TRILUX LNPLUS Series LED Light Instruction Manual
- September 20, 2024
- TRILUX
Table of Contents
LUMENA PLUS 80
| 90
LNPLUS 80 …
LNPLUS 90 …
MOUNTING INSTRUCTIONS
LNPLUS Series LED Light
For your safety
Read all instructions and mounting steps carefully . Keep the instructions for
maintenanc eordisas sembly work.
Explanation of the warning levels
Observe and follow the warnings. Non-obser vance of the warnings may lead
to injuries or material damage!
WARNING! Indicates dangers which can result in serious and/or fatal
injuries.
CAUTION! indicates dangers which can result in injuries or health hazards.
NOTICE. Indicates dangers which can result in material damage or
malfunctions.
TIP. Indicates information containins advice or a useful note.
Explanation of warning messages and instructional pictograms
WARNING! The electrical connectio A must be carried out by profession-al
personnel who are trained and authorised.
WARNING! The assembly must be carried out by professional personn who are
trained and authorised.
WARNING! Risk of electric shock!
Never work with electrical voltage applied.
WARNING! Risk of electric shock!
The light source of this luminaire shall only be replaced by the man-ufacturer
or a service technician authorised by the manufacturer or a similar qualified
person. If the light source malfunctions or fails, please contact TRILUX.
CAUTION! Risk of eye damage! Do not stare into the active light source.
LED module: risk group 2. Position the luminaire so that looking for a longer
period of time into the luminaire at a distance closer than 0,2 mis not
expected.
Protection against overheating Observe the minimum distance of 0,2 m from
lighted objects.
Safety instructions and safety labels
Electronic control gear units (ECG)
A neutral conductor interruption in the three-phase circuit leads to
overvoltage damage in the lighting system. Only open the neutral conductor
isolating terminal in de-energised state, and close the neutral conductor
isolating terminal before switching on again. Do not exceed the maxi-mum
permissible ambient temperature ta of the luminaire. Exceeding this limit
reduces the service life and in extreme cases there is a risk of premature
failure of the luminaire. De- sign connection cables for the control inputs of
DALI control gear (1-10 V, DALI etc.) to be 230 V mains voltage-proof (basic
insulation).
Connecting cable (Y)
Operate the luminaire only with an undamaged outer cable. To avoid hazards, a
damaged outer cable of this luminaire shall only be replaced by TRILUX, its
service partner or a comparably qualified person.
Load effects
The luminaire meets the require-ments of IEC 60598 and is designed for the
exposure to wind according to EN 1991 (Eurocode) with basic velocity of ≤ 30
m/s (corresponds to wind zone 4 in Germany) in terrain category 1. A snow load
(< 4w kKN/m) and icing (≤ 20 mm) at a mounting height according to the
mounting instructions are taken into account. Impact loads and exposed
locations such as bridges, installation on buildings and installation directly
adjacent to railway tracks are not taken into account.
→ LNPLUS 80 —; LNPLUS 90 —
Load effects
The luminaire meets the require-ments of IEC 60598 and is designed for the
exposure to wind according to EN 1991 (Eurocode) with basic velocity of up to
30 m/s (corresponds to wind zone 4 in Germany) in terrain category 1. A snow
load (≤ 1,6 KN/m’)
and icing (≤ 20 mm) at a mounting height according to the mounting
instructions are taken into account. Impact loads and exposed locations such
as bridges, installation on buildings and in stallation directly adjacent to
railway tracks are not taken into account.
→ LNPLUS 90 (2x) — + 0805 TRAVERSE S2/2 —
2-person installation
TRILUX recommends 2-person installation.
Cover
Operate the Luminaire only with an undamaged cover.
Intended use
Intended for indoor use and covered outdoor use with ambient temperature of:
t, 25 °C
Safety class: I
Protection rating: IP66
Disposal of waste electrical and electronic equipment
Always collect and dispose of old wh electrical and electronic equipment
ames separately at the end of its ser-vice life. In case of doubt, seek
information about environmentally-compliant waste disposal from your local
district authority or special waste disposal companies. Cur-rent information
on the energy efficiency class of the selected product version can be found in
the corresponding data sheet for the luminaire. Instructions for replacing or
removing the light source in accordance with Regulation 2019/2020/EU can be
found at: www.trilux.com/EcoDesign
LUMENA PLUS 80 | 90
Type | ≈ k g |
---|---|
LN PLUS 80 … ETDD | 25 , 6 |
LN PLUS 80 … DMX | 25 , 6 |
LEDC … ETDD | 5,6 |
LEDC … DMX | 5,6 |
Type | ≈ k g |
---|---|
LN PLUS 80 … ETDD | 33 , 1 |
LN PLUS 80 … DMX | 33 , 1 |
LEDC … ETDD | 5,6 |
LEDC … DMX | 5,6 |
|
---|---
|
|
|
|
TRILUX GmbH & Co. KG
Heidestraße
D-59759 Arnsberg
+49 2932 301-0
info@trilux.com
www.trilux.com
10286876
240710
©trilux.com
References
- LED lighting & individual lighting solutions | TRILUX
- LED lighting & individual lighting solutions | TRILUX
- trilux.com/EcoDesign
- trilux.com/manuals
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>