Haier AS105S2SF2FA-2 Monosplit Flair Owner’s Manual
- September 28, 2024
- Haier
Table of Contents
Haier AS105S2SF2FA-2 Monosplit Flair
Feature
| Nano-Aqua Sterilisation
---|---
| Easy Installation
| Silence
| Sleep
| On-Off Card
| 3D
- Nano-Aqua Sterilisation
- Easy installation
- Low noise level
- Comfortable Sleep
- On-Off Card
- 3D airflow: continuous movement of horizontal and vertical deflectors
- 2-Way Pipe Design
INDOOR UNIT
INDOOR UNIT OUTDOOR UNIT Performance data| Model Model| | AS105S2SF2FA-2
1U105S2SF2FA
---|---|---|---
Output power – COOLING| nom (min-max)| kW| 9,00 (2,50-10,00)
Output power – HEATING| nom (min-max)| kW| 9,50 (3,00-10,50)
Absorbed power – COOLING| nom (min-max)| kW| 3,00 (0,80-3,70)
Absorbed power – HEATING| nom (min-max)| kW| 2,56 (0,80-4,00)
Energy class| EER| W/W| 3,00
COP| W/W| 3,71
COOLING Designs| 35 °C| kW| 9,00
HEATING Designs| (-10 °C)| kW| 7,20
Energy class| SEER| | 6,10 (A++)
SCOP| | 4,00 (A+)
Annual Energy Consumption – COOLING| kWh/a| 516
Annual Energy Consumption – HEATING| kWh/a| 2518
Indoor Unit
Power supply| | Ph/V/Hz| 1/220~240/50/60
Treated air volume| Max| m3/h| 1300
High sound power| | dB| 65
Sound pressure| | dB(A)| 48/44/40/36
Net dimensions| WxDxH| mm| 1342x275x365
Packaging dimensions| WxDxH| mm| 1418x402x478
Net/gross weight| | kg| 21,0/25,5
Outdoor Unit
Power supply| | Ph/V/Hz| 1/220~240/50
Power cable| | N x mm2| 3 x 4,0
Interconnection cable| | N x mm2| 4 x 2,5
Sound power| H| dB| 70
Sound pressure| H| dB(A)| 60
Running current cooling/heating| Max| A| 16,5
Starting current cooling/heating| Max| A| 2,0
Compressor type| | | Twin rotary inverter
Net dimensions| WxDxH| mm| 920x372x765
Packaging dimensions| WxDxH| mm| 1050x485x1130
Net/gross weight| | kg| 85,0/90,0
Compressor type| | | Twin rotary inverter
Installation data
Refrigerant| | | R32
Liquid pipe| Ø| mm (inch)| 9,52 (3/8)
Gas pipe| Ø| mm (inch)| 15,88 (5/8)
Standard pipe length without refrigerant charge| m| 7
Maximum pipe length| | m| 50
Maximum IU – OU elevation| | m| 30
Refrigerant charge in the factory| | kg| 1,70
Refrigerant charge in the factory| | TCO2eq| 1,15
Additional ref, charge over std length| g/m| 45
Outdoor operating limits – COOLING| min-max| °C| -20~43
Outdoor operating limits – HEATING| min-max| °C| -20~24