RONDA H5XXX.A Instructions Cal Owner’s Manual

September 25, 2024
RONDA

H5XXX.A Instructions Cal

Product Information

Specifications:

  • Model: H5XXX.1T
  • Caliber: 2030.D
  • Date Switching Duration: Approximately 1 hour and 15
    minutes

Product Usage Instructions:

Removing Setting Stem:

To remove the setting stem, ensure the watch is in position I.
Carefully detach the stem with caution.

Setting Hands:

To set the hands of the watch:

  1. Activate pushers A and B simultaneously for 2 seconds to rotate
    the Chrono seconds hand once.

  2. Use pusher A to correct the chrono seconds hand position.

  3. Use pusher B to jump to the hour hand.

  4. Adjust the hour hand position using pusher A.

  5. Use pusher B to jump to the minute hand.

  6. Correct the minute hand position with pusher A.

General Instructions:

When mounting the hands, always use supporting screws for secure
attachment. The permitted hand setting strengths are as
follows:

  • Hour and Minute Hands: Standard strength
  • Other Hands: As required for proper alignment

FAQ (Frequently Asked Questions):

Q: Can I remove the setting stem at any position?

A: No, the setting stem can only be removed when the watch is in
position I.

Q: How long does it take to switch the date on the watch?

A: Date switching duration is approximately 1 hour and 15
minutes.

Movement holder Removing setting stem
H5XXX.1T
Movement holder Setting hands H5XXX.A

T2 Instructions

Cal. 2030.D

Fitting dial and hand · Crown in position III · Wind crown forwards, until date changes · Remove working stem · Fit dial · Point all hands towards 12 o’clock · Set time · Zero chronograph hand · Crown in position II · Set date · Crown in position I
Date switching duration:
Zeroing the Chronograph hand A. Activate pusher A and B for 2 seconds at the same time (Chrono seconds hand rotates once) B. Pusher A to correct chrono seconds hand C. Pusher B to jump to hour hand D. Pusher A to correct hand position E. Pusher B to jump to minute hand F. Pusher A to correct hand position

~ 11/4 h

General instructions

Removing the setting stem can only be effected in position I.The use of supporting screws is essential when mounting the hands.

Permitted hand setting strengths: Hr / min. hands: Other hands:

<40N <30N

During quick date correction (setting stem in position II), a date switching speed of 5 d/s must not be exceeded.

This movement contains a rechargeable battery that is charged via the solar cell. Only batteries specified by RONDA may be used. Under no circumstances may a silver oxide battery or any other conventional watch battery be used.

Attention: The movement is equipped with a solar cell on the dial side. Careful handling is therefore essential. Scratches or contact with any liquids can cause irreparable damage to the solar cell. Direct pressure on the plastic ring as well as on the electronics attached to it must be avoided. This can impair or damage the solar function.

DOMVT230

Version: 1.0 Creator: 5166 Validator: 5160

June 2024

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>