ReGen8 Duo 2 Person Hemlock Infrared Sauna User Manual

September 15, 2024
ReGen8

ReGen8 logo ReGen8 Duo 2 Person Hemlock Infrared
SaunaReGen 8 Duo – 2 Person
Hemlock Infrared Sauna
USER MANUALhttps://www.lifespanfitness.com.au/pages/product-manuals

Product may vary slightly from the item pictured due to model upgrades.
Read all instructions carefully before using this product. Retain this owner’s manual for future reference.
NOTE:
This manual should not be used to guide your purchasing decision. Your product, and the contents inside its carton, may vary from what is listed in this manual. This manual may also be subject to updates or changes. Updated manuals are available through our website at www.lifespanfitness.com.au

IMPORTANT SAFETY INSTRUCTIONS

For your safety, it is crucial to adhere strictly to the following precautions while using this product:

  1. Ensure that children use the equipment under the supervision of an adult. Avoid playing with the equipment for safety reasons.
  2. Do not insert objects such as fingers or sticks into the heating tube plate to prevent potential dangers.
  3. Never pour water onto the equipment or the heating pipe (board).
  4. Avoid using or storing flammable gases or liquids, such as hair spray, oil paint, gasoline, etc., in proximity to the equipment to prevent fire hazards.
  5. Refrain from placing items inside or on top of the sauna.
  6. Avoid touching the power control panel and any electrical components with wet hands to prevent the risk of electric shock.
  7. It is strictly prohibited to use the equipment during thunderstorms to prevent electric shock.
  8. Do not tilt the equipment and refrain from using sharp objects to strike it.
  9. Shut down the equipment for half an hour after continuous operation for 4 hours.
  10. Avoid operating the equipment in a prolonged high-temperature environment.
  11. Exercise caution when using the equipment after consuming alcohol.
  12. Individuals with hemophilia or a tendency to bleed should avoid using the equipment.
  13. Consult your doctor before using if you are currently experiencing illness or taking medication.
  14. Do not use the equipment immediately after intense exercise; wait until your body temperature returns to normal.
  15. If you experience any discomfort, cease using the equipment immediately.
  16. Mind your head when entering and exiting the equipment.
  17. Do not sleep inside the equipment while it is in operation.
  18. Refrain from using any bath products in the sauna.
  19. Avoid touching the heating element to prevent burns.
  20. Keep the seat timber dry to prevent damage.
  21. Ensure the floor heater remains dry to prevent excessive sweat dripping.

WARNING: Covering the heater or infrared emitter poses a fire risk!
If you have any questions, please contact the supplier.

STRUCTURE OF INFRARED SAUNA

ReGen8 Duo 2 Person Hemlock Infrared Sauna - overview

1. Duster cover
2. Speaker
3. Control box
4. Left board
5. Control panel
6. Front board
7. Handle
8. Door glass
9. Hinge| 10. Ventilation
11. Temperature sensor
12. Top board
13. Back board
14. Heater frame
15. Right board
16. Bench
17. Bench front board
18. Bottom board
---|---

*The structure may vary from different models

INSTALLATION PROCESS

ReGen8 Duo 2 Person Hemlock Infrared Sauna - overview
1* The structure may vary from different models.Due to our continued product improvement, product illustrated on this instruction manual may vary slightly from the actual product.

INSTALLATION PRECAUTIONS

LARGE PLATE ASSEMBLY
Outer buckle installation methodReGen8 Duo 2 Person Hemlock Infrared Sauna -
ASSEMBLY 1Outer buckle installation methodReGen8 Duo 2 Person Hemlock Infrared Sauna - ASSEMBLY
2 ELECTRICAL CONNECTION

ReGen8 Duo 2 Person Hemlock Infrared Sauna - ELECTRICAL
CONNECTION

CONTROL PANEL OPERATION

Control panel operation (A)ReGen8 Duo 2 Person Hemlock Infrared Sauna -
Control panel

  1. Temperature display screen
    For temperature.

  2. Working indicator lamp
    Indicate that the heater is working.

  3. Power indicator lamp
    Indicates that the power supply is on.

  4. Power button
    Touch this key to turn on or turn off it.

  5. Temp control
    Touch the ‘+’ and ‘-‘ button to increase or decrease the temperature from 30°C to 65°C. If the ‘heat’ light is on, the temperature setting will increase one degree every time the ‘+’ button is pushed. If pressed for three seconds, the setting will increase quickly. Decrease the temperature in the same manner by pressing the ‘-‘ button. After the sauna reaches the desired temperature, the ‘heat’ light turns off. The Fahrenheit and Centigrade display can be switched: press the temperature button “+” and “-” at the meantime, then press the button of “light” to switch.

  6. Timer display screen
    For timer.

  7. Light button
    Touch the key  to turn on/off the light.

  8. Time control
    Touch the ‘+’ and ‘-‘ buttons to set the timer from 5 to 60 minutes. If pressed for three seconds, the timer will increase quickly. To extend the sauna session, reset the timer again.

Control panel operation (B)

ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control panel
2

  1. Temperature display screen
    For temperature.

  2. Timer display screen
    For timer.

  3. USB function
    Touch this key to start USB function.

  4. Light button
    Touch the key to turn on/off the light.
    See the next page for details.

  5. Power button
    Press and hold this button to switch on and off.

  6. Temp control
    After heater is turned on, press TEMP- and TEMP+ to adjust the heater temperature. See the next page for details.

  7. Time control
    Touch the ‘+’ and ‘-‘ buttons to set the timer from 5 to 60 minutes. Stepping is 5, when the countdown is to 5 minutes, it will beep 3 times.

  8. Audio function
    See the next page for details.

  9. Button lock function
    Long press LOCK button for 5S, indicator light is on, it means the button is locked. Long press this button again for 5S to unlock the button, indicator lamp is not light.

Light Button:
While the system is in standby mode, press the “LIGHT” button to either turn the lamp on or off separately. If the indicator light is on, it means the lamp is on; if the indicator light is off, it means the lamp is off.
When the high voltage lamp is on, press for 5 seconds (5S), and the time display will show “2n,” while the temperature display shows “Lx” (where x is between 1 and 9).

  1. When it displays “2n,” a short press of the “LIGHT” button changes the LED light color. Pressing it once changes one color.
  2. Within 8 seconds without pressing the “LIGHT” button, the time display exits “2n,” the temperature display exits “Lx,” and the LED lamp retains its current color status, exiting the light control logic lock key function.
  3. You can independently turn on or off the LED light and high voltage lamp. While in the “2n” status, press “TIME-” and “TIME+” separately to control the LED light or high voltage lamp.

Temperature Control:
After turning on the heater, use the “TEMP-” and “TEMP+” buttons to adjust the heater temperature. The temperature range is from 30 to 65°C (75°C), with a stepping temperature of 1°C. The Fahrenheit degree range is from 90 to 150°F (167°F), with a stepping temperature of 5°F.
If the temperature is below 30°C or 90°F, it will display “LO.” To switch between Celsius and Fahrenheit, press “TEMP-” and “LOCK” simultaneously for 5 seconds.
Audio Function:

  1. Press the AUDIO button for the first time, and the indicator light will illuminate. Activate Bluetooth on your mobile device while searching and pairing with the sauna. Once matched (within 6 or 8 seconds), music can be played. The temperature display shows “BLU,” and the time display shows “–Db” or delays for 5 seconds before displaying. Use TIME+ or TIME- to adjust the volume (01-30DB). Short presses of TEMP+- adjust the previous and next music. If the sauna is active and there’s no button press after 8 seconds, the display will show the temperature and time.
    Remarks: During Bluetooth pairing, it is not possible to switch between Bluetooth, USB, and radio simultaneously. The switch time takes 6 or 7 seconds. To switch immediately, wait for 6 or 7 seconds.
    To stabilize and expedite Bluetooth initialization and pairing, within 8 seconds of opening Bluetooth, disable the load turning on or off function.

  2. Press the AUDIO button for the second time, and the indicator light will illuminate. Activate the USB function, and the temperature display shows “USB.” Press TEMP+ to adjust the previous music and TEMP- to adjust the next one. The time display shows “–Db.” Press TIME+- to adjust the volume, and short presses of TEMP+- adjust the previous and next music. If there’s no button press after 8 seconds, the display shows the temperature and time.
    Attention: It takes 3 seconds to read the USB. If not connected to USB, the volume will show 00db.

  3. Press the button for the third time to activate the radio. A broadcast prompt sound will occur, and the frequency will be displayed in the temperature display. The time display shows “VOL.” Press TIME+- to adjust the volume, and press TEMP to adjust the frequency. If there’s no button press after 8 seconds, the display shows the temperature and time.
    Attention: When the radio is on, long-press the AUDIO button to automatically search for the frequency. The frequency range is (87.5MHZ- 108MHZ). To search for the frequency automatically for the first time in a new location, open the radio and then long-press the AUDIO button.

  4. Press the button for the fourth time to turn off the sound function.

Control panel operation (C)

ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control panel
3

  1. Display screen
    For temperature, time, FM.

  2. Power button
    Touch this key to turn on or turn off it.

  3. Light button
    Touch the key to turn on/off the light inside of cabin.

  4. Music button
    Touch this key to adjust bluetooth, MP3 and FM. FM from 85.7-108.0M.

  5. USB function
    Touch this key to start USB function.

  6. USB function
    Press two key for a second will be FM mode. Press key upon the TRACK for last song and key for next one.

  7. Temp control
    Touch the ‘+’ and ‘-‘ button to increase or decrease the temperature. If the ‘heat’ light is on, the temperature setting will increase one degree every time the ‘+’ button is pushed. If pressed for three seconds, the setting will increase quickly. Decrease the temperature in the same manner by pressing the ‘-‘ button. After the sauna reaches the desired temperature, the ‘heat’ light turns off.
    The Fahrenheit and Centigrade display can be switched: press the temperature button “+” and “-” at the meantime, then press the button of “light” to switch.

  8. Time control
    Touch the ‘+’ and ‘-‘ buttons to set the timer from 5 to 90 minutes. If pressed for three seconds, the timer will increase quickly. To extend the sauna session, reset the timer again.

  9. Pause/Play
    When music playing in this mode, this key is for pause or play.

  10. Volume control
    Press ‘+’ and ‘-‘ to increase or decrease volume.

Control panel operation (D)

ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control panel
4

  1. Temperature display screen
    For temperature.

  2. Temperature adjust button
    Press ” ∧” and “∨” to adjust the temperature setting.

  3. Temperature Type
    Press to change the temperature display between °C/°F.

  4. Timer display screen
    For timer display.

  5. Time adjust button
    Press “∧” and “∨” to adjust the timer setting.

  6. Light button
    Press the key to turn on/off the light.

  7. Power Indicator
    Indicates the status of the sauna’s main power.

  8. Work Indicator
    Indicates the working status of the sauna.

  9. Heat Indicator
    Indicates the status of heating function.

  10. Power button
    Press this key to turn on or turn off the sauna.

  11. Work Start/Stop
    Press to control the working functions of the sauna.

Control panel operation (E)

ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control panel
5

  1. Display screen
    For temperature and timer display.

  2. Temperature button
    Press the key to temperature adjustment state.

  3. Light button
    Press the key to turn on/off the light.

  4. Time button
    Press the key to time adjustment state.

  5. Power button
    Press this key to turn on or turn off the sauna.

  6. Adjust button
    Press “∧” and “∨” to adjust the temperature setting and the timer setting.

  7. Temperture type
    Press to change the temperature display between °C/°F.

  8. Pause/Play
    Press to control the working functions of the sauna.

  9. Bluetooth
    Control panel can be connected to devices to play music.

Control box (A)

ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control
box This control box is the control center of the sauna room; it is installed on the top board with input/output connections as below.

  1. Fuse reset
  2. Main power of sauna room
  3. Heaters power output cable (LOAD A–LOAD D)
  4. Lamp power output cable
  5. Heaters power output cable (LOAD E–LOAD F)
  6. 12V output

Temperature sensor connection port Control panel connecting Color lamp power output
Control box (B)ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control box
2 This control box is the control center of the sauna room; it is installed on the top board with input/output connections as below.

  1. Main power of sauna room
  2. Lamp power output cable
  3. Heaters power output cable (LOAD A–LOAD D)
  4. Fuse reset
  5. 12V output

Temperature sensor connection port
Control panel connecting
Antenna
USB output
Color lamp power output
Audio output

Control box (C)

ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control box
3 This control box is the control center of the sauna room; it is installed on the top board with input/output connections as below.

  1. Main power of sauna room
  2. Heaters power output cable(HT1–HT8)
  3. Reading lamp power output cable
  4. Color lamp power output cable(optional)
  5. 12V output
  6. 24V output
  7. If necessary can connect another power box
  8. Temperature sensor connection port
  9. Control panel connecting
  10. Fuse reset

Control box (D)

ReGen8 Duo 2 Person Hemlock Infrared Sauna - Control box
4 This control box is the control center of the sauna room; it is installed on the top board with input/output connections as below.

1. Main Power Main Power of the sauna room
2. Heater Heaters Power output cable( HT1, HT2, HT3, Ht4)
3. Reading Lamp Reading Lamp power output cable
4. Roof Lamp Roof Lamp power output cable (in some models)
5. Color Lamp Color lamp power output cable(optional)
6. Ctrl Control panel connecting
7. CD/Sig Signal cable group
8. Adjust Color adjust
9. Fuse Fuse Reset

The functions of COLOR LAMP and ADJUST are useful only when color lights are set up in the sauna.

MAINTANCE

Before Using:

  1. Please be sure to follow the instruction manual before operations.
  2. Prepare a towel on the seat bench to prevent sweat from dripping onto it, to avoid affecting the quality and beauty of the wood.

After Using:

  1. Please unplug the power plug promptly.
  2. Open the door to let the heat and humid water vapor dissipate, keeping the sauna cabin dry.

Stain on Wood:

  1. Wipe the outer cabin with a wrung wet towel.
  2. Use a small vacuum cleaner to wipe the inner cabin.
  3. Do not use organic solvents such as gasoline, alcohol, etc., to wipe the sauna surface.
  4. Avoid using sharp objects in the sauna cabin to prevent scratching the wood.

Stain on Glass:

  1. Wipe the glass with soft paper.
  2. Stubborn stains can be wiped with a damp cloth, then dried with a dry cloth.
  3. Do not scratch the surface with a sharp object to prevent scratching the glass.

Transportation and Storage:

  1. Avoid water, snow, and intense impact during transportation.
  2. Do not store it in a humid environment.
  3. In the northern climate, which is relatively dry, frequently wipe the product with a wrung wet towel.
  4. In the southern climate, which is relatively humid, ventilate and dry the product frequently.

TROUBLESHOOTING

Number Problems Possible reasons Countermeasure
1 Indicator light for powersupply not working The connector is not connected
properly Check the connector or replace a new one
No power supply input Check the circuit (especially whether there is power

supply input)
Indicator light is broken| Replace the circuitry panel
2| Indicator light for function is not working| The heating indicator light is broken| Replace the relevant control panel
The circuit board or components are broken| Replace the circuit board
The temperature sensor is broken| Check if the connection is loose and replace it
3| Infrared Heater not heating up| The heater is broken| Replace with a new one of the same specifications
The wire junction or the heater’s wire is loosen| Check and plug them in securely
The temperature sensor is broken| Check if junction of the temperature sensor is loosen and replace it
The circuit board of the relay is not work| Replace the circuit board
4| Odor from the sauna| The circuit‘s problems| There is eyewinker around, remove it
Heater’s temperature over high, cut off the power supply and replace it.
Parts on the circuit is broken

Troubleshooting (A)
Applicable to Section A Controller

Number

| Problems| Possible reasons|

Countermeasure

---|---|---|---
1| Indicator light for power supply not working| The connector is not connected properly| Check the connector or replace a new one
No power supply input| Check the circuit (especially whether there is power supply input)
Indicator light is broken| Replace the circuitry panel
2| Indicator light for function is not working| The heating indicator light is broken| Replace the relevant control panel
The circuit board or components are broken| Replace the circuit board
The temperature sensor is broken| Check if the connection is loose and replace it
3| Light is not working| The cable is not well connected| Reconnect
The light source is broken| Replace a new light source
Poor electronic transformer| Replace the electronic transformer
4| The temperature display show “EP”| Temperature sensor problem| Check temperature sensor interface and replace with new temperature probe
5| The temperature display show “H”| The temperature in the sauna room is too high| Turn off the power and wait un- til the temperature in the sauna room drops below 60°C
6| Speaker does not work| The power cable on the top is not connected| Connect the top power cable
Signal cable is not connected or loose| Check and reconnect
Audio device damage| Replace with a new audio device

Troubleshooting (B)
Applicable to Section B Controller

Number Problems Possible reasons Countermeasure
1 Poor display Digital tube quality problem Replace the display panel

Digital tube driver IC is damaged
2| Controller can’t boot| CPU burned out| Replace a new CPU
No power input| Check for power
The controller’s connection is loose| Reconnect the control computer cable
3| Temperature display is not normal| Temperature sensor damaged| Replace temperature sensor
4| Bluetooth is not paired properly| Check if other devices were paired| Disconnect the original paired device
Check if the Bluetooth version is compatible. The system supports version 2.0 or 4.0.| Replace the matching version
Bluetooth driver module is bro- ken| Replace the four-in-one module
5| Radio without sound| Radio module is broken| Replace the four-in-one audio module
Speaker cable is broken or the speaker is broken| Replace the wire or replace the speaker
Motherboard amplifier is broken| Replace the motherboard
6| System Alarm| The screen displays EO and alarms| Sensor disconnection
The screen displays HH and alarms| Sensor disconnection
The screen displays E1 and alarms| Sensor short circuit
7| Stop heating after heating for awhile| The system has overload, over- current protector action| First check if there is an open circuit, if no open circuit, restart current limit protector
Temperature sensor partial overheating| Check why the partial area is overheated

Troubleshooting (C)
Applicable to Section C Controller

Number Problems Possible reasons Countermeasure
1 Light bulb is not working Light bulb is burned out Replace the light bulb
Light bulb wiring is loosen Replace the lamp holder
Problems with electrical control panel Repair or replace it
2 Repair or replace it Power cord is unplug Plug back power cord to outlet
Outlet has no power Check outlet or circuit breaker
Power supply or circuit panel is broken Replace the power supply or related

circuitry board
3| Music Player doesn’t work| Power connector is loose or dam- age| Check connector or replace it
DC power supply is no power to the music player| Check DC power supply wiring or replace the power supply
Music player is defective| Replace the music player
4| Replace the music player| The speaker is broken| Replace with a new one of the same specifications
The speaker wire is loosen| Reconnect the speaker wire
The power indicator light for music player is off| Turn on the switch to start work
5| The temperature display show “Er1”| NTC open circuit, wire is not well connected| Check and well connect
6| The temperature display show “Er2”| NTC open circuit| Change Thermostat
7| The temperature display show “Er3”| Under -15°| Can’t be functional under too low ambient temperature
8| The temperature display show “Er4”| The temperature display show “Er4”| Change Thermostat

Troubleshooting (D)
1. No Heat Coming From Some Of The Heat Emitters:
Solution 1: Check to make sure all the heat emitter cords are properly connected, including the cord to the heat emitter underneath the bench (if applicable). Go to the roof, and also check that the heat emitter cords are properly connected to the cords on the roof and that those cords are properly plugged into the power supply.
Solution 2: If some of the heat emitters are working, and others are not, the non-functioning ones may be damaged. Do not continue to operate. Contact the manufacturer for replacement parts.
Solution 3 : If the heat emitters are not working, but the control panel displays the time and temperature, then the temperature sensor may not be plugged in properly or may be damaged. Turn the control panel off, go to the roof of the sauna, and locate the red and black wires near the air vent towards the rear of the sauna. After locating the wires labeled “TEMP SENSOR” disconnect them. Connect the spare temperature sensor. For testing purposes, insert the “TEMP SENSOR” (just connected) down the vent on the roof so that it is inside the sauna. Then go to the control panel and press the power button. If the heat emitters now generate heat, the “TEMP SENSOR” was the cause of the problem. You may have to wait about five minutes to confirm if the heat emitters are generating heat. Remove the original temperature sensor from its hole and replace it with the spare one.
2. Control Panel Malfunctioning
Solution 1: If the control panel turns on but not off, and the displayed numbers flash, the issue may be a connection problem. Go up to the roof and locate the “CTRL” wire harness you connected when the roof was installed onto the sauna room. Disconnect the “CTRL” wire harness, check the pins to make sure they are straight and not bent, and firmly reconnect the “CTRL” wire harness. Attempt to turn the sauna on at the control panel and check to see if the buttons are now responding. Contact the manufacturer for any additional troubleshooting.
Solution 2: If the control panel will not turn off, the power/work/heat lights do not come on, or the temperature and timer buttons do not work, it means the control panel may have been damaged and will need to be replaced. Contact the manufacturer for additional troubleshooting.
3. Sauna Shows Signs of No Power:
Solution 1: There could be one of a few problems causing this. First, check to see if the cord from the power supply is plugged into the wall outlet. Also, check your main circuit breaker to confirm that it has not tripped. Check the power supply on the roof of the sauna to make sure there are no signs of malfunctioning, such as a high temperature, burning odor, or strange sounds.
Also, check to make sure none of the power cords are damaged. If the power supply is malfunctioning or power cords are damaged, unplug the sauna immediately and contact the manufacturer.
Solution 2 : If your sauna is plugged in and you have no power at the control panel, then the power supply may need to be reset. Go to the roof of the sauna and locate the power supply. Press the RESET button to reset the power supply. The RESET button is on the same side of the power supply as all the heater cord connections. Attempt to turn the sauna on at the control panel. Contact the manufacturer for any additional troubleshooting.
Solution 3: There could be damage to the temperature sensor. If your sauna arrived with a spare temperature sensor, turn the control panel off and go to the roof of the sauna and locate the red and black wire near the air vent towards the rear of the sauna. After you have located the red and black wires labeled “TEMP SENSOR,” disconnect them. Connect the spare temperature sensor. For testing purposes, insert the “TEMP SENSOR” (you just connected) down the vent on the roof so that it is now inside the sauna. Then go to the control panel and press the power button.
If the heat emitters now heat, then the temperature sensor was the cause of the problem. You may have to wait about five minutes to confirm if the heat emitters are generating heat. Remove the original temperature sensor from its hole and replace it with the spare one.
Solution 4: Check the wiring harnesses coming from the power supply located on the roof of the sauna. Make sure the wiring harness labeled “CTRL” is connected to the power supply at one end and connected to another wiring harness labeled “CTRL” at the other end. If this wiring harness is not properly connected, then the sauna will show signs of having no power.

WARRANTY

AUSTRALIAN CONSUMER LAW
Many of our products come with a guarantee or warranty from the manufacturer. In addition, they come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage.
You are entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Full details of your consumer rights may be found at www.consumerlaw.gov.au.
Please visit our website to view our full warranty terms and conditions: http://www.lifespanfitness.com.au/warranty-repairs
WARRANTY AND SUPPORT
Any claim against this warranty must be made through your original place of purchase.
Proof of purchase is required before a warranty claim may be processed.
If you have purchased this product from the Official Lifespan Fitness website, please visit https://lifespanfitness.com.au/warranty-form
For support outside of warranty, if you wish to purchase replacement parts or request a repair or service, please visit https://lifespanfitness.com.au /warranty-form and fill in our Repair/Service Request Form or Parts Purchase Form.
Scan this QR code with your device to go to lifespanfitness.com.au/warranty- form            ReGen8 Duo 2
Person Hemlock Infrared Sauna - QR code 1

ReGen8 Duo 2 Person Hemlock Infrared Sauna - logoWWW.LIFESPANFITNESS.COM.AU

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals