k0-10 Bitcoin Miner Bitmain Instructions

September 24, 2024
BITMAIN

k0-10 Bitcoin Miner Bitmain

“`html

Specifications

Product Glance Value
Model S19 XP Hyd.
Version k0-10
Crypto algorithm/coins SHA256
Typical hashrate, TH/s(1-1) 257
Power on wall @35(1-2), Watt(1-1) 5346
Power efficiency on wall@35(1-2), J/T(1-1) 20.8

Detailed Characteristics

Value

Power Supply
Phase: 3
Input voltage, Volt(2-1): 380~415
Input frequency range, Hz: 50~60
Input max current, Amp: 12

Environment Requirements

Value

Coolant flow, L/min: 8.0~10.0
Coolant pressure, bar: 3.5

FAQ

Q: What is the recommended input voltage for the S19 XP

Hyd.?

A: The recommended input voltage is in the range of 380~415
Volts.

“`

S19 XP Hyd.
Product Manual
Sep. 2024
BITMAIN TECHNOLOGIES INC. www.bitmain.com

1. Specification

S19 XP Hyd. Product Manual

Product Glance

Value

Model

S19 XP Hyd.

Version

k0-10

Crypto algorithm/coins

SHA256|BTC/BCH/BSV

Typical hashrate, TH/s(1-1) Power on wall @35(1-2), Watt(1-1) Power efficiency on wall@35(1-2), J/T(1-1)

257 5346 20.8

Detailed Characteristics

Value

Power Supply

Phase

3

Input voltage, Volt(2-1)

380~415

Input frequency range, Hz

50~60

Input max current, Amp

12

Hardware Configuration

Network connection mode

RJ45 Ethernet 10/100M

Server size (lengthwidthheight, w/o package), mm

410170209

Server size (lengthwidthheight, with package), mm

570316430

Net weight, kg

12.8

Gross weight, kg

14.1

Environment Requirements

Inlet coolant temperature, °C

20~40

Coolant flow, L/min Coolant pressure, bar Working coolant(2-2)
Coolant pH value Diameter of coolant pipe connector, mm

8.0~10.0 3.5
Antifreeze/ Pure water/Deionized water
Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water8.5~9.5
OD10

Storage temperature, °C

-20~70

Operation humidity(non-condensing), RH

10~90%

Notes:

(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%. (1-2) Inlet coolant temperature. (2-1) Caution: Wrong input voltage may cause server damaged. (2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!