Operating instructions with EU Declaration of Conformity According to EC Machinery Directive 2006/42/11 B
Kaitstud / Secured by https://mereneid.eu

OPERATING INSTRUCTIONS

A 1 Picture documentation of the unitNOVA FLAIR Taifun II Professional
Premium GreenTech fig 3 Picture no. 1
Front and side view of the nail dust collector with main filter elementsNOVA
FLAIR Taifun II Professional Premium GreenTech fig 4

Picture no. 2
Ready-to-install unit with main filter elements and extraction fansNOVA
FLAIR Taifun II Professional Premium GreenTech fig 5

Picture no. 3
Front view with main filter elements and dust collection tray pulled outNOVA
FLAIR Taifun II Professional Premium GreenTech fig 6 Picture no. 4
Illustration of type plate Taifun II Premium Green Tech (example illustration)

Safety instructions

A 2.1 Intended use
The nail dust collector has been built for installation under a work table or table top and has been developed exclusively for extracting dusts as they occur during work in the nail studio. Any other use beyond this, which does not comply with the accident prevention regulations of the Employer‘s Liability Insurance Association, is considered improper use. The manufacturer is  not liable for any damage resulting from this. In this case, the user must bear the risk alone. Intended use includes, among other things,  b-
serving the respective manufacturer‘s operating instructions for the system components of the nail dust collector as well as the inspection and maintenance instructions.
The system components are built and linked according to the latest state of the art and the recognised safety rules. Nevertheless, their use may result in hazards for the user or third parties or impairment of the system or other material assets.
Irrespective of the laws and regulations mentioned in these instructions, the respective valid laws and regulations must be observed and the generally recognised rules of technology must be applied.
A 2.2 Organisatorische Maßnahmen
The operating instructions for the Taifun II Premium GreenTech nail dust collector must always be available to the operating and maintenance personnel In addition to the
operating instructions, generally applicable, company-internal legal and other binding regulations for accident prevention and environmental protection must be observed and instructed.
It must be ensured that the filters are regularly cleaned and dry-cleaned according to the operating instructions. If cleaning is no longer possible, the filters must be replaced with the replacement filters specified by the manufacturer. The replaced or clogged filters must be disposed of in accordance with the Closed Sub stance Cycle and Waste Management Act. The personnel working on the nail dust collector must have read and understood the operating instructions, especially the chapter on safety instructions, before starting work.
We recommend the management to have the training confirmed by signature.
All safety and danger notices on the machine must be observed.
All safety and danger notices on the machine must be kept completely legible.
In the event of safety-relevant changes to the machine or its operating behaviour, it is imperative that the machine is shut down im- mediately, the fault rectified and the respon- sible body or person reported immediately. No changes, additions or conversions may be made to the machine that affect safety without the approval of the manufacturer of the nail dust collector. Prescribed intervals or intervals spe- cified in the operating instructions for recurring tests/inspections must be observed. This also
applies to maintenance instructions in the documentation of the component manufacturers.
A 2.3 Selection and qualification of personnel
Only instructed, mentally and physically suitable persons who are at least 16 years old may work on the machine.
Work on electrical equipment of the nail dust collector may only be carried out by a qualified electrician or by a „specially instructed person“ under the guidance and supervision of a qualified electrician in accordance with the electrotechnical regulations.
Specialists and instructed persons in this sense are service technicians/customer service of the manufacturer or trained electricians.
A 2.4 Safety instructions for normal operation In case of commercial use, the nail dust collector must be inspected at least once a year by a competent person in accordance with the fol- lowing specifications of the Emplo-yer‘s Liability Insurance Association.
BGV A3 „Electrical systems and equipment“.
In addition, the system must be checked regularly, at least once a year, for operational safety in accordance with the requirements of the Operational Safety Ordinance (BetrSichV). The inspections must be documented in accordance with the specifications.
A Safe removal of possible blockages
In the event that a foreign object enters the interior of the housing or the fan motors, proceed as follows. motors, proceed as follows:

  • Disconnect the unit from the mains voltage
  • Try to remove the foreign body from the outside
  • If the foreign object cannot be removed from the outside, the unit must be dismantled and, if necessary, opened by a trained specialist.

» Safety instructions

  • Any operation that is not in accordance with the intended use must be refrained from.
  • The nail dust collector may only be operated who are mentally and physically fit.
  • Make sure that the mains voltage corresponds to the required voltage of 230V.
  • The nail dust collector & filters must be cleaned or changed regularly according to the manufacturer‘s instructions.
  • Only the filters listed in the operating instruc tions and provided by the manufacturer may be used.
  • Appropriate measures must be taken to ensure that the nail dust collector is only used in a safe and functional condition.
  • Before each use of the nail dust collector, it must be checked for externally visible damage and defects.
  • To avoid electric shock or other hazards, never open an electrical enclosure and do not insert any objects into the enclosure.
  • The nail dust collector is protected by a built-in fuse. A defective fuse must not be bypassed or replaced with a stronger fuse.
  • Safety-relevant damage (e.g. loosened screw connections, defective protective devices, elec- trical faults, defective operating devices) must be reported to the responsible supervisor or the manufacturer. The latter must then check whether safe use is still possible.
  • Repairs may only be carried out by authorised and competent persons.
  • Before starting work, every employee must en- sure that no one is endangered by the use of the nail dust collector.
  • A damaged nail dust collector must be shut down immediately and secured against being put back into operation.

A 2.6 Notes on special hazards
A 2.6.1 Electrical energy

Only use original fuses with prescribed amperage! Make sure that the mains voltage corresponds to the required voltage of 230V. In case of malfunctions in the electrical power supply, switch off the machine immediately.
Work on electrical systems or equipment may only be carried out by a qualified electrician or by instructed persons under the direction and supervision of a qualified electrician in accordance with the electrotechnical regulations.
If inspection, maintenance, cleaning and repair work is carried out on parts of the machine, the nail dust collector must be disconnected from the circuit or de-energised by removing the power plug from the socket.
The electrical equipment of the machine must be inspected/checked regularly.
Defects, such as loose connections or scorched cables, must be rectified immediately.NOVA FLAIR Taifun II Professional Premium GreenTech fig
8 Picture no. 5
Front/side view of the nail dust collector with operating devices and mains connection
A 2.6.2 Block diagram/schematic representation of the systemNOVA FLAIR
Taifun II Professional Premium GreenTech fig 9

A 2.6.3 Noise
The machine produces only slight, barely perceptible vibrations and noise with a rating level of LAR > 58 dB(A). According to the „Noise and Vibration Occupational Health and Safety Ordinance“, in short LärmVibrationsArbSchV – these are not health hazards.
A 2.7 UVV regulations
The individual Berufsgenossen- schaften only issue accident pre- vention regulations (UVV) relevant to their area. The collection of individual accident prevention regulations published by the Federation of Institutions for Statutory Accident Insurance and Prevention (Hauptverband der gewerblichen Berufsgenossenschaften) includes all of the currently valid accident prevention regulations (UVV) issued by the industrial Berufsgenossenschaften.
Most important accident prevention regulations:
BGV A3
Electrical installations and equipment
BGV A8
Safety and health protection labelling at the workplace
GS-BIA-M02
Principles for the testing and certification of dust removing machines and devices (SBM)
GS-BIA-M06
Principles for testing filters for use in dust removing machines
VDI 3801
Operation of ventilation and air-conditioning systems
VDI 3803
Ventilation systems; constructional and technical requirements
VDI 6022
Hygienic requirements for ventilation and air-conditioning systems
LärmVibrationsArbSchV
Noise & Vibration Occupational Health & Safety Ordinance
A 2.8 Notes on the transport of the unit
To prevent foreign bodies from getting into the unit, the filters should be inserted and the filter openings closed. Also, when transporting the unit, use suitable cardboard packaging to prevent foreign bodies from getting into the nail dust collector, the filters or the motors from above.
Before reassembling the  unit,make sure that there are no foreign bodies in the unit itself or in the filters or motors. For reinstallation, the installation instructions prescribed on the following page 8 apply.
A 2.9 Notes on storage of the unit
The unit must always be stored in a dry and dust-free environment. Suitable cardboard packaging should also be used for this purpose.
If the system becomes dirty during storage, it must be cleaned thoroughly before installation and commissioning. This should be done after instruction by a specialist or an instructed person.
A 2.10 Information on decommissioning, dismantling and disposal

When taking individual system components out of operation, the respective manufacturer‘s operating instructions for the components must be consulted. If individual system components are removed from the network and the system as a whole continues to be operated, attention must be paid to securing possible danger points.
If this impairs the safety level of the system in individual areas or as a whole, the manufacturer‘s CE declaration of conformity is invalid. The responsibility for this lies with the operator.
When dismantling larger plant parts and assemblies, a hazard analysis must be carried out to determine whether any risks arise for employees as a result or in the process. A work plan must specify the work to be carried out in terms of sequence and safe working.
Nova Flair is a registered trademark of the electronic register of old appliances (ear).
Our registration number with the Foundation for Waste Electrical Equipment Register:
WEEE-Reg.-Nr. DE 22364359

INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE

NOVA FLAIR Taifun II Professional Premium GreenTech fig
11

  1. Carefully unpack the nail dust collector and first check that the black rubber seals on the edges stick properly.
  2. Place the nail dust collector on the underside of the table top and adjust it so that the cut-out for the ventilation grille is as central as possible (see sketch).
  3. Use the jigsaw etc. to make a cut-out in the centre with a diameter of Ø 160 mm.
  4. Now you can fix the nail dust collector with  suitable screws. (not included in the delivery).

Please pay attention to the length of the screws!
If anything is unclear, please contact us via the communication channels known to you. It will then be explained to you again in detail.

Instruction Manual Taifun II Premium GreenTech

Function
The nail dust collector is switched on and off via the green push button.
The speed control is used for stepless adjustment of the power. of the power.
Cleaning
Use the hand screws (knurled screws) to loosen the removable front panel and carefully pull out the activated charcoal lamella filter slowly using a loop.
For this purpose, it is best to use our additionally available dust collection t ray.
The activated charcoal lamella filters should be taken out and cleaned about 2 2-4 times per month. The remaining coarse dust is simply removed by pulling out the large dust collection tray (optionally available) and disposed of. If there is no dust collection tray, the dust must be sucked out from the inside through the large filter openings with a hoover and a narrow crevice nozzle attachment or similar.
Also clean or vacuum the lamella filter very carefully on the lower side only (not the clean air side at the top). Do not treat it wet and replace it after approx. one year.
The replacement of the filters and the frequency of cleaning can vary depending on the effort, care and customer volume.

INFORMATION ABOUT THE SYSTEM / TECHNICAL DATA

Professional nail dust collector for under-table installation

Dust collector| Type Taifun II Premium GreenTech Year of manufacture See type plate of the respective system| Nova Flair
GmbH & Co. KG
---|---|---
The above-mentioned dust nail dust collector was combined with individual machine parts from different manufacturers to form an nail dust collector.
System part ,………………………………………………Type and designations| Manufacturer
---|---
Electrical Connected loads| 230 V
50 – 60 Hz
160 W
Aluminium housing| Housing made of anodised aluminium sheet, powder-coated, dimensions W/H/D approx. 85 x 38 x 115 [cm].
Net weight| 8 kg
Switch/button| Illuminated single-pole ON-OFF push button
Fuse| 2A Inert| WeltronElektronik GmbH
Fans| 2x Radial blower type R3G146-AH23-01| ebm-papst Mulfingen GmbH & Co. KG
Filter| 2x fine dust lamella filter with an activated carbon coating and a filter surface of 3,200 [cm2] each
Maximum flow rate| 530 [m3/h] Air volume flow
Final pressure difference maximum| 420 [Pa]

EU DECLARATION OF CONFORMITY
For the product described below:
Subject of the declaration: Professional nail dust collector
Type/Model: Taifun II Premium GreenTech is hereby declared to be in conformity with the essential requirements set out in the harmonisation legislation identified below:

Document no. Title
2006/42/EG Directive 2006/42/EC of the European Parliament and of the Council

of 17 May 2006 on machinery and amending Directive 95/16/EC (recast).
2014/30/EU| Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast).
2011/65/EU| Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Electronic Equipment (recast)

The above product is compliant with the requirements of the following documents:

Reference Title Issue date

Harmonised standards for the Machinery Directives:
EN ISO 13857| Safety of machinery
Safety distances against reaching from reaching danger zones with the upper and lower limbs| 2008-03
EN 61310-1| Safety of machinery – displays,
Identification and operation. Part 1: Requirements for visible, audible and tactile signals| 2008-02
EN 61310-2| Safety of machinery – displays,  Marking and operating – Part 2: Requirements for marking| 2008-01
EN 61310-3| Safety of machinery – displays,  Marking and operating – Part 3: Requirements for the arrangement and operation of control elements (actuators)| 2008-02

Harmonised standards for the EMC Directive:

EN 55014-1 Electromagnetic compatibility – Requirements for 2006-12
EN 55014-1/A1 household appliances, electric tools and similar apparatus

2009-05
EN 55014-1/A2| Part 1: Emission| 2011-09
EN 55014-2| Electromagnetic compatibility – Requirements for| 1997-02
EN 55014-2/AC| household appliances, electric tools and similar apparatus| 1997-12
EN 55014-2/A1| Part 2: Immunity – Product family standard| 2001-12
EN 55014-2/A2| | 2008-10
EN 61000-3-2| Electromagnetic compatibility (EMC)
Part 3-2: Limits – Limits for harmonic currents (equipment input current <=16 A per conductor)| 2014-08
EN 61000-3-3| Electromagnetic compatibility (EMC)
Part 3-3: Limits – Limitation of voltage changes & variations and flicker in public low-voltage supply systems for equipment with a rated current <=16 A per conductor and not subject to a special connection condition| 2013-08

The declaration is made by:

Name, first name: Herb, Albert
Function: Managing Director/ Authorised Document Officer

The sole responsibility for drawing up this EU declaration of conformity in relation to the fulfilment of the essential requirements and the preparation of the technical documentation shall lie with the manufacturer:
Name:| Nova Flair GmbH & Co. KG
Address:| An der Ronceva 10-12 | 32312 Lübbecke | Germany
Date………01/01/2022| Company stamp and signature Managing Partner
Place………………Lübbecke| Nova Flair GmbH & Co. KG
An der Ronceva 10-12 32312 Llibbecke
Germany Tel.: 057 41 / 23 55 – 92
Fax: -94
E-Mail: info@novarlair.de
www.novaflair.de

Additional information:

This declaration applies to all specimens manufactured in accordance with the relevant production drawings – which are part of the technical documentation. Further information on compliance with the above references is given in the supporting documentation attached to the declaration of conformity. supporting documentation attached to the declaration of conformity.

Nova Flair GmbH & Co. KG
Operating Instructions with EU Declaration of Conformity
Dust Extraction Unit Taifun II Premium GreenTech
Kaitstud / Secured by https://mereneid.eu/
Nova Flair GmbH & Co. KG
An der Ronceva 10-12 | 32312 Lübbecke | Germany
January 2022
Kaitstud / Secured by https://mereneid.eu/

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals