RM ITALY BLA350 PLUS Solid State Compact HF 300W Linear Amplifier User Manual
- June 3, 2024
- RM ITALY
Table of Contents
RM ITALY BLA350 PLUS Solid State Compact HF 300W Linear Amplifier User
Manual
Introduction
The RM Italy BLA350 Plus is a fully automatic compact 300W HF linear Amplifier, that builds on the success of the previous model. It now features a hardware protection circuit for output impedance mismatch that is lightning fast ensuring the safety of the power transistors in the event of high VSWR on the antenna connector. The RF deck has been improved as have the output band filters. Frequency coverage is from 1.8MHz to 30MHz covering the following bands, 160, 80, 40, 30, 20, 17, 15, 12 and 10m Amateur radio bands. It utilises two 50V MACOM MRF 150 MOSFET Transistors in Push Pull configuration, (Class AB). It may be used on all narrow band modes of transmission e.g. SSB,AM,FM, CW, RTTY, FT8 etc. It features a dual MCU controlled variable speed cooling system, a large analogue output power meter and a 2 line 16 character LCD display that displays the amplifiers operating parameters, such as frequency, filter selection, temperature and allows quick navigation of the amplifiers menu system. Attention to correct operation and operating the amplifier within its operating capabilities will ensure optimum performance and many years of trouble free use.
Specifications
Operating Frequency: 160,80,40,30,20,17,15,12,10m Amateur radio bands 60m band
with reduced harmonic attenuation No Tx <1.5MHz & >30MHz
Operating Modes: SSB,CW,AM,FM,RTTY,Data All narrow band modes
Input Power: 1-12W max
Output Power: 300W max
Harmonic Output: >-50dBc
Drain Voltage: 48Vdc
Drain Current: 15A max
Input Impedance: 50 Ω unbalanced
Output Impedance: 50 Ω unbalanced
RF Transistor: MACOM MRF150 Matched Pair
Amplifier configuration: Class AB Push-Pull
Cooling: Temperature regulated forced air cooling
Microprocessor: Microchip PIC 18F4620
Metering: Output Power, H/S Temperature, Band in use, Amplifier state
Protection: Input Power, Filter Error, VSWR, Temperature, Frequency
I/P—O/P Connections: UHF SO-239 (Low loss Teflon insulator), PTT input – RCA /
Phono, ALC output – RCA / Phono.
AC Power: 207-244Vac 3.5A max
Dimensions: 355 x 155 x 270mm (Width x Height x Depth)
Weight: 13.5kg
Supplied Accessories: AC Power cord
NON RESONANT ANTENNA TUNING WARNING!!!!
When using the BLA350 Plus amplifier together with a non resonant antenna and either a manual or automatic antenna tuner it is very important the following precautions are taken.
The correct sequence for connection would be Transceiver, BLA350 Plus Amplifier, VSWR/ Power meter, ATU and Antenna
If using a transceiver with a built in ATU this function should be disabled if possible or operated in through mode as the input to the BLA350 amplifier is 50 Ohms. The internal ATU can no longer tune the antenna.
Tuning of a non resonant antenna should always and only be performed at low power. Most antenna tuners have a particular power rating and usually this maximum power rating is quoted under tuned conditions. With the amplifier connected in line this should be done with the amplifier either off or in stand by mode. Once an acceptable match has been provided equal to 1.5:1 or better the amplifier may then be operated and the tuner may then be adjusted slightly to optimise the match. If this method is not followed and the antenna is tuned with the amplifier running at full output the high impedances possible during the tuning process can cause damage to the amplifiers output transistors and should be avoided at all costs. Failure to follow this procedure may well result in damage to the amplifier that is not covered by the warranty
Quick Start Guide
- Connect the RTX input connector (\) to the transceiver with a 50 ohm patch cable.
- Connect the ANT output connector ([) of the BLA350 Plus to VSWR/Power meter and ATU if required or directly to the antenna if resonant at the operating frequency desired.
- Connect the PTT output cable from the transceiver to the PTT input (_) of the BLA350 plus. (BLA350 Plus PTT input is Active Low).
- Make sure the ON / OFF switch (a) is set to OFF, Switch (_) MAN (Manual) / AUT (Automatic) is set to ‘AUT’ and that switch (\) Stby (Standby) / AUT (Automatic) is set to Stby.
- Connect the AC power cord to the amplifier (`) and household AC outlet .
- Make sure that the amplifier is OFF (a) or in Standby mode (\).
- Adjust the transceivers output to 10W, if capable of more than 10W output.
- Test that the antenna connected is correct or tuned for the current frequency selected. If necessary match the antenna to the desired frequency with the ATU. This must be done with the amplifier switched off or in standby mode.
- Switch the Stby / ON switch (\) to ON.
- Now when the PTT on the transceiver is pressed the amplifier will switch to TX, indicated by the front panel LED (d) and an indication of the output power (b).
Front / Rear Panel Description
Front Panel
- LCD Display – displays amplifiers operating parameters and menu system
- Standby / On – In standby the amplifier does not amplify the incoming signal. Menu adjustments can be made in this mode
- OK /SSB – Menu setting conformation and SSB RTX delay ’on’ / ’OFF’, if the amplifier is used in VOX mode
- SET – Menu Switch
- AUT / MAN – Auto or manual band filter mode
- BAND – Manual band filter selector
- MAIN – primary AC ’ON’ / ‘OFF’ switch
- Output Power Meter
- ON – Amplifier active LED
- TX – Amplifier in Transmission LED
- Warning – Alarm LED. Illuminates when there is an alarm condition, excessive temperature / antenna SWR etc.
- MAN – When manual filter selection is selected this LED will illuminate
Rear Panel
- ANT – SO239 Antenna Output connector
- RTX – SO239 Transceiver input connector
- ALC – ALC output level adjustment
- ALC – ALC output connector RCA / Phono socket
- PTT – PTT Input Connector RCA / Phone socket (Active Low)
- IEC European AC input socket
- AC Fuse receptacle (2x4A (230Vac) 5x20mm, Fast, glass fuses)
INSTALLATION
Carefully remove the amplifier from it’s shipping carton and inspect for any damage. The amplifier should be installed in a place that allows good ventilation and provides a suitable base to support it. Failure to allow for good ventilation will cause the amplifier to overheat and shut down prematurely. Air is drawn into the amplifier from both the underside and top cover of the amplifier so do not place any objects underneath or on top of the amplifier that may restrict these intakes.
A short 50 ohm patch lead should be used to connect the output of the
transceiver to the RTX input ( ) on the rear panel. The length of this cable
is not critical but should be as short as practically possible. The ANT output
( ) SO239 connector should be connected to a resonant antenna suitable for the
band being used. ( If the antenna is not resonant the output should be
connected to a SWR / Power meter and then to a suitable Antenna Tuning Unit
(ATU/AMU).
Verify that the antenna / ATU being used is suitably rated for the power
output of the amplifier.
(The VSWR of the antenna should not change very much from low or high power
use).
If the antenna requires matching for the transmission frequency this should always be carried out at low power before the amplifier is switched to Operate mode.
The amplifier may be used with or without the PTT input ( ) connected to the transceiver however the default state of the BLA350 plus is that the PTT must be connected in order to amplify the signal. It is always recommended especially for SSB and CW modes that the PTT connection is made, however if the transceiver has no PTT output facility then the amplifier may be used without. See VOX menu.
The BLA350 plus may also have it’s ALC output ( ) connected to the transceiver in order to regulate the input power supplied to the amplifier. See ALC menu.
The output power of the drive radio, if no ALC connection is made to the transceiver , must be reduced manually on the transceiver to 10W, if the transceiver is capable of more power.
Connection to the AC supply.
The BLA350 plus features an internal power supply and can operate from the mains AC network with a voltage between 200 and 250Vac 50/60Hz. Before connecting the BLA350 plus to the AC network verify that the AC voltage is in accordance with that which is printed on the rear panel of the BLA350 Plus.
The use of the BLA350 Plus with an AC line voltage outside of that stated may result in permanent damage. The warranty does not cover damage sustained from this condition or from the use of incorrect fuses.
The BLA350 must be connected directly to the AC network with the supplied AC cable, The use of adapters, extension cords should be avoided.
Ground:
It is beyond the scope of this manual to provide a definitive guide into the
controversial subject of RF grounding, as it is a subject all to itself and
very much depends on how the equipment is connected and the type of antenna
used. There are both arguments both for and against the stereotypical RF
station ground. In addition to this is that lightning and static protection
for the antenna is an additional subject in itself, however this should be
kept external to the building and will not be covered here. There are many
good articles about correct station grounding both online and in all of the
usual publications on Ham Radio from the ARRL and RSGB etc. As output power
increases this becomes much more of a safety factor and should not be ignored!
The classical RF ground consists of a series of ground rods driven into the
ground over a suitably large area, connected together with heavy gauge wire /
copper strap and situated as close as possible to the radio installation, to
which every piece of equipment has a heavy gauge wire or strap connecting it
to RF ground. If using copper particular attention should be made to the fact
that copper corrodes and as it does, loses its conductivity properties so a
certain amount of maintenance will be required. Copper braid stripped from
coaxial cable is not a good idea, if the cable is left intact with both the
centre conductor and outer insulation present it may be utilised as a single
conductor for ground connections but removing the braid will make for a poorer
RF conductor and will allow corrosion to commence. There are many ready made
copper braids that are manufactured especially for this use.
The distance of the RF ground to the radio installation and also the length of
the individual connections from equipment to the RF ground are very important
and depend on the frequency in use. They must be made as short as practically
possible and much less than a 1/4 of a wavelength. At 10m this may already
present problems as 1/4 of a wavelength is 2.6m (28.5MHz).
If you have a 1/4 wavelength ground connection this will in fact present a
high impedance and will impede the flow of RF to ground.
Antenna type, (Balanced or unbalanced), fed with coaxial cable or balanced
feeder, proximity of the antenna to the radio installation, Antenna tuners and
BALUNS etc. All have an effect on system performance and safety. Typical
examples are unbalanced antennas that cause RF to return back along the
outside of the coaxial cable screen and thus the equipment connected to it.
One possible cause of ‘RF in the shack’. And can create many different issues,
such as tingling to the lips when touching a metal microphone grille, or a
tingling sensation when touching the CW key or metal equipment chassis,
rebooting computers, RF distortion on the transmitted audio, etc .
Just because your station functions or appears to function with out any of the
above issues at low power, doesn’t mean that these problems are not present or
that the problem is with the power amplifier.
Never ever use a metal gas pipe as your station ground connection! Cold water
pipes are often not suitable either.
Warning
Dangerous high voltages exist inside the amplifier and as such we recommend that the cover only be removed by qualified service technicians. Before removing the cover from the amplifier it is essential that the AC power cable, coaxial cables to the antenna and transceiver are disconnected. If during operation it is noticed an abnormal noise or odour, switch off the amplifier immediately and check all of the connecting cables and if necessary return to an authorised service centre for testing. Do not subject the amplifier to physical shock, high humidity, dusty environments or excessive heat. Periodically clean any accumulated dust from the amplifier especially around the ventilation grilles / fan intakes. Do not exceed more than 14W on the input to the amplifier. Excessive drive may cause damage and invalidate the warranty.
Operation
CW Operation
The BLA350 Plus utilises conventional relays for RX / TX switching and so due to the finite switching time, (20ms), ‘CW Full Break-In’ may not be used. It is recommended that the PTT cable from the transceiver is connected to the amplifier and that the ‘CW delay’ on the transceiver is adjusted accordingly so that when the key is pressed there is a predetermined delay to allow the BLA350 Plus RTX relay to switch from RX to TX before RF appears on the input.
Initial settings
If required it is necessary to tune the antenna before utilising the
amplifier. This may be carried out with the BLA350 plus either switched off,
(Switch ), or in ‘Standby’ mode, (Standby displayed on the LCD display) ( ).
The output power of the transceiver should be adjusted to a suitable level 10W
or the ALC connection made between the transceiver and BLA350 Plus and
adjusted accordingly. See ALC menu. Set the front panel controls in the
following positions:
MAIN ON/OFF: OFF
Stby / ON: OFF
LPF Selector: Any position
AUTO / MAN: AUTO
Standby
Switch the power switch MAIN, ( ), to ON. The LCD display, ( ), and Output
Power meter ( ) backlight will illuminate. In this mode the BLA350 Plus is in
Standby mode and will not switch to TX (Amplify the incoming signal from the
Transceiver), if the transceivers PTT is pressed.
The LCD Display shows:
The first row indicates the state of the amplifier, (Standby), and the status of the Low Pass Filter selection, either Auto or Manual. The second row shows the current temperature of the amplifiers heat sink close to the RF Transistors, and the currently selected filter. If the switch AUT / MAN, ( ), is set to MAN then it is possible to change the filter selection manually using the band selector switch ( ).
MENUS
When the amplifier is in Standby mode, it is possible to access the BLA350
plus settings menu. Press briefly the OK ( ) switch. It is now possible to
access all of the menus by repeatedly pressing OK until the desired menu item
is located.
To enter a specific menu press briefly the SET ( ) switch. To exit a menu item
without saving any changes press the Stby / ON ( ) switch to ON and then if
required back to Stby. Or press the OK, ( ), switch repeatedly unit the ESC
menu is displayed and then press SET. To change any parameters press the SET (
) switch. To save any modification to the menu parameters press OK, ( ),
immediately after a modification is made. An asterisk ’*’ is displayed on the
LCD display to indicate the currently active parameter.
ALC
If the ALC connection is made between the BLA350 Plus amplifier and the transceiver this menu is used to adjust the output power of the transceiver to that required for the BLA350 Plus. (10W)
To begin set the trimmer on the rear panel ( ) to about mid travel, using a small flat bladed screwdriver
Briefly press the SET switch ( ) and the LCD display will indicate, as shown above, the current input power. ALC adjustment should be made in either CW or FM mode to provide a constant carrier that will enable easier adjustment of the drive level. (The transceiver initial power level may be set to full power if not more than 100W). Transmit with the transceiver and at the same time rotate the ALC trimmer on the rear panel of the BLA350 plus until the power is set to 10W then press briefly the ’OK’ switch ( ). At this point when the ALC cable is connected.
The BLA350 Plus will regulate the output power of the transceiver to 10W or whatever input power has been set in the ALC menu. Do not exceed 15W input for the BLA350 plus.
Note: It is recommended to test the input power after ALC adjustment on various bands to make sure that the output power of the transceiver remains at the set value. On some transceivers the power will change despite the ALC voltage remaining constant. If the change from band to band is excessive it may be better to not use the ALC connection and regulate the output power of the transceiver manually directly on the transceiver.
Temp
This menu allows the unit of temperature, Celsius / Fahrenheit to be selected. Press SET ( ) to enter the menu and SET ( ) to alternate between Celsius and Fahrenheit then press OK ( ) to save and exit the menu.
Int. VOX
Int., (Internal), VOX when enabled allows the BLA350 Plus to be used if the transceiver does not have a PTT output. There are two Options ‘Disabled’ and ‘Enabled’. The BLA350 Plus default setting is ‘Disabled’ from the factory. It is recommended that for CW and SSB that the external PTT input is utilised. If Int. VOX is enabled see also menu SSB Delay below.
SSB Delay
Allows the delay time from TX to RX to be set when using the BLA350 Plus internal VOX. When using SSB this avoids the amplifier returning to RX state between pauses in speech.
The default setting is 500ms, (0.5sec), cycle through the choices 0,100,250,500,750 and 1000ms by pressing the SET, ( ), switch and select the selected choice by pressing the OK, ( ) Switch.
Fan Speed
The cooling fans operate in conjunction with the heat sink temperature. It is possible to change the way this occurs and hence the operating of the fan when in use:
Quiet Mode
In this mode, ON, the fans only operate when the temperature reaches 40°C.
When set to, OFF, (the default setting), the fans are continually running at
low speed until the temperature increases to 55°C at which point they will
increase in speed.
Max Speed
When set to ,ON, the fans will run at maximum speed for 5 seconds, this helps
to clean any accumulated dust from the heat sink. It is suggested this
function is carried out periodically.
Man Setting
It is possible to adjust the speed of the fans when the heat sink temperature reaches 55°C. There are 9 levels which relate to 20% and 80% of the maximum speed. The default setting is 5.
Dimmer
Adjust the brightness of the LCD back light between two levels, High and Low. Default Setting is High.
Info
Selecting this menu displays the current version of the firmware.
Default
This menu allows the user to return all parameters back to factory default setting. Press OK, ( ), to restore default settings.
ESC
Press OK, ( ), to exit the menu system and return the amplifier to Standby.
OPERATE
Switching Stby / ON, ( ), to ON, switches the amplifier to Operate mode and the amplifier is now active.
To use the amplifier it is sufficient to position the switch AUT / MAN, ( ),
to AUT (Automatic band filter selection), Ensure that the PTT, ( ), is
connected from the output of the transceiver to the input of the BLA350 Plus
and that there is a suitable antenna connected to the ANT, ( ), output
connector.
In this mode all of the functions of the amplifier are fully automatic, When
the PTT is pressed on the transceiver, the amplifier will automatically
measure the input frequency and set the low pass band filter accordingly. If
the operator changes the operating frequency the amplifier will automatically
change the band filter if required.
LCD Display ([)
The first row of the display shows the state of the BLA350 Plus amplifier: Whether in Standby or Operate mode and whether the band filters are in Auto or Manual selection mode. The second row shows the temperature of the heat sink and the currently selected Low Pass Filter.
Analogue Power Meter (b)
Displays the output power in Watts RMS.
Front Panel LED’s
ON (c)
Illuminates GREEN in Operate mode indicating that the amplifier is ready to
use.
TX (d)
Illuminates RED when the amplifier is in Transmission.
Warning (e)
Illuminates RED indicating that there is a problem with the amplifier and the
LCD Display (1) will report the nature of the error.
MAN (f)
Illuminates YELLOW when the user has selected manual filter selection. In this
condition the user must select the correct output filter. Failure to do so
will result in an error if the currently selected filter is not suitable for
the transmission frequency.
Front Panel Controls
All of the front panel controls should only be operated when the amplifier is not in transmission.
Stby / ON (\)
Switches the amplifier between Standby, (Stby), and Operate, (ON), modes.
OK / SSB (])
When in Standby mode pressing this switch the menu list is accessed. Press
repeatedly to cycle through the menus. In Operate mode selects if the SSB
Delay is active or not when the Internal VOX is activated. (No external PTT
connected). When active the letter ‘S’ is shown on the LCD display in the top
right hand corner
SET (^)
This switch is active only in Standby mode. It is used to change parameters in
the menu system.
AUT / MAN (_)
Allows the user to change between Automatic or Manual Low Pass Filter
selection. In manual mode the filter is selected by rotating ( ) to the
desired filter.
MAIN ON / OFF (a)
AC mains power switch. When the amplifier is not in use this should be set to
OFF.
Protection
The BLA350 Plus features several protection circuits that will protect the
amplifier from damage. These include: Excessive input power, Excessive
transistor temperature, Excessive output VSWR and incorrect filter selection.
Should one of the above conditions occur the amplifier will automatically
disable operation, returning the amplifier to Standby mode and will sound an
audible alarm at the same time as showing the error message on the LCD
display. The Warning ( ) LED will also be illuminated.
Excessive Input Power
If the input power from the transceiver is about 13W the red warning LED ( )
will illuminate and the LCD display will return the following message.
If the input power increases above 15W the amplifier will shutdown , an
audible error tone will be emitted and the Warning LED ( ) will remain
illuminated.
The LCD display will return the following message:
It will be necessary to reset the amplifier, this can be done by switching the amplifier back to Standby and then back to Operate using switch ( ).
Over Temperature
The temperature at the point of contact between the transistors and heat sink
regulates the speed of the cooling fans.
At between 65°C and 74°C fan speed is high. When the temperature increases to
75°C the amplifier will sound the over temperature alarm, The fan speed will
run at maximum, an audible tone will be emitted and the warning LED (e)will be
illuminated.
If the temperature increases above 80°C the amplifier will shutdown, the audible warning will continue and the alarm LED will remain illuminated. The amplifier will return to normal operation automatically when the temperature drops below 60°C. It is recommended that under this condition the BLA350 Plus is not switched off, as the cooling fans will cool the amplifier down much faster.
Excessive VSWR
The BLA350 Plus measures both the forward and reflected power at the antenna
output and also at the input to the low pass filters. The antenna VSWR
protection features a lightning fast hardware protection circuit. However both
protection circuits are also monitored by the microprocessor.
The amplifier will protect itself if the wrong band filter is selected or if
the antenna VSWR is excessively high.
The amplifier operates at its best when the antenna VSWR is below 1.5:1. If the antenna VSWR increases from 1.5:1 to 2.0:1 the amplifier can still be used however the reflected power will be dissipated by the transistors which will cause more heat to be generated.
If the antenna VSWR increases about 2.0 to 2.5:1 the amplifier will protect itself by shutting down and returning to Standby state. An error tone will be emitted , the warning LED ( ) will be illuminated and the LCD Display will show the following error message:
To reset the amplifier it is necessary to switch it OFF and back ON again with MAIN ON / OFF switch ( ).
Filter Error
The Low Pass Filters are controlled and monitored by the microprocessor in
order to verify that the correct filter is selected. If the user incorrectly
selects a low Pass Filter in manual mode the amplifier will signal a warning
and protect itself by shutting down and returning to Standby state. An error
tone will be emitted , the warning LED ( ) will be illuminated and the LCD
Display will show the following error message:
To reset the amplifier it is necessary to switch it OFF and back ON again with MAIN ON / OFF switch ( ).
Error Frequency
If the input frequency to the BLA350 Plus is outside of the specified limits
the amplifier will shutdown, the amplifier will be returned to Standby
condition, an audible alarm will sound, the warning LED ( ) will illuminate
and the LCD display will show the following error message:
The figures below show the typical performance of the the BLA350 Plus amplifier. However due to component tolerances and AC supply voltage each amplifier will show some small variation compared to the data shown below.
Protection | Cause | LCD Display | Reset | LED | Note |
---|
Excessive I/P POWER
| Input Power >13W| Power TRX >13W| No Action| A *****| Reduce TX Power / Adjust ALC
Correctly
Input Power >15W| Error Power TRX| Stby / ON| A
Excessive TEMP| Temperature >80°C| Over Temp!| Automatic <60°C| A| Check
ventilation
of Amplifier
TXCR in TX when amplifier
is switched on
| TXCR IN TX at Amp Switch
On
| Error RF Input| Automatic| A| Stop Transmission
Excessive VSWR| Antenna VSWR >2.5:1| SWR >3.0| Stby / ON| A| Check
Antenna
VSWR
Harmonic VSWR| Filter Input VSWR >3.0:1| Harmonic SWR >3.0| Stby / ON| A| Incorrect Filter or
Antenna VSWR
Error Frequency| TX Freq. <1.5MHz or
30MHz
| Error frequency| Stby / ON| A| Check TX Frequency
Warning: Transmit Time.
High duty cycle modes such as FM and data modes, (RTTY / FT8 etc.), operate the amplifier at full power all of the time, unlike modes like SSB and CW that are either intermittent or only reach peak output for very short times. These high duty cycle modes will run the amplifier much harder and generate more heat in the same amount of time. It should be noted that the amplifier although capable of being used with these modes, should not be used continuously. We recommend that the transmission time should not exceed a couple of minutes in order to avoid excessive transistor junction temperature. The exact time for transmission in these modes will of course depend on numerous factors such as, the ambient temperature, how good the ventilation surrounding the amplifier is, if there is sufficient space for freely flowing air to circulate etc. If the ambient temperature is high this will reduce the total time in transmission. Common sense should be exercised if the heat sink temperature is high then sufficient time should be allowed for it to cool down before resuming transmission. For high duty cycle modes the amplifier may also be used at less than maximum output power by reducing the input drive level. This will reduce dissipation and also allow the amplifier to be used for longer periods.
Input Drive and Power output.
The BLA350 Plus should give full output power with approximately 10 12W of drive. Excessive input power should be avoided and the amplifier always used in a responsible manner. If excessive input power is used the amplifier will signal an error and above 15W input it will return an alarm signal and block transmission. It is important to understand that accidental input of 100W from the transceiver should be avoided and may cause damage to the amplifier!!!!
Maximum Output Power Considerations.
Running the amplifier a little under maximum output power will allow the amplifier to run cooler and make it more reliable for many years of use.
As an example consider the following situation.
1 ‘S’ point on a receiver is usually approximately calibrated at 6dB so for example the difference between S5 and S7 is 2 ‘S’ points so 12dB
The difference between 10W and 300W is about 14.8dB which is a big increase to your signal if using the same antenna. Now let’s say for example you run the amplifier at a moderate 250W by reducing the input drive. The difference between 300W and 250W is less than 1dB which when you compare this to 6dB for 1 ’S’ point is actually very little and as the amplifier is not running at maximum power will generate less heat, and produce a cleaner output with less distortion that will actually make a difference at the distant receiver.
Warranty
RM Costruzioni Elettroniche srl Guarantees that this product is free from
manufacturing defects both components and workmanship for a period of time
specified by the law. The warranty commences on the date of purchase. Any work
undertaken for the warranty must be carried out by RM Costruzioni Elettroniche
srl or an authorised service centre. The costs of transportation, duties and
insurance between the client and RM Costruzioni srl or the approved service
centre are the responsibility of the client.
The warranty must be requested to the distributor or reseller where the
amplifier was originally purchased.
In the case where the original distributor or reseller no longer exists or
deals with RM products, RM Costruzioni Elettroniche srl will communicate the
nearest distributor or reseller to use, or in the instance where this is not
possible or convenient, RM Costruzioni Elettroniche srl will honour the
warranty directly. If any repairs are carried out outside of an approved
service centre this will void the warranty and RM Costruzioni Elettroniche srl
will not be responsible for any incurred charges. The warranty will only be
honoured if the amplifier has been used for its intended purpose as described
in this user manual, that the amplifier is returned with its original purchase
receipt, returned in its original packing container, that the serial number is
readable, unchanged and that the warranty seals remain intact.
The warranty does not cover the MOSFET power transistors or any aesthetic
damage.
Any change to the warranty either by local law or that made by the distributor
or reseller directly with the client will be the sole responsibility of the
distributor or reseller and not by RM Costruzioni Elettroniche srl. In the
event of any argument between parties resulting in legal action. It will be
agreed to be settled in a court of law in Bologna (Italy).
The purchase of this product assumes that the client has accepted the terms
and conditions of this warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>