OPERATING INSTRUCTIONS
A 1 Picture documentation of the unit Picture no. 1
Front and side view of the nail dust collector with main filter elements
Picture no. 2
Ready-to-install unit with main filter elements and extraction fans
Picture no. 3
Front view with main filter elements and dust collection tray pulled out Picture no. 4
Illustration of type plate Taifun II Premium Green Tech (example illustration)
Safety instructions
A 2.1 Intended use
The nail dust collector has been built for installation under a work table or
table top and has been developed exclusively for extracting dusts as they
occur during work in the nail studio. Any other use beyond this, which does
not comply with the accident prevention regulations of the Employer‘s
Liability Insurance Association, is considered improper use. The manufacturer
is not liable for any damage resulting from this. In this case, the user must
bear the risk alone. Intended use includes, among other things, b-
serving the respective manufacturer‘s operating instructions for the system
components of the nail dust collector as well as the inspection and
maintenance instructions.
The system components are built and linked according to the latest state of
the art and the recognised safety rules. Nevertheless, their use may result in
hazards for the user or third parties or impairment of the system or other
material assets.
Irrespective of the laws and regulations mentioned in these instructions, the
respective valid laws and regulations must be observed and the generally
recognised rules of technology must be applied.
A 2.2 Organisatorische Maßnahmen
The operating instructions for the Taifun II Premium GreenTech nail dust
collector must always be available to the operating and maintenance personnel
In addition to the
operating instructions, generally applicable, company-internal legal and other
binding regulations for accident prevention and environmental protection must
be observed and instructed.
It must be ensured that the filters are regularly cleaned and dry-cleaned
according to the operating instructions. If cleaning is no longer possible,
the filters must be replaced with the replacement filters specified by the
manufacturer. The replaced or clogged filters must be disposed of in
accordance with the Closed Sub stance Cycle and Waste Management Act. The
personnel working on the nail dust collector must have read and understood the
operating instructions, especially the chapter on safety instructions, before
starting work.
We recommend the management to have the training confirmed by signature.
All safety and danger notices on the machine must be observed.
All safety and danger notices on the machine must be kept completely legible.
In the event of safety-relevant changes to the machine or its operating
behaviour, it is imperative that the machine is shut down im- mediately, the
fault rectified and the respon- sible body or person reported immediately. No
changes, additions or conversions may be made to the machine that affect
safety without the approval of the manufacturer of the nail dust collector.
Prescribed intervals or intervals spe- cified in the operating instructions
for recurring tests/inspections must be observed. This also
applies to maintenance instructions in the documentation of the component
manufacturers.
A 2.3 Selection and qualification of personnel
Only instructed, mentally and physically suitable persons who are at least
16 years old may work on the machine.
Work on electrical equipment of the nail dust collector may only be carried
out by a qualified electrician or by a „specially instructed person“ under the
guidance and supervision of a qualified electrician in accordance with the
electrotechnical regulations.
Specialists and instructed persons in this sense are service
technicians/customer service of the manufacturer or trained electricians.
A 2.4 Safety instructions for normal operation In case of commercial use,
the nail dust collector must be inspected at least once a year by a competent
person in accordance with the fol- lowing specifications of the Emplo-yer‘s
Liability Insurance Association.
BGV A3 „Electrical systems and equipment“.
In addition, the system must be checked regularly, at least once a year, for
operational safety in accordance with the requirements of the Operational
Safety Ordinance (BetrSichV). The inspections must be documented in accordance
with the specifications.
A Safe removal of possible blockages
In the event that a foreign object enters the interior of the housing or the
fan motors, proceed as follows. motors, proceed as follows:
- Disconnect the unit from the mains voltage
- Try to remove the foreign body from the outside
- If the foreign object cannot be removed from the outside, the unit must be dismantled and, if necessary, opened by a trained specialist.
» Safety instructions
- Any operation that is not in accordance with the intended use must be refrained from.
- The nail dust collector may only be operated who are mentally and physically fit.
- Make sure that the mains voltage corresponds to the required voltage of 230V.
- The nail dust collector & filters must be cleaned or changed regularly according to the manufacturer‘s instructions.
- Only the filters listed in the operating instruc tions and provided by the manufacturer may be used.
- Appropriate measures must be taken to ensure that the nail dust collector is only used in a safe and functional condition.
- Before each use of the nail dust collector, it must be checked for externally visible damage and defects.
- To avoid electric shock or other hazards, never open an electrical enclosure and do not insert any objects into the enclosure.
- The nail dust collector is protected by a built-in fuse. A defective fuse must not be bypassed or replaced with a stronger fuse.
- Safety-relevant damage (e.g. loosened screw connections, defective protective devices, elec- trical faults, defective operating devices) must be reported to the responsible supervisor or the manufacturer. The latter must then check whether safe use is still possible.
- Repairs may only be carried out by authorised and competent persons.
- Before starting work, every employee must en- sure that no one is endangered by the use of the nail dust collector.
- A damaged nail dust collector must be shut down immediately and secured against being put back into operation.
A 2.6 Notes on special hazards
A 2.6.1 Electrical energy
Only use original fuses with prescribed amperage! Make sure that the mains
voltage corresponds to the required voltage of 230V. In case of malfunctions
in the electrical power supply, switch off the machine immediately.
Work on electrical systems or equipment may only be carried out by a qualified
electrician or by instructed persons under the direction and supervision of a
qualified electrician in accordance with the electrotechnical regulations.
If inspection, maintenance, cleaning and repair work is carried out on parts
of the machine, the nail dust collector must be disconnected from the circuit
or de-energised by removing the power plug from the socket.
The electrical equipment of the machine must be inspected/checked regularly.
Defects, such as loose connections or scorched cables, must be rectified
immediately. Picture no. 5
Front/side view of the nail dust collector with operating devices and mains
connection
A 2.6.2 Block diagram/schematic representation of the system
A 2.6.3 Noise
The machine produces only slight, barely perceptible vibrations and noise with
a rating level of LAR > 58 dB(A). According to the „Noise and Vibration
Occupational Health and Safety Ordinance“, in short LärmVibrationsArbSchV –
these are not health hazards.
A 2.7 UVV regulations
The individual Berufsgenossen- schaften only issue accident pre- vention
regulations (UVV) relevant to their area. The collection of individual
accident prevention regulations published by the Federation of Institutions
for Statutory Accident Insurance and Prevention (Hauptverband der gewerblichen
Berufsgenossenschaften) includes all of the currently valid accident
prevention regulations (UVV) issued by the industrial Berufsgenossenschaften.
Most important accident prevention regulations:
BGV A3
Electrical installations and equipment
BGV A8
Safety and health protection labelling at the workplace
GS-BIA-M02
Principles for the testing and certification of dust removing machines and
devices (SBM)
GS-BIA-M06
Principles for testing filters for use in dust removing machines
VDI 3801
Operation of ventilation and air-conditioning systems
VDI 3803
Ventilation systems; constructional and technical requirements
VDI 6022
Hygienic requirements for ventilation and air-conditioning systems
LärmVibrationsArbSchV
Noise & Vibration Occupational Health & Safety Ordinance
A 2.8 Notes on the transport of the unit
To prevent foreign bodies from getting into the unit, the filters should be
inserted and the filter openings closed. Also, when transporting the unit, use
suitable cardboard packaging to prevent foreign bodies from getting into the
nail dust collector, the filters or the motors from above.
Before reassembling the unit,make sure that there are no foreign bodies in
the unit itself or in the filters or motors. For reinstallation, the
installation instructions prescribed on the following page 8 apply.
A 2.9 Notes on storage of the unit
The unit must always be stored in a dry and dust-free environment. Suitable
cardboard packaging should also be used for this purpose.
If the system becomes dirty during storage, it must be cleaned thoroughly
before installation and commissioning. This should be done after instruction
by a specialist or an instructed person.
A 2.10 Information on decommissioning, dismantling and disposal
When taking individual system components out of operation, the respective
manufacturer‘s operating instructions for the components must be consulted. If
individual system components are removed from the network and the system as a
whole continues to be operated, attention must be paid to securing possible
danger points.
If this impairs the safety level of the system in individual areas or as a
whole, the manufacturer‘s CE declaration of conformity is invalid. The
responsibility for this lies with the operator.
When dismantling larger plant parts and assemblies, a hazard analysis must be
carried out to determine whether any risks arise for employees as a result or
in the process. A work plan must specify the work to be carried out in terms
of sequence and safe working.
Nova Flair is a registered trademark of the electronic register of old
appliances (ear).
Our registration number with the Foundation for Waste Electrical Equipment
Register:
WEEE-Reg.-Nr. DE 22364359
INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE
- Carefully unpack the nail dust collector and first check that the black rubber seals on the edges stick properly.
- Place the nail dust collector on the underside of the table top and adjust it so that the cut-out for the ventilation grille is as central as possible (see sketch).
- Use the jigsaw etc. to make a cut-out in the centre with a diameter of Ø 160 mm.
- Now you can fix the nail dust collector with suitable screws. (not included in the delivery).
Please pay attention to the length of the screws!
If anything is unclear, please contact us via the communication channels
known to you. It will then be explained to you again in detail.
Instruction Manual Taifun II Premium GreenTech
Function
The nail dust collector is switched on and off via the green push button.
The speed control is used for stepless adjustment of the power. of the power.
Cleaning
Use the hand screws (knurled screws) to loosen the removable front panel and
carefully pull out the activated charcoal lamella filter slowly using a loop.
For this purpose, it is best to use our additionally available dust
collection t ray.
The activated charcoal lamella filters should be taken out and cleaned about 2
2-4 times per month. The remaining coarse dust is simply removed by pulling
out the large dust collection tray (optionally available) and disposed of. If
there is no dust collection tray, the dust must be sucked out from the inside
through the large filter openings with a hoover and a narrow crevice nozzle
attachment or similar.
Also clean or vacuum the lamella filter very carefully on the lower side only
(not the clean air side at the top). Do not treat it wet and replace it after
approx. one year.
The replacement of the filters and the frequency of cleaning can vary
depending on the effort, care and customer volume.
INFORMATION ABOUT THE SYSTEM / TECHNICAL DATA
Professional nail dust collector for under-table installation
Dust collector| Type Taifun II Premium GreenTech Year of manufacture See type
plate of the respective system| Nova Flair
GmbH & Co. KG
---|---|---
The above-mentioned dust nail dust collector was combined with individual
machine parts from different manufacturers to form an nail dust collector.
System part ,………………………………………………Type and designations| Manufacturer
---|---
Electrical Connected loads| 230 V
50 – 60 Hz
160 W
Aluminium housing| Housing made of anodised aluminium sheet, powder-coated,
dimensions W/H/D approx. 85 x 38 x 115 [cm].
Net weight| 8 kg
Switch/button| Illuminated single-pole ON-OFF push button
Fuse| 2A Inert| WeltronElektronik GmbH
Fans| 2x Radial blower type R3G146-AH23-01| ebm-papst Mulfingen GmbH & Co. KG
Filter| 2x fine dust lamella filter with an activated carbon coating and a
filter surface of 3,200 [cm2] each
Maximum flow rate| 530 [m3/h] Air volume flow
Final pressure difference maximum| 420 [Pa]
EU DECLARATION OF CONFORMITY
For the product described below:
Subject of the declaration: Professional nail dust collector
Type/Model: Taifun II Premium GreenTech is hereby declared to be in conformity
with the essential requirements set out in the harmonisation legislation
identified below:
Document no. | Title |
---|---|
2006/42/EG | Directive 2006/42/EC of the European Parliament and of the Council |
of 17 May 2006 on machinery and amending Directive 95/16/EC (recast).
2014/30/EU| Directive 2014/30/EU of the European Parliament and of the Council
of 26 February 2014 on the harmonisation of the laws of the Member States
relating to electromagnetic compatibility (recast).
2011/65/EU| Directive 2011/65/EU of the European Parliament and of the Council
of 8 June 2011 on the restriction of the use of certain hazardous substances
in electrical and electronic equipment Electronic Equipment (recast)
The above product is compliant with the requirements of the following documents:
Reference | Title | Issue date |
---|
Harmonised standards for the Machinery Directives:
EN ISO 13857| Safety of machinery
Safety distances against reaching from reaching danger zones with the upper
and lower limbs| 2008-03
EN 61310-1| Safety of machinery – displays,
Identification and operation. Part 1: Requirements for visible, audible and
tactile signals| 2008-02
EN 61310-2| Safety of machinery – displays, Marking and operating – Part 2:
Requirements for marking| 2008-01
EN 61310-3| Safety of machinery – displays, Marking and operating – Part 3:
Requirements for the arrangement and operation of control elements
(actuators)| 2008-02
Harmonised standards for the EMC Directive:
EN 55014-1 | Electromagnetic compatibility – Requirements for | 2006-12 |
---|---|---|
EN 55014-1/A1 | household appliances, electric tools and similar apparatus |
2009-05
EN 55014-1/A2| Part 1: Emission| 2011-09
EN 55014-2| Electromagnetic compatibility – Requirements for| 1997-02
EN 55014-2/AC| household appliances, electric tools and similar apparatus|
1997-12
EN 55014-2/A1| Part 2: Immunity – Product family standard| 2001-12
EN 55014-2/A2| | 2008-10
EN 61000-3-2| Electromagnetic compatibility (EMC)
Part 3-2: Limits – Limits for harmonic currents (equipment input current <=16
A per conductor)| 2014-08
EN 61000-3-3| Electromagnetic compatibility (EMC)
Part 3-3: Limits – Limitation of voltage changes & variations and flicker in
public low-voltage supply systems for equipment with a rated current <=16 A
per conductor and not subject to a special connection condition| 2013-08
The declaration is made by:
Name, first name: | Herb, Albert |
---|---|
Function: | Managing Director/ Authorised Document Officer |
The sole responsibility for drawing up this EU declaration of conformity in
relation to the fulfilment of the essential requirements and the preparation
of the technical documentation shall lie with the manufacturer:
Name:| Nova Flair GmbH & Co. KG
Address:| An der Ronceva 10-12 | 32312 Lübbecke | Germany
Date………01/01/2022| Company stamp and signature Managing Partner
Place………………Lübbecke| Nova Flair GmbH & Co. KG
An der Ronceva 10-12 32312 Llibbecke
Germany Tel.: 057 41 / 23 55 – 92
Fax: -94
E-Mail: info@novarlair.de
www.novaflair.de
Additional information:
This declaration applies to all specimens manufactured in accordance with the relevant production drawings – which are part of the technical documentation. Further information on compliance with the above references is given in the supporting documentation attached to the declaration of conformity. supporting documentation attached to the declaration of conformity.
Nova Flair GmbH & Co. KG
Operating Instructions with EU Declaration of Conformity
Dust Extraction Unit Taifun II Premium GreenTech
Kaitstud / Secured by https://mereneid.eu/
Nova Flair GmbH & Co. KG
An der Ronceva 10-12 | 32312 Lübbecke | Germany
January 2022
Kaitstud / Secured by https://mereneid.eu/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>