state WATER HEATERS UPVS-18K Electric Tankless Water Heaters Owner’s Manual

September 24, 2024
state WATER HEATERS

state WATER HEATERS UPVS-18K Electric Tankless Water Heaters

state WATER HEATERS UPVS-18K Electric Tankless Water
Heaters

EASY INSTALLATION

  • Compact size perfect for point-of-use applications close to fixtures
  • Mounts easily to the wall
  • No venting required
  • ½” NPT water connection
  • No T&P vale required (check local codes)

WIDE ARRAY OF MODELS AND MODES OF OPERATION

  • 1.75kW – 3.5kW, 120V
  • 3.5kW – 11kW, 240V (208V)
  • 4kW – 11kW, 277V
  • Single Phase, 50/60 Hz
  • Two mode options, easy switching
  • Lavatory mode, default 105°F; temp range 80°F – 149°F
  • Emergency Eye Wash mode, 85°F

ONBOARD SELF-DIAGNOSTICS & TROUBLESHOOTING

  • Onboard self-diagnostics to monitor performance and protect the unit
  • Bright LED display for status updates and making system selections and adjustments
  • Error codes for troubleshooting and faster resolution

HIGHLY EFFICIENT & RELIABLE DESIGN

  • On-demand water heater capable of supplying endless hot water when appropriately sized
  • Ultra-low activation of 0.17 GPM min.
  • Energy efficiency 0.91 UEF or higher
  • Dry-Fire protection to prevent premature element failures
  • Secondary temperature regulation to limit hot water output appropriate for use with hand or eye washing applications
  • Scale detection (Patent Pending) and easy maintenance for extended service life of the heater

CONSTRUCTION

  • Housing – Bayblend® FR3010 plastic, dark gray
  • Chamber Material – Entec Nylon, glass filled
  • Sheathed copper elements for longer life

WARRANTY

  • 5-Year limited warranty on chambers
  • 1-Year limited warranty on all parts
  • For complete information, consult the written warranty or go to statewaterheaters.com

Model Number| Total Input Wattage (kW)| Voltage (V)| Total Current Draw (Amps)| Recommended U.S. Circuit Breaker Size (Amps)| Conductor Size (AWG)| Activation GPM
---|---|---|---|---|---|---
UPVS-18K| 1.75| 120| 14.58| 15| 14| 0.17
UPVS-24K| 2.40| 120| 20.00| 20| 12| 0.17
UPVS-30K| 3.00| 120| 25.00| 25| 10| 0.17
UPVS-35K| 3.50| 120| 29.17| 30| 10| 0.17
UPVS-35E| 3.50| 240+| 14.58| 15| 14| 0.17
UPVS-45E| 4.50| 240+| 18.75| 20| 12| 0.17
UPVS-55E| 5.50| 240+| 22.92| 25| 10| 0.17
UPVS-70E| 7.00| 240+| 29.17| 30| 10| 0.17
UPVS-90E| 9.00| 240+| 37.50| 40| 8| 0.17
UPVS-110E| 11.00| 240+| 45.83| 50| 8| 0.17
UPVS-40Y| 4.00| 277| 14.44| 15| 14| 0.17
UPVS-55Y| 5.00| 277| 19.86| 20| 12| 0.17
UPVS-80Y| 8.00| 277| 28.88| 30| 10| 0.17
UPVS-110Y| 11.00| 277| 39.71| 40| 8| 0.17

Copper conductors only. All wiring/conductors must be rated for 90°C or greater.
+ This model may be connected to a 208 VAC supply with reduced power output. Connection to 208 VAC may require different breaker and/or wire size than shown in the table.
NOTICE : Incoming line voltage variations may result in nuisance breaker trips. Contact Technical Support if there are multiple breaker trips when the recommended breaker size is in use.

Volts kW GPM AT TEMPERATURE RISE
25°F 30°F 35°F
60°F 65°F 70°F
120V 1.75kW 0.47
0.17
2.4kW 0.64 0.54

0.19
3kW| 0.80| 0.67| 0.57| 0.50| 0.45| 0.40| 0.36| 0.33| 0.31| 0.29| 0.27| 0.25| 0.24
3.5kW| 0.94| 0.78| 0.67| 0.59| 0.52| 0.47| 0.43| 0.39| 0.36| 0.33| 0.31| 0.29| 0.28
240V (208V)| 3.5kW| 0.94| 0.78| 0.67| 0.59| 0.52| 0.47| 0.43| 0.39| 0.36| 0.33| 0.31| 0.29| 0.28
4.5kW| 1.20| 1.00| 0.86| 0.75| 0.67| 0.60| 0.55| 0.50| 0.46| 0.43| 0.40| 0.38| 0.35
5.5kW| 1.47| 1.23| 1.05| 0.92| 0.82| 0.74| 0.67| 0.61| 0.57| 0.53| 0.49| 0.46| 0.43
7kW| 1.87| 1.56| 1.34| 1.17| 1.04| 0.94| 0.85| 0.78| 0.72| 0.67| 0.62| 0.59| 0.55
9kW| 2.41| 2.01| 1.72| 1.50| 1.34| 1.20| 1.09| 1.00| 0.93| 0.86| 0.80| 0.75| 0.71
11kW| 2.94| 2.45| 2.10| 1.84| 1.63| 1.47| 1.34| 1.23| 1.13| 1.05| 0.98| 0.92| 0.87
277V| 4kW| 1.07| 0.89| 0.76| 0.67| 0.59| 0.54| 0.49| 0.45| 0.41| 0.38| 0.36| 0.33| 0.31
5.5kW| 1.47| 1.23| 1.05| 0.92| 0.82| 0.74| 0.67| 0.61| 0.57| 0.53| 0.49| 0.46| 0.43
8kW| 2.14| 1.78| 1.53| 1.34| 1.19| 1.07| 0.97| 0.89| 0.82| 0.76| 0.71| 0.67| 0.63
11kW| 2.94| 2.45| 2.10| 1.84| 1.63| 1.47| 1.34| 1.23| 1.13| 1.05| 0.98| 0.92| 0.87

DIMENSIONS

  • Front View
    Dimensions

  • Side View
    Dimensions

  • Top View
    Dimensions

Models DIMENSIONS – SHIPPING
Width Height
1.75kW – 5.5kW 11.25
7.0kW – 11kW 11.25

Dimensions

ORIENTATION & CLEARANCE

  • All models must be oriented with the inlet and outlet facing upward.
  • Top clearance – a minimum of 12 inches (30.5 cm) to provide access for plumbing connections.
  • Side clearance – a minimum of 8 inches (20.3 cm) to remove the screws and protective cover and to provide access for electrical wires to enter through the side of the unit.
  • Bottom clearance – a minimum of 12 inches (30.5 cm) for access to and maintenance of heating elements. Do not store any items beneath the water heater.
  • Front clearance – a minimum of 8 inches (20.3 cm). In the absence of a door or removable access panel in front of the heater, allow a minimum of 15 inches (38.1 cm) for cover removal and ease of service.
    Orientation & Clearance

Customer Support

© July 2024 State Water Heaters. All Rights Reserved
statewaterheaters.com | 800-365-0024 Toll-Free USA | State Water Heaters | 500 Tennessee Waltz Parkway | Ashland City, TN 37015

Symbols

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals