Thornwave Labs Inc PowerMon Bluetooth Low Energy Advanced Battery Monitor DC Power Meter User Manual
- June 4, 2024
- Thornwave Labs Inc
Table of Contents
Bluetooth Low Energy
Advanced Battery Monitor / DC Power Meter
USER MANUAL
BRIEF
PowerMon is a Bluetooth Low Energy advanced battery monitor / DC power meter. This tool can be used in any battery or DC-powered circuit to monitor, analyze, and log the most important electrical parameters: two voltages (0-72V), current (0-60A using the integrated shunt or up to 1,000A using an external shunt), power (W), energy (Wh), battery charge (Ah) and temperature. Many other parameters are computed: the battery state of charge (% SoC), remaining time on battery at current load, and a multitude of battery / DC power statistics. The device can log the data for up to 3 years, allowing for advanced data analysis and troubleshooting. All battery monitors on the market that log data, do it inside the mobile application but PowerMon logs it inside internal memory. This makes PowerMon superior. The data logging function is only available for devices with hardware revision 2.3 and up (sold after 2019). The device can drive a mechanical or solid-state relay which allows it to function as a low voltage disconnect, high voltage disconnect, over-current disconnect, temperature controller, battery isolator in multiple battery systems, remote on/off switch, timer, and generator control. A mobile device running either Android or iOS and the PowerMonX app (available for free on Google Play Store and Apple App Store) is required for using this device. An older app, PowerMon, is also available to support older devices (pre2019 models).
FEATURES
- Measures two voltages, current, power (W), charge meter (Ah), energy (Wh), and temperature
- Operates at up to 72V and 60A of continuous current (75A peak current) using the integrated current shunt
- Can sense up to 160mV of voltage drop across an external current shunt allowing current of up to 1,000A to be measured
- Fully differential input for the current shunt, allowing it to be mounted either on the negative side or on the positive side
- Data logging for up to 3 years (for hardware revision 2.3 and up)
- Can drive one relay or SSR (solid-state relay)
- Low/high voltage disconnect
- Over-current disconnect
- Low/high-temperature disconnect
- Generator control
- Battery isolator for dual battery systems
- The battery monitor (battery fuel gauge), displays the state of charge in percentage and the remaining time on battery at the current load
- Works with all types of batteries
- Lithium iron phosphate battery charge manager
- Timers
- Can use an external temperature sensor
- User/master password protection
- Very low power consumption (see Performance Parameters)
- Bluetooth LE radio with internal antenna and long-range
- 8-pole terminal block for connecting to the system that will be monitored
- ABS plastic enclosure with mounting flanges, completely enclosed in epoxy potting compound
- Measures only 3.0″ x 1.55″ x 0.75″ (76mm x 39mm x 19mm) including the mounting flanges.
- Weatherproof
- The Free PowerMonX app is available for Android and iOS. Old PowerMon app is available as well.
- Highly configurable. It achieves top performance with all kinds of current shunts and batteries
TYPICAL APPLICATIONS
- RVs, boats, off-the-grid cabins
- Solar and wind alternative energy systems
- Vehicle batteries, battery isolator
- Backup electrical systems
- Lithium Iron-Phosphate battery charge manager
- Automation: solar irrigation systems, solar streetlights, general-purpose DC timers
TERMINAL DESCRIPTION / INTERNAL DIAGRAM
No. | Name | Terminal Description |
---|---|---|
1 | GROUND | System ground (battery negative, chassis) |
2 | MF | Multi-Function (for hardware revision 2.2 and up). Supports pushbutton |
input or external temperature sensor
3| RELAY| Relay output. It drives a mechanical or solid-state relay. To turn
the relay on, the device is grounding this terminal internally
4| ES2| External shunt connection. When using the internal current shunt
connect this terminal to ES1 (terminal 5)
5| ES1| External shunt connection. When using the internal current shunt
connect this terminal to ES2 (terminal 4)
6| DNC| DO NOT CONNECT!
7| V2| Second monitored voltage. Can measure the voltage of a second battery.
8| V1| This is the main voltage that will be monitored. The device also draws
its own power from this terminal.
9| IS1| Internal shunt connection. Do not connect if using an external shunt.
10| IS2| Internal shunt connection. Do not connect if using an external shunt.
SPECIFICATIONS
Absolute Maximum Ratings 1,2
The maximum voltage at the V1 and V2 terminals| +65V (hw rev 2.0)
+72V (hw rev 2.2 and up)
** Maximum voltage at the RELAY terminal| +18V (hw rev 2.0)
+32V (hw rev 2.2 and 2.3)
+72V (hw rev 2.5 and up)
The maximum current through the RELAY terminal (maximum relay coil current)|
0.5A (hw rev 2.3 and under)
2A (hw rev 2.5)
The maximum current through IS1 and IS2 (using the integrated current shunt)|
60A continuous, 75A peak
Maximum current (using an external current shunt)| depends on the external
shunt (up to 1,000A)
Maximum differential current sense voltage ES1 to ES2 (using an external
shunt)| -72V to +72V
Maximum common mode current sense voltage (ES1 -ES2, IS1 – IS2)| -2V to
+72V
Operating temperature| -30°C to +85°C**
1. Stresses greater than those listed under “Absolute Maximum Ratings” may
cause permanent damage to the device.
2. All voltages are referenced to ground (terminal 1) unless otherwise
specified.
Performance Parameter | Value |
---|---|
Measured voltage (V1, V2) | **0 to 60V (hw rev 2.0) |
0 to 72V (hw rev 2.2 and up)
Measured voltage accuracy| max 0.5%, typ. 0.25% max 0.2%, typ. 0.15%
(hw rev 2.5 and up)
Measured current (using the integrated shunt IS1, IS2)| 0 to 60A
Current monitoring accuracy (using the integrated shunt)| 1% – without
calibration
0.25% – with calibration
Integrated current shunt resistance| 0.5 mOhm / ±1%
The measured differential voltage on ext. shunt input (ES1, ES2)| -160mV to
+160mV
Current monitoring accuracy (using external shunt)| depends on external
shunt precision, typically 0.25% (with**
calibration)
Temperature| 1°C / 1°F resolution
Data logging sample rate (for hardware rev 2.3 and up)| 1 sec – up to ~18
days 2 sec – up to ~36 days 5 sec – up to ~90 days
10 sec – up to ~180 days 20 sec – up to ~1 year 30 sec – up to ~1.5 years
1 min – up to ~3 years
Current draw (current consumed by the device) (using the latest firmware
version) at 12V at 24V at 36V at 48V at 60V at 72V| hw rev 2.5 and up
5.4 mA 3.4mA
5.7 mA 3.5mA
6.0 mA 3.6mA
6.3 mA 3.7mA
6.6 mA 3.8mA
6.9 mA 3.9mA
COMPLIANCE STATEMENTS
FCC
ATTENTION: Changes or modifications not expressly approved by Thornwave
Labs Inc could void the user’s authority to operate the equipment.
ATTENTION: This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions: (1) this device may not cause
harmful interference and (2) this device must accept any interference
received, including interference that may cause undesired operation.
IC RSS-102 RF Exemption
This system has been evaluated for RF Exposure per RSS-102 and is in
compliance with the limits specified by Health Canada Safety Code 6.
IC RSS-Gen 8.4
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
SAFETY INSTRUCTIONS
Warning!
Read all the instructions and cautions before using the PowerMon device.
Thornwave Labs Inc does not assume responsibility for any injury or property
damage caused by improper installation, bad wiring, or use of PowerMon outside
of its intended purpose. The device should be installed by a professional.
Warning!
The PowerMon device should not be used for any medical purposes, life-
sustaining equipment, safety applications, or any application where equipment
failure can cause injury, death, fires, or any other hazard.
Warning!
There are no serviceable parts or fuses inside the power meter! Do not
disassemble or attempt to repair! The unit operates with voltages up to 72V
which can be lethal or cause serious and permanent injury.
Warning!
Do not submerge under water or other liquids. The device is weatherproof but
not waterproof.
Warning!
The device is to be connected to DC circuits only, not exceeding 72V and 60A
(using the integrated current shunt). Failure to do so will result in
equipment damage. Higher currents are supported when using an external current
shunt. Confirm that all connections are tight to avoid excessive heating,
sparks, or fire. Never connect the V1 terminal to a power source without using
a fuse or circuit breaker. A 0.1A to 2A fuse or circuit breaker is required.
Warning!
Batteries are dangerous! Do not short-circuit a battery or the power meter.
Batteries can produce flammable and explosive gases and can generate extremely
high currents that can lead to serious consequences including explosion, fire,
damage to equipment, personal injury, and even death. It is the user’s
responsibility to operate the equipment in a safe manner. Do not charge
batteries in an enclosed environment unless allowed by the manufacturer of the
battery. Never connect a load to a battery without using fuses or circuit
breakers, properly sized for the wires/equipment.
Warning!
Although PowerMon coupled with a relay can disconnect power if an over-current
condition occurs, it should not be used to replace circuit-breakers. A
properly rated circuit breaker or fuse should be used to protect the load and
the wiring!
Warning!
PowerMon cannot be used as a charge current limiter or LiFePO cell balancer. A
properly sized battery charger is required to recharge LiFePO batteries.
Thornwave Labs Inc. does not assume any responsibility for expensive battery
damage.
OVERVIEW
Installation. Powerman was designed to be installed inside an equipment
bay, or inside a plastic enclosure where it will be protected from water, high
humidity, condensation, and battery or other corrosive gases. The device
should not be installed inside an all-metal enclosure since that will
significantly reduce the Bluetooth range. Although the device is potted using
epoxy, it is resistant to humidity and battery corroding, the terminal block
is not. Use 16-20 AWG wires to make all the required connections in the green
terminal block.
Device power. The Powerman device is drawing its supply power from the V1
terminal. Make sure that V1 is always present. If the device loses power, it
will forget the internal clock. Terminal 1 (GROUND) should be connected to the
system ground (usually system negative).
Integrated current shunt. When using the integrated current shunt, the
ES1 and ES2 terminals should be tied together using a piece of wire bent in a
U shape. The current to be monitored should pass through the internal shunt
(IS1 – IS2 terminals). An internal current shunt of 0.5mOhm exists in between
these two terminals. The aluminum hex set screw terminal blocks (IS1 and IS2)
can accept wires up to 6AWG in size. To minimize voltage drop on wires and
connections, use the thickest wires that fit inside the terminals (6AWG). The
common-mode voltage at IS1 and IS2 can be between -2V and +72V relative to the
ground, allowing the current shunt to be placed either on the positive side of
the circuit or the ground wire (negative side). The current reading should be
positive when charging the battery and negative when discharging. If the
current sign is reversed, swap the IS1 – IS2 wires, or simply change the “Flip
Current Sign” switch in the device configuration.
External current shunt. To monitor a large current, an external current
shunt can be used. This method allows monitoring current up to 1,000A. The
external current shunt should be connected to the ES1 and ES2 inputs. To avoid
noise, the wires should be as short as possible. Twisting the sense wires
reduces noise even further. The IS1 and IS2 terminals should be left
unconnected. The common-mode voltage at ES1 and ES2 can be between -2V and
+72V relative to the ground, allowing the current shunt to be placed either on
the positive side of the circuit or the ground wire. The current reading
should be positive when charging the battery and negative when discharging. If
the current sign is reversed, swap the ES1 – ES2 wires, or simply change the
“Flip Current Sign” switch in the device configuration.
Zero the current offset. Due to the high sensitivity of the current
measurement circuitry inside the PowerMon device, the value displayed may have
a small offset (measurement is different than zero even when the actual
current is zero). Typically, this is less than 0.1A. In situations where the
measurement precision is critical, the offset can be reduced to zero. To do
this, disconnect the wires from the load side of the shunt or make sure the
actual current is zero (turn all the loads off). This can also be achieved by
turning the power relay off from the mobile application (in case the system is
wired with a relay). Long-tap on the “Current” tab and then “Zero Current”.
The operation will take 3 seconds to complete during which do not allow any
current to pass through the device. Also, do not zero the current offset if
the actual current is different than zero. Doing so will introduce a very
large offset. Any current that is flowing through the shunt when the Zero
Current operation is performed will become the new indicated zero.
Current calibration. Typically, the device can measure current with
better than 1% precision. If higher precision is required, the current
measurement can be calibrated allowing up to 0.25% of precision. To calibrate
the current reading, an amp-meter capable of measuring current with a
precision better than 0.25% is required. Connect the amp-meter leads in series
with the shunt and read the actual value of the current. Long-tap on the
“Current” tab, tap on “Calibrate Current” and then type the actual value
measured by the amp-meter.
The sign of the current does not matter. Once calibrated, the only way to
change the calibration is to reset the device to factory defaults or re-
calibrate. The device will not accept a calibration current different from the
actual current reading by more than 10%.
P ower relay control. Powerman can drive a power relay (either mechanical
or solid-state) using the RELAY output (terminal 3). When active (relay turned
on), the RELAY terminal is internally connected to the ground by the device.
The relay coil should be connected between the power supply (battery positive,
typically) and the RELAY terminal. The low/high voltage disconnect,
temperature disconnect, over-current disconnect, and generator control
functions require the use of a relay / SSR (Solid State Relay).
Low voltage disconnect. When this feature is enabled and the battery
voltage drops below a specified threshold, the device turns the relay off,
disconnecting the loads to protect the battery from over-discharge. To
disconnect the load the voltage must be below a threshold for a configurable
amount of time. This feature helps in situations like cranking an engine or a
short high current load that causes the battery voltage to momentarily drop.
The device will re-engage the power relay a configured amount of time after
the voltage goes back above the connect threshold.
This feature allows the PowerMon to also operate as a battery isolator. The
relay is used to connect the house battery in parallel with the starting
battery (see wiring diagrams at the end of this document). The LVD filter
value should be set to 5000ms. The disconnect threshold should be set to 13.2V
and the connect threshold to 13.6V. When the engine is started and the
alternator charges the starting battery, the voltage will start increasing.
When the voltage reaches 13.6V (the connect threshold) the relay engages and
connects the house battery to the starting battery, allowing all batteries to
be charged. When the engine is stopped the voltage will drop below 13.2V (the
disconnect threshold) and the relay disengages, isolating the house battery
from the starting battery. The house battery voltage can be monitored using
the V2 input. Note that the thresholds (13.6V and 13.2V) are just an example.
They can be configured to best fit the application.
High voltage disconnect. This function is similar to the low voltage
disconnect, but as the name suggests it will disconnect the load when the
voltage goes above the disconnect threshold and will reconnect the load when
the voltage goes below the reconnect threshold. This mode can be used together
with the low voltage disconnect.
Over-current disconnect. When this feature is enabled and the measured current
increases above a user-specified trip value, the device disconnects the load,
protecting the batteries and load from over-current. The device will re-engage
the power relay a configured amount of time after the current drops below the
trip threshold.
Battery fuel gauge. PowerMon computes the battery state of charge and
various statistics. This is accomplished by using coulomb counting. For the
battery fuel gauge to work properly, the charging current should display
positive, and discharging current should display negative. If the displayed
current sign is wrong, it can be swapped by changing the “Flip Current Sign”
switch in the device configuration.
Small errors in measurement and integrating current over long periods of time
will introduce errors in the state-of-charge estimation. This is normal and
expected. For this reason, the device will re-synchronize its SoC counter with
the battery every time a full charge is performed. A full charge is detected
based on the chemistry of the battery but in general, it requires the voltage
to be higher than a threshold while at the same time the charging current is
lower than a threshold. The battery fuel gauge will also take into
consideration the Peukert effect. The next table shows the Peukert
coefficients used for various battery chemistries.
Battery Chemistry | Peukert Coefficient |
---|---|
Lead Acid – Flooded | 1.25 |
Lead Acid – AGM | 1.15 |
LiFePO4 | 1.05 |
Li-Ion/LiPoly | 1.05 |
LiFePO charge manager. PowerMon can manage the charging of a lithium iron
phosphate battery. This function cannot be used together with the other
disconnect functions. If enabled, the mobile app will automatically disable
the other disconnect functions. A relay must be placed in between the battery
and the charger, or power source used for charging (the vehicle alternator for
example). The function of this relay is to disconnect the charger from the
battery if a full charge is detected or the charger is turned off (the engine
is turned off for example). To use the LiFePO charge manager, connect the V1
input to the battery positive and the V2 input to the charger positive. The
internal shunt and the relay should be wired in between the charger and the
battery (see wiring diagrams at the end of this document).
The battery voltage and the total capacity of the battery in Ah should be
properly configured. At least one disconnect condition has to be true for at
least 2 seconds for the disconnect to take place. The connect conditions must
be true for the time specified in “Connect Time” for the connect to take place
(default is 10 seconds).
The following table shows the conditions used by PowerMon to decide whether to
connect or disconnect the charger from the battery (turn the relay ON/OFF).
Current refers to the current flowing in between the battery and the charger.
“C” refers to the battery capacity. Care should be exercised to ensure that
the current is positive when the battery is being charged and negative if it
is being discharged. If wired backward, use the “Flip Current Sign” option to
fix it.
Connect Conditions (10 sec. delay used)| Disconnect Conditions (2 sec.
delay used)
---|---
battery voltage (V1) less than 3.32V / cell
AND
charger voltage (V2) at least 0.2V above the battery voltage (V1)| battery
voltage (V1) greater than 3.65V / cell
–| charging current (I) less than C/100 or 1 Amp, whichever is greater
–| full charge is detected: battery voltage (V1) greater than 3.5V /cell
AND charging current (I) less than C/20
Internal clock. Powerman keeps track of time internally. The internal
clock can be set by tapping on the Device Clock tab for longer than one
second. The internal date and time will be updated using the system time
provided by the mobile device. If the internal clock is not set the device is
not logging data.
Timer function. The device supports controlling the relay using a set of
up to 16 timers. Each timer contains a start time, stop time, and repetition.
The start time specifies the time of day (HH: MM) when the relay turns on.
Stop time specifies the time of day when the relay turns off. A timer does not
need to have both the start and stop times. One of them can be disabled. This
kind of timer should be used in pairs: one turns the relay on and the second
one turns it off. `Repetition’ controls the days when a timer will trigger.
This can be either DoW (Day of Week) where the timer repeats on specific days
of the week or DoM (Day of Month) where the timer repeats on specific days of
the month.
Using multiple timers, users can create very complex time schedules.
Examples:
Timer1: START 4:50 PM, STOP 5:10 PM, REPETITION DOW Mon Tue Wed Thr Fri Sat Sun
This timer will run every day and turn the relay on for 20 minutes, from 4:50 PM until 5:10 PM
Timer2: START 8:00 PM. STOP: disabled, REPETITION DOW Mon Tue Wed Thr Fri Sat Sun
Timer3: START disabled, STOP: 7:00 AM, REPETITION DOW Mon Tue Wed Thr Fri Sat Sun
This set of timers used together will turn the relay on every day at 8:00 PM and turn it off the following day at 7:00 AM.
The same effect can be achieved using a single timer. This is just an example.
Timer4: START 12:00AM. STOP: disabled, REPETITION DOM: 1
Timer5: START disabled, STOP: 12:00AM, REPETITION DOM: 8 This set of timers used together will turn the relay on every 1st of the month at 12:00AM and turn it off 7 days later, on the 8th of the month at 12:00AM.
Configuration. The device configuration can be changed using the
PowerMonX app. The configuration parameters are grouped in categories based on
the function affected by these parameters.
General.
Shunt Specifications: The characteristics of the shunt used. If the
PowerMon internal shunt is used, the setting should be set to 60A / 30mV
(integrated). This is the default setting.
Max. Shunt Current (amperes) : The maximum current that the shunt is
expected to see. Typically, this is set to the maximum rated current of the
shunt. It can be set lower to potentially increase the resolution of the
reading. To do this it has to be set lower than the current that causes a
voltage drop of 40.96mV on the shunt. For example, a 500A / 75mV shunt would
develop a 40.96mV of voltage drop when the current passing through it is 273A.
If this value is set to less than 273A, the current resolution is increased by
4 times. This is done at the expense of the range of measurement. Obviously,
the maximum current PowerMon can now measure is only 273A.
Power Meter Voltage Source: The voltage used to calculate power and
energy. Voltage1 or Voltage2 can be selected.
Flip Current Sign: This allows the current sign to be flipped by
software. Can be used to correct the shunt being wired backward. Should be set
such that the discharge current is displayed as a negative value and the
charge current shows positive. This is a requirement for the fuel gauge to
work correctly.
Turn On at Startup: The default power status when powering the device. If
set to on, the relay will be turned on automatically when the device is first
powered up.
Trigger on Relay Active: If enabled, the device will turn the power on as
a response to the RELAY terminal being temporarily pulled to the ground using
a push button.
Invert Relay Logic: Enabling this option will invert the behavior of the
RELAY terminal: when the power is on, the RELAY terminal will be floating and
when the power is off it will be driven to the ground. When this option is
enabled “Trigger on Relay Active” is ignored (disabled).
Connect Filter (milliseconds): The duration of time in milliseconds the
LVD (Low Voltage Disconnect), HVD, and OCD (Over-Current Disconnect)
conditions must be removed for the PowerMon to re-engage the power relay.
MF Terminal Function: Selects the function of the MF terminal: push-
button input, data output, or external temperature sensor. The external
temperature sensors are only available for hardware revision 2.2 or higher.
Data Logging Mode: Configure the data logging sample rate. Possible
values are disabled, every second, 2 seconds, 5 sec, 10 sec, 20 sec, 30 sec,
or 1 minute.
Low Voltage Disconnect
LVD Voltage Source: The voltage used by the low voltage disconnect feature.
Voltage1 or Voltage2 can be selected.
LVD Disconnect Threshold (V): The voltage in volts below which the power
relay will disengage.
LVD Connect Threshold (V): The voltage in volts above which the power
relay can re-engage (after the connect filter time has passed). This must be
higher than LVD Disconnect Threshold.
LVD Disconnect Filter (milliseconds) : The duration of time the voltage
must be below the disconnect threshold for the relay to disengage. It is used
to filter voltage spikes.
High Voltage Disconnect
HVD Voltage Source: The voltage used by the high voltage disconnect feature.
Voltage1 or Voltage2 can be selected.
HVD Disconnect Threshold (V): The voltage in volts above which the power
relay will disengage.
HVD Connect Threshold (V): The voltage in volts below which the power
relay can re-engage (after the connect filter time has passed). This must be
lower than HVD Disconnect Threshold.
HVD Disconnect Filter (milliseconds): The duration of time the voltage
must be above the disconnect threshold for the relay to disengage.
Over-Current Disconnect
OCD Disconnect Threshold (A): The current in amperes above which the power
relay disengages.
OCD Disconnect Filter (milliseconds): The duration of time the current
must be above the disconnect threshold to disengage the relay.
Low-Temperature Disconnect
LTD Disconnect Threshold: The temperature below which the power relay will
disengage.
LTD Connect Threshold: The temperature above which the power relay can
re-engage (after the connect filter time has passed). This must be higher than
LTD Disconnect Threshold.
LTD Disconnect Filter (milliseconds): The duration of time the
temperature must be below the disconnect threshold for the relay to disengage.
High-Temperature Disconnect
HTD Disconnect Threshold: The temperature above which the power relay
will disengage.
HTD Connect Threshold: T he temperature below which the power relay can
re-engage (after the connect filter time has passed). This must be lower than
HTD Disconnect Threshold.
HTD Disconnect Filter (milliseconds): The duration of time the
temperature must be above the disconnect threshold for the relay to disengage.
Auto-off Timer: If enabled the power will turn off automatically after a
specified time since it was turned on has passed. This effectively becomes a
turn-off timer.
Auto-on Timer: If enabled the power will turn on automatically after a
specified time since it was turned off has passed. This effectively becomes a
turn-on timer.
Battery Fuel Gauge
Battery Voltage Source: The voltage used by the battery fuel gauge
feature. Voltage1 or Voltage2 can be selected.
Battery Chemistry: The chemistry of the battery used (Lead Acid
Flooded, Lead Acid AGM, LiFePO4, Li-Ion, Li-Poly).
Battery Voltage: The battery voltage (can be the standard 12V, 24V, 48V,
… or custom, in which case the number of cells in the battery can be
configured).
Number of Cells : Number of cells in the battery. 12V Lead Acid batteries
have 6 cells. 12V LiFePO4 batteries have 4 cells. If you have batteries
connected in series, add the number of cells in each of them. If batteries are
connected in parallel the number of series cells does not change. This is the
number of cells that contribute to the battery nominal voltage.
Total Battery Capacity: Battery capacity in Ah. If batteries are
connected in parallel, add their capacities. If batteries are connected in
series the capacity does not change. Disconnect on Battery SoC Threshold
(%): The device will disconnect power (turn the relay OFF) when the battery
state of charge becomes lower than this threshold (in percentage).
Connect on Battery SoC Threshold (%): The device will re-connect power
(turn the relay ON) when the battery state of charge becomes higher than this
threshold (in percentage).
Generator Control
Generator Control Voltage Source: The voltage used by the generator
control feature. Voltage1 or Voltage2 can be selected.
Turn On Based on Voltage: If enabled the generator will be turned on when
the battery voltage drops under a specified threshold.
Turn On Voltage Threshold (V): The threshold in volts below which the
generator will be turned on.
Turn On Voltage Filter (milliseconds): The duration of time the voltage
must be below the turnon threshold for the generator to be turned on.
Turn On Based on SoC: If enabled the generator will be turned on when the
battery SoC (State-of-Charge) drops under a specified threshold.
Turn On SoC Threshold (%) : The threshold in percentage below which the
generator will be turned on.
Turn Off Based on Voltage: If enabled the generator will be turned off
when the battery voltage increases above a specified threshold.
Turn Off Voltage Threshold (V): The threshold in volts above which the
generator will be turned off.
Turn Off Based on SoC: If enabled the generator will be turned off when
the battery SoC (State-of-Charge) increases above a specified threshold.
Turn Off SoC Threshold (%): The threshold in percentage above which the
generator will be turned off.
Turn Off Delay (minutes) : Delay applied between the conditions to turn
the generator off become true and turning the generator off. For example, if
set to 1 minute, the generator will stay on for an extra minute after the
voltage or SoC increases above the turn-off threshold.
LiFePO Charge Manager
Battery Voltage : The battery voltage (can be the standard 12V, 24V, 48V,
or custom, in which case the number of cells in the battery can be
configured).
Number of Cells: Number of cells of the battery. 12V LiFePO4 batteries
have 4 cells. If you have multiple batteries connected in series, add the
number of cells in each of them. If batteries are connected in parallel the
number of series cells does not change. This is the number of cells that
contribute to the battery nominal voltage.
Total Battery Capacity : Battery capacity in Ah. If batteries are
connected in parallel, add up their capacities. If batteries are connected in
series the capacity does not change (only the number of cells in series does).
Default Factory Settings. T he default configuration for PowerMon is to
use the integrated current shunt. The device can always be reset to the
default configuration using the PowerMonX app. To do this, connect to a
device, tap the top right corner menu, and then “Device Information”. Tap on
Factory Reset.
WARNING: When resetting to the factory defaults, all custom settings, and
timers will be erased, including the device calibration, the battery fuel
gauge internal state, and the data log.
Password lock. The device can be locked using a master/user password
scheme. Upon connecting, the app will prompt the user to enter the user
password if the device is locked. Once the correct password is entered, the
device becomes unlocked and will stay unlocked for the duration of the
connection.
The master password locks only certain functions that are critical to the
correct and safe operation of the device. The manufacturer of a custom system
using the PowerMon battery monitor can use the master password to protect
those critical areas of the configuration. The critical areas protected by the
master password can be unlocked by tapping on “Master Access Unlock” on the
Device Information page.
The following features are not available if the device is locked by the master
password: resetting the power meter/battery statistics, saving the
configuration, resetting to factory settings, zeroing or calibrating the
current reading, clearing the data log, updating the device firmware.
If the device is locked with the user password, entering the master password
instead will unlock the entire device.
Operation. PowerMon is continuously advertising its presence over
Bluetooth. PowerMonX is the preferred app to use, and it can be found on the
App Store / Play Store for both Apple and Android devices. The app allows you
to scan for PowerMon devices, connect, view the live data, view the battery
statistics, change the configuration, rename the device, configure the
password protection, visualize the logged data, and more.
Radio performance. The device contains an internal Bluetooth Low Energy
radio operating in the 2.4GHz ISM band and an internal antenna. For best
performance, the device should be installed in such a way as to offer a path
for radio waves to reach it. Metal walls or enclosures can attenuate or
completely shield the device. Installation on non-metallic surfaces is
preferred. The mobile device app displays the RSSI value (Received Signal
Strength Indication) in real-time.
Renaming the device. Renaming the device can be achieved using the top-
right menu button and taping on “Device Information”. The maximum name length
is 8 characters.
WIRING DIAGRAMS
A typical application using the internal shunt, without the relay
- The disconnect functions are not available (there is no relay).
- V2 can be used to monitor a second battery, the midpoint between two batteries in series, or the solar panel input voltage (max. 72V). Leave unconnected if not used.
- Don’t forget to wire ES1 and ES2 together
A typical application using the internal shunt and the relay
- The disconnect functions are available
- V2 can be used to monitor a second battery, the midpoint between two batteries in series, or the solar panel input voltage (max. 72V). Leave unconnected if not used.
- The charging sources are connected before the relay. This is done so they cannot be disconnected from the battery during a low voltage or other disconnect events (very important for an MPPT charge controller).
- Don’t forget to wire ES1 and ES2 together
A typical application using an external shunt and no relay
- The disconnect functions are not available (there is no relay).
- V2 can be used to monitor a second battery, the midpoint between two batteries in series, or the solar panel input voltage (max. 72V). Leave unconnected if not used.
- The sense wires from the shunt to ES1 and ES2 should be as short as possible and twisted to minimize noise
- The main fuse should be sized based on the maximum system current and the wire size
A typical application using an external shunt and the relay
- The disconnect functions are not available (there is no relay).
- V2 can be used to monitor a second battery, the midpoint between two batteries in series, or the solar panel input voltage (max. 72V). Leave unconnected if not used.
- The charging sources are connected before the relay. This is done so they cannot be disconnected from the battery during a low voltage or other disconnect events (very important for an MPPT charge controller).
- The main fuse should be sized based on the maximum system current and the wire size
A typical application of a battery isolator using an external shunt
- The disconnect functions are not available
- V1 is monitoring the starting battery voltage
- V2 is monitoring the house battery voltage
- The house battery SoC is monitored. Set the fuel gauge voltage source to V2 (see device configuration)
DIMENSIONS
Dimensions are in inches.
ORDERING
Part Number | Description |
---|---|
PowerMon | Bluetooth LE Advanced Battery Monitor / DC power meter |
Documents / Resources
|
Thornwave Labs Inc PowerMon Bluetooth Low Energy Advanced Battery Monitor DC
Power
Meter
[pdf] User Manual
PowerMon, Bluetooth Low Energy Advanced Battery Monitor DC Power Meter,
PowerMon Bluetooth Low Energy Advanced Battery Monitor DC Power Meter, Low
Energy Advanced Battery Monitor DC Power Meter, Energy Advanced Battery
Monitor DC Power Meter, Advanced Battery Monitor DC Power Meter, Battery
Monitor, Monitor, Battery Monitor DC Power Meter, Power Meter
---|---