BVF Heating L-1 Smart Outdoor Thermostat User Manual
- June 3, 2024
- BVF Heating
Table of Contents
BVF Heating L-1 Smart Outdoor Thermostat
SPECIFICATION
- Operating voltage: 230V AC, 50/60 Hz
- Capacity: 3600W/16A
- Backup storage: EEPROM
- IP protection rating: IP 30
- Housing: Black
- PRG options: 7 days, unlimited cycles
- Housing dimensions: 86 mm × 86 mm × 15 mm
- Relay inst. dimensions: Ø 65 mm diameter, standard
ATTENTION!
The thermostat can be placed indoors only!
LED INDICATOR STATUSES
OVERVIEW
This thermostat is a new generation thermostat without any physical sensor. Our sensorless technology based on real time weather conditions from application. For normal operation you need to connect the L-1 thermostat with Tuya Smart application on your phone. After connection the thermostat can automatically switch the heating on and off based on weather condition.
WIFI CONNECTION
Please scan the QR code for detailed instruction or visit
bvfheating.com/L-1
AUTO MODE
You can see below the conditions when the thermostat will start heating. For this feature you need to enable auto mode in the app.
- Temperature <1 °C, and humidity >70% (both two condition required)
- Light snow
- Snow
- Freezing fog
- Sleet
- Fog
- Heavy snow
- Blizzard
- Light to moderate snow
- Light snow shower
- Moderate snow
- Snow shower
NOTIFICATION MODE
The application sends notification if the weather conditions justify starting
the heating.
PROGRAM MODE
In the application you can set heating schedule for every day of the week.
MANUAL OR OFFLINE MODE
If you don’t want to use your phone to change mode on the thermostat you can
do it manually with the touch button. For each touch the thermostat switches
to the next mode cyclically.
- Heating off
- Heating on
- Heating on for 1 Hour
- Heating on for 2 Hours
- Heating on for 3 Hours
- Heating on for 4 Hours
INSTALLATION & WIRING DIAGRAM
The thermostat is designed to be flush mounted and requires a back box of 35mm (minimum depth) to be sunk into the wall prior to installation.
ATTENTION!
The thermostat can be placed indoors only!
- Using a small screwdriver, slightly loosen the screw from the bottom face of the thermostat. Then carefully separate the front half from the back plate.
- Place the thermostat front somewhere safe.
- Terminate the thermostat as shown in the diagram.
- Screw the thermostat back plate securely into the back box.
- Clip the front of the thermostat onto the back plate.
TROUBLESHOOTING
Please scan the QR code for troubleshooting information or visit bvfheating.com/L-1
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>