state WATER HEATERS GTS-240X3 Residential Gas Water Heaters User Guide
- June 5, 2024
- state WATER HEATERS
Table of Contents
- state WATER HEATERS GTS-240X3 Residential Gas Water Heaters
- FEATURES
- ENERGY STAR QUALIFIED DURABLE HEAT EXCHANGER
- QUALIFIED AS LEAD FREE UNDER THE SAFE DRINKING WATER ACT
- INTERNAL FREEZE PROTECTION SYSTEM
- POWER DIRECT VENT DESIGN
- ACCESSORIES
- CONDENSING TANKLESS WITH X3 SCALE PREVENTION TECHNOLOGY
- 240HX3 OUTPUT TEMP VS GPM
- 240HX3 PRESSURE LOSS
- 340HX3 OUTPUT TEMP VS GPM
- 340HX3 PRESSURE LOSS
- 540HX3 OUTPUT TEMP VS GPM
- 540HX3 PRESSURE LOSS
- INDOOR DIMENSIONS
- OUTDOOR DIMENSIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
state WATER HEATERS GTS-240X3 Residential Gas Water Heaters
State has combined water heating and treatment in a product designed to revolutionize tankless water heating. Our new condensing gas tankless line features X3 Technology that extends life on the unit up to three times longer than traditional/unprotected models.
FEATURES
X3 SCALE PREVENTION TECHNOLOGY PATENT PENDING
- No annual descaling required
- No scale buildup means the heater maintains like-new performance longer.
ENERGY STAR QUALIFIED DURABLE HEAT EXCHANGER
- Primary heat exchanger is constructed of a commercial-grade copper that is more resilient to corrosion.
- Copper is 25x better at heat transfer than Stainless Steel, thus stabilizing outgoing water temperatures quicker.
- Secondary heat exchanger is made of 316L Stainless Steel to protect against corrosion.
QUALIFIED AS LEAD FREE UNDER THE SAFE DRINKING WATER ACT
SAFETY FEATURES
- Exhaust & Water Temperature Safety Control
- Overheat Cut Off Fuse
- Air Fuel Ratio (AFR) Sensor
INTERNAL FREEZE PROTECTION SYSTEM
RECIRC CAPABLE
Tankless water heaters with X3 Technology are approved to work with an external recirculation pump and cross-over valve.
POWER DIRECT VENT DESIGN
- Category III or IV venting can be used
- Exhaust, 3 PVC up to 70 4 PVC up to 100.
- Provides flexible venting with PVC, CPVC, polypropylene, or ABS Pipe for Intake and Exhaust solid core only.
ACCESSORIES
- Pipe Cover
- Neutralizer Kit
- X3 Freeze Protection Kit
- Concentric Termination
- Recess Box
WARRANTY
No hardwater exclusions in the industry’s first “peace of mind” limited
warranty 15-year limited warranty on heat exchanger in residential
applications 5-year limited warranty on all parts in residential applications
1-year limited warranty on heat exchanger and parts in commercial
applications. For complete information, consult written warranty or go to
statewaterheaters.com
CONDENSING TANKLESS WITH X3 SCALE PREVENTION TECHNOLOGY
Model Number
| ****
Type
| Gas Consumption Input| Supply Gas Pressure| ****
UEF
| ****
Maximum GPM
| ****
Hot/Cold Connections
| ****
Gas Connection
| Dimensions in Inches| Approx
Shipping Weight lbs
---|---|---|---|---|---|---|---|---|---
Minimum BTU/H| Maximum BTU/H| Minimum in.
W.C
| Maximum in.
W.C
| Height| Width| Depth| Height with Cartridge
Indoor Models
GTS-240X3-NIH| Natural| 15,000| 160,000| 4.0| 10.5| 0.94| 6.6| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 72
GTS-240X3-PIH| Propane| 13,000| 160,000| 8.0| 14.0| 0.94| 6.6| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 72
GTS-340X3-NIH| Natural| 15,000| 180,000| 4.0| 10.5| 0.95| 8| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 72
GTS-340X3-PIH| Propane| 13,000| 180,000| 8.0| 14.0| 0.95| 8| 3/4NPT| 3/4
NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 72
GTS-540X3-NIH| Natural| 15,000| 199,000| 4.0| 10.5| 0.93| 10| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 73
GTS-540X3-PIH| Propane| 13,000| 199,000| 8.0| 14.0| 0.93| 10| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 73
Outdoor Models
GTS-240X3-NEH| Natural| 15,000| 160,000| 4.0| 10.5| 0.95| 6.6| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 71
GTS-240X3-PEH| Propane| 13,000| 160,000| 8.0| 14.0| 0.95| 6.6| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 71
GTS-340X3-NEH| Natural| 15,000| 180,000| 4.0| 10.5| 0.94| 8| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 71
GTS-340X3-PEH| Propane| 13,000| 180,000| 8.0| 14.0| 0.94| 8| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 71
GTS-540X3-NEH| Natural| 15,000| 199,000| 4.0| 10.5| 0.95| 10| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 73
GTS-540X3-PEH| Propane| 13,000| 199,000| 8.0| 14.0| 0.95| 10| 3/4 NPT|
3/4 NPT| 23-5/8| 17-3/4| 11-1/4| 35-9/16| 73
15-150 PSI Water Pressure. 40 PSI or above recommended for maximum flow. Current numbers based on factory testing; 0.5 GPM for activation; 0.4 GPM required for continuous fire after initial ignition. Indoor models are certified from sea level to 10,100 ft. elevations. Outdoor models are certified from sea level to 6,000 ft. elevation.
240HX3 OUTPUT TEMP VS GPM
240HX3 PRESSURE LOSS
340HX3 OUTPUT TEMP VS GPM
340HX3 PRESSURE LOSS
540HX3 OUTPUT TEMP VS GPM
540HX3 PRESSURE LOSS
INDOOR DIMENSIONS
FRONT
SIDE
TOP
BOTTOM
OUTDOOR DIMENSIONS
FRONT
SIDE
TOP
BOTTOM
SUGGESTED SPECIFICATION FOR GTS 540X3-NIH OR GTSb540X3 NEH
The fully modulating, on-demand, condensing gas fired tankless water heater(s) shall be State Tankless Water Heater model GTS-540X3-NIH or GTS-540X3-NEH, having a maximum input rating of 199,000 Btu/h and available in NG or LP. The heater shall have ¾ in. male NPT water and gas connections. The inlet gas supply pressures shall be 4.0 in. WC min up to 10.5 in. WC max for NG and 8.0 in. WC min up to 14 in. WC (max.) for LP. The water heater shall have the integrated X3 Scale Prevention Technology to prevent scaling of the heat exchangers. The indoor heater shall incorporate an integrated temperature controller that will provide diagnostic information, fault history, and heater set temperature. The outdoor heater shall be factory supplied with a temperature remote, 100209924, that can be installed up to 400 ft. from the heater using 20 gauge minimum control wire. The temperature remote shall provide diagnostic information, fault history, and heater set temperature. The heater shall operate using 120 V / 60 Hz power source. The indoor heater will incorporate a factory installed power cord. The indoor heater shall be vented with 3 or 4 diameter schedule 40 PVC solid core CPVC, ABS, polypropylene or category IV vent pipe with a length not to exceed 70 ft equivalent for 3 vent or 100 ft equivalent for 4 vent, terminating horizontally or vertically. The intake pipe may use material such as PVC, CPVC, ABS, aluminum, or Category IV pipe and cannot exceed 70 ft equivalent for 3 vent or 100 ft equivalent for 4 vent. The water heater shall use a commercial grade copper alloy, fin tube primary heat exchanger with quick release brass or bronze waterways. The secondary heat exchanger shall be constructed from stainless steel 316L. The heater shall be controlled by an onboard solid-state printed circuit board which uses the following factory installed components: thermistors to monitor inlet & outlet water temperature and exhaust temperature; a flow sensor to measure flow rate; a flame sensor to monitor combustion; an air-fuel ratio rod to measure and adjust operation in order to maintain optimal combustion efficiency. The heater also consists of inline fusing and surge absorbers for electrical surge protection, an electronic spark igniter, aluminized stainless steel burners, hi limit temperature switches to monitor water and exhaust temperatures, modulating gas valve, an overheat cutoff fuse, ceramic heating blocks to protect the heat exchanger and water piping. The indoor heater shall incorporate auto-fire system for additional freeze protection. The indoor model shall include an exhaust temperature monitoring system using an exhaust thermistor and automatic hi-limit switch to maintain safe exhaust temperatures for sch. 40 PVC. The heater shall have a built in condensate trap for the secondary heat exchanger The heater shall incorporate a condensate drain blockage detector to provide safe operations and prevent overflow. The heater shall be design certified by CSA according to CSA/ANSI Z21.10.3 CSA 4.3, approved for sale in the United States, ENERGY STAR qualified, has a minimum uniform energy factor of 0.93, meets the energy efficiency requirements of the U. S. Department of Energy and ASHRAE 90.1, complies with SCAQMD Rule 1146.2 and other air quality districts with similar requirements for low NOx emissions of 14 ng/J or 20 ppm.