S19k Pro Profitability Asic Miner Hashrate
Product Information
Specifications
Product Glance | Value |
---|---|
Model Version | S19k Pro K1-10 |
Crypto algorithm/coins | SHA256 |
Typical Hashrate, TH/s(1-1) | 120 |
Power on wall @25(1-1), Watt(1-1) | 2760 |
Power efficiency on wall@25(1-2), J/TH(1-1) | 23 |
Detailed Characteristics
Power supply | Value |
---|---|
Power supply AC input voltage, Volt(2-1) | 200~240V AC |
Power supply AC Input Frequency Range, Hz | 50~60 |
Power supply AC Input current, Amp(2-2) | 20 |
Adapted AC output power requirement, W(2-3) | 3600 |
Product Usage Instructions
Working Mode
The S19k Pro has two working modes:
- NEM (Normal Energy Mode):
- Operation temperature: 0~45°C
- Hashrate: 120 TH/s
- Power on wall @25: 2760 Watt
- Power efficiency on wall @25: 23.0 J/TH
- HEM (High Energy Mode):
- Operation temperature: 0~40°C
- Hashrate: 136 TH/s
FAQ (Frequently Asked Questions)
Q: What is the typical power consumption of the S19k Pro in NEM
mode?
A: In NEM mode, the typical power consumption is 2760 Watts.
S19k Pro
Product Manual
Oct. 2023
BITAMIN TECHNOLOGIES INC. www.bitmain.com
1.Specification
Product Glance
Model Version Crypto algorithm/coins Typical Hashrate, TH/s(1-1) Power on wall
@25(1-2), Watt(1-1) Power efficiency on wall@25(1-2), J/TH(1-1)
S19k Pro Product Manual
Value
S19k Pro K1-10
SHA256 | BTC/BCH 120 2760 23
Detailed Characteristics
Value
Power supply
Power supply AC input voltage, Volt(2-1) Power supply AC Input Frequency
Range, Hz Power supply AC Input current, Amp(2-2) Adapted AC output power
requirement, W(2-3)
Hardware Configuration
Network connection mode Server size (LengthWidthHeight, w/o package), mm
Server size (LengthWidthHeight, with package), mm Net weight, kg Gross
weight, kg Noise, dBA @25 (2-4)
Environment Requirements
Operation temperature, Storage temperature, Operation humidity, RH Operation
altitude, m(2-5)
Notes:
200~240V AC 50~60 20 3600
RJ45 Ethernet 10/100M 400195290 570316430 12.85 14.5 72
0~45 -20~70 10%~90% 2000
(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%. (1-2) Inlet air temperature. (2-1) Caution: Wrong input voltage may probably cause server damaged. (2-2) Two AC input wires, 10A per wire. (2-3) Caution: It is strongly recommended that the power on wall of the miner does not exceed this value. (2-4) Max condition: Fan is under max RPM(rotation per minute). (2-5) When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1 for every increase of 300m.
-2-
2. Working Mode
Working mode
Operation temperature, °C
Hashrate, TH/s Power on wall@25, Watt Power efficiency on wall@25, J/TH
Notes:
(3-1) NEM: Normal Energy Mode (3-2) HEM: High Energy Mode
NEM(3-1)
0~45 120 2760 23.0
S19k Pro Product Manual
HEM(3-2)
0~40 136 / /
-3-
2. Performance Curves
(1) Hashrate vs. Ambient Temperature
S19k Pro Product Manual
S19k Pro Hashrate
TH/s
140 120 120 120 120 120 120 120 120 120 120
120
100
80
60
40
20
0
0
10
20
30
40
50
60
Ambient Temperature
(2) J/T vs. Ambient Temperature
S19k Pro J/T
J/T
26.5 26.2
26.0
25.5
25.0
24.6
24.5
24.1
24.0
23.5
23.5 23.0 23.0 23.0 23.0 23.0 23.0 23.0
22.5 0
10
20
30
40
50
60
Ambient Temperature ()