VIAIR 330C-HG 200PSI Compressor Kit
IMPORTANT SAFETY INSTRUCTIONS
CAUTION – To reduce risk of electrical shock or electrocution:
- Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
- Do not use this product in an area where it can fall or be pulled into water or other liquids.
- Do not reach for this product if it has fallen into liquid.
- Use this compressor with 12-volt or 24-volt DC systems only.
- This product should not be left unattended during use.
WARNING – To prevent injuries:
- Never allow children to operate this compressor. Close supervision is necessary when this compressor is being used near children.
- This compressor will become very hot during and immediately after use. Do not touch any part of this compressor with bare hands other than the ON/OFF switch during and immediately after use.
- Do not use this product near flames or explosive materials or where aerosol products are being used.
- Do not operate this product where oxygen is being administered.
- Do not pump anything other than atmospheric air.
- Never use this product while sleepy or drowsy.
- Do not use any tools or attachments without first determining maximum air pressure for that tool or attachment.
- Never point any air nozzle or air sprayer toward another person or any part of the body.
- This air compressor is equipped with an Automatic Reset Thermal Protector, and can automatically restart after the thermal protector resets. Always cut off power source when thermal protector becomes activated.
- Wear safety glasses or goggles when operating this product.
- Use only in well ventilated areas.
INSTALLATION
Please read and follow the Installation Instructions carefully to avoid injury
or damage to the compressor and your vehicle.
Each air compressor has been carefully produced and packaged. Before
installation, please familiarize yourself with Installation Parts List (Fig.
- of this manual.
Guidelines for Selecting Mounting Location:
The selection of proper mounting location for your air compressor will help
ensure a long and trouble free compressor service life. Please note the
following guidelines:
-
Select a FLAT, UPRIGHT AND SECURE location where the compressor can be mounted.
-
To maximize air compressor performance, locate compressor as CLOSE TO THE BATTERY as possible so that length of positive lead wire required is at a minimum.
-
Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES.
The cooler the ambient temperature, the less chance the compressor will overheat. -
This compressor is moisture & splash resistant, but NOT WATERPROOF. Do not mount compressor in locations where the unit is likely to come in contact with water.
-
For compressors with remote filter mounting, select compressor’s mounting location where air line can be routed from compressor air inlet to remote inlet air filter. Make sure Remote Inlet Air Filters are located in dry locations, away from water sources.
-
Select compressor’s mounting location where the leader hose bracket can be mounted to secure the stainless steel braided leader hose.
-
If it is necessary to mount the air compressor further away from the battery, such as inside your vehicle or in the bed of your pickup, use a larger gauge positive lead wire for remote installation.
-
Do not mount compressor near areas where flammable liquids are stored.
-
Use thread sealant for proper fitting installation. Thread tape is not recommended.
Properly sealed, recommended torque is 12 to 15 ft. lbs
MOUNTING AND WIRING
- Disconnect ground cable from 12- or 24-volt power source.
- Temporarily position the air compressor in the location where it will be mounted.
- Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed.
- Mount air compressor with the four sets of bolts, nuts, washers, and locking washers provided.(See Mounting Instructions) Use of thread sealant is recommended.
- This air compressor comes with a Heavy Duty Heat Resistant Stainless Steel Leader Hose. The leader hose is designed to prolong the life of your air line. Follow the direction on the leader hose packaging for installation.
- Select proper location to mount leader hose with hose bracket provided. Avoid locations where leader hose may become tangled with wires and other hoses.
- To mount hose bracket, drill hole with 3/16″ drill bit and push the self–anchoring hose bracket pin into the drilled hole. Route leader hose through hose bracket and secure hose by pressing bracket clamp into locked position.
- To remove hose from the hose bracket, simply press down on the hose clamp release tab to release bracket clamp.
- Connect compressor’s positive lead wire to one of the leads of your pressure switch.
- Make sure that your compressor setup is properly fused. For appropriate fuse size, refer to amp draw of compressor in the specifications section of this manual.
- Always locate fuse as close as possible to power source.
- Before connecting to power source, re-check to make sure that all connections are made properly.
- Connect and test compressor system by running the compressor for a short time to build up pressure in your air tank.
- Once air pressure reaches preset cut out pressure of your pressure switch, the compressor will shut off. Inspect all air line connections for leaks with soap and water solution. If a leak is detected, the air line may not be cut squarely or pushed all the way in. Fix leaking connections as needed.
(Fig. 1) 330C-HG 200PSI 12V / 330C-HG 200PSI 24V Compressor Installation Parts List:
- A. Hose Bracket (1pc)
- B. Mounting Bolts (4pcs)
- C. Flat Washers (8pcs)
- D. Locking Washer (4pcs)
- E. Nuts (4pcs)
- F. 1/4″ NPT F x 3/8″ Barbed Fitting (1pc)
- G. 1/4″ NPT M x 3/8″ Barbed Fitting (1pc)
- H. Air Line Clips (3pcs)
- I. Screws (3pcs)
- J. Remote Inlet Air Filter with Filter Element (1pc)
- K. 3/8″ Airline
- L. PTFE Lined Leader Hose (with separate JIC / NPT fittings & check valve)
(Fig. 2) Compressor Mounting Hardware
- B. Mounting Bolt
- C. Flat Washer
- D. Locking Washer
- E. Nut
- K. Vibration Isolator
(Fig. 3) Leader Hose Bracket
- A. Hose Clamp
- M. Clamp Release Tab
- N. Self-Anchoring Pin
OPERATING INSTRUCTIONS
- IMPORTANT: Always operate the compressor at or below the MAXIMUM PRESSURE RATING of the compressor. Please refer to Application & Specifications Sections of this manual for details.
- Always observe the MAXIMUM DUTY CYCLE of the air compressor. Refer to Compressor Applications and Specifications Sections of this manual for details. Operation exceeding maximum pressure ratings and/or duty cycle will result in damage to the air compressor.
- Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR. This feature is designed to protect the air compressor from overheating and causing permanent damage to your air compressor. The thermal overload protector will automatically cut power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use.
- Should at any time during use, your air compressor automatically shuts off; do not attempt to restart the air compressor. Turn off power and allow unit to cool for about 30 minutes. This will allow the Thermal Overload Protector to reset so you can safely resume use of the air compressor.
- To prevent discharge of battery (power source), always supply charging voltage to enhance performance. (12-volt charging voltage up to 13.8 volts & 24-volt charging voltage up to 28 volts).
- Only operate compressor in well ventilated areas.
- The use of a relay is strongly recommended for installation of this compressor. (40-amp relay value or higher).
MAINTENANCE & REPAIRS
-
Periodically check all electrical and fittings connections. Clean and tighten as needed.
-
Periodically check all mounting screws. Tighten as needed.
-
Replace air filter element periodically. Replacement frequency depends on operating frequency and operating environment. For frequent use in dusty environment, we recommend that you replace air filter element at least once a month.
-
Regularly clean dust and dirt from compressor cooling fins and motor housing.
-
Your air compressor is equipped with a permanently lubricated, maintenance free motor.
Never try to lubricate the compressor. -
All repairs should be performed by Manufacturer or Manufacturer’s Authorized Service Agent only.
CAUTION:
Never touch the air compressor or fittings connected to the air compressor
with bare hands during or immediately after use. The leader hose and fittings
connected to leader hose will become very HOT during and after use. If
necessary, wear heat resistant gloves to handle fittings, air line, and
leader hose.
SPECIFICATIONS
Part No. 33035 / 330C-HG-200PSI 12V Compressor Kit (CE Spec.)
- Motor Voltage: 12 Volts
- Max. Current Consumption: 14 Amps
- Recommended Fuse: 20 Amps
- Motor Type: Permanent Magnetic
- Horsepower: 1/4
- Max. Working Pressure: 200 PSI
- Max. Duty Cycle (@ 72°F & 100 PSI): 100%
- Minutes On/Off (@ 72°F & 200 PSI): 50%
- Max. Restart Pressure: 200 PSI
- Max. Ambient Temperature: 158°F
- Min. Ambient Temperature: -40°F
- Auto. Reset Thermal Protection: Yes
- Dimensions: 9″L x 4″W x 6.75H”
- Net Weight: 8.25 Lbs.
Part No. 33038 / 330C-HG 200PSI 24V Compressor Kit (CE Spec.)
- Motor Voltage: 24 Volts
- Max. Current Consumption: 8 Amps
- Recommended Fuse: 15 Amps
- Motor Type: Permanent Magnetic
- Horsepower: 1/4
- Max. Working Pressure: 200 PSI
- Max. Duty Cycle (@ 72°F & 100 PSI): 100%
- Minutes On/Off (@ 72°F & 200 PSI): 50%
- Max. Restart Pressure: 200 PSI
- Max. Ambient Temperature: 158°F
- Min. Ambient Temperature: -40°F
- Auto. Reset Thermal Protection: Yes
- Dimensions: 9″L x 4″W x 6.75H”
- Net Weight: 8.25 Lbs.
330C-HG – 200PSI COMPRESSOR KIT
COMPRESSOR APPLICATION GUIDE
To ensure that you get the highest level of satisfaction from your
compressor’s performance, refer to information below:
VIAIR COMPRESSOR REFERENCE CHART
COMPRESSOR SERIES MAX. WORKING DUTY CYCLE
- PRESSURE (100 PSI @ 72°F)
- 090 SERIES 120 PSI 9%
- 092 SERIES 120 PSI 9%
- 095 SERIES 120 PSI 9%
- 097 SERIES 130 PSI 10%
- 098 SERIES 130 PSI 10%
- 100 SERIES 130 PSI 15%
- 250 IG SERIES 150 PSI 100%
- 275 SERIES 150 PSI 25%
- 280 SERIES 150 PSI 30%
- 325 SERIES 150 PSI 33%
- 330 IG SERIES 150 PSI 100%
- 330 IG SERIES-200PSI 200 PSI 100% @100 PSI
- 50% @200 PSI
- 350 SERIES 150 PSI 100%
- 380 SERIES 200 PSI 100%
- 55% @200 PSI
- 400 SERIES 150 PSI 33%
- 420 SERIES 150 PSI 33%
- 425 SERIES 175 PSI 33% @175 PSI
- 50%
- 444 SERIES 200 PSI 100%
- 50% @200 PSI
- 450 SERIES 150 PSI 100%
- 450 IG SERIES 150 PSI 100%
- 460 SERIES 150 PSI 100%
- 480 SERIES 200 PSI 100%
- 50% @200 PSI
- 485 SERIES 200 PSI 100%
- 100% @200 PSI
ABOUT COMPRESSOR DUTY CYCLE:
Duty cycle refers to the amount of time a compressor can be operated in a
given time period at 100 PSI, and a standard ambient temperature of 72° F. It
is commonly expressed in percentage format: Compressor on time ÷ (on time +
off time) = Duty Cycle %.
ONE-HOUR DUTY CYCLE MINUTES ON / (100 PSI @ 72°F) MINUTES OFF
- 9% 5 Min. On / 55 Min. Off
- 10% 6 Min. On / 54 Min. Off
- 15% 9 Min. On / 51 Min. Off
- 20% 12 Min. On / 48 Min. Off
- 25% 15 Min. On / 45 Min. Off
- 30% 18 Min. On / 42 Min. Off
- 33% 20 Min. On / 40 Min. Off
- 50% 30 Min. On / 30 Min. Off
- 100% 1 Hour Run Time
NOTE: All compressors, regardless of rated duty cycle, require sufficient rest time in between cycles to allow for partial or complete heat dissipation. Heat dissipation rates may vary depending on ambient temperatures and operating conditions.
ABOUT RATED WORKING PRESSURE:
To ensure trouble free service life of your compressor, always operate
compressor within rated working pressure of the compressor. Never use a
pressure switch with a higher cut-off pressure than compressor’s rated working
pressure.
TROUBLESHOOTING GUIDE
Tank pressure drops when
compressor (s) shut off
| 1. Loose drain cock
2. Check valve leaking
3. Loose connections
| 1. Tighten drain cock
2. Replace check valve or compressor(s)
3. Check all connections with soap and water solution and tighten
---|---|---
Compressor runs continuously and air flow lower than normal| 1. Excessive air
usage
2. Loose connections
3. Worn piston ring or inlet valve.
4. Clogged air filter element
| 1. Decrease air usage
2. Check all connections with soap and water solution and tighten.
3. Repair or replace compressor
4. Replace air filter element
Compressor runs continuously causing safety valve (if equipped) to open| 1. Bad pressure switch
2. Defective safety valve
| 1. Replace pressure switch
2. Replace safety valve
Excessive moisture in discharge| 1. Excessive water in air tank
2. High humidity
| 1. Drain tank, tilt tank to drain. Drain tank more frequently
2. Move compressor to area with less humidity, or use air line filter.
Compressor will not run| 1. No power, or power switch
in OFF position
2. Blown fuse
3. Motor overheats
4. Faulty pressure switch.
| 1. Make sure compressor
switch is ON
2. Disconnect compressors from power source, replace fuse. (Refer to Specifications section for correct fuse amperage.)
3. Let compressors cool off for about 30 Minutes to allow thermal overload switch reset.
4. Replace pressure switch
Thermal overload protector cuts out repeatedly| 1. Lack of proper ventilation or ambient temperature too high
2. Compressor valves failed
| 1. Move compressor to well ventilated area, or area with lower ambient temperature
2. Repair or replace compressor
Excessive knocking or rattling| 1. Loose mounting bolts
2. Worn bearing on eccentric or
motor shaft
3. Cylinder or piston ring is worn
| 1. Tighten mounting bolts
2. Repair or replace compressor
3. Repair or replace compressor
AMERICAN WIRE GAUGE GUIDE 12-VOLT:
Amp Draw
| Length of wire from battery to compressor (in feet)
---|---
5| 10| 15| 20
5| 16| 16| 16| 14
10| 16| 14| 12| 10
15| 16| 12| 10| 10
20| 14| 10| 10| 8
25| 14| 10| 8| 6
30| 12| 10| 8| 6
40| 12| 8| 6| 6
50| 10| 6| 6| 4
60| 10| 6| 4| 4
AMERICAN WIRE GAUGE GUIDE 24-VOLT:
Amp Draw
| Length of wire from battery to compressor (in feet)
---|---
5| 10| 15| 20
5| 16| 16| 16| 16
10| 16| 16| 16| 14
15| 16| 16| 14| 12
20| 16| 14| 12| 10
25| 16| 12| 12| 10
30| 16| 12| 10| 10
40| 14| 10| 10| 8
50| 14| 10| 8| 6
60| 12| 10| 8| 6
LIMITED WARRANTY
VIAIR Corporation warrants this product, when properly installed and under
normal conditions of use, to be free from defects in workmanship and materials
for a period of one year from its original date of purchase. To receive
warranty service or repair, please contact VIAIR Corporation.
Returns should be made within one year of the date of purchase, after a Return
Goods Authorization (RGA) number has been assigned by VIAIR Corporation. To
obtain RGA, fax a copy of your receipt to
949-585-0188. For complete warranty
details, please
visit: www.viaircorp.com/warranty
PLEASE NOTE:
THIS WARRANTY COVERS PRODUCT DEFECTS ONLY; IT DOES NOT COVER INCIDENTAL OR
CONSEQUENTIAL DAMAGES
AS RESULT OF MISUSE OR ABUSE.
This Manual is proprietary to VIAIR Corporation and no ownership rights are
hereby transferred. No part of the Manual shall be
used, reproduced, translated, converted, adapted, stored in a retrieval
system, communicated or transmitted by any means, for any commercial purpose,
including without limitation, sale, resale, license, rental or lease, without
the prior express written consent of VIAIR. VIAIR does not make any
representations, warranties or guarantees, express or implied, as to the
accuracy or completeness of the Manual. Users must be aware that updates and
amendments will be made from time to time to the Manual. It is the user’s
responsibility to determine whether there have been any such updates or
amendments. Neither VIAIR nor any of its directors, officers, employees or
agents shall be liable in contract, tort or in any other manner whatsoever to
any person for any loss, damage, injury, liability, cost or expense of any
nature, including without limitation incidental, special, direct or
consequential damages arising out of or in connection with the use of the
Manual.