ANYID FR5404 RFID UHF IoT Reader Instruction Manual

September 24, 2024
ANYID

FR5404 RFID UHF IoT Reader

“`html

Product Information

Specifications

  • Brand: FR5404 UHF-RFID

  • Manufacturer: AnyID technology(Shanghai) Ltd, Shanghai Puyue
    Information Technology Co., Ltd

  • Model: PYQS20200908002

  • Version: B/0

  • Revision Date: 2023-7-25

Product Description

Product Introduction

The FR5404 UHF-RFID is a reader device designed for reading
electronic tags using Radio Frequency technology.

Product Features and Functions

The device allows for system configuration, installation, and
wiring for RFID tag reading. It complies with FCC rules and safety
regulations for operation.

Product Usage Instructions

Basic Safety Information

Intended Service

The manual covers hardware-related content such as system
configuration, installation, and wiring. For software usage
instructions, refer to the corresponding software manual.

Installation and Startup

Ensure that any changes or modifications not approved by the
responsible party are avoided to maintain user authority to operate
the equipment. Maintain a minimum distance of 20cm between the
device and the body during operation.

General Safety Instructions

Before installation, wiring, or other operations, disconnect all
external power sources to prevent electric shock. Only qualified
personnel should conduct installation and debugging. In case of
irreparable malfunction, cease operation and contact the
after-sales maintenance department.

User Notice

The device is called a Reader, and the RFID tags are referred to
as electronic tags in this manual. For operation and usage
inquiries, contact the after-sales service department. The company
reserves the right to change product specifications and manual
content without prior notice for product improvement.

Frequently Asked Questions (FAQ)

Q: Can I use this device without reading the manual?

A: It is strongly recommended to read the manual thoroughly
before using the device to ensure proper installation and
operation.

Q: What should I do if the device malfunctions?

A: If the device experiences an irreparable malfunction, stop
operating it immediately and contact the after-sales maintenance
department for assistance.

“`

FR5404 UHF-RFID operating manual

oprerating manual
AnyID technology(shanghai)Ltd

Shanghai Puyue Information Technology Co., Ltd

Faile namePYQS20200908002

~ 1 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Revision record

Oprerating manual

1. Basic safety information …………………………………………………………………………………………………4 1.1. intended service……………………………………………………………………………………………………4 1.2. Installation and startup ………………………………………………………………………………………….4 1.3. General safety instructions…………………………………………………………………………………….5 1.4. User Notice …………………………………………………………………………………………………………5
2. Product description ………………………………………………………………………………………………………..6 2.1. Product Introduction …………………………………………………………………………………………….6 2.2. Product features and functions ……………………………………………………………………………….6
3. Electrical installation………………………………………………………………………………………………………7 3.1. Reader Port Description ………………………………………………………………………………………..7 3.2. COM-Port ……………………………………………………………………………………………………………8 3.3. INPUT …………………………………………………………………………………………………………………9 3.4. OUTPUT………………………………………………………………………………………………………………9
4. Technical Parameter ……………………………………………………………………………………………………..10 4.1. size …………………………………………………………………………………………………………………..10 4.2. Specification parameters ……………………………………………………………………………………..11 4.3. Function indication …………………………………………………………………………………………….12 4.4. Connection line ………………………………………………………………………………………………….12

Faile namePYQS20200908002

~ 2 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Revision record

Oprerating manual

version A/0 B/0

Revision date 2020-09-08 2023-7-25

Revision record

Revision content Prepared/Reviewer Reviewer

Approver

release

Kexiaobao

Qianwenwu Sunchuanqi

Modify Format

Kexiaobao

Qianwenwu Sunchuanqi

Faile namePYQS20200908002

~ 3 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 1

Basic safety information

Oprerating manual

1. Basic safety information
1.1. intended service
This manual records hardware related content such as system configuration, installation, and wiring. For detailed instructions on software usage, please refer to the corresponding software manual.
1.2. Installation and startup
Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Faile namePYQS20200908002

~ 4 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 1

Basic safety information

Oprerating manual

1.3. General safety instructions
Debugging and Inspection When carrying out installation, wiring and other operations, please
make sure to disconnect all external power sources before proceeding, otherwise there is a risk of electric shock. Carefully read the product manual before operation.
authorizing officer
Installation and debugging can only be completed by personnel with sufficient qualifications.
fault
When an irreparable malfunction occurs, please stop operating the equipment and contact the after-sales maintenance department.
1.4. User Notice
The device described in this manual is named “Reader”. The RFID tags described in this manual are named “electronic tags”. If you have any questions about the operation and usage of this
product, please consult the after-sales service department. In order to improve the product, the company reserves the right to
change the product specifications and the content of this manual at any time without prior notice.

Faile namePYQS20200908002

~ 5 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 2

Product description

2. Product description
2.1. Product Introduction

Oprerating manual

2.1

Radio Frequency Port

Communication Port J3

IO Port J1

4×M4 through-hole

IO Port J2

LED

2.2. Product features and functions

Support RS232/RS485/LAN interface communication Support EPCglobal UHFClass1Gn2/ISO18000-6C standard Effective read and write distance of up to 10m (data source:
S9028 circularly polarized antenna, impinj E41b ultra-high frequency tag, no other interference environment at room temperature) Support active and passive detection modes

Faile namePYQS20200908002

~ 6 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 3

Electrical installation

Oprerating manual

3. Electrical installation

3.1. Reader Port Description

IO Port J1/J2

Table 3.1.1 Port J1/J2 defineIO Port

PIN

1

+12V ··· +28V DC

2

IQ_1PNP

3

GND

4

IQ_0PNP

5

PE

Communication Port J3
Table 3.1.2 Port J3 defineCOM
PIN 1 2 3 4 5 6 7 8
Table 3.1.3 Port J3 definePOE
PIN 1 2 3 4 5 6 7 8

DC +12V ··· +28V GND GND B-RS485- TXDRS232 A+RS485+ DC +12V ··· +28V RXDRS232
DC+Model B DC-Model B DC-Model B TD-/DCModel A RD+/DCModel A TD+/DCModel A DC+Model B RD-/DCModel A

Faile namePYQS20200908002

~ 7 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 3

Electrical installation

Table 3.1.4 Port J3 defineLAN PIN 1 2 3 4 5 6 7 8
3.2. COM-Port

VCC GND GND TDRD+ TD+ VCC RD-

Oprerating manual

Iamge 3.2.1 COM-Port

Faile namePYQS20200908002

~ 8 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 3
3.3. INPUT

Electrical installation

Oprerating manual

Voltage of ON Voltage of OFF Response time types LED
3.4. OUTPUT

DC +6V~VCC < DC +2V 5ms Relay or PNP ONbright

Max load Response time LED

OFF-ON ON-OFF

500mA 5ms 5ms ONbright

Faile namePYQS20200908002

~ 9 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 4

Technical Parameter

4. Technical Parameter
4.1. size
accuracymm±0.1mm

Oprerating manual

Image 5.1 size

Faile namePYQS20200908002

~ 10 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 4

Technical Parameter

Oprerating manual

4.2. Specification parameters

Table 4.2.1 Specification parameters

parameters/Model

R5404

R5404E

R5404P

Voltage

+12V ···+28V DC

POE

MAX Power Communication Port

12W RS232&RS485

14W LAN

Type of Port agreement Frequency Port of antenna IO

RMS1223A2&COLADNE(8Pin) RDMSBo29d3b2usRT/RUJ/M45odbus TCP DR90SB229.3020&MLHAz-N928.00MHz DTNBC9 ×4/RJ 45 4DI/DOPNP

RF Power

0~33dBm

RF agreement Identification ranges

EPCglobal UHFClass1Gen2/ISO18000-6C 10m

protection grade

IP67

Temperature of Work Size

-10~+65 200mm×154mm×32mm

Weight

850g

Material

metal

Faile namePYQS20200908002

~ 11 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0

Unit 5

appendix

oprerating manual

4.3. Function indication

Table 4.3.1 Function indication

Function

Status

LED-STA

green

illustrate
· bright :Work · Flicker:Read/Write successfully

LED-LINK LED-ERR LED-ANT

blue red green

· Flicker:communication · bright :Error · Flicker: Work at this port

4.4. Connection line
Table 6-7 M12 A-CODE (5pin-female)

M12-5pin 1 2 3 4 5

single +12V ··· +28V DC IO_1 GND IO_0 PE

function V+ INPUT/OUTPOT VINPUT/OUTPOT PE

color
brown white blue black grey

Faile namePYQS20200908002

~ 12 ~

© Copyright Shanghai Puyue Information Technology Co., Ltd·china

versionB/0