BITMAIN S19e XP Hyd Algorithm With Maximum Hashrate Instruction Manual
- September 24, 2024
- BITMAIN
Table of Contents
BITMAIN S19e XP Hyd Algorithm With Maximum Hashrate
Product Information
Specifications
Product Glance | Value |
---|---|
Model | S19e XP Hyd. |
Sub Version | |
Crypto algorithm/coins | SHA256 |
Typical hashrate, TH/s(1-1) | 251 |
Power on wall @35(1-2), Watt(1-1) | 240 |
Power efficiency on wall@35(1-2), J/T(1-1) | 10 |
Frequently Asked Questions (FAQ)
- Q: What is the recommended coolant for the S19e XP Hyd.?
A: The recommended coolants are Antifreeze, Pure water, or Deionized water based on the specified pH values.
Specification
Product Glance | Value |
---|---|
Model | S19e XP Hyd. |
Sub | 251T |
Version | 10 |
Crypto algorithm/coins | **SHA256 |
Typical hash rate, TH/s (1-1) | 251 |
Power on wall @35℃(1-2), Watt (1-1) | 5522 |
Power efficiency on wall@35℃(1-2), J/T (1-1) | 22 |
Detailed Characteristics
Detailed Characteristics | Value |
---|
Power supply
Phase| 3
Input voltage, Volt (2-1)| 380~415
Input frequency range, Hz| 50~60
Input max current, Amp| 12
Hardware configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (lengthwidthheight, w/o package), mm| 410170209
Server size (lengthwidthheight, with package), mm| 570316430
Net weight, kg| 12.8
Gross weight, kg| 14.1
Environment requirements
Inlet coolant temperature, °C| 20~50
Coolant flow, L/min| 8.0~10.0
Coolant pressure, bar| ≤3.5
Working Coolant (2-2)| Antifreeze/ Pure water/ Deionized water
Coolant pH value| Antifreeze: 7.0~9.0 Prue water: 6.5~7.5
Deionized water : 8.5~9.5
Diameter of Coolant pipe connector, mm| OD10
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%
Notes:
- The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power on wall and power efficiency on wall fluctuate by 5%.
- Inlet coolant temperature.
- Caution: Wrong input voltage may cause server damaged.
- For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!
Performance Curve
- Hashrate vs. Inlet Coolant Temperature.
- Power Efficiency vs. Inlet Coolant Temperature.
- The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by 3%, and the actual power efficiency on wall fluctuate by 5%.