TRILUX 2390 G2 AM9L Optimal Solution For Illuminating Outdoor Areas Instructions

August 21, 2024
TRILUX

TRILUX 2390 G2 AM9L Optimal Solution For Illuminating Outdoor Areas

Product Information

Specifications

  • Model: TRILUX twenty3 2390 G2
  • Protection Rating: IP65
  • Safety Class: I

Product Usage Instructions

Safety Precautions
It is crucial to follow all safety instructions to prevent injuries and material damage:

  • Always have professional personnel handle the electrical connections and assembly.
  • Avoid working with electrical voltage applied to prevent electric shock.
  • Wear clean installation gloves during the mounting process.

Connecting Cable
Operate the luminaire only with an undamaged outer cable. If the outer cable is damaged, it should only be replaced by TRILUX, its service partner, or a qualified person.

Intended Use
The luminaire is suitable for Safety Class I applications with a Protection Rating of IP65. Ensure proper installation and use according to guidelines.

Conformity and Disposal
Dispose of waste electrical and electronic equipment separately at the end of its service life. Check the energy efficiency class and follow regulations for responsible disposal.

Frequently Asked Questions (FAQ)

  • Q: Can I replace the light source myself?
    A: The light source should only be replaced by the manufacturer, a service technician authorized by the manufacturer, or a similar qualified person. Contact TRILUX for assistance if needed.

  • Q: What should I do if the outer cable is damaged?
    A: If the outer cable is damaged, it must be replaced by TRILUX, its service partner, or a comparably qualified person to ensure safety.

WHAT’S INCLUDE

SAFETY INSTRUCTION

For your safety
Read all instructions and mounting steps carefully. Keep the instructions for maintenance or disassembly work.

Explanation of the warning levels
Observe and follow the warnings. Non-observance of the warnings may lead to injuries or material damage!

  • WARNING! Indicates dangers which can result in serious and/or fatal injuries.
  • CAUTION! Indicates dangers which can result in injuries or health hazards.
  • NOTICE. Indicates dangers which can result in material damage or malfunctions.
    TIP. Indicates information containing advice or a useful note.

Explanation of warning messages and instructional pictograms

  • WARNING! The electrical connection must be carried out by professional personnel who are trained and authorised.

  • WARNING! The assembly must be carried out by professional personnel who are trained and authorised.

  • WARNING! Risk of electric shock!
    Never work with electrical voltage applied.

  • WARNING! Risk of electric shock!
    The light source of this luminaire shall only be replaced by the manufacturer or a service technician authorised by the manufacturer or a similar qualified person. If the light source malfunctions or fails, please contact TRILUX.

  • NOTICE. Wear clean installation gloves to prevent soiling.

Safety instructions and safety labels

  • Electronic control gear units (ECG)
    A neutral conductor interruption in the three-phase circuit leads to overvoltage damage in the lighting system. Only open the neutral conductor isolating terminal in a de-energised state, and close the neutral conductor isolating terminal before switching on again. Do not exceed the maximum permissible ambient temperature ta of the luminaire. Exceeding this limit reduces the service life and in extreme cases there is a risk of premature failure of the luminaire. Design connection cables for the control inputs of DALI control gear (1-10 V, DALI etc.) to be 230 V mains voltage-proof (basic insulation).

  • Connecting cable (Y)
    Operate the luminaire only with an undamaged outer cable. To avoid hazards, a damaged outer cable of this luminaire shall only be replaced by TRILUX, its service partner or a comparably qualified person.

  • Load effects
    The luminaire meets the requirements of IEC 60598 and is designed for exposure to wind according to EN 1991 (Eurocode) with basic velocity of ≤ 30 m/s (corresponds to wind zone 4 in Germany) in terrain category 1. A snow load (≤ 1w kN/m²) and icing (≤ 20 mm) at a mounting height according to the mounting instructions are taken into account. Impact loads and exposed locations such as bridges, installation on buildings and installation directly adjacent to railway tracks are not taken into account.

Intended use
Intended for indoor use and covered outdoor use with ambient temperature of: ta 50 °C

  • Safety class: I
  • Protection rating: IP65

DIMENSION

INSTALLATION

MAINTENANCE

Conformity

Directive 2014/53/EU
Simplified EU Declaration of Conformity according to the RED Directive if the luminaire is equipped with a control gear unit with NFC interface or a radio component: TRILUX hereby declares that the radio system type 2390 G2 … complies with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available on the Internet at: www.trilux.com/eu- conformity.

Disposal of waste electrical and electronic equipment
Always collect and dispose of old electrical and electronic equipment separately at the end of its service life. In case of doubt, seek information about environmentally compliant waste disposal from your local district authority or special waste disposal companies. Current information on the energy efficiency class of the selected product version can be found in the corresponding data sheet for the luminaire. Instructions for replacing or removing the light source in accordance with Regulation 2019/2020/EU can be found at: www.trilux.com/EcoDesign

www.trilux.com/manuals

TRILUX GmbH & Co. KG
Heidestraße
D-59759 Arnsberg
+49 2932 301-0
info@trilux.com
www.trilux.com
www.trilux-twenty3.com

10331912 | 240110 | © trilux.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals