5).
  • How do I install the software?
1. You can download the setup file for installation here: [www.bresser.de/download/CamLabLite](http://www.bresser.de/download/CamLabLite)
2. Start the installation with a double click on the .exe file and follow the instructions of the installation manager.
3. It is not necessary to install a special driver. The camera is automatically recognized by your Windows operating system.

Using the MicrOcular

Preparation

  1. Slide a specimen under your microscope and focus on it.
  2. Remove the eyepiece and Barlow lens from the eyepiece support and the dust cap from your MikrOkular and then install the MikrOkular into the eyepiece support in-stead of the Barlow lens.
  3. Start your PC if you haven‘t yet and connect your MikrOkular to the USB port of your computer.
  4. Start the „CamLabLite“ software and activate the camera by clicking on „USB Video Device.
  5. Click on „Snapshot“ to take a picture or on „Capture“ to record a video.
  6. Click on the floppy disk icon to save the image or capture.

Care and maintenance

  • Before cleaning, separate the device from the power supply by removing the plug. Only use a dry cloth to clean the exterior of the device.
    NOTE:
    Do not use any cleaning fluid to avoid damaging the electronics.

  • Clean the lenses eyepieces and lenses only with a soft, lint-free cloth, like a microfibre cloth.
    NOTE:
    Do not apply excess pressure to the cloth so as to avoid scratching the lenses.

  • To remove more stubborn dirt, moisten the cleaning cloth with an eyeglass-cleaning solution and wipe the lenses gently. Protect the device from dust and moisture. After use, particularly in high humidity, let the device acclimatize for a short period of time, so that the residual moisture can dissipate before storing.

Troubleshooting

Error Solution
No recognizable image •  Turn on light

•  Readjust focus

•  Check Windows privacy settings

Image flickers (while observing with MicrOcular) = Monitor refresh rate not adequate| •  If necessary, increase resolution of graphics card

• Adjust brightness at the dimmer of the microscope

•  Disable automatic exposure

Magnification table

NATIONAL GEOGRAPHIC 40X-1024X USB Microscope Set-fig9

DISPOSAL

  • Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.
  • Do not dispose of electronic devices in the household garbage!
  • As per Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.
  • In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive.
    1. battery contains cadmium
    2. battery contains mercury
    3. battery contains lead

EC Declaration of Conformity

Bresser GmbH has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/download/9039100/CE/9039100_CE.pdf

UKCA Declaration of Conformity

Bresser GmbH has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address: www.bresser.de/download/9039100/UKCA/9039100_UKCA.pdf Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6Hf, Great Britain

Warranty & Service

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms and details of our services at: www.bresser.de/warranty_terms.

ABOUT COMPANY

  • Bresser GmbH
  • Bresser UK Ltd.
    • Suite 3G, Eden House
    • Enterprise Way, Edenbridge,
    • Kent TN8 6Hf, Great Britain
  • National Geographic Partners LLC. All rights reserved.
  • NATIONAL GEOGRAPHIC and Yellow Border Design are trademarks of National Geographic Society, used under license.
  • Visit our website: www.nationalgeographic.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NATIONAL GEOGRAPHIC User Manuals

Related Manuals