ANYID FR5404 RFID UHF IoT Reader Instruction Manual
- September 24, 2024
- ANYID
Table of Contents
FR5404 RFID UHF IoT Reader
“`html
Product Information
Specifications
-
Brand: FR5404 UHF-RFID
-
Manufacturer: AnyID technology(Shanghai) Ltd, Shanghai Puyue
Information Technology Co., Ltd -
Model: PYQS20200908002
-
Version: B/0
-
Revision Date: 2023-7-25
Product Description
Product Introduction
The FR5404 UHF-RFID is a reader device designed for reading
electronic tags using Radio Frequency technology.
Product Features and Functions
The device allows for system configuration, installation, and
wiring for RFID tag reading. It complies with FCC rules and safety
regulations for operation.
Product Usage Instructions
Basic Safety Information
Intended Service
The manual covers hardware-related content such as system
configuration, installation, and wiring. For software usage
instructions, refer to the corresponding software manual.
Installation and Startup
Ensure that any changes or modifications not approved by the
responsible party are avoided to maintain user authority to operate
the equipment. Maintain a minimum distance of 20cm between the
device and the body during operation.
General Safety Instructions
Before installation, wiring, or other operations, disconnect all
external power sources to prevent electric shock. Only qualified
personnel should conduct installation and debugging. In case of
irreparable malfunction, cease operation and contact the
after-sales maintenance department.
User Notice
The device is called a Reader, and the RFID tags are referred to
as electronic tags in this manual. For operation and usage
inquiries, contact the after-sales service department. The company
reserves the right to change product specifications and manual
content without prior notice for product improvement.
Frequently Asked Questions (FAQ)
Q: Can I use this device without reading the manual?
A: It is strongly recommended to read the manual thoroughly
before using the device to ensure proper installation and
operation.
Q: What should I do if the device malfunctions?
A: If the device experiences an irreparable malfunction, stop
operating it immediately and contact the after-sales maintenance
department for assistance.
“`
FR5404 UHF-RFID operating manual
oprerating manual
AnyID technology(shanghai)Ltd
Shanghai Puyue Information Technology Co., Ltd
Faile namePYQS20200908002
~ 1 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Revision record
Oprerating manual
1. Basic safety information …………………………………………………………………………………………………4 1.1.
intended service……………………………………………………………………………………………………4 1.2. Installation and
startup ………………………………………………………………………………………….4 1.3. General safety
instructions…………………………………………………………………………………….5 1.4. User Notice
…………………………………………………………………………………………………………5
2. Product description ………………………………………………………………………………………………………..6 2.1.
Product Introduction …………………………………………………………………………………………….6 2.2. Product
features and functions ……………………………………………………………………………….6
3. Electrical installation………………………………………………………………………………………………………7 3.1.
Reader Port Description ………………………………………………………………………………………..7 3.2. COM-Port
……………………………………………………………………………………………………………8 3.3. INPUT
…………………………………………………………………………………………………………………9 3.4.
OUTPUT………………………………………………………………………………………………………………9
4. Technical Parameter ……………………………………………………………………………………………………..10 4.1. size
…………………………………………………………………………………………………………………..10 4.2. Specification parameters
……………………………………………………………………………………..11 4.3. Function indication
…………………………………………………………………………………………….12 4.4. Connection line
………………………………………………………………………………………………….12
Faile namePYQS20200908002
~ 2 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Revision record
Oprerating manual
version A/0 B/0
Revision date 2020-09-08 2023-7-25
Revision record
Revision content Prepared/Reviewer Reviewer
Approver
release
Kexiaobao
Qianwenwu Sunchuanqi
Modify Format
Kexiaobao
Qianwenwu Sunchuanqi
Faile namePYQS20200908002
~ 3 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 1
Basic safety information
Oprerating manual
1. Basic safety information
1.1. intended service
This manual records hardware related content such as system configuration,
installation, and wiring. For detailed instructions on software usage, please
refer to the corresponding software manual.
1.2. Installation and startup
Please take attention that changes or modification not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation. This equipment
complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
Faile namePYQS20200908002
~ 4 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 1
Basic safety information
Oprerating manual
1.3. General safety instructions
Debugging and Inspection When carrying out installation, wiring and other
operations, please
make sure to disconnect all external power sources before proceeding,
otherwise there is a risk of electric shock. Carefully read the product manual
before operation.
authorizing officer
Installation and debugging can only be completed by personnel with sufficient
qualifications.
fault
When an irreparable malfunction occurs, please stop operating the equipment
and contact the after-sales maintenance department.
1.4. User Notice
The device described in this manual is named “Reader”. The RFID tags described
in this manual are named “electronic tags”. If you have any questions about
the operation and usage of this
product, please consult the after-sales service department. In order to
improve the product, the company reserves the right to
change the product specifications and the content of this manual at any time
without prior notice.
Faile namePYQS20200908002
~ 5 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 2
Product description
2. Product description
2.1. Product Introduction
Oprerating manual
2.1
Radio Frequency Port
Communication Port J3
IO Port J1
4×M4 through-hole
IO Port J2
LED
2.2. Product features and functions
Support RS232/RS485/LAN interface communication Support EPCglobal
UHFClass1Gn2/ISO18000-6C standard Effective read and write distance of up to
10m (data source:
S9028 circularly polarized antenna, impinj E41b ultra-high frequency tag, no
other interference environment at room temperature) Support active and passive
detection modes
Faile namePYQS20200908002
~ 6 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 3
Electrical installation
Oprerating manual
3. Electrical installation
3.1. Reader Port Description
IO Port J1/J2
Table 3.1.1 Port J1/J2 defineIO Port
PIN
1
+12V ··· +28V DC
2
IQ_1PNP
3
GND
4
IQ_0PNP
5
PE
Communication Port J3
Table 3.1.2 Port J3 defineCOM
PIN 1 2 3 4 5 6 7 8
Table 3.1.3 Port J3 definePOE
PIN 1 2 3 4 5 6 7 8
DC +12V ··· +28V GND GND B-RS485- TXDRS232 A+RS485+ DC +12V ··· +28V RXDRS232
DC+Model B DC-Model B DC-Model B TD-/DCModel A RD+/DCModel A TD+/DCModel A
DC+Model B RD-/DCModel A
Faile namePYQS20200908002
~ 7 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 3
Electrical installation
Table 3.1.4 Port J3 defineLAN PIN 1 2 3 4 5 6 7 8
3.2. COM-Port
VCC GND GND TDRD+ TD+ VCC RD-
Oprerating manual
Iamge 3.2.1 COM-Port
Faile namePYQS20200908002
~ 8 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 3
3.3. INPUT
Electrical installation
Oprerating manual
Voltage of ON Voltage of OFF Response time types LED
3.4. OUTPUT
DC +6V~VCC < DC +2V 5ms Relay or PNP ONbright
Max load Response time LED
OFF-ON ON-OFF
500mA 5ms 5ms ONbright
Faile namePYQS20200908002
~ 9 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 4
Technical Parameter
4. Technical Parameter
4.1. size
accuracymm±0.1mm
Oprerating manual
Image 5.1 size
Faile namePYQS20200908002
~ 10 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 4
Technical Parameter
Oprerating manual
4.2. Specification parameters
Table 4.2.1 Specification parameters
parameters/Model
R5404
R5404E
R5404P
Voltage
+12V ···+28V DC
POE
MAX Power Communication Port
12W RS232&RS485
14W LAN
Type of Port agreement Frequency Port of antenna IO
RMS1223A2&COLADNE(8Pin) RDMSBo29d3b2usRT/RUJ/M45odbus TCP DR90SB229.3020&MLHAz-N928.00MHz DTNBC9 ×4/RJ 45 4DI/DOPNP
RF Power
0~33dBm
RF agreement Identification ranges
EPCglobal UHFClass1Gen2/ISO18000-6C 10m
protection grade
IP67
Temperature of Work Size
-10~+65 200mm×154mm×32mm
Weight
850g
Material
metal
Faile namePYQS20200908002
~ 11 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0
Unit 5
appendix
oprerating manual
4.3. Function indication
Table 4.3.1 Function indication
Function
Status
LED-STA
green
illustrate
· bright :Work · Flicker:Read/Write successfully
LED-LINK LED-ERR LED-ANT
blue red green
· Flicker:communication · bright :Error · Flicker: Work at this port
4.4. Connection line
Table 6-7 M12 A-CODE (5pin-female)
M12-5pin 1 2 3 4 5
single +12V ··· +28V DC IO_1 GND IO_0 PE
function V+ INPUT/OUTPOT VINPUT/OUTPOT PE
color
brown white blue black grey
Faile namePYQS20200908002
~ 12 ~
© Copyright Shanghai Puyue Information Technology Co., Ltd·china
versionB/0