BENDER COM465 series Flexible System Communication
Specifications:
- Flexible system communication for monitoring electrical installations
- Integration of various BUS systems and protocols
- Data transfer via Modbus TCP/RTU, SNMP, PROFIBUS DP, PROFINET,and MQTT
- Residual current monitoring (COM465 series)
- Insulation monitoring in IT systems (CP9…-I series, iso685)
- Power quality monitoring
- Cloud-based long-term analysis and condition monitoring
Product Usage Instructions
System Communication Overview:
The Bender communication solutions offer a flexible system for monitoring
electrical installations. The system allows for fast information exchange and
seamless integration of devices, providing a comprehensive view of your
electrical setup.
Web Interface:
The web interface simplifies the process of checking and setting measured
values, parameters, and other data. It also enables reporting, visualizing
alarms, and creating custom overview pages using the visualization
application.
Integration:
The Bender interfaces support high levels of integration with various BUS
systems and protocols such as Modbus TCP/RTU, SNMP, PROFIBUS DP, PROFINET, and
MQTT. This allows for easy data transfer and communication between devices.
Remote Monitoring and Analysis:
The system enables cloud-based long-term analysis, condition monitoring,
residual current monitoring, insulation monitoring in IT systems, and power
quality monitoring. This ensures continuous monitoring and early detection of
faults for optimal system performance.
FAQ:
How can I access and configure future devices?
Future devices can be configured and read out using the Bender Connect app.
Simply download the app for more information on device configuration.
What are the advantages of the Bender interfaces?
The Bender interfaces offer a high level of integration with various BUS
systems and protocols, allowing for seamless data transfer and communication
between devices. This ensures efficient monitoring and management of
electrical installations.
Flexible system communication
Everything in view
Perfect system overview through fast information exchange and flexible
integration of devices
Keep an eye on the system state of your electrical installation: The
communication solutions from Bender use a condition monitor and can be
integrated into the existing IT structure. This is done via integrated
interfaces and offers the flexibility to integrate third-party devices into
the system along with the Bender devices.
The web interface makes checking and setting measured values, parameters and all other data simple and intuitive. It can be used to report and visualise alarms and to generate individual overview pages using the visualisation application.
Schematic overview
Click on our products for more information.
https://www.bender.de/en/know-how/technology/powerscoutr/
https://www.bender.de/en/products/communication/
https://www.bender.de/en/products/residual-current-monitoring/
https://www.bender.de/en/products/insulation-fault-location/
https://www.bender.de/en/products/power-quality/
Convincing advantages of the Bender interfaces
BMS
BMS stands for Bender measuring device interface. It is an RS-485 interface
with a protocol which has been especially developed for Bender devices. The
BMS bus cyclically transmits alarm and operating messages. In addition, the
protocol contains commands for querying and changing device parameters as well
as various control commands. BMS is a proprietary bus that does not allow any
other communication on the 2-wire line.
BCOM
BCOM is a protocol for the communication of Bender devices via an IP-based
network. Communication is based on standard Ethernet hardware, TCP/IP or
UDP/IP protocol and other standardised network services. The Bender devices
can communicate in parallel with the office communication and use the same
infrastructure. BCOM does not restrict other standard communication on the
same network.
High level of integration
High level of integration of various BUS systems and protocols
https://www.bender.de/en/products/communication/
https://www.bender.de/en/products/residual-current-monitoring/
https://www.bender.de/en/products/current-transformers/linetraxx- ctub100-series/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- rcms460-d/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- rcms150-series/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- mrcdb300-series/
https://www.bender.de/en/products/power-quality/linetraxx-pem353/
https://www.bender.de/en/products/power-quality/energy-meter/
https://www.bender.de/en/products/insulation-monitoring/
https://www.bender.de/en/products/insulation-monitoring/isometer-iso685/
https://www.bender.de/en/products/insulation-fault-location/isoscan-eds440/
https://www.bender.de/en/products/current-transformers/linetraxx-ctac- series/
https://www.bender.de/en/products/communication/bender-connect-app/
https://www.bender.de/en/products/power-quality/
Tip: Future devices can be configured and read out via the Bender Connect app. Click here for more information.
https://www.bender.de/en/products/communication/bender-connect-app/
Multiple communication interfaces
https://www.bender.de/en/know-how/technology/powerscoutr/
https://www.bender.de/en/products/operator-control-panels/comtraxxr-cp9xx- series/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- rcms460-d/
https://www.bender.de/en/products/switching-equipment-and-ips/
https://www.bender.de/en/products/insulation-monitoring/isometer-isomed427/
https://www.bender.de/en/products/operator-control-panels/comtraxx-cp305/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- rcms150-series/
https://www.bender.de/en/products/power-quality/linetraxx-pem353/
https://www.bender.de/en/products/communication/comtraxx-com465ip/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- rcms460-d/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- rcms150-series/
https://www.bender.de/en/products/residual-current-monitoring/linetraxx- mrcdb300-series/
https://www.bender.de/en/products/power-quality/linetraxx-pem353/
https://www.bender.de/en/products/communication/comtraxx-cp9-i-series/
https://www.bender.de/en/products/insulation-fault-location/isoscan-eds440/
https://www.bender.de/en/products/insulation-monitoring/isometer-iso685/
https://www.bender.de/en/products/insulation-fault-location/isoscan-eds440/
We are happy to support you personally at any time in the planning and implementation of your specific system requirements.
https://www.bender.de/en/contact/bender-germany/
POWERSCOUT®
Maximum transparency for your electrical installation
Moisture, deterioration, dirt, mechanical damage or faults due to the impact of current, voltage and temperature cause malfunctions in every electrical installation. The web-based software solution POWERSCOUT® helps you detect these at an early stage and eliminate the causes in an economically reasonable way. This guarantees a high safety level for the installation as well as high operational reliability, and it reduces costs.
Analysis – as individual as your installation – as simple as possible
Predictive maintenance prevents downtimes, reduces costs and staff deployment.
POWERSCOUT® informs you about the condition of your electrical installation at
all times, since the meaningful visualisations with flexible dashboards can be
retrieved via any display device: be it a smartphone, a laptop or a PC. On
request, POWERSCOUT® will send you these graphically processed reports at
specified intervals.
Continuous monitoring
Manual data acquisition is time consuming, error-prone and only provides
random results. POWERSCOUT® gives you an insight into the entire data of your
installation at any time, since all measured values are automatically and
continuously saved. Your data is stored reliably and remains available for
years.
Basis for periodic verification as per IEC 60364-6
The automated POWERSCOUT® report on residual currents forms the basis for
measuring without switch-off by means of periodic verification as per IEC
60364-6. In order to maintain the correct status for electrical installations
and stationary electrical equipment, periodic verification must be carried
out.
This can be ensured, for example, when the installation is monitored continuously by qualified personnel. In this case, it is a smart move to rely on continuous monitoring with multi-channel residual current monitoring systems (RCMS) and an evaluation adapted to the installation (COMTRAXX® series). The automatic POWERSCOUT® reports based on this monitoring make it easier for the qualified person in charge to adjust the times when the insulation test shall be performed as part of the periodic verification.
Analysis
- Continuously recording insulation values
- Recognising correlations and optimising processes
- Cross-plant evaluation options
- Access from any location
- Support for investment decisions
Report
- Historical comparisons
- Reliable storage of measured values
- Event and alarm statistics
Predictive maintenance
- Higher availability
- Continuous monitoring
- Early detection of gradually developing insulation faults
- Early detection and reporting of short-time insulation degradation
- Lower costs incurred due to unexpected malfunctions and shutdowns
Bender GmbH & Co. KG
Londorfer Straße 65
35305 Grünberg
Germany
Tel.: +49 6401 807-0
info@bender.de
www.bender.de
Photos: AdobeStock (© monsit), © MR Vector, © Cobalt,© Ignacio Ferrándiz, ©
suriyapong, © Gorodenkoff
Productions OU, © MclittleStock, © MAJGraphics,© customdesigner), istockphoto
(© hocus-focus,© Kyu Oh) and Bender Archive.
2215de / 04.2024 / © Bender GmbH & Co. KG, Germany – subject to change! The specified standards take into account the version valid at the time of printing.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>