Altronix NetWay5PQWP Series Outdoor Network Managed PoE Plus Switch Installation Guide
- September 28, 2024
- Altronix
Table of Contents
Altronix NetWay5PQWP Series Outdoor Network Managed PoE Plus Switch
Installation Guide
NetWay5PQ Series
LINQ Managed 5-Port Hardened PoE+ Switches
Models Include:
NetWay5PQWP
- 5-port Managed Hardened PoE Switch with Power Supply/Charger
- NEMA4/4X, IP66 rated Outdoor enclosure.
NetWay5PQWPX
- 5-port Managed Hardened PoE Switch with Power Supply/Charger
- NEMA4/4X, IP66 rated Outdoor enclosure.
- Accommodates up to four (4) 12VDC/4AH batteries.
NetWay5PQX
- 5-port Managed Hardened PoE Switch with Power Supply/Charger
- NEMA1 rated Indoor enclosure.
NetWay5PQWPN
- 5-port Managed Hardened PoE Switch
- NEMA4/4X rated outdoor enclosure
NetWay5PQ
- 5-port Managed Hardened PoE Switch
- Board Only
Installation Guide
Rev. 012924
Installing Company: ___ Service Rep. Name:
Address: _____ Phone #:
Overview
Altronix Netway5PQ Series are LINQ managed hardened PoE+ switches. They provide a network data uplink and four (4) PoE ports to power IP devices, such as PoE access controllers and cameras. Other applications may include solar power (with NetWay5PQ and NetWay5PQWPN), as well as integrating network door access systems with video surveillance.
For unmanaged switches see NetWay5P Series.
Features
Input:
-
NetWay5PWPQ, NetWay5PWPQX, NetWay5PQX:
120VAC, 60Hz, 2.5A. -
NetWay5PQ/NetWay5PQWPN:
12 or 24VDC from a UL Listed power source or a solar panel with nominal 24V (~12-35V) output.
Current draw: 6A @ 24VDC at maximum 120W output.
Output:
-
Four (4) PoE/PoE+ ports.
-
IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant.
-
Maximum Output Power:
120W at 24VDC/6A.
60W at 12VDC/6A. -
Single data uplink port.
Ethernet Ports:
- Five (5) 10/100/1000 Mbps ports.
- Connectivity: RJ45, auto-crossover.
- Wire type: 4-pair CAT5e or higher structured cable.
- Distance: up to 100m.
- Speed: 10/100/1000 Mbps, half/full duplex, auto negotiation.
LINQ Technology:
- Remote network management allows for camera/ device reset and monitoring.
- PoE port management via Dashboard IP management program.
- Provides local and/or remote access to critical information via LAN/WAN.
- Email and Windows Dashboard Alert notifications report real-time diagnostics.
- Event log tracks history.
VLAN:
- Multiple management VLAN assignment.
- 802.1Q Tagged VLAN.
- Up to 10 VLAN groups. ID Range 2-4095.
LED Indicators:
- Individual PoE On LEDs for each port.
- Individual IP Link status, 100/1000Base-T/active LEDs for each port.
Environmental:
- Operating Ambient Temperature:
– 30ºC to 70ºC (– 22ºF to 158ºF).
- Storage Temperature:
– 40ºC to 85ºC (– 40ºF to 185ºF).
- Humidity: 20 to 85%, non-condensing. • Operating Altitude: – 304.8 to 2,000m. Applications:
- Allows to power up to four (4) IP devices and networking of multiple remote devices without the need for running multiple cables from the main switch/server.
Mechanical:
NetWay5PQ:
- Dimensions (L x W x D approx.):
5.9” x 3.6” x 0.75” (150mm x 91.4mm x 19mm). NetWay5PQWPN
- NEMA 4X, IP66 Rated enclosure for outdoor use. • Dimensions (H x W x D approx.):
9.5” x 7.32” x 4.92”
(241.3mm x 185.9mm x 125mm).
NetWay5PQWP:
- NEMA4/4X, IP66 Rated enclosure for outdoor use. • Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59”
(338.1mm x 287.3mm x 142mm).
NetWay5PQWPX:
- NEMA4/4X, IP66 Rated enclosure for outdoor use. • Accommodates four (4) 12VDC/4AH batteries (48V of backup).
- Dimensions (H x W x D approx.):
17.53” x 15.3” x 6.67”
(445.3mm x 388.6mm x 169.4mm).
NetWay5PQX:
- Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 83mm).
– 2 – NetWay5PQ Series Installation Guide
Fig. 1 – NetWay5PQ Board Configulration1e
MASTER RESET
1d
Netway5P
GND +24V
– +
PORT1 PORT2
DATA INPUT
PORT3 PORT4
1b
DATA IN
1a
1000
Netway5PQ
LED2 LED1
LED4 LED3
LED6 LED5
LED8 LED7
LED11 LED10
100
10/100/1000
PORT1
Altronix Corp.
Brooklyn, NY US
www.altronix.com
PORT2
PORT3
PORT4
1c 1c 1c 1c
Fig. 2 – eFlow104NB Board Configuration
– DC +
2h
– BAT +
2g
AC1 AC DC NO GND
1 min enable
L G N NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL
2 hr disable
SUPERVISED
RESET + AUX –
2a 2b
2c 2d 2e 2f
NetWay5PQ Series Installation Guide – 3 –
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. All units should be installed by a trained service personnel.
Installation:
NetWay5PQ:
- Mount NetWay5PQ in the desired location/enclosure (mounting hardware included). 2. Connect NetWay5PQ to power source and Ethernet devices:
NetWay5PQ can be powered by a UL Listed 12 or 24VDC power source, e.g. Altronix eFlow power supply/ charger or a solar panel with nominal 24V (~12-35V) output.
- Connect a power source to the [GND +24V] terminals carefully observing polarity (Fig. 1a, pg. 3). 4. Connect a Data source to the [Data Input] RJ45 jack (Fig. 1b, pg. 3).
- Connect Access Control boards, Altronix LINQ units or other IP devices to the [Port 1 – Port 4] RJ45 jacks (Fig. 1c, pg. 4). Refer to the corresponding Installation Guides for details.
NetWay5PQWPN/NetWay5PQWP/NetWay5PQWPX:
- Remove backplane from enclosure prior to drilling. Do not discard hardware.
Note: Make sure that hardware will not interfere with components of the circuit board. 2. Mark and drill desired inlets on the enclosure to facilitate wiring . Maximum NEMA type 4X rated fittings to be used are 0.5”. Follow manufacturer’s specifications for the appropriate size opening. Note: Inlets for conduit fittings should only be made on the bottom of the enclosure.
To facilitate wire entry utilize weather-tight NEMA rated connectors (supplied) , bushings, and cable. 3. Clean out the inside of enclosure before remounting circuit boards/backplane.
- Mounting NEMA4/4X rated enclosure (Enclosure Dimensions, pg. 13-15) :
Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom hole of the enclosure flange. Secure enclosure with appropriate fasteners (e. g. screws and anchors; bolts and locking nuts, etc.) that are compatible with mounting surface and are of sufficient length/construction to ensure a secure mount (Fig. 5, pg. 12).
Pole Mount: Refer to Fig. 6 – 11, pg.12.
- Mount backplane in enclosure with hardware.
NetWay5PQX:
- Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two (2) upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two (2) upper screws; level and secure. Mark the position of the lower two (2) holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure’s upper keyholes over the two (2) upper screws. Install the two (2) lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 16). Secure enclosure to earth ground. Power Connection:
NetWay5PQWP, NetWay5PQWPX, NetWay5PQX:
- Connect unswitched AC power (120VAC 60Hz) to terminals marked [L, N] (Fig. 2a, pg. 3). Green “AC” LED on power supply board will turn on. Use 14 AWG or larger for all power connections.
Secure green wire lead to earth ground.
Keep power-limited wiring separate from non power-limited wiring (120VAC 60Hz Input, Battery Wires). Minimum 0.25” spacing must be provided.
CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.
- When the use of stand-by batteries is desired, they must be lead acid or gel type. If batteries are housed in a weather-proof enclosure (NetWay5PQWP, NetWay5PQWPX), it must be properly ventilated. Use Altronix Vent2 kit. Connect battery to terminals marked [– BAT +] (Fig. 2g, pg. 3). Use two (2) 12VDC batteries connected in series for 24VDC operation (battery leads included) Use batteries – Casil CL1270 (12V/7AH), CL12120 (12V/12AH), CL12400 (12V/40AH), CL12650 (12V/65AH) batteries or UL recognized BAZR2 batteries of an appropriate rating. When batteries are not used, a loss of AC will result in the loss of the output voltage. 3. Connect appropriate signaling notification devices to AC FAIL & BAT FAIL (Fig. 2b, pg. 4) supervisory relay outputs.
– 4 – NetWay5PQ Series Installation Guide
- To delay AC reporting for 2 hrs. set DIP switch [AC Delay] to OFF position (Fig. 2c, pg. 3). To delay AC reporting for 1 min. set DIP switch [AC Delay] to ON position (Fig. 2c, pg. 3). Note: Must be set to ON position for Burglar Alarm Applications.
- To enable Fire Alarm Disconnect set DIP switch [Shutdown] to ON position (Fig. 2c, pg. 3). To disable Fire Alarm Disconnect set DIP switch [Shutdown] to OFF position (Fig. 2c, pg. 3). 6. Trigger terminals are end of a line resistor supervised (10k ohms). Opening or shorting trigger terminals will cause [DC] output to shutdown (Fig. 2d, pg. 3).
- Place a jumper for non-latching FACP. A momentary short on these terminals resets FACP latching [Trigger EOL Shutdown] (Fig. 2e, pg. 3).
NetWay5PQ, NetWay5PQWPN:
- Mount NetWay5PQ/NetWay5PQWPN in the desired enclosure/location (mounting hardware is included). 2. NetWay5PQ/NetWay5PQWPN can be powered by a UL Listed 12/24VDC power source, e.g. Altronix eFlow power supply/chargers or a solar panel with nominal 24V (~12-35V) output.
Input/Data Connections:
- Connect a Data source to the [Data Input] RJ45 jack (Fig. 1b, pg. 4).
- Connect Access Control boards, Altronix LINQ units or other IP devices to the [Port 1 – Port 4] RJ45 jacks (Fig. 1c, pg. 3). Refer to the corresponding Installation Guides for details.
Terminal and Port Identification:
NetWay5PQ PoE+ Switch
Terminal/Port
Legend
| Function/Description
---|---
GND +24V| Connect a 12/24VDC UL Listed power source to these terminals
carefully observing polarity. Factory connected to power supply in
NetWay5PQWP, NetWay5PQWPX, NetWay5PQX (Fig. 1a, pg. 3)
Data Input| Can be used as a Data Uplink (Fig. 1b, pg. 3).
Port 1 – Port 4| Data and PoE/PoE+ (IEEE 802.3af (15W) and IEEE 802.3at (30W)
compliant) ports (Fig. 1c, pg. 3).
Master Reset| Resets NetWay5P/NetWay5PQ to factory settings. See Factory Reset
Option , pg. 9 (Fig. 1d, pg. 3).
USB Port| Can be used as an option to configure the Netway5PQ for managed
operation (Fig. 1e, pg. 3).
eFlow104NB Power Supply/Charger
Terminal Legend | Function/Description |
---|---|
L, N | Connect 120VAC 60Hz to these terminals: L to hot, N to neutral (non |
power-limited) (Fig. 2a, pg. 3).
– DC +| 24VDC nominal @ 10A continuous output factory connected to NetWay5PQ
(Fig. 2h, pg. 3).
Trigger EOL
Supervised
| Fire Alarm Interface trigger input from a short or FACP. Trigger inputs can
be normally open, normally closed from an FACP output circuit (power-limited
input) (Fig. 2d, pg. 3).
NO, GND RESET| FACP interface latching or non-latching (power-limited) (Fig.
2e, pg. 3).
+ AUX –| Auxiliary Class 2 power-limited output rated @ 1A (unswitched)
(Fig. 2f, pg. 3).
AC Fail
NC, C, NO
| Indicates loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized when AC power is present.
Contact rating 1A @ 30VDC (power-limited) (Fig. 2b, pg. 3).
Bat Fail
NC, C, NO
| Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present. Contact rating 1A @ 30VDC.
A removed battery is reported within 5 minutes.
Battery reconnection is reported within 1 minute (power-limited) (Fig. 2b, pg. 3).
– BAT +| Stand-by battery connections. Maximum charge current 1.54A (non power-limited) (Fig. 2g, pg. 3).
NetWay5PQ Series Installation Guide – 5 –
Technical Specifications:
Parameter | Description |
---|
Input Power
Requirements
| NetWay5PQWP, NetWay5PQWPX, NetWay5PQX: 120VAC, 60Hz, 2.5A.
NetWay5PQ/NetWay5PQWPN: 12/24VDC from a UL Listed power source or a solar
panel with nominal 24V (~12-35V) output. Current draw: 6A at maximum 120W
output.
Output| Four (4) PoE/PoE+ ports. Single data uplink port.
Indicators| NetWay5PQ: Individual PoE On LEDs for each port.
Individual IP Link status, 100/1000Base-T/active LEDs for each port. eFlow104NB: AC input and DC output LED indicators.
Environmental Conditions| Operating Ambient Temperature: – 30ºC to 70ºC (– 22ºF to 158ºF). Storage Temperature: – 40ºC to 85ºC (– 40ºF to 185ºF). Humidity: 20 to 85%, non-condensing.
Operating Altitude: – 304.8 to 2,000m.
Weights
(approx.)
| Model| Product Weight| Shipping Weight
NetWay5PQWP
NetWay5PQWPN
NetWay5PQWPX
NetWay5PQX
NetWay5PQ
| 10.5 lb. (4.76 kg)
3.7 lb. (1.68 kg)
15 lb. (6.8 kg)
6.65 lb. (3.02 kg)
0.25 lb. (0.11 kg)
| 11.9 lb. (5.4 kg)
5 lb. (2.27 kg)
17.5 lb. (7.9kg)
7.55 lb. (3.42kg)
0.75 lb. (0.34 kg)
– 6 – NetWay5PQ Series Installation Guide
Typical Application:
Fig. 3
12 or 24VDC from UL Listed Power Supply*
or
Solar Panel with nominal 24V (~12-35V) output
USB Port for configuring MASTER RESET
Data Uplink DATA INPUT
GND +24V
– +
Netway5P
PORT1 PORT2
PORT3 PORT4
DATA IN
1000
Netway5PQ
LED2 LED1
LED4 LED3
LED6 LED5
LED8 LED7
LED11 LED10
100
10/100/1000
PORT1
Altronix Corp.
Brooklyn, NY US
www.altronix.com
PoE
LEDs
PORT2
PORT3
PORT4
To Networked Access Controllers, Devices & Cameras and/or Altronix LINQ Series Ethernet connections
*NetWay5PQWP, NetWay5PQWPX and NetWay5PQX are factory connected to Power Supply
NetWay5PQ Series Installation Guide – 7 –
Configuring NetWay5PQ for Network Connection
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Please be sure to visit altronix.com for latest
firmware and installation instructions
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Factory Default Settings
- IP Address: 192.168.168.168
- User Name: admin
- Password: admin
- Set the static IP address for the laptop to be used for programming to the same network IP address as the NetWay5PQ. The default address of the NetWay5PQ is 192.168.168.168, E.I. 192.168.168.200. 2. Connect one end of the network cable to the network jack on the NetWay5PQ and the other to the network connection of the laptop.
- Open a browser on the computer and enter “192.168.168.168” into the address bar. A dialog box Authentication Required will appear requesting both user name and password. Enter the default values here. Click on the button labeled Log In.
- The status page of the NetWay5PQ will appear. Click on the tab labeled Network Settings. This will open the Network Setting screen. In this screen the MAC Address of the NetWay5PQ module will be found along with the Network Settings and Email Settings.
Network Settings:
In the IP Address Method field select the method that the IP Address for the NetWay5PQ will be obtained (STATIC or DHCP), then follow the appropriate steps.
Static:
- IP Address: Enter the IP address assigned to the NetWay5PQ by the network administrator. B. Subnet Mask: Enter the Subnet of the network.
- Gateway: Enter the TCP/IP gateway of the network access point (router) being used. Gateway configuration is required to properly receive emails from the device.
- HTTP Port: Enter the HTTP port number assigned to the NetWay5PQ module by the network administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.
- HTTPS Port: Enter the HTTPS port number assigned to the NetWay5PQ module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access. F. Click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
DHCP:
- After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings. A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK. Next, click on the button labeled Reboot Server. After rebooting the NetWay5PQ will be set in the DHCP mode. The IP address will be assigned by the router when the NetWay5PQ is connected to the network. It is recommended to have the assigned IP Address reserved to ensure continued access (see the network administrator).
- Subnet Mask: When operating in DHCP, the router will assign the subnet mask values. C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used. D. HTTP Port: Enter the HTTP port number assigned to the NetWay5PQ module by the network administrator
to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.
– 8 – NetWay5PQ Series Installation Guide
Secure Network Setup (HTTPS):
In order to setup HTTPS for a Secure Network Connection, a Valid Certificate and Key must be used. Certificates and Key should be in a “.PEM” format. Self Certifications should only be used for testing purposes as no actual authentication is being performed. In a Self-Certified mode, the connection will still state that it is unsecure. How to upload Certificate and Key to setup HTTPS:
- Open Tab Labeled “Security”
- Select Tab Labeled “Email/SSL”
- Scroll to bottom under “SSL Settings”
- Click “Select Certificate”
- Browse and select valid Certificate to upload from server
- Click “Select Key”
- Browse and select valid Key to upload from server
- Click “Submit Files”
Once the Certificate and Key is uploaded successfully you can proceed with setting up HTTPS in Network Settings. A. HTTPS Port: Enter the HTTPS port number assigned to the NetWay5PQ module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access. B. Click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
Factory Reset Option:
- Power the unit down. Allow approximately 30 seconds for the unit to power down completely. 2. Depress Factory Reset button on NetWay5PQB while reapplying power to the unit (Fig. 1d, pg. 3). Continue holding the button until the LEDs on board go through the start up cycle, then release the button. 3. The unit returns to the original factory settings.
NetWay5PQ Series Installation Guide – 9 –
VLans
VLans (Virtual Local Area Networks) are a subnetwork that allow for the grouping together of devices for improved network traffic as well as providing higher security by allowing greater control over which devices have access to each other. It is important to plan how you will setup your devices for each vLan.
Configuring vLan on the Altronix Netway5PQ Series Switch: 1. Ensure Laptop or PC being used to program the vLan settings is on a port that will be assigned to your first vLan configuration. By default the management portion of the software is assigned to vLan-1. CAUTION: Changing VID=1, the industry standard VLAN HOST address to any other VID address should be done with caution and performed only locally, since the change will drop the original HOST connection. Local access then facilitates a physical reconnection to respective port.
Note: Only this vLan network allows access to IP management.
- In Network Section click on VLan Tab.
- Click Add vLan.
- Enter a name for the vLan.
- Enter a vLan ID, i.e. 10, 20, etc. Ensure this vLan ID is associated with a vLan setup on the main switch and that your Laptop or PC being used for programming is on this same ID .
Note: vLan ID could be any value 2-4094.
- Assign vLan QOS (Quality of Service) priority. 0 = Lowest and 7 = Highest
- Pick a Trunk port (Tagged Ports). Trunk ports are typically the main connection for network traffic for each group. They are usually connected to a network switch, WAPs, etc.
- Pick the Access port(s) (Untagged Ports) associated with the vLan. Access Ports are typically used for Cameras, etc. If programming locally, ensure your laptop or PC is connected to one of these ports. 9. Save Configuration.
- Repeat steps 2 – 9 to add another vLan .
If unit is accidently programmed incorrectly and you cannot get into the Netway5PQ series programming, physically moving ports of your PC connected to the main switch to a correct port (when being programmed remotely), or, as a last resort, completing a factory reset locally and reprogramming the unit. 11. Advanced Port Settings:
Unknown VID Packet Forwarding Configuration:
On ingress unknown VID, Foward to a fixed set of ports. By default no forwarding is set. Configuration on Ingress Untagged Traffic:
Trunk Port action for ingress UNTAGGED packets. By default do not drop packets.
Keep Tag on Egress:
Select if you want ACCESS Port to keep the vLan tag when sending egress packets.
By default tags are stripped.
Preferred VLAN Forwarding:
For ACCESS Ports that belong to more than one VLan. Select preferred vLan to forward UNTAGGED ingress packets. By default preferred vLan is the last vLan created.
– 10 – NetWay5PQ Series Installation Guide
Typical VLan Setup:
Fig. 4
USB Port for configuring
Trunk
(i.e. VLan ID 10 and 20)
RJ45 from Host Switch
GND +24V
– +
MASTER RESET
Netway5P
PORT1 PORT2
DATA INPUT
PORT3 PORT4
DATA IN
1000
Netway5PQ
LED2 LED1
LED4 LED3
LED6 LED5
LED8 LED7
LED11 LED10
100
10/100/1000
PORT1
PASS THRU
to next Switch
Altronix Corp.
Brooklyn, NY US
www.altronix.com
PoE
LEDs
PORT2
PORT3
PORT4
(i.e. VLan ID 0 and/or 20)
Example
Example
OR
vLan ID 10 for ports 1-2
vLan ID 20 for ports 3-4
Any Ethernet port can be used for VLan Pass Thru
NetWay5PQ Series Installation Guide – 11 –
Wall Mount Installation
- Place unit at desired location and secure with mounting
screws (not included) (Fig. 5, pg. 12).
Fig. 5
Pole Mounting Using Optional Pole Mount Kit
PMK1 (NetWay5PQWPN and NetWay5PQWP) or PMK2 (NetWay5PQWPX): This installation should be made by qualified service personnel. This product contains no serviceable parts. Pole mount kits are intended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included). 1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 6, pg. 12).
- Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16” hex socket driver (Fig. 7, pg. 12 and Fig. 9, pg. 12).
Fig. 6 Fig. 7 Fig. 8
- Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 9, pg. 12).
- Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (Fig. 9 pg. 12).
- Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 10, pg. 12).
- Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with flat head screwdriver or 5/16” hex socket driver
(Fig. 10, pg. 12).
- Clip excess straps.
Fig. 9
Fig. 10
2” to 8”(50.8mm to 203.2mm) diameter round pole
Fig. 11
5” (127mm) square pole
– 12 – NetWay5PQ Series Installation Guide
NetWay5PQWPN
Mechanical Drawing and Dimensions (H x W x D approx.): 9.5” x 7.32” x 4.92” (241.3mm x 185.9mm x 125mm)
1.38”
(35.1mm) 7.32” (185.9mm) 3.54” (89.9mm)
6.75” (171.5mm)
6.0” (152.4mm)
4.25” (108mm)
9.5” (241.3mm)10-32 X 0.25” (6.4mm)
8.0” (203.2mm)
4 Places
6.27” (159.3mm)
9.32” (236.7mm) 8.75” (222.2mm)
316 Stainless Steel
Padlock Latch Attached
0.375” (9.5mm)
Padlock Eye
304 Stainless Steel Piano Hinge
0.312” (7.9mm) TYP
4 Places
4.0” (101.6mm)
8.75” (222.2mm)
4.92” (125mm)
4.35” (110.5mm)
NetWay5PQ Series Installation Guide – 13 –
NetWay5PQWP
Mechanical Drawing and Dimensions (H x W x D approx.): 13.31” x 11.31” x 5.59” (338.1mm x 287.3mm x 142mm)
12.00” (304.8mm)
13.50” (342.9mm)
FRONT VIEW
11.31” (287.3mm)
13.31” (338.1mm)
FRONT VIEW COVER REMOVED
10.75” (273.1mm)
10.00” (254mm)
8.25” (209.6mm)
10.25” (260.4mm)
10-32 X 0.375” (9.5mm)
BRASS INSERT (X4)
10-32 X 0.25” (6.4mm)
BRASS INSERT (X2)
RIGHT SIDE VIEW
1.61” (40.9mm)3.96” (100.6mm)
12.75” (323.9mm)
END VIEW
STAINLESS STEEL PIANO HINGE
PADLOCK LATCH ATTACHED
WITH RIVETS (Ø 0.375” (9.5mm) PADLOCK EYE) 8.00” (203.2mm)
5.59” (142mm)
Ø 0.32 (8.1mm) MOUNTING HOLE TYP. 4 PLACES
– 14 – NetWay5PQ Series Installation Guide
NetWay5PQWPX
Mechanical Drawing and Dimensions (H x W x D approx.): 17.53” x 15.3” x 6.67” (445.3mm x 388.6mm x 169.4mm)
FRONT VIEW RIGHT SIDE VIEW
15.3” (388.6mm)
17.36” (441 mm)
A A
FRONT VIEW COVER REMOVED
14.54” (369.3mm)
14.00” (355.6mm)
12.23” (310.6mm)
1.67” (42.4mm) 5.00” (127mm)
16.73” (425mm)
316 STAINLESS STEEL PADLOCK LATCH
ATTACHED WITH RIVETS. Ø 0.375 PADLOCK EYE
SECTION A-A
0.125” (3.2mm)
16.00” (406.4mm)
14.25” (362mm)
4.94” (125.5mm)
5.77” (146.6mm)
6.41” (162.8mm)
0.75” (19.1mm)
17.53” (445.3mm)
16.74” (425.2mm)
6.67” (169.4mm)
10-32 X 0.250 BRASS INSERT 4 PLCS.
MOUNTING PLATE
END VIEW
Ø 0.32” (8.1mm)
WALL MOUNTING HOLE X 4 12.00” (304.8mm)
NetWay5PQ Series Installation Guide – 15 –
NetWay5PQX
Mechanical Drawing and Dimensions (H x W x D approx.): 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
1.40”
(35.6mm)
4.85” (123.2mm) 4.85” (123.2mm)
3.25” (82.6mm)
1.40”
(35.6mm)
1.20”
0.75”
1.20” 12.5” (317.5mm)
(30.5mm)0.75”
1.20”
(30.5mm)
1.40”
(35.6mm)
5.10” (129.5mm)
5.10” (129.5mm)
(19.1mm) 13.0” (330.2mm)
(19.1mm) 11.0” (279.4mm) 0.9375” (23.8mm)
0.9375” (23.8mm)
(30.5mm)
1.40”
(35.6mm)
5.10” (129.5mm)
6.5625” (166.7mm)
3.25” (82.6mm) 3.25” (82.6mm)
1.0” (25.4mm)
3.25” (82.6mm)
1.0” 10.5” (266.7mm)
1.0”
(25.4mm)
Altronix is not responsible for any typographical errors.
(25.4mm)
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty
NetWay5PQ Series E10X MEMBER
– 16 – NetWay5PQ Series Installation Guide
NetWay5PQWP Series Outdoor Network Managed PoE Plus Switch
“`html
Specifications:
- Model: NetWay5PQ Series
- Ports: 5
- Power Source: 12 or 24VDC
- Output: Maximum 120W
- Enclosure Ratings: NEMA4/4X, IP66 (Outdoor), NEMA1
(Indoor)
Product Usage Instructions:
Installation Instructions:
Wiring methods shall be in accordance with the National
Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or
Recognized wire suitable for the application. All units should be
installed by trained service personnel.
Installation:
NetWay5PQ:
-
Mount NetWay5PQ in the desired location/enclosure (mounting
hardware included). -
Connect NetWay5PQ to power source and Ethernet devices.
NetWay5PQWPN/NetWay5PQWP/NetWay5PQWPX:
-
Remove backplane from enclosure prior to drilling. Do not
discard hardware. -
Mark and drill desired inlets on the enclosure to facilitate
wiring. Maximum NEMA type 4X rated fittings. -
Secure enclosure with appropriate fasteners compatible with
mounting surface. -
Mount backplane in enclosure with hardware.
FAQ:
Q: What power sources are compatible with the NetWay5PQ
Series?
A: The NetWay5PQ Series can be powered by a UL Listed power
source, a solar panel with nominal 24V output, or a 12VDC/24VDC
source.
Q: How many ports does the NetWay5PQ Series have?
A: The NetWay5PQ Series has a total of 5 ports, including a
network data uplink and four PoE ports for powering IP devices.
“`
Power over the Ethernet
Embedded
TM
NetWay5PQ Series
LINQ Managed 5-Port Hardened PoE+ Switches
Models Include:
NetWay5PQWP
– 5-port Managed Hardened PoE Switch with Power Supply/Charger
– NEMA4/4X, IP66 rated Outdoor enclosure.
NetWay5PQX
– 5-port Managed Hardened PoE Switch with Power Supply/Charger
– NEMA1 rated Indoor enclosure.
NetWay5PQWPX
– 5-port Managed Hardened PoE Switch with Power Supply/Charger
– NEMA4/4X, IP66 rated Outdoor enclosure. – Accommodates up to four (4)
12VDC/4AH batteries.
NetWay5PQWPN
– 5-port Managed Hardened PoE Switch – NEMA4/4X rated outdoor enclosure
NetWay5PQ
– 5-port Managed Hardened PoE Switch – Board Only
Installation Guide
Rev. 012924
More than just power.TM
Installing Company: ___ Service Rep. Name:
Address: _____ Phone #:
Overview:
Altronix Netway5PQ Series are LINQ managed hardened PoE+ switches. They
provide a network data uplink and four (4) PoE ports to power IP devices, such
as PoE access controllers and cameras. Other applications may include solar
power (with NetWay5PQ and NetWay5PQWPN), as well as integrating network door
access systems with video surveillance.
For unmanaged switches see NetWay5P Series.
Features:
Input: · NetWay5PWPQ, NetWay5PWPQX, NetWay5PQX:
120VAC, 60Hz, 2.5A. · NetWay5PQ/NetWay5PQWPN:
12 or 24VDC from a UL Listed power source or a solar panel with nominal 24V
(~12-35V) output. Current draw: 6A @ 24VDC at maximum 120W output.
Output: · Four (4) PoE/PoE+ ports. · IEEE 802.3at (30W) and IEEE 802.3af (15W)
compliant. · Maximum Output Power:
120W at 24VDC/6A. 60W at 12VDC/6A. · Single data uplink port.
Ethernet Ports: · Five (5) 10/100/1000 Mbps ports. · Connectivity: RJ45, auto-
crossover. · Wire type: 4-pair CAT5e or higher structured cable. · Distance:
up to 100m. · Speed: 10/100/1000 Mbps, half/full duplex,
auto negotiation.
LINQ Technology: · Remote network management allows for camera/
device reset and monitoring. · PoE port management via Dashboard
IP management program. · Provides local and/or remote access to critical
information via LAN/WAN. · Email and Windows Dashboard Alert notifications
report real-time diagnostics. · Event log tracks history.
VLAN: · Multiple management VLAN assignment. · 802.1Q Tagged VLAN. · Up to 10
VLAN groups. ID Range 2-4095.
LED Indicators: · Individual PoE On LEDs for each port. · Individual IP Link
status, 100/1000Base-T/active
LEDs for each port.
Environmental: · Operating Ambient Temperature:
30ºC to 70ºC ( 22ºF to 158ºF). · Storage Temperature:
40ºC to 85ºC ( 40ºF to 185ºF). · Humidity: 20 to 85%, non-condensing. ·
Operating Altitude: 304.8 to 2,000m.
Applications: · Allows to power up to four (4) IP devices and
networking of multiple remote devices without the need for running multiple
cables from the main switch/server.
Mechanical: NetWay5PQ: · Dimensions (L x W x D approx.):
5.9″ x 3.6″ x 0.75″ (150mm x 91.4mm x 19mm). NetWay5PQWPN · NEMA 4X, IP66
Rated enclosure for outdoor use. · Dimensions (H x W x D approx.):
9.5″ x 7.32″ x 4.92″ (241.3mm x 185.9mm x 125mm). NetWay5PQWP: · NEMA4/4X,
IP66 Rated enclosure for outdoor use. · Dimensions (H x W x D approx.): 13.31″
x 11.31″ x 5.59″ (338.1mm x 287.3mm x 142mm). NetWay5PQWPX: · NEMA4/4X, IP66
Rated enclosure for outdoor use. · Accommodates four (4) 12VDC/4AH batteries
(48V of backup). · Dimensions (H x W x D approx.): 17.53″ x 15.3″ x 6.67″
(445.3mm x 388.6mm x 169.4mm). NetWay5PQX: · Dimensions (H x W x D approx.):
13.5″ x 13″ x 3.25″ (342.9mm x 330.2mm x 83mm).
– 2 –
NetWay5PQ Series Installation Guide
Fig. 1 – NetWay5PQ Board Configulration
1e
MASTER RESET
1d
DATA INPUT
1b
GND +24V
1a
Netway5P Netway5PQ
PORT1 PORT2 PORT3
LED2
LED4
LED6
LED1
LED3
LED5
Altronix Corp. Brooklyn, NY US
www.altronix.com
PORT4
LED8 LED7
DATA IN
LED11
1000
LED10
100
10/100/1000
PORT3 PORT4
PORT2
PORT1
1c
1c
Fig. 2 – eFlow104NB Board Configuration
1c
1c
2h
DC +
BAT +
L G
N
2a
2g
AC1
AC DC 1 min enable
NC C NO NC C NO
AC FAIL
BAT FAIL
2 hr disable TRIGGER EOL NO GND SUPERVISED RESET
+ AUX –
2b
2c 2d 2e 2f
NetWay5PQ Series Installation Guide
– 3 –
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA
70/ANSI, and with all local codes and authorities having jurisdiction. Wiring
should be UL Listed and/or Recognized wire suitable for the application. All
units should be installed by a trained service personnel.
Installation:
NetWay5PQ: 1. Mount NetWay5PQ in the desired location/enclosure (mounting
hardware included). 2. Connect NetWay5PQ to power source and Ethernet devices:
NetWay5PQ can be powered by a UL Listed 12 or 24VDC power source, e.g.
Altronix eFlow power supply/ charger or a solar panel with nominal 24V
(~12-35V) output. 3. Connect a power source to the [GND +24V] terminals
carefully observing polarity (Fig. 1a, pg. 3). 4. Connect a Data source to the
[Data Input] RJ45 jack (Fig. 1b, pg. 3). 5. Connect Access Control boards,
Altronix LINQ units or other IP devices to the [Port 1 – Port 4] RJ45 jacks
(Fig. 1c, pg. 4). Refer to the corresponding Installation Guides for details.
NetWay5PQWPN/NetWay5PQWP/NetWay5PQWPX: 1. Remove backplane from enclosure
prior to drilling. Do not discard hardware.
Note: Make sure that hardware will not interfere with components of the
circuit board. 2. Mark and drill desired inlets on the enclosure to facilitate
wiring. Maximum NEMA type 4X rated fittings
to be used are 0.5″. Follow manufacturer’s specifications for the appropriate
size opening. Note: Inlets for conduit fittings should only be made on the
bottom of the enclosure. To facilitate wire entry utilize weather-tight NEMA
rated connectors (supplied), bushings, and cable. 3. Clean out the inside of
enclosure before remounting circuit boards/backplane. 4. Mounting NEMA4/4X
rated enclosure (Enclosure Dimensions, pg. 13-15): Wall mount: Mount unit in
desired location. Mark and drill holes to line up with the top and bottom hole
of
the enclosure flange. Secure enclosure with appropriate fasteners (e. g.
screws and anchors; bolts and locking nuts, etc.) that are compatible with
mounting surface and are of sufficient length/construction to ensure a secure
mount (Fig. 5, pg. 12). Pole Mount: Refer to Fig. 6 – 11, pg.12. 5. Mount
backplane in enclosure with hardware.
NetWay5PQX: 1. Mount unit in the desired location. Mark and predrill holes in
the wall to line up with the top two keyholes
in the enclosure. Install two (2) upper fasteners and screws in the wall with
the screw heads protruding. Place the enclosure’s upper keyholes over the two
(2) upper screws; level and secure. Mark the position of the lower two (2)
holes. Remove the enclosure. Drill the lower holes and install two fasteners.
Place the enclosure’s upper keyholes over the two (2) upper screws. Install
the two (2) lower screws and make sure to tighten all screws (Enclosure
Dimensions, pg. 16). Secure enclosure to earth ground.
Power Connection: NetWay5PQWP, NetWay5PQWPX, NetWay5PQX: 1. Connect unswitched
AC power (120VAC 60Hz) to terminals marked [L, N] (Fig. 2a, pg. 3). Green “AC”
LED on
power supply board will turn on. Use 14 AWG or larger for all power
connections. Secure green wire lead to earth ground. Keep power-limited wiring
separate from non power-limited wiring (120VAC 60Hz Input, Battery Wires).
Minimum 0.25″ spacing must be provided. CAUTION: Do not touch exposed metal
parts. Shut branch circuit power before installing or servicing equipment.
There are no user serviceable parts inside. Refer installation and servicing
to qualified service personnel. 2. When the use of stand-by batteries is
desired, they must be lead acid or gel type. If batteries are housed in a
weather-proof enclosure (NetWay5PQWP, NetWay5PQWPX), it must be properly
ventilated. Use Altronix Vent2 kit. Connect battery to terminals marked [ BAT
+] (Fig. 2g, pg. 3). Use two (2) 12VDC batteries connected in series for 24VDC
operation (battery leads included) Use batteries – Casil CL1270 (12V/7AH),
CL12120 (12V/12AH), CL12400 (12V/40AH), CL12650 (12V/65AH) batteries or UL
recognized BAZR2 batteries of an appropriate rating. When batteries are not
used, a loss of AC will result in the loss of the output voltage. 3. Connect
appropriate signaling notification devices to AC FAIL & BAT FAIL (Fig. 2b, pg.
4) supervisory relay outputs.
– 4 –
NetWay5PQ Series Installation Guide
4. To delay AC reporting for 2 hrs. set DIP switch [AC Delay] to OFF position
(Fig. 2c, pg. 3). To delay AC reporting for 1 min. set DIP switch [AC Delay]
to ON position (Fig. 2c, pg. 3). Note: Must be set to ON position for Burglar
Alarm Applications.
5. To enable Fire Alarm Disconnect set DIP switch [Shutdown] to ON position
(Fig. 2c, pg. 3). To disable Fire Alarm Disconnect set DIP switch [Shutdown]
to OFF position (Fig. 2c, pg. 3).
6. Trigger terminals are end of a line resistor supervised (10k ohms).
Opening or shorting trigger terminals will cause [DC] output to shutdown (Fig.
2d, pg. 3).
7. Place a jumper for non-latching FACP. A momentary short on these terminals
resets FACP latching [Trigger EOL Shutdown] (Fig. 2e, pg. 3).
NetWay5PQ, NetWay5PQWPN: 1. Mount NetWay5PQ/NetWay5PQWPN in the desired
enclosure/location (mounting hardware is included). 2. NetWay5PQ/NetWay5PQWPN
can be powered by a UL Listed 12/24VDC power source, e.g. Altronix eFlow
power supply/chargers or a solar panel with nominal 24V (~12-35V) output.
Input/Data Connections: 1. Connect a Data source to the [Data Input] RJ45 jack
(Fig. 1b, pg. 4). 2. Connect Access Control boards, Altronix LINQ units or
other IP devices to the [Port 1 – Port 4] RJ45 jacks
(Fig. 1c, pg. 3). Refer to the corresponding Installation Guides for details.
Terminal and Port Identification: NetWay5PQ PoE+ Switch
Terminal/Port Legend
Function/Description
GND +24V
Connect a 12/24VDC UL Listed power source to these terminals carefully observing polarity. Factory connected to power supply in NetWay5PQWP, NetWay5PQWPX, NetWay5PQX (Fig. 1a, pg. 3)
Data Input
Can be used as a Data Uplink (Fig. 1b, pg. 3).
Port 1 – Port 4
Data and PoE/PoE+ (IEEE 802.3af (15W) and IEEE 802.3at (30W) compliant) ports (Fig. 1c, pg. 3).
Master Reset
Resets NetWay5P/NetWay5PQ to factory settings. See Factory Reset Option, pg. 9 (Fig. 1d, pg. 3).
USB Port
Can be used as an option to configure the Netway5PQ for managed operation (Fig. 1e, pg. 3).
eFlow104NB Power Supply/Charger
Terminal Legend Function/Description
L, N
Connect 120VAC 60Hz to these terminals: L to hot, N to neutral (non power- limited) (Fig. 2a, pg. 3).
DC +
24VDC nominal @ 10A continuous output factory connected to NetWay5PQ (Fig. 2h, pg. 3).
Trigger EOL Supervised
Fire Alarm Interface trigger input from a short or FACP. Trigger inputs can be normally open, normally closed from an FACP output circuit (power-limited input) (Fig. 2d, pg. 3).
NO, GND RESET FACP interface latching or non-latching (power-limited) (Fig. 2e, pg. 3).
+ AUX
Auxiliary Class 2 power-limited output rated @ 1A (unswitched) (Fig. 2f, pg. 3).
AC Fail NC, C, NO
Indicates loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized when AC power is present. Contact rating 1A @ 30VDC (power-limited) (Fig. 2b, pg. 3).
Bat Fail NC, C, NO
Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present. Contact rating 1A @ 30VDC. A removed battery is reported within 5 minutes. Battery reconnection is reported within 1 minute (power-limited) (Fig. 2b, pg. 3).
BAT +
Stand-by battery connections. Maximum charge current 1.54A (non power-limited) (Fig. 2g, pg. 3).
NetWay5PQ Series Installation Guide
– 5 –
Parameter Input Power Requirements Output Indicators
Environmental Conditions
Weights (approx.)
Technical Specifications:
Description
NetWay5PQWP, NetWay5PQWPX, NetWay5PQX: 120VAC, 60Hz, 2.5A. NetWay5PQ/NetWay5PQWPN: 12/24VDC from a UL Listed power source or a solar panel with nominal 24V (~12-35V) output. Current draw: 6A at maximum 120W output.
Four (4) PoE/PoE+ ports. Single data uplink port.
NetWay5PQ: Individual PoE On LEDs for each port. Individual IP Link status,
100/1000Base-T/active LEDs for each port.
eFlow104NB: AC input and DC output LED indicators.
Operating Ambient Temperature: Storage Temperature: Humidity: Operating Altitude:
30ºC to 70ºC ( 22ºF to 158ºF). 40ºC to 85ºC ( 40ºF to 185ºF). 20 to 85%, non-condensing. 304.8 to 2,000m.
Model
Product Weight
Shipping Weight
NetWay5PQWP NetWay5PQWPN NetWay5PQWPX
NetWay5PQX NetWay5PQ
10.5 lb. (4.76 kg) 3.7 lb. (1.68 kg) 15 lb. (6.8 kg) 6.65 lb. (3.02 kg) 0.25 lb. (0.11 kg)
11.9 lb. (5.4 kg) 5 lb. (2.27 kg) 17.5 lb. (7.9kg) 7.55 lb. (3.42kg) 0.75 lb. (0.34 kg)
– 6 –
NetWay5PQ Series Installation Guide
Typical Application:
Fig. 3
12 or 24VDC from UL Listed Power Supply* or
Solar Panel with nominal 24V (~12-35V) output
USB Port for configuring
Data Uplink
GND +24V
MASTER RESET
DATA INPUT
10/100/1000
Netway5P Netway5PQ
PORT1 PORT2 PORT3
LED2
LED4
LED6
LED1
LED3
LED5
Altronix Corp. Brooklyn, NY US
www.altronix.com
PORT4
LED8 LED7
DATA IN
LED11
1000
LED10
100
PoE LEDs
PORT3 PORT4
PORT2
PORT1
To Networked Access Controllers, Devices & Cameras and/or Altronix LINQ Series
Ethernet connections
*NetWay5PQWP, NetWay5PQWPX and NetWay5PQX are factory connected to Power Supply
NetWay5PQ Series Installation Guide
– 7 –
Configuring NetWay5PQ for Network Connection
Please be sure to visit altronix.com for latest firmware and installation
instructions
Factory Default Settings
· IP Address:
192.168.168.168
· User Name:
admin
· Password:
admin
1. Set the static IP address for the laptop to be used for programming to the
same network IP address as the NetWay5PQ. The default address of the NetWay5PQ
is 192.168.168.168, E.I. 192.168.168.200.
2. Connect one end of the network cable to the network jack on the NetWay5PQ
and the other to the network connection of the laptop.
3. Open a browser on the computer and enter “192.168.168.168” into the
address bar. A dialog box Authentication Required will appear requesting both
user name and password. Enter the default values here. Click on the button
labeled Log In.
4. The status page of the NetWay5PQ will appear. Click on the tab labeled
Network Settings. This will open the Network Setting screen. In this screen
the MAC Address of the NetWay5PQ module will be found along with the Network
Settings and Email Settings.
Network Settings:
In the IP Address Method field select the method that the IP Address for the
NetWay5PQ will be obtained (STATIC or DHCP), then follow the appropriate
steps.
Static:
A. IP Address: Enter the IP address assigned to the NetWay5PQ by the network
administrator. B. Subnet Mask: Enter the Subnet of the network. C. Gateway:
Enter the TCP/IP gateway of the network access point (router) being used.
Gateway configuration is required to properly receive emails from the device.
D. HTTP Port: Enter the HTTP port number assigned to the NetWay5PQ module by
the network
administrator to allow remote access and monitoring. The default inbound port
setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be
used for remote access, it is recommended primarily for use with LAN
connections. E. HTTPS Port: Enter the HTTPS port number assigned to the
NetWay5PQ module by the network administrator to allow remote access and
monitoring. The default inbound port setting is 443. Being encrypted and more
secure, HTTPS is highly recommended for remote access. F. Click the button
labeled Submit Network Settings. A dialog box will display “New network
settings will take effect after the server is rebooted”. Click OK.
DHCP:
A. After selecting DHCP in the IP Address Method field click the button
labeled Submit Network Settings. A dialog box will display “New network
settings will take effect after the server is rebooted”. Click OK. Next, click
on the button labeled Reboot Server. After rebooting the NetWay5PQ will be set
in the DHCP mode. The IP address will be assigned by the router when the
NetWay5PQ is connected to the network. It is recommended to have the assigned
IP Address reserved to ensure continued access (see the network
administrator).
B. Subnet Mask: When operating in DHCP, the router will assign the subnet mask
values. C. Gateway: Enter the TCP/IP gateway of the network access point
(router) being used. D. HTTP Port: Enter the HTTP port number assigned to the
NetWay5PQ module by the network administrator
to allow remote access and monitoring. The default inbound port setting is 80.
HTTP is not encrypted and unsecure. Even though HTTP can be used for remote
access, it is recommended primarily for use with LAN connections.
– 8 –
NetWay5PQ Series Installation Guide
Secure Network Setup (HTTPS):
In order to setup HTTPS for a Secure Network Connection, a Valid Certificate
and Key must be used. Certificates and Key should be in a “.PEM” format. Self
Certifications should only be used for testing purposes as no actual
authentication is being performed. In a Self-Certified mode, the connection
will still state that it is unsecure. How to upload Certificate and Key to
setup HTTPS:
1. Open Tab Labeled “Security” 2. Select Tab Labeled “Email/SSL” 3. Scroll to
bottom under “SSL Settings” 4. Click “Select Certificate” 5. Browse and select
valid Certificate to upload from server 6. Click “Select Key” 7. Browse and
select valid Key to upload from server 8. Click “Submit Files” Once the
Certificate and Key is uploaded successfully you can proceed with setting up
HTTPS in Network Settings. A. HTTPS Port: Enter the HTTPS port number assigned
to the NetWay5PQ module by the network
administrator to allow remote access and monitoring. The default inbound port
setting is 443. Being encrypted and more secure, HTTPS is highly recommended
for remote access. B. Click the button labeled Submit Network Settings. A
dialog box will display “New network settings will take effect after the
server is rebooted”. Click OK.
Factory Reset Option:
1. Power the unit down. Allow approximately 30 seconds for the unit to power
down completely. 2. Depress Factory Reset button on NetWay5PQB while
reapplying power to the unit (Fig. 1d, pg. 3).
Continue holding the button until the LEDs on board go through the start up
cycle, then release the button. 3. The unit returns to the original factory
settings.
NetWay5PQ Series Installation Guide
– 9 –
VLans
VLans (Virtual Local Area Networks) are a subnetwork that allow for the
grouping together of devices for improved network traffic as well as providing
higher security by allowing greater control over which devices have access to
each other. It is important to plan how you will setup your devices for each
vLan.
Configuring vLan on the Altronix Netway5PQ Series Switch:
1. Ensure Laptop or PC being used to program the vLan settings is on a port
that will be assigned to your first vLan configuration. By default the
management portion of the software is assigned to vLan-1. CAUTION: Changing
VID=1, the industry standard VLAN HOST address to any other VID address should
be done with caution and performed only locally, since the change will drop
the original HOST connection. Local access then facilitates a physical
reconnection to respective port. Note: Only this vLan network allows access to
IP management.
2. In Network Section click on VLan Tab. 3. Click Add vLan. 4. Enter a name
for the vLan. 5. Enter a vLan ID, i.e. 10, 20, etc. Ensure this vLan ID is
associated with a vLan setup on the main switch
and that your Laptop or PC being used for programming is on this same ID.
Note: vLan ID could be any value 2-4094. 6. Assign vLan QOS (Quality of
Service) priority. 0 = Lowest and 7 = Highest 7. Pick a Trunk port (Tagged
Ports). Trunk ports are typically the main connection for network traffic for
each group. They are usually connected to a network switch, WAPs, etc. 8. Pick
the Access port(s) (Untagged Ports) associated with the vLan. Access Ports are
typically used for Cameras, etc. If programming locally, ensure your laptop or
PC is connected to one of these ports. 9. Save Configuration. 10. Repeat steps
2 – 9 to add another vLan. If unit is accidently programmed incorrectly and
you cannot get into the Netway5PQ series programming, physically moving ports
of your PC connected to the main switch to a correct port (when being
programmed remotely), or, as a last resort, completing a factory reset locally
and reprogramming the unit. 11. Advanced Port Settings: Unknown VID Packet
Forwarding Configuration: On ingress unknown VID, Foward to a fixed set of
ports. By default no forwarding is set. Configuration on Ingress Untagged
Traffic: Trunk Port action for ingress UNTAGGED packets. By default do not
drop packets. Keep Tag on Egress: Select if you want ACCESS Port to keep the
vLan tag when sending egress packets. By default tags are stripped. Preferred
VLAN Forwarding: For ACCESS Ports that belong to more than one VLan. Select
preferred vLan to forward UNTAGGED ingress packets. By default preferred vLan
is the last vLan created.
– 10 –
NetWay5PQ Series Installation Guide
Fig. 4
Typical VLan Setup:
USB Port for configuring
Trunk
RJ45 from
(i.e. VLan ID Host Switch
10 and 20)
GND +24V
MASTER RESET
DATA INPUT
10/100/1000
Netway5P Netway5PQ
PORT1 PORT2 PORT3
LED2
LED4
LED6
LED1
LED3
LED5
Altronix Corp. Brooklyn, NY US
www.altronix.com
PORT4
LED8 LED7
DATA IN
LED11
1000
LED10
100
PoE LEDs
PORT3 PORT4
PORT2
PORT1
PASS THRU
to next Switch (i.e. VLan ID 0 and/or 20)
Example
OR
vLan ID 10
for ports 1-2
Example vLan ID 20 for ports 3-4
Any Ethernet port can be used for VLan Pass Thru
NetWay5PQ Series Installation Guide
– 11 –
Wall Mount Installation
1. Place unit at desired location and secure with mounting screws (not
included) (Fig. 5, pg. 12). Fig. 5
Pole Mounting Using Optional Pole Mount Kit PMK1 (NetWay5PQWPN and
NetWay5PQWP) or PMK2 (NetWay5PQWPX):
This installation should be made by qualified service personnel. This product
contains no serviceable parts. Pole mount kits are intended for use with
Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3
and WP4 enclosures. Brackets are designed for use with the Wormgear Quick
Release Straps (two included). 1. Thread one (1) wormgear quick release strap
through the slots on the back of a mounting bracket (Fig. 6, pg. 12). 2. Once
the desired height of the top Pole Mount bracket is achieved, tighten the
straps down by sliding open
end of the strap through the locking mechanism on the strap, then tighten the
screw with flat head screwdriver or 5/16″ hex socket driver (Fig. 7, pg. 12
and Fig. 9, pg. 12).
Fig. 6
Fig. 7
Fig. 8
3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the
bracket, tightening bolts with a 7/16″ hex socket (Fig. 9, pg. 12).
4. Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket
(Fig. 9 pg. 12).
5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket,
tightening bolts with a 7/16″ hex socket (Fig. 10, pg. 12).
6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking
mechanism on the strap, then tighten screw with flat head screwdriver or 5/16″ hex socket driver
(Fig. 10, pg. 12). 7. Clip excess straps.
Fig. 9
Fig. 10 2″ to 8″(50.8mm to 203.2mm) diameter round pole
Fig. 11 5″ (127mm) square pole
– 12 –
NetWay5PQ Series Installation Guide
NetWay5PQWPN Mechanical Drawing and Dimensions (H x W x D approx.):
9.5″ x 7.32″ x 4.92″ (241.3mm x 185.9mm x 125mm)
7.32″ (185.9mm)
1.38″
3.54″ (89.9mm)
(35.1mm)
9.32″ (236.7mm) 8.75″ (222.2mm)
6.75″ (171.5mm) 6.0″ (152.4mm) 4.25″ (108mm)
10-32 X 0.25″ (6.4mm) 4 Places
6.27″ (159.3mm) 8.75″ (222.2mm)
316 Stainless Steel Padlock Latch Attached
0.375″ (9.5mm) Padlock Eye
304 Stainless Steel Piano Hinge
0.312″ (7.9mm) TYP 4 Places
4.0″ (101.6mm)
4.92″ (125mm)
9.5″ (241.3mm) 8.0″ (203.2mm)
4.35″ (110.5mm)
NetWay5PQ Series Installation Guide
– 13 –
NetWay5PQWP Mechanical Drawing and Dimensions (H x W x D approx.):
13.31″ x 11.31″ x 5.59″ (338.1mm x 287.3mm x 142mm)
FRONT VIEW
RIGHT SIDE VIEW
11.31″ (287.3mm)
3.96″ (100.6mm)
1.61″ (40.9mm)
12.75″ (323.9mm)
13.31″ (338.1mm)
13.50″ (342.9mm) 12.00″ (304.8mm)
10.25″ (260.4mm) 5.59″ (142mm)
FRONT VIEW COVER REMOVED
10.75″ (273.1mm) 10.00″ (254mm) 8.25″ (209.6mm)
END VIEW
STAINLESS STEEL PIANO HINGE
10-32 X 0.375″ (9.5mm) BRASS INSERT (X4)
PADLOCK LATCH ATTACHED WITH RIVETS (Ø 0.375″ (9.5mm) PADLOCK EYE)
8.00″ (203.2mm)
Ø 0.32 (8.1mm) MOUNTING HOLE TYP. 4 PLACES
10-32 X 0.25″ (6.4mm) BRASS INSERT (X2)
– 14 –
NetWay5PQ Series Installation Guide
NetWay5PQWPX Mechanical Drawing and Dimensions (H x W x D approx.):
17.53″ x 15.3″ x 6.67″ (445.3mm x 388.6mm x 169.4mm)
FRONT VIEW
RIGHT SIDE VIEW
15.3″ (388.6mm)
1.67″ (42.4mm)
5.00″ (127mm)
17.36″ (441 mm) 16.73″ (425mm)
17.53″ (445.3mm) 16.00″ (406.4mm)
A
A
FRONT VIEW COVER REMOVED
14.54″ (369.3mm) 14.00″ (355.6mm) 12.23″ (310.6mm)
316 STAINLESS STEEL PADLOCK LATCH ATTACHED WITH RIVETS. Ø 0.375 PADLOCK EYE
SECTION A-A
0.125″ (3.2mm)
14.25″ (362mm) 16.74″ (425.2mm) 6.67″ (169.4mm)
4.94″ (125.5mm) 5.77″ (146.6mm) 6.41″ (162.8mm) 0.75″ (19.1mm)
10-32 X 0.250 BRASS INSERT 4 PLCS.
MOUNTING PLATE
END VIEW
Ø 0.32″ (8.1mm) WALL MOUNTING HOLE X 4
12.00″ (304.8mm)
NetWay5PQ Series Installation Guide
– 15 –
NetWay5PQX Mechanical Drawing and Dimensions (H x W x D approx.):
13.5″ x 13″ x 3.25″ (342.9mm x 330.2mm x 82.6mm)
1.40″ (35.6mm)
4.85″ (123.2mm)
4.85″ (123.2mm)
1.40″ (35.6mm)
1.20″ (30.5mm)
3.25″ (82.6mm)
1.20″ (30.5mm)
1.40″ (35.6mm)
0.75″ (19.1mm)
12.5″ (317.5mm) 11.0″ (279.4mm)
0.75″ (19.1mm)
0.9375″ (23.8mm)
1.20″ (30.5mm)
1.40″ (35.6mm)
5.10″ (129.5mm)
5.10″ (129.5mm)
13.0″ (330.2mm)
6.5625″ (166.7mm)
5.10″ (129.5mm)
3.25″ (82.6mm)
0.9375″ (23.8mm)
3.25″ (82.6mm)
3.25″ (82.6mm)
1.0″ (25.4mm)
1.0″ (25.4mm)
10.5″ (266.7mm)
1.0″ (25.4mm)
Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty
NetWay5PQ Series
E10X
MEMBER
– 16 –
NetWay5PQ Series Installation Guide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>