Schneider Electric 2AX Iconic Connected Switch User Guide
- September 27, 2024
- Schneider Electric
Table of Contents
2AX Iconic Connected Switch
“`html
Specifications:
- Product Name: Iconic Connected Switch 2 AX
- Brand: Schneider Electric
- Model: 2AX
- Release Date: 09/2024
- Website: www.clipsal.com
Product Information:
The Iconic Connected Switch 2 AX is a device that offers
advanced features and functionality for smart home automation. It
is designed to provide easy control of lighting and other connected
devices.
Features:
- Smart home automation capabilities
- Compatible with various connected devices
- Easy installation and setup
- Enhanced control options
Usage Instructions:
Safety Information:
Before installing, operating, servicing, or maintaining the
Iconic Connected Switch 2 AX, carefully read and understand the
safety information provided in the manual. Pay attention to warning
symbols and messages to prevent potential hazards.
Installation:
-
Turn off power at the circuit breaker before installation.
-
Follow the wiring diagram provided in the manual to connect the
switch correctly. -
Securely mount the switch on the wall using appropriate
screws.
Operation:
To operate the Iconic Connected Switch 2 AX:
-
Use the designated control interface to turn lights or devices
on/off. -
Explore additional features such as scheduling and automation
through the accompanying app or software.
Maintenance:
Regularly check the switch for any signs of damage or wear.
Clean the switch with a dry cloth as needed.
FAQ:
Q: Can I use the Iconic Connected Switch 2 AX with voice
assistants?
A: Yes, the device is compatible with popular voice assistants
like Amazon Alexa and Google Assistant for voice control.
Q: Is the switch suitable for outdoor use?
A: No, the Iconic Connected Switch 2 AX is designed for indoor
use only.
“`
Iconic Connected Switch 2 AX
Device user guide
Information about features and functionality of the device. 09/2024
www.clipsal.com
Legal Information
The information provided in this document contains general descriptions,
technical characteristics and/or recommendations related to
products/solutions.
This document is not intended as a substitute for a detailed study or
operational and site-specific development or schematic plan. It is not to be
used for determining suitability or reliability of the products/solutions for
specific user applications. It is the duty of any such user to perform or have
any professional expert of its choice (integrator, specifier or the like)
perform the appropriate and comprehensive risk analysis, evaluation and
testing of the products/solutions with respect to the relevant specific
application or use thereof.
The Schneider Electric brand and any trademarks of Schneider Electric SE and
its subsidiaries referred to in this document are the property of Schneider
Electric SE or its subsidiaries. All other brands may be trademarks of their
respective owner.
This document and its content are protected under applicable copyright laws
and provided for informative use only. No part of this document may be
reproduced or transmitted in any form or by any means (electronic, mechanical,
photocopying, recording, or otherwise), for any purpose, without the prior
written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of
the document or its content, except for a non-exclusive and personal license
to consult it on an “as is” basis.
Schneider Electric reserves the right to make changes or updates with respect
to or in the content of this document or the format thereof, at any time
without notice.
To the extent permitted by applicable law, no responsibility or liability is
assumed by Schneider Electric and its subsidiaries for any errors or omissions
in the informational content of this document, as well as any non-intended use
or misuse of the content thereof.
Table of Contents
Safety Information……………………………………………………………………………4 Iconic Connected Switch
2AX………………………………………………………….5
For your safety ……………………………………………………………………………….5 About the
device……………………………………………………………………………..5 Installing the device
…………………………………………………………………………6 Pairing the device
……………………………………………………………………………6 Configuring the device
……………………………………………………………………..7
Setting the device location ……………………………………………………………7 Setting up the LED
Indicator Behaviour …………………………………………..8 Using the
device……………………………………………………………………………..9 Switching on/off the device manually
………………………………………………9 Turning On/Off device using app ………………………………………………….10
Schedule ……………………………………………………………………………….. 10 Moments
………………………………………………………………………………..12 Automation ……………………………………………………………………………..
15 Resetting the device manually ………………………………………………………….21 LED
Indication………………………………………………………………………………22 Troubleshooting
……………………………………………………………………………22 Technical data
………………………………………………………………………………23
Compliance ……………………………………………………………………………………24
Compliance information for Green Premium products…………………………….24
Trademarks…………………………………………………………………………………. 24
DUG_Iconic Switch 2 AX_WHP-01
3
Safety Information
Safety Information
Important Information
Read these instructions carefully and look at the equipment to become familiar
with the device before trying to install, operate, service, or maintain it.
The following special messages may appear throughout this manual or on the
equipment to warn of potential hazards or to call attention to information
that clarifies or simplifies a procedure.
The addition of either symbol to a “Danger” or “Warning” safety label
indicates that an electrical hazard exists which will result in personal
injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that accompany this symbol to avoid
possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury. Failure to follow these instructions will result in
death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
4
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
Iconic Connected Switch 2AX
41E2PBSWMZ-VW PDL356PB2MBTZ-VW
For your safety
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH · It is illegal for persons
other than an appropriately licensed electrical
contractors or other persons authorised by legislation to work on the fixed
wiring of any electrical installation. · To comply with all safety standards,
the device must be used only for the purpose described in this instruction and
must be installed in accordance with the wiring rules and regulation in the
location where it is installed. · Lock out and tag the input circuit before
accessing the wiring connections. · The Locking Bar on the grids must be set
to the Closed position to ensure that the device cannot be removed during
normal operation. · There are no user serviceable parts inside the device.
Failure to follow these instructions will result in death or serious injury.
NOTICE
EQUIPMENT DAMAGE HAZARD (LOAD AND OPERATION) · Operation of the device at
elevated temperatures or voltages outside of
specification (240 V A.C. and 25 °C) may cause the over-temperature protection
circuitry to operate. · Reduce the size of the connected load or use a
different brand of fan to prevent recurrence. · Do not operate the product for
prolonged periods in extreme conditions. Failure to follow these instructions
can result in equipment damage.
About the device
The Iconic Connected Switch 2AX(hereinafter referred to as relay switch)
operates as a switch “out-of-the-box”, with no configuration needed. The relay
switch is available with Zigbee connectivity and can be used as a single
device within a Wiser network. To do this, the relay switch must be paired to
the Wiser Hub using the Wiser Home app.
DUG_Iconic Switch 2 AX_WHP-01
5
Installing the device
Iconic Connected Switch 2AX
Refer to the installation instruction supplied with this product. See Iconic Connected Switch 2AX, Zigbee/BLE.
Pairing the device
Using the Wiser Home app, pair your relay switch with the Wiser Hub to access
and control the relay switch.
1. On the Home page, tap .
2. Tap Devices > > Lights > Iconic switch/dimmer > Next. NOTE: The next
screen shows the joining process of relay switch.
3. Short press the push button 3 times and make sure that the LED blinks
amber.
3x
4. Wait for a few seconds until the LED turns green. You can also see in the
app that the device is joined. NOTE: If the LED is blinking green and red, see
the instructions by tapping the link LED blinking green and red?.
Iconic switch/dimmer setup Short-press the push button three times.The LED
will start blinking amber.
Device joined
5. Tap Next to enter the name of the device and assign the device to a new
room or an existing room. The relay switch is now listed under All devices.
6
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
Configuring the device
Using the Wiser home app, you can configure the device according to your
preferences.
1. On the Home page, tap . 2. Tap Devices > Lights > Relay switch to locate
to the Device Details screen.
Device Details Iconic Switch
F
Good Signal (-30dBm) ?
OPTIONS
Device Name
Iconic Switch
A
Location
Living Room
B
LED Indicator Behaviour
C
LED On when Power is On
ABOUT
Firmware Version
y
Identify
D
Delete
E
A
Device Name: Tap to change the name of the device.
B
Location: Tap to assign the Device to any room (such as living room, bedroom, kitchen etc). Refer to Setting the device
location, page 7 for more details on how to set the location.
C
LED Indicator Behaviour: Tap to set the LED indicator behaviour of the device as per your preference. Refer to Setting up the
LED Indicator Behaviour, page 8 for detailed information on each option.
D
Identify: Tap to identify the device. The status LED blinks red and connected lighting devices blinks On/Off, upon successful
identification of the switch.
Tap OK when you finish identifying the device.
E
Delete: Tap to remove the device from the system.
NOTE:
· Removing the device will also reset the switch. After reset, the LED turns amber indicating that the switch is ready for pairing.
· If there is a problem while pairing or resetting the switch, refer to Resetting the device manually, page 21
F
Zigbee Signal Strength Indicator: Zigbee Signal Strength indicator which displays the current signal strength of the device.
·
Good Signal (between 0 & -54dBm)
·
Normal Signal (between -54 & -79dBm)
·
Poor Signal (<-79dBm)
·
No Signal (device is offline)
Setting the device location
You can change the device location using Wiser Home app (such as bedroom,
living room, dining room etc.).
DUG_Iconic Switch 2 AX_WHP-01
7
Iconic Connected Switch 2AX
1. On the Home page, tap . 2. Tap Devices, select the device from the list
for which you wish to change the
location.
3. Tap Location to open setup page. 4. On setup page, you can enter New room
name (A) or select an existing room
from the list (B).
Device Setup
Where does this device control?
New room name
A
Living Room
3 Devices
Kitchen
2 Devices
B
Bathroom
3 Devices
Bedroom
2 Devices
Remove from Room
C
Submit
D
TIP: If the device is already assigned, you can remove it from the existing room. Tap Remove from Room (C). 5. Once changes are done, tap Submit (D).
Setting up the LED Indicator Behaviour
Using the Wiser Home app, you can set the behaviour of the LED indicator on
your device to identify the device status.
1. On the Home page, tap . 2. Tap Devices > Lights. 3. Select the device you
want to update and tap LED Indicator Behaviour.
NOTE: If you are unable to find the option in your app, reset the device to
factory default and perform the pairing process.
8
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
4. Select one of the following options as per your preference.
Device Details
1-Gang
OPTIONS
Good Signal (-30dBm) ?
Device Name
Location
LED On when Power is on
RL-LED Mode
?
LED Indicator Behavior
LED On when Power is On
Power On Behavior MLasint Oimn BurmightBnersigs hLetvneel sAs lways On
Maximum Brightness
ABOUT Firmware Version 00.00.000
Identify
Delete
LED On when Power is on LED Off when Power is on Always Off Always On
The LED turns On when the device is On. The LED turns Off when the device is On. The LED stays Off all the time. The LED stays On all the time.
Using the device
Switching on/off the device manually
You can switch on/off the device manually. The device will provide power to
the electrical appliance connected to it. Short press the push button once to
turn on/off the iconic switch.
DUG_Iconic Switch 2 AX_WHP-01
9
Iconic Connected Switch 2AX
Turning On/Off device using app
Using the Wiser Home app, you can turn On/Off the relay switch remotely.
Follow the steps to turn On/Off the relay switch using the app:
1. Go to the Home page, tap All and find the device. 2. Tap (A) to turn
On/Off relay switch.
18°
Plymouth
07:05 21:35
All Living Room Kitchen Bedroom
Living Room
Relay Switch
A
Home
Automations
Energy
Schedule
You can set up schedules to specify the times at which a state of the device changes.
Setting up a schedule
The relay switch can be fully controlled by a schedule. Once the schedule is
set, the relay switch operates at a given time.
1. On the Home page, tap .
2. Go to Schedules and tap to create a schedule. 3. Enter the name of the
schedule (A). 4. In the TYPE menu, select Lights (B). 5. In the APPLIES TO
menu, select Relay Switch (C) from the listed devices.
10
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
6. Tap Create to setup events.
New schedule
NAME
Schedule Name
A
TYPE
Lights
B
Shutters
APPLIES TO
Relay Switch
C
Create
7. Under EVENTS menu, select a day and then Tap to add an event such as STATE
(lights On/Off) and WHEN (sunrise/sunset or specific time range).
8. Tap Set to save the schedule. TIP: · You can add multiple schedules based
on your requirement. Select days, tap , set on/off state and time. · You can
copy the existing schedule to another schedule or to the days of your choice.
Tap . Tap Schedule and select an existing schedule and tap Copy. Tap Day and
select the days you want to assign and tap Copy.
Editing a schedule
1. On the Home page, tap > Schedules 2. Tap the schedule you want to edit.
DUG_Iconic Switch 2 AX_WHP-01
11
Iconic Connected Switch 2AX
3. Tap the SCHEDULE DETAILS and you can do the following actions: Rename
the schedule (A). Within the Applies to (B) menu, you have the option to
select from the listed devices or deselect those that are already selected.
Under the EVENTS (C) menu, you can edit the day and then tap to edit an
event such as STATE (lights Off or dimming level in %) and WHEN
(sunrise/sunset or specific time range).
Schedule-01
SCHEDULE DETAILS
Type Lights
Name Schedule-01
A
Applies to
B
Delete
EVENTS
M T W T F S S
C
12:12
21:51
?
NOTE: When the above changes are edited, the schedule is saved automatically.
Deleting a schedule
1. On the Home page, tap Automations > Schedules. 2. Tap the schedule you
want to delete. 3. Tap the SCHEDULE DETAILS and then tap Delete.
Moments
Moment allows you to group multiple actions that are usually performed together. By using the Wiser Home app, you can create moments based on your needs.
Creating a moment
1. On the Home page, tap .
2. Go to Moments and tap to create a moment. 3. Enter the name of the moment
(A).
TIP: You can choose the cover image that represents your moment by tapping .
12
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
4. Tap Add actions (B) to select the list of devices.
Close
Moment creator
Save
Name e.g. Movie Night
A
Actions
Add actions
0 of 60
B
5. In the Add actions menu, you can select the devices (C).
Select devices
Please select the devices you want to add to this moment.
All Test Three Heating
Test Rotary dimmer
Shutter
Three
C
Push button dimmer
Light Light
Done
6. Once the device are selected, tap Done. 7. On the Moment creator page, tap
the device to set the condition. For
example, it it is a relay switch: Tap to turn on (D) and tap Set on the
upper right corner.
Light
Set
Tap to turn On
D
DUG_Iconic Switch 2 AX_WHP-01
13
Iconic Connected Switch 2AX
8. After setting all conditions, tap Save. Once the moment is saved, it will
appear on the Moments tab. Tap on the moment to enable it.
Editing a moment
1. On the Home page, tap Automations .
2. Go to Moments, locate the moment you want to edit and tap . 3. On the
Moment editor page, you can perform following changes:
· Change the icon . · Rename the moment. · Tap each action to change the
settings.
To remove an action, slide the action to the left and then tap delete it.
Tap Add actions (B) to add new action.
(A) to
Close
Moment editor
Save
Living Room
Actions
1 of 60
A
Add actions
B
Delete
4. Tap Save, to save the changes.
Deleting a moment
1. On the Home page, tap Automations . 2. Go to Moments, locate the moment you want to delete and tap .
14
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
3. On the Moment editor page, tap Delete (A) and then tap Ok (B).
Close
Moment editor
Save
Living Room
Actions
1 of 60
Moments
Are you sure you want to delete this Moment?
CANCEL OK
B
Add actions
Delete
A
Automation
An automation allows you to trigger an action automatically or at scheduled times. By using the Wiser Home app, you can create automations based on your needs. This example demonstrates how a device works when the condition is met.
Creating an automation
1. On the Home page, tap .
2. Go to Automation and then tap to create an automation. 3. Enter a name of
the automation (A) and select any of the following conditions
to trigger an automation. All conditions: All conditions must be met to
trigger an automation Any condition: Any one of the condition must be met to
trigger an
automation. TIP: You can choose the cover image that represents your
automation by tapping
Close
New automation
Save
Evening movie
A
If
When
Conditions are met
All conditions
Then 0 of 10 Any condition
Start by adding a condition that will trigger your automation
Add conditions
DUG_Iconic Switch 2 AX_WHP-01
15
Iconic Connected Switch 2AX
4. Tap Add conditions (B) and select any of the following (C): Device
status change (Select the device): An automation will be triggered based on a
device status, such as the opening of a shutter or the detection of movement
by a motion sensor. Away Mode (Enable or Disable): Away mode can also
trigger an automation to turn on the lights, close the shutter etc. For more
information about Away Mode, refer to the system user guide. NOTE: Maximum 10
conditions can be added.
Close
New automation
Save
Evening movie
If
When
Conditions are met
All conditions
Then 0 of 10 Any condition
Add conditions
Please choose the triggers to activate your automation.
Device status change
E.g. if motion is detected
C
Away Mode
E.g. if away mode is on
Start by adding a condition that will trigger your automation
Add conditions
B
a. In this example, we will select Device status change and choose a device to
set the condition. Then, we will select the state of the device that will
trigger the automation, such as the closed state of a .
Select devices Please select the devices you want to add
All Living Room Kitchen Bedroom Living Room
Radiator Bedroom
Micromodule shutter Kitchen
Dimmer Relay switch
b. After selecting the device, tap Set on the upper right corner. TIP: If you want to change the condition, swipe it to the left and tap the bin icon. Then add a new condition with the required parameters.
16
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
5. To start your automation at a particular time, tap When > Add time and
select any of the following (D):
NOTE: Maximum 10 time entries can be added.
Specific time of day – The automation will trigger at a specific time of the
day, such as at sunrise, sunset, or at 8:00 AM.
Period of time – The automation will be trigger during time periods such as
from sunrise to sunset, from sunset to sunrise, or from 8:00 AM to 5:00 PM.
Close
New automation
Save
Add time
e.g. Good Morning
E.g. at 07:00 or at sunrise
D
If
When
Then
E.g. from sunset to sunrise
At this time
0 of 10
Add time
DUG_Iconic Switch 2 AX_WHP-01
17
Iconic Connected Switch 2AX
6. To add an action, tap Then > Add an action and select any of the following
(E): NOTE: Maximum 10 actions can be added. Control a device – Select the
device and set the desired state of the device. Send notification – You will
be notified if the condition is met. Activate a moment – Select a Moment to
activate during the automation. Wait – This option allows you to add a delay
in an automation sequence. You can set the wait time in increments of 1 hour
and 1 minute, up to a maximum of 24 hours. This feature is useful for delaying
actions within an automation.
Close
New automation
Save
e.g. Good Morning
If Run this action
When
Then 0 of 10
Select an action that works best for your automation.
Add an action
Please choose an action for your automation.
Control a device E.g. turn the light on
E.g. if the motion is detected
E
Activate a moment
E.g. enable Away mode
Wait E.g. wait 10 mins until next action
Add an action
a. In this example, we will select for Control a device and choose Relay switch (F) as the device to trigger an action.
Add an action
Please choose an action for your automation.
Control a device E.g. turn the light on
E.g. if the motion is detected Activate a moment E.g. enable Away mode Wait
E.g. wait 10 mins until next action
Select devices
Please select the devices you want to add to this moment.
All Living Room Kitchen Bedroom Living Room
Smart Socket
Radiator
Bedroom Blind control switch
Kitchen Dimmer
Relay switch
F
b. Set the state, such as turning the relay switch On/Off. Then, tap Set located on the upper right corner
18
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
Relay switch
Set
On
OR
Relay Switch
Set
Tap to turn On
c. Again, tap Add an action and select Wait option.
d. Scroll through the minutes and set the wait time to 1 minute. Then, tap Set
located on the upper right corner.
WAIT
Add a Wait
Set
00 hrs 01
00 01 min 02
7. Tap Save. The saved automation is displayed on the Automation page. Tap the toggle switch (G) on the Automation page to enable/disable the Automation.
Automations
Moments Automations
Automations
Schedules
Evening movie
G
Home
Automations
Insights
DUG_Iconic Switch 2 AX_WHP-01
19
Editing an automation
Iconic Connected Switch 2AX
1. On the Home page, tap Automations . 2. Go to Automation, tap the
automation you want to edit. 3. On the Edit automation page, you can perform
following changes:
· Change the icon . · Rename the automation. · Tap each condition to change
the settings.
To remove a condition, slide the condition towards left and then tap (A) to
delete it.
Tap Add conditions (B) to add new condition. · To change the order of actions,
tap the Then option, and hold an action
then drag and drop to the desired position.
Close
Edit automation
Save
Living Room
If
When
Conditions are met All conditions
Then 1 of 10 Any condition
A
Close
Edit automation
Save
If
When
Then
Run these actions
3 of 10
You can move cards to choose the order of the actions.
On
Moment Wait
Wait
Activate 1 min
1 min
Add conditions
B
Delete automation
Add an action Delete automation
4. Tap Save to save the changes.
Deleting an automation
1. On the Home page, tap Automations . 2. Go to Automation, tap the
automation you want to delete.
20
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
3. On the Edit automation page, tap Delete automation (A) and read the confirmation message and then tap OK (B).
Close
Edit automation
Save
Living Room
If
When
Conditions are met All conditions
Then 1 of 10 Any condition
Are you Sure?
Your Living Room automation will be deleted and can not be recovered.
CANCEL OK
B
Add conditions
Delete automation
A
Resetting the device manually
You can reset the device to factory default manually. Short press the push
button three times (<0,5 s) and then long press the push button once (>10 s).
After 10 s, release the push button when the LED starts blinking red.
3× < 0,5s + 1× 10s
NOTE: After reset, the LED turns amber/orange indicating that device is ready for pairing.
DUG_Iconic Switch 2 AX_WHP-01
21
LED Indication
Pairing
User Action Press the push-button 3 times
Iconic Connected Switch 2AX
LED Indication LED blinks amber/orange
LED blinks orange for Zigbee.
LED blinks red green, for Bluetooth.
Status
Pairing mode is active for 30 seconds. When pairing is completed, LED glows
green for some time before turning off.
Changing protocol
User Action Short press the push-button 3 times and long press once for > 20
s.
Resetting
User Action Press the push-button 3 times and long press once for > 10 s.
LED Indication LED blinks red rapidly indicating commence of protocol change.
Status
On successful change in protocol:
· Zigbee to Bluetooth – No colour indication, white back light only.
· Bluetooth to Zigbee – Flashing Amber LED (Indicating that device is in
pairing mode), if pairing is not completed will become solid Amber
LED Indication After 10 s, the LED blinks red.
Status
The device resets to the factory default after 10 seconds. The device then
restarts and the LED blinks amber/orange indicating that it is ready for
pairing.
For Zigbee, the device is reset to the factory settings after 10 seconds. The device then restarts and the LED blinks orange indicating that it is ready for pairing.
LED Indicator Mode
Load Status Reverse with load Consistent with load Always Off Always On
ON No LED White LED is on No LED White LED is on
For Bluetooth, the device is reset to the factory settings after 10 seconds
and the device turns off.
OFF White LED is on No LED No LED White LED is on
Troubleshooting
Error The device is not ready to pair after the device is removed from the
app.
Possible cause The device is not reset correctly.
Solution
Reset to factory default settings, refer to Resetting the device manually,
page 21.
22
DUG_Iconic Switch 2 AX_WHP-01
Iconic Connected Switch 2AX
Technical data
Nominal power rating for load type
Load type
Load name
Incandescent lamp
Halogen lamp
L
Nominal voltage Nominal current Switching technique
lighting transformer Fluorescent lamp Inductive load
Protection
LED indicator Supported protocols Mutli-gang plate capacity Compatible plate ranges Mounting centers Safety compliance EMC emission compliance IP rating Communication protocol Operating humidity Specifications typical at 25 °C Compliance Safety EMC RF
Load value 2A
2A
2A
2A
2 A @ 0.6 PF
AC 220-240 V, 50 Hz 2A Relay Over temperature: Yes Short circuit:: No Over-
current fuse: No Thermal protection: Yes Yes Zigbee, BLE Max 6 primary mechs
per plate Iconic, Iconic Styl, Iconic Essence, Pro Series 84 mm pattern plate
AS/NZS 60669.2.1 IP20 Zigbee, BLE 5%-90% RH, non-condensing
AS/NZS 60669.2.1 AS/NZS 60669.2.1 AS/NZS 4268
DUG_Iconic Switch 2 AX_WHP-01
23
Compliance
Compliance
Compliance information for Green Premium products
Find and download comprehensive information about Green Premium products,
including RoHS compliance and REACH declarations as well as Product
Environmental Profile (PEP) and End-of-Life instructions (EOLI).
https://checkaproduct.se.com/
General information about Green Premium products
Click the link below to read about Schneider Electric’s Green Premium product
strategy.
https://www.schneider-electric.com/en/work/support/green-premium/
Trademarks
This guide makes reference to system and brand names that are trademarks of
their relevant owners.
· Zigbee® is a registered trademark of the Connectivity Standards Alliance.
· Apple® and App Store® are brand names or registered trademarks of Apple Inc.
· Google PlayTM Store and AndroidTM are brand names or registered trademarks
of Google Inc.
· Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
· WiserTM is a trademark and the property of Schneider Electric, its
subsidiaries and affiliated companies.
Other brands and registered trademarks are the property of their respective
owners.
24
DUG_Iconic Switch 2 AX_WHP-01
Schneider Electric (Australia) Pty Ltd 33-37 Port Wakefield Road Gepps Cross
SA 5094 Australia Customer Care: 13 73 28 www.clipsal.com
As standards, specifications, and design change from time to time, please ask
for confirmation of the information given in this publication.
© 2024 2024 Schneider Electric. All rights reserved. DUG_Iconic Switch 2
AX_WHP-01
Read User Manual Online (PDF format)