TRILUX PW19 Opendo LED Recessed Instruction Manual

June 15, 2024
TRILUX

TRILUX PW19 Opendo LED Recessed
TRILUX PW19 Opendo LED Recessed

For your safety

Read all instructions and mounting steps carefully. Keep the instructions for maintenance or disassembly work.

Explanation of the warning levels

Observe and follow the warnings. Non-observance of the warnings may lead to injuries or material damage!

WARNING! Indicates dangers which can result in serious and/or fatal injuries.

CAUTION! Indicates dangers which can result in injuries or health hazards.

NOTICE. Indicates dangers which can result in material damage or malfunctions.

Explanation of warning messages and instructional pictograms

WARNING! The electrical connection must be carried out by professional personnel who are trained and authorised.

WARNING! The assembly must be carried out by professional personnel who are trained and authorised.

WARNING! Risk of electric shock!
Never work with electrical voltage applied.

WARNING! Risk of electric shock!
The light source of this luminaire shall only be replaced by the manufacturer or a service technician authorised by the manufacturer or a similar qualified person. If the light source malfunctions or fails, please contact TRILUX.

NOTICE. Wear clean installation gloves to prevent soiling.

Safety instructions and safety labels

Electronic control gear units (ECG)
A neutral conductor interruption in the three-phase circuit leads to overvoltage damage in the lighting system.
Only open the neutral conductor isolating terminal in de-energised state, and close the neutral conductor isolating terminal before switching on again. Do not exceed the maximum permissible ambient temperature ta of the luminaire. Exceeding this limit reduces the service life and in extreme cases there is a risk of premature failure of the luminaire. Design connection cables for the control inputs of DALI control gear (1-10 V, DALI etc.) to be 230 V mains voltage-proof (basic insulation).

TouchDim control (··· ETDD)
TouchDim serves to control individual luminaires. The maximum number of permissible electronic control gear units (ECG) for one TouchDim control is max. 20.
The overall cable length (push-button to last luminaire) must not exceed max. 25 m. When using several luminaires with a DALI control or a TouchDim control, TRILUX recommends using a DALI repeater. Otherwise, asynchronisations are possible due to disturbances in the building.

Intended use

Intended for indoor use with a maximum ambient temperature of: ta 25 °C

Safety class: I

Protection rating of connection compartment: IP20
Suitable for further wiring. Max. total current 10 A at 1,5 mm2.

Suitable for further wiring. Max. total current 16 A at 2,5 mm2.

Suitable for mains through-wiring. Max. total current 10 A at 1,5 mm2.

Suitable for mains through-wiring. Max. total current 16 A at 2,5 mm2.

Conformity

Directive 2014/53/EU
Simplified EU Declaration of Conformity according to the RED Directive if the luminaire is equipped with a control gear unit with NFC interface or a radio component:
TRILUX hereby declares that the radio system type Opendo … complies with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available on the Internet at: www.trilux.com/eu- conformity

Disposal of waste electrical and electronic equipment

Always collect and dispose of old electrical and electronic equipment separately at the end of its service life. In case of doubt, seek information about environmentally-compliant waste disposal from your local district authority or special waste disposal companies. Current information on the energy efficiency class of the selected product version can be found in the corresponding data sheet for the luminaire. Instructions for replacing or removing the light source in accordance with Regulation 2019/2020/EU can be found at: www.trilux.com/EcoDesign

Operation

TouchDim function description Osram

  • Funktion: operation

  • Swicth on/off: Short button press (<0.5 s). Note. The luminaire is first switched on with minimum brightness.
    If a setpoint is predefined for brightness control, the brightness is controlles automatically.

  • Dimming: Long button press (0.5 s – 4 s).
    Each repeated long key button press causes a toggle between increased brightness an decreased brightness.
    Note. The brightness control is deactivated until next time the luminaire is switched on.

  • Specifying set value for brightness control: 1. Set the desired brightness. 2. Double-click. Confirmation is given by luminaire flashes.

  • Deactivating brightness control:

    1. Switch of luminaire if necessary
    2. Double-click. Confirmation is given by maximum brightness of the luminaire.

Installations

Installations
Installations
Installations
Installations
Installations
Installations

Assembly

Assembly
Assembly
Assembly
Assembly
Assembly
Assembly
Assembly
Assembly
Assembly
Assembly

TRILUX GmbH & Co. KG

Heidestraße
D-59759 Arnsberg
+49 2932 301-0
info@trilux.com