IKA-HAGEN Cooker Hood
Structure
Installation
The manufacturer will not be held liable for any damages resulting from
incorrect or improper installation.
Please read this instruction manual before installing and using this cooker
hood.
Properly keep this instruction manual in a safe place for future reference.
- This cooker hood can be only used in the Ducted Mode (ducting fumes to the outside)
- Only a qualified and trained service technician can undertake the work of installation and services.
- Check that the mains voltage corresponds to the one indicated on the rating plate fixed inside the hood.
- Check that the domestic power supply guarantees adequate earthing.
- Do not connect the hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.)
- If the hood is used in conjunction with non-electrical appliances (e. g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening directly with the open air in order to guarantee the entry of clean air.
- The minimum distance is 750mm from the cooker hood to a gas hob, and is 650mm to an electric hob. If the installation instructions for gas hobs specify a greater distance, this must be taken into account.
Note
- On stainless steel hoods, carefully remove the plastic protective film from all exterior surfaces of the hood and chimney prior to final installation.
- At least two people will be required to mount the hood.
WALL DRILLING AND BRACKETS FIXING
- Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.
- Draw a horizontal line at the dimension of picture shown,
- Place chimney mounting brackets on the wall as shown about 20mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
- Mark the wall at the centre of the holes in the bracket.
- Place the hood mounting bracket on the wall as shown aligning the central notches to the vertical reference line.
- Mark the wall at the centre of the holes in the bracket.
- Drill 1Omm holes at all the centre points marked.
- Fix the two brackets using the mounting screws and drywall anchors.
- Fix the fasten screw to hood mounting bracket.
MOUNTING THE HOOD
- Hook the body onto the hood mounting bracket 8 as shown.
- Balance the hood body by slightly adjusting the hood mounting bracket.
Gently lower the hood until it securely engages the bracket.
DUCT FIXING
Caution: To reduce the risk of fire, use metal ductwork only.
- Attach an adequate length of 9170mm round duct into the recessed area of the air outlet adapter.
- Secure the duct using two screws that have been already fixed on the two sides of the air outlet adapter. Make sure the duct is fixed well on.
CONNECTIONS
Ducted mode air exhaust system
Caution: To reduce the risk of fire, use metal ductwork only.
- Decide where the ductwork will run between the hood and the outside.
- A straight, short duct run will allow the hood to perform most efficiently.
- Long duct runs, elbows, and transitions will reduce the suction performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs.
- Attach an adequate length of p170mm round duct to the air outlet adapter
- The air must not be discharge into a flue t that is used for exhausting fumes from appliances such as burning gas or other fuels. Regulations concerning the discharge of air have to be fulfilled.
- Install a roof/wall cap. Connect round metal ductwork to cap and work back towards hood location. Use duct tape to seal the joints between ductwork sections.
Electrical connection
Electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards. Turn off electrical power at service entrance
before wiring.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard
Do not use the plug and an extension cord other than the ones initially
supplied with the hood.
The earthing of this hood is compulsory. Do not remove ground prong of the
plug.
TELESCOPIC CHIMNEY COMPRISING ASSEMBLY
Decorative Chimney Bottom
- Carefully slide the decorative chimney bottom 1.1 down •-outside the decorative chimney top 1.2. Carefully place the decorative chimney bottom 1.1 into the recessed area of the hood body top.
- Fix the Decorative Chimney Bottom 1.1 with the four decorative Chimney Bottom screws 8 supplied backwards.
Decorative Chimney Top
- Raise the decorative chimney top 1 .2 up inside the decorative chimney bottom 1.1 1.2 Secure the decorative chimney top 1.1 to the chimney mounting bracket 7 that is well fixed
on the wall with the two chimney bracket screws 8 supplied from two sides.
Insturtion of operation
Clock setting
When hood is off, press could start to set the clock. First setting is hours,
press again is mins, the third press is confirm. When you setting the clock,
is up and is down.
Time delay function
When fan speed or illumination is working. press and the hood will be off
after 1 min. You could keep pressing to choose 1mins/3mins/5mins and cancel.
When time comes up the hood will be close.
Stir-fry function
When hood is on, press to use stri-fry function for 3mins. Press again for
stop it and back to normal fan speed.
Hand wave sense function
When the hood is turn off, wave hand left to right front of hood (as pic (1)
shows), turn on the hood and lamp.
When the hood is working, wave hand right to left (as pic(2) shows), turn off
the hood and lamp.
When the hood is working, wave hand left to right front of hood (as pic (1)
shows), will switch to mid fan speed-high fan speed-stri-frylow fan speedmid
fan speed..
When the hood in delay function, wave hand left to right front of hood (as pic
(1) shows) to turn off delay function
When the hood turn off, touch and in the same time could control Hand Wave
sense function. If the “1” icon lights up means turn on; If the icon lights
down means turn off.
Lock function
In case the hood will turn on when the user cleaning the hood, we have lock
function.
Press for 3s, the icon will be flicker, means lock function is turn on.
Press for 3s again or after half hour the Iock function will be turn off.
Wiring diagram
Clean function
Warning:
- Please turn off the fan before use the clean function.
- Do not put any detergent in the water, it will corrode the inside of hood.
- Please make sure you have place the water tank right.
- After the cleaning please clean up the water tank also.
- Please do not put any food under the hood and turn off the hob when you using clean function.
- The water can not over 40C.
Maintenance
Hood Cleaning
Cleaning tips:
- Hot water with soap or detergent is all that is usually needed.
- Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
- For discolorations or deposits that persist, use a non-scratching household cleanser with a little water and a soft cloth.
- For stubborn stain, use a plastic scouring pad or soft bristle brush together with cleanser and water. Rub lightly in direction of polishing lines or grain” of the stainless finish. Avoid using to0o much pressure that may mar the surface.
- Do not allow residue of detergent to remain for long periods of time.
- Do not use ordinary steel wool or steel brushes, it may cause scratches to the glass surface.
- Do not allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals that may be harmful.
- Rinse with water after exposure and wipe dry with a clean cloth.
- Painted surfaces should be cleaned with warm water and mild detergent only.
Maintenance
- Proper maintenance of the cooker hood will assure proper performance of the unit.
- Disconnect the hood from the main supply before carrying out any maintenance work.
- Clean and/or replace aluminum grease filters or charcoal filters after specified period of time.
- Clean the hood using a damp cloth and a neutral liquid detergent.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
WARNING!!
In certain circumstances electrical appliances may be a danger hazard.
- Do not check the status of the filters while the cooker hood is operating.
- Do not touch the light bulbs after appliance use.
- Do not disconnect the appliance with wet hands.
- Avoid naked flame, as it is damaging to the filters and can cause a fire hazard.
- Constantly check the food while frying to prevent oil from overheated as it may lead to a fire hazard.
- Disconnect the electrical plug prior to any maintenance.
- Children will not recognize the risks of electrical appliances. Therefore use or keep the appliance only under supervision of adults and out of reach from children.