Qidots F187 Remote Control Cabinet Lock User Manual

September 29, 2024
Qidots

F187 Remote Control Cabinet Lock

“`html

Specifications:

  • Remote Control Cabinet Lock

  • Model: V000240829

  • Power Source: Lock body – 3*AAA alkaline batteries, Remote
    control – CR2032 3V button battery

  • Range: Up to 10 meters

  • Automatic Unlocking: Activates when lock body battery is below
    3.6V for an extended period

Product Usage Instructions:

1. Binding the Lock Body to Remote Control:

Press the settings button on the lock body, then press the
remote control button within 5 seconds to bind the remote control
to the lock body.

2. Remote Control Unlocking:

Press the remote unlock button once to unlock the cabinet within
a range of 10 meters. The lock will automatically re-lock after 4
seconds.

3. Unbinding the Remote Control:

Press and hold the lock body setting switch for 5 seconds to
unbind the remote control from the lock body.

4. Low Battery Alarm:

If the remote control indicator light is dim or not functioning
properly, or if the lock is unresponsive, replace the CR2032 3V
button battery immediately. For the lock body, if the voltage drops
below 3.8V, it will emit 5 beeps and unlock. Replace the 3*AAA
alkaline batteries promptly.

5. Automatic Unlocking Function:

If the lock body battery falls below 3.6V for an extended
period, it will automatically unlock.

FAQ:

Q: How many remotes can be bound to one lock body?

A: Multiple remotes can be bound to a single lock body.

Q: What type of battery does the remote control use?

A: The remote control uses a CR2032 3V button battery.

“`

REMOTE CONTROL CABINET LOCK
USER MANUAL

1. How to bind the lock body
Press the settings button on the lock body, “Beep”, and press the remote control button within 5 seconds. “Beep,beep” two sounds, the remote control is bound. Note: Multiple remotes can be bound by one lock body.
Set the hole

1.Remote unlocking 2.Low power consumption and long battery life 3.Low battery warning 4.Support external emergency power supply

V000240829

2. Remote control unlocking (within 10M)
Press the remote unlock button once, the red light on, unlocking, and lock automatically after 4 seconds. If the remote control is not bound, press the unlock button, the red light on, and the lock body will not respond. Press the unlock button in the unlocked state, and the lock will delay for 4 seconds before locking.
3.How to unbind the remote control
Press the lock body setting switch for 5 seconds, “Beep,beep” five sounds, initialization successful.
4.Low battery alarm
Remote control low voltage alarm: when the remote control indicator light is dark or not bright, or when the lock is not sensitive, the remote control power is insufficient, please replace the battery immediately. Battery type: 3V button battery, CR2032. Lock body low voltage alarm:In case of voltage less than 3.8Vit will unlock with 5 “Beep” .Please replace the battery in time. Battery type: 3*AAA alkaline batteriesprohibit the use of carbon batteries.

5.Automatic unlocking function
When the lock body battery is below 3.6V for a long time, it will automatically unlock.
Notes
After installing the lock body, please use the remote control to unlock it once and confirm that the unlocking is normal; Keep the remote control properly and never put it in the drawer or cabinet of the lock.

16.7 10 13.4

TYPE-C External diagram
1. To drill a Ø 12MM mounting hole in the center of the mounting surface of the lock body within 80MM; 2. Insert the external connection into the mounting hole; 3. Then connect the external connection to the socket behind the lock body, arrange the connecting cable, and finally install the lock body.

14.5 14.5

Ø12

2. Connect the lock body, (Tide up the wire not crush), fix lock body by screw ST3X30 and screw ST3X16.

ST316 screw 3 AAA batteries (AAA) M36

Door thickness 10~20mm Lock Body Latch positioning cable 1

Battery Cover

32.25-A

Indicator Remote Control

Double-sided tape

Lock Body

Connecting Wire&Screws

Cabinet of Drawers installation guide

1.Lock body and latch positioning size chart

33.5cthe distance from inside board to the centre of screw hole of striking plate)
Top board

A(Pumping front plate and pumping top plate clearance) 32.25(the distance from inside board to the centre of screw hole of striking plate)

Striking Plate

Lock Body

Door board

Bottom board

ST3*30 screw

Lock body positioning wire

3. Fix the striking plate by screw ST3.5*14(Make sure latch works well)

striking plate ST3.5×14 screw

Picture 3

33.5+L L = door thickness

12mm Follow the drawing to drill the hole

FCC Warning Statement: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals