SmartPower SBP450U Plus-T SBP Plus Series Uninterruptible Power Supply User Guide

October 27, 2023
SmartPower

SmartPower SBP450U Plus-T SBP Plus Series Uninterruptible Power Supply

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important instructions for models SBP450UPlus-T, SBP650UPlus-T, SBP800UPlus-T, SBP1000UPlus-T, and SBP1500U Plus-T that should be followed during the installation and maintenance of the UPS and batteries.
Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

Safety Cautions!

  • CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)
  • CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat-emitting appliances such as space heaters or furnaces.
  • CAUTION! Do not attach non computer related items such as medical — , equipment life-support equipment, microwave ovens, or vacuum cleaners to UPS. ,
  • CAUTION! Do not plug the UPS input into its own output.
  • CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
  • CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
  • CAUTION! Do not attach a power strip or surge suppressor to the UPS.
  • CAUTION! Internal battery voltage is 12Vdc Sealed lead acid 6-cell battery. . , -,
  • CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
  • CAUTION! When replacing the batteries, use the same number and type of batteries.
  • CAUTION! Do not dispose of batteries in a fire The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
  • CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
  • CAUTION! A battery can present a risk of electric shock and high short circuit current.
    The following precaution should be observed before replacing batteries:
  1. Remove watches, rings, or other metal objects.
  2. Use tools with insulated handles.
  3. Wear rubber gloves and boots.
  4. Do not lay tools or metal parts on top of batteries.
  5. Disconnect the charging source prior to connecting or disconnecting the batteries terminal.
    • When replacing batteries, replace them with the same number of sealed lead-acid batteries.

System Description

  1. LCD Display
    The LCD will display the UPS status including input voltage, output voltage, runtime, percentage of load and battery etc.

  2. Power On/Off Switch
    Press the power switch to turn the UPS ON or OFF.
    Press the power switch 2 times to disable and enable the alarm beeping sound.

  3. Led Indicators
    This LED is illuminated when the UPS is ON

  4. USB Port
    This port allows connection and communication from the USB port on the computer to the UPS.
    The UPS communicates its status to the Power Master software.

  5. Communication Protection Ports
    Communication protection ports will protect any standard modem, fax, telephone line, or network cable.

  6. Input Circuit Breaker
    The circuit breaker provides overload protection.

  7. Input Power Cord
    Connect to utility power.

  8. Battery Backup & Power Conditioning-Protected Outlets
    Provides battery backup and surge protection. They ensure power is provided to connected equipment over a period of time during a power failure.

Installation and Operation

UNPACKING
Inspect the UPS upon receipt. The box should contain the following:

  1. UPS
  2. User Manual

OVERVIEW
The SBP Plus provides automatic voltage regulation for inconsistent utility power and battery backup during power outages The SBP Plus ensures , . consistent power to your computer system and its included software will automatically save your open files and shutdown your computer system during a utility power loss.

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

  1. Ensure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit s rated capacity. If rated unit capacities are exceeded, ‘ an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
  2. There are many factors that can affect the amount of power that your computer system will require. For optimal system performance keep the attached load below 80% of the UPS s rated capacity.

HARDWARE INSTALLATION GUIDE

  1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, plug the UPS into an AC outlet. The unit will charge in both the on and off positions.
  2. With the UPS turned off and unplugged, connect the computer, monitor, and any equipment into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
  3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc.) Avoid using extension cords.
  4. To turn the UPS on, press the power button for 1 second until the LCD screen turns on. With the LCD screen turned on, press and hold the power button for 3-5 seconds until the OUTPUT is displayed.SmartPower-SBP450U-Plus-T-SBP-Plus-Series-Uninterruptible-Power-Supply-Fig-04
  5. If an overload is detected, an audible alarm will sound and the UPS will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker is depressed and then turn the UPS on.
  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery life.

Computer Connection
Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices).

SmartPower-SBP450U-Plus-T-SBP-Plus-Series-Uninterruptible-Power-Supply-
Fig-05

Modem/Phone line Connection
Plug incoming internet line into the “In” socket at the back of the UPS.
Use one more Internet line cable and plug one end of the Internet line cable to the “Out” socket at the back of the UPS. Plug the other end to the modem input socket as shown.

SmartPower-SBP450U-Plus-T-SBP-Plus-Series-Uninterruptible-Power-Supply-
Fig-06

UPS TBF™ Models

  1. Turn off and un-plug all devices.
  2. Plug UPS unit into grounded wall outlet.
  3. Place the UTBF where monitoring lights can be observed.

UTBF INDICATORS:
Green light only – It confirms properly connected equipment is fully protected.
Green and Red light – Reverse polarity or loss of ground at the wall outlet.
Call your electrician to correct the problem.
Green light off – Power failure or UTBF fault. Contact customer service.

REPLACING THE BATTERY (1000VA/1500VA only)

Replacement of batteries located in an OPERATOR ACCESS AREA

  1. When replacing batteries, replace with the same number of the battery.
  2. CAUTION! Risk of Energy Hazard! Before replacing batteries, remove conductive jewelry such as chains, wristwatches, and rings. High energy conducted through these materials could cause severe burns.
  3. CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
  4. CAUTION! Do not open or mutilate batteries. Released material is harmful to CAUTION! the skin and eyes It may be toxic. .
  5. CAUTION! A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries:
  6. Remove watches rings, or other metal objects.
  7. Use tools with insulated handles.

CAUTION – RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS.

BATTERY REPLACEMENT PROCEDURE
  1. Turn off and unplug all connected equipment.
  2. Turn the UPS off and unplug it from the AC power source.
  3. Turn the UPS on its side.
  4. Remove the screws on the bottom of the front panel and lay aside.
  5. Remove the front panel of the UPS: pull and lift it.
  6. Take out the battery compartment covert.
  7. Disconnect the battery wires from the battery.
  8. Remove the battery from the compartment.
  9. Put the battery back into the compartment.
  10. Install the replacement battery by connecting the red wire (+) and black wire (-) to the same color connectors from the battery pack.
  11. Take in the battery compartment cover.
  12. Fit the front panel on and tighten the retaining screws.
  13. Recharge the UPS for 8-16 hours to fully charge the battery.

SmartPower-SBP450U-Plus-T-SBP-Plus-Series-Uninterruptible-Power-Supply-
Fig-08

REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by local regulations.

For battery replacement instructions for models 450 to 800 refer to our support page at https://smartpowersystems.com/support-2/battery-replacement/

Free Software Download

Smart Power Master management software provides a user-friendly interface for your power systems.
The graphic user-interface is intuitive and displays essential power information at a glance.
Please follow procedure below to install the software.

Installation procedure:

  1. Download Smart Power Master from the website: https://www.smartpowersystems.com/downloads/Smartpowermaster/pm106-setup.exe
  2. Double-click the file and follow the installation steps.

Smart Power Master software consists of two different modules Agent and Client. The agent monitors and configures the UPS through the USB or serial connection, logs UPS status and power events, and generates actions in response to events. The client establishes communication with the Agent, UPS RMCARD, PDU or ATS and generates actions according to notifications from the UPS/PDU/ATS when a power event occurs.

Agent

  • Unattended shutdown in response to various power conditions.
  • User notification of power conditions.
  • Flexible configuration of actions for each event and notifications via E-mail, Instant Message, and SMS.
  • Run command files for custom applications.
  • Historical log of events and power conditions.
  • Detailed load management for all powered equipment.
  • Scheduled shutdown and restart.
  • Status monitoring of the UPS and utility power.
  • UPS configuration.
  • Quick view system summary.

Client
The Client provides unattended shutdown for the hosted computer following a
notification from the UPS/PDU/ATS. The Client also provides the following functions:

  • Unattended shutdown in response to various power conditions.
  • User notification of power conditions.
  • Flexible configuration of actions for each specific event and notifications via E-mail, Instant Message, and SMS.
  • Historical logs of power events.
  • Quick view system summary.

Troubleshooting

Symptom Possible Cause Solution
The UPS does not perform expected runtime. Batteries are not fully charged

Recharge the battery by leaving the UPS plugged in.
battery is slightly worn out| Contact technical support


The UPS will not turn on.

| The on/off switch is designed to prevent damage by rapidly turning it off and on.| Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The UPS is not connected to an AC outlet.| The unit must be connected to a 120VAC 50/60Hz outlet.
The battery is worn out| Contact technical support
Mechanical problem.| Contact technical support
Outlets do not provide power to equipment| Circuit breaker is tripped due to overload.| Turn the UPS off and unplug

at least one piece of connected equipment. Unplug the power cord of the UPS then press the circuit breaker knob.

Batteries are discharged| Allow the unit to recharge for at least 4 hours.
Unit has been damaged by a surge or spike| Contact technical support
2. Power cord is loose.| 2. Reconnect the power cord
Smart Power Master is inactive| The serial/USB cable is not connected| Connect the serial/USB cable to the UPS unit and open serial port on the back of the computer. You must use the cable that came with the unit.
The unit is not providing battery power| Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. this should reset the unit.

If abnormal situations occur that are not listed above, please call customer service immediately.

Specifications

MODEL| SBP450UPLUS- T| SBP650UPLUS- T| SBP800UPLUS- T| SBP1000UPLUS- T| SBP1500UPLUS- T
---|---|---|---|---|---
Rated capacity (VA/W)| 450 / 270| 650 / 390| 800 / 450| 1000 / 600| 1440 / 900
Rated power factor| 0.6
INPUT|
Voltage| 100-120VAC
Input voltage range| 82-150VAC
Input frequency range| 50/60Hz± 3Hz
Plug type| NEMA 5-15P
Plug style| Straight
OUTPUT|
On battery waveform| Simulated sine wave
On battery voltage| 100-120VAC ±10%
Automatic voltage regulation (AVR)| Double boost / Single buck
Automatic voltage regulation (Line mode)| ****

Boost:1.06, Boost 2: 1.24, Buck: 0.85

On battery frequency| 50/60Hz ±1Hz
Outlets – Total

(Bat. & Surge Protected)

| 6| 8
Outlet type| NEMA 5-15R
Transfer time| 4ms TYP
Protection| Overload, short circuit, over discharge and over charge
Overload-Line mode| >(110%±10%) fault after alarm 1 min, >(120%±10%) fault immediately
Overload-Batt mode| >(110%±10%) fault after alarm 1 min, >(120%±10%) fault immediately
PROTECTION|
Surge protection| 1710 Joules
Lowest Pass through Voltage| <10V Normal Mode <0.5V Common Mode
BATTERY|
Battery voltage| 12V| 24V
Battery type| (1) SP011.5| (1) SP012| (1) SP013| (2) SP012| (2) SP013
Runtime at half load (min)| 13| 8| 10| 11| 9
Charger current| 1A
Typical recharge time| 4 hours to 90% capacity
INTERFACE|
Display| LCD
**** Alarm| Battery mode: sounding every 30 seconds Low battery: sounding every 2 seconds Overload: sounding every 0.5 seconds Fault: Continuous sounding
COMMUNICATION|
HID-compliant USB port| Yes
TVSS| Yes
PHYSICAL|
Form factor| Tower
Dimensions (WxHxD) (in/mm)| 3.77 x 5.43 x 11.25 / 96 x 138 x 286| 5.82 x 7 x 11.73 / 148 x 178 x 298
Weight (lbs/kg)| 9.1 / 4.15| 10.35 / 4.69| 11.20 / 5.08| 19.22 / 8.72| 21.78 / 9.88
ENVIRONMENT|
Temperature & humidity| 0°C to +40°F, 0 to 90% relative humidity (non- condensing)
Noise level| Less than 40dB| Less than 45dB
REGULATION|
Energy saving| Green Energy function
Safety| cTUV-us
Conduction| FCC part-15 Class B| FCC part-15 Class A
Radiation| FCC part-15 Class B| FCC part-15 Class A
Transportation| Drop: ISTA 1A, Vibration: Internal standard
External protection| IP20 (static)

All trade names are registered trademarks of the respective manufacturers listed.
Specifications and features are subject to change without notice.

Definitions for illuminated LCD indicators

LCD Indication

| Line mode

UPS is running from an input line power source.

| | Battery Mode

UPS is running on battery mode due to power failure or severe input voltage fluctuation .

---|---|---|---
|

Fault

UPS detected a fault

| | Mute/Silent

Press the power switch 2 times to disable and enable the alarm beeping sound.

| Mute function only for Sounding every 30 seconds on battery mode.
| Batt mode: battery capacity Line mode:

1. Battery charging: cycle lighting

2. Battery fully charged: lighting

3. Line mode without charger: battery capacity

| | Load Capacity

Reports load-level of the UPS supported outlets.

Line mode & BATT. Mode

| |
---|---|---
Initial| AC INPUT(Voltage) V| | OUTPUT(Voltage) V|

LIMITED PRODUCT WARRANTY
We warrant this product to be free from defects in material and workmanship for 2 years. The battery has a 2 year warranty. If a product proves to be defective in material or workmanship during the warranty period, we will at our sole option repair or replace the product with a like product. Visit our website for details – www.smartpowersystems.com

CONNECTED EQUIPMENT PROTECTION POLICY
If the Smart Power Systems equipment fails and this failure causes the surges to pass through and damage the connected equipment, Smart Power Systems will pay for the repair or replacement of the connected equipment up to $25,000 in accordance to the Connected Equipment Protection Policy. Visit our website for details – https://www.smartpowersystems.com/downloads/archives/030714-SPS-CEPP.pdf

IMPORTANT
If for any reason you need to return the unit to the manufacturer, you should obtain an RMA (Return Material Authorization) number before returning the unit. To request an RMA number please call 1-800-772-7633 or visit the website at https://www.smartpowersystems.com/rma.html

FCC Compliance Statement

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) : this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the , instructions may cause harmful interference to radio communications However, , . there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which , can be determined by turning the equipment off and on the user is encouraged to try , to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Important: Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ‘ .
Canadian Compliance
CAN ICES-3 (B)/NMB-3(B)