Smith s 60 Caspian FF Commercial Fan Owner’s Manual
- September 14, 2024
- Smith s
Table of Contents
Smith s 60 Caspian FF Commercial Fan
- The rear outlet variant can be installed in an adjacent room, or storage cupboard, with the warm air outlets positioned at the rear of the appliance and ducted into the adjacent room such as a sports hall or even a narrow corridor, permitting an obstruction free wall space.
- Caspian fan convectors are both a practical and high quality heating solution for any commercial project.
- Incorporating the latest EC motor technology, which can result in running-cost savings as high as 70%, and with variable speed control as standard, the Caspian delivers heat quickly and quietly. AC motor models are available on request.
- It is possible to have master and slave Caspian fan convectors that integrate the entire range of EC Caspian products. Please contact either our sales team or technical team to ensure that this is correctly specified.
- Caspians are compatible with most types of wet central heating systems, functioning equally efficiently with conventional boilers, biomass technology or ground or air source heat pumps.
- The airflow can be reversed so that the warm air is discharged from the lower vent. Please contact either our sales team or technical team to ensure that the correct inlet/discharge positioning is specified.
- Available with Smart Control and Antibacterial paint.
Product Information
-
Motor
EC (BMS compliant) or AC. -
Finish
Casing: zinc-coated steel 1.2mm .
Polyester powder-coated: white RAL 9010.
Available to special order in any colour and with anti-microbial or antibacterial paint. -
Filter
Class G2, 100% polyester, non-washable. -
Installation
Suitable for two-pipe central heating systems.
Maximum installation height for high or ceiling mounting – 4m to underside.
Pipework access holes on the rear and underside.
Key operated front access panels.
Bleed valve accessible on removal of front casing.
Unit must be earthed. -
Commissioning
Check water is hot enough to activate the low temperature cut-out thermostat. -
Controls
See accessories table. -
Specification
To specify state:
Fan Convector with EC motor (or AC), in 1.2mm zinc coated steel, 660mm high and 595mm, 895mm, 1195mm, 1495mm or 1795mm wide. With variable heat output controller. As Smith’s Caspian FF 60, 90, 120, 150, 180.
Technical Data
Heat output – EC (AC product also available)
Model Reference| Fan Speed| Control Voltage VDC|
40°C MWT| 45°C MWT| 50°C MWT| 55°C MWT|
60°C MWT| 65°C MWT| 70°C MWT| 75°C MWT|
80°C MWT
---|---|---|---|---|---|---|---|---|---|---|---
| Low| 3.8| 0.85| 1.20| 1.55| 1.96| 2.37| 2.78| 3.19| 3.61| 4.02
EC 60| Mid| 4.9| 1.13| 1.62| 2.10| 2.58| 3.06| 3.55| 4.03| 4.51| 5.00
| High| 6.4| 1.47| 2.05| 2.63| 3.21| 3.79| 4.36| 4.94| 5.52| 6.10
| Low| 3.2| 1.98| 2.55| 3.11| 3.67| 4.24| 4.80| 5.37| 5.93| 6.50
EC 90| Mid| 4.6| 2.80| 3.58| 4.36| 5.14| 5.91| 6.69| 7.47| 8.25| 9.03
| High| 6.1| 3.68| 4.65| 5.62| 6.59| 7.55| 8.52| 9.49| 10.46| 11.42
| Low| 3.1| 3.03| 3.61| 4.19| 4.78| 5.36| 5.94| 6.53| 7.11| 7.69
EC 120| Mid| 4.3| 3.91| 4.87| 5.82| 6.78| 7.74| 8.70| 9.65| 10.61| 11.57
| High| 5.5| 4.84| 6.00| 7.17| 8.33| 9.49| 10.66| 11.82| 12.99| 14.15
| Low| 2.9| 3.59| 4.57| 5.55| 6.53| 7.51| 8.49| 9.47| 10.45| 11.44
EC 150| Mid| 4.0| 4.77| 6.10| 7.43| 8.76| 10.08| 11.41| 12.74| 14.07| 15.39
| High| 5.1| 6.47| 7.71| 8.96| 10.21| 11.45| 12.70| 13.94| 15.19| 16.43
| Low| 2.8| 4.69| 5.92| 7.15| 8.39| 9.62| 10.85| 12.08| 13.31| 14.55
EC 180| Mid| 3.9| 4.93| 7.15| 9.38| 11.60| 13.82| 16.05| 18.27| 20.49| 22.72
| High| 4.9| 7.90| 9.74| 11.58| 13.42| 15.27| 17.11| 18.95| 20.79| 22.63
Model Reference| Fan Speed| Air Volume (m 3
/h)| Air Volume (l/s)| Specific Fan Power w/ls|
Power Consumption (W)| NR in typical **room*|
Hydraulic Resistance (KPA)| Nominal Weight (KG)|
Water Capacity (L)**
---|---|---|---|---|---|---|---|---|---
| Low| 201.00| 55.90| 0.14| 8.00| 34.00| 1.38| |
EC 60| Mid| 290.50| 80.75| 0.26| 21.00| 41.50| 1.69| 23.00| 0.92
| High| 380.00| 105.60| 0.32| 34.00| 49.50| 2.00| |
| Low| 297.00| 80.75| 0.20| 16.00| 34.00| 4.70| |
EC 90| Mid| 450.50| 124.38| 0.34| 42.00| 41.50| 5.85| 36.00| 1.50
| High| 604.00| 168.00| 0.40| 68.00| 49.97| 7.00| |
| Low| 419.30| 116.50| 0.14| 16.00| 34.00| 17.78| |
EC 120| Mid| 549.65| 152.68| 0.26| 40.00| 42.00| 20.59| 45.00| 2.08
| High| 680.00| 188.89| 0.34| 64.00| 49.96| 23.40| |
| Low| 459.80| 127.72| 0.17| 22.00| 34.70| 22.23| |
EC 150| Mid| 598.10| 166.14| 0.35| 59.00| 41.50| 29.46| 60.00| 2.58
| High| 736.40| 205.56| 0.47| 96.00| 49.38| 36.69| |
| Low| 542.00| 150.56| 0.19| 29.00| 34.90| 47.83| |
EC 180| Mid| 690.00| 191.67| 0.40| 78.50| 41.50| 60.76| 78.00| 3.18
| High| 838.00| 232.78| 0.55| 128.00| 49.00| 73.70| |
*a typical room is taken as a room with a volume of 173m3 and a reverberation time of 0.8 seconds at 500 Hz with one unit installed, situated against a wall or ceiling (radiating noise in a quarter sphere). No allowance is made for attenuation provided by ceilings, enclosures or ductwork. Outputs based upon testing at EN442: 2014 using mean water temperature and an entering air temperature of 20°C with a 10°C temperature drop between flow and return.
Correction factors
Mean Water Temp °C 45 – 80
Water Temperature drop °C
Entering Air Temperature °C
| 15| 5
1.13
| 10
1.10
| 15
1.07
| 20
1.05
---|---|---|---|---|---
| 18| 1.08| 1.05| 1.02| 0.99
| 20| 1.04| 1.00| 0.95| 0.89
| 25| 0.93| 0.91| 0.89| 0.86
Factors are approximate data based upon a standard coil.
How to Calculate Mean Water Temperature
Ordering Guide
Model | Packed Wt (kg) | AC Codes | EC Codes |
---|---|---|---|
CASPIAN FF 60 | 24 | HPCA23001 | HPCA22001 |
CASPIAN FF 90 | 39 | HPCA23002 | HPCA22002 |
CASPIAN FF 120 | 46 | HPCA23003 | HPCA22003 |
CASPIAN FF 150 | 61 | HPCA23004 | HPCA22004 |
CASPIAN FF 180 | 76 | HPCA23005 | HPCA22005 |
Rear Outlet
CASPIAN FF 60 | 24 | HPCA23006 | HPCA22006 |
---|---|---|---|
CASPIAN FF 90 | 39 | HPCA23007 | HPCA22007 |
CASPIAN FF 120 | 46 | HPCA23008 | HPCA22008 |
CASPIAN FF 150 | 61 | HPCA23009 | HPCA22009 |
CASPIAN FF 180 | 76 | HPCA23010 | HPCA22010 |
Plinths | Product Codes |
---|---|
100mm Black | 100mm White |
White
CASPIAN FF/EXT/SL/TT 60 PLINTH| HACA33077| HACA33087| HACA33082| HACA33092
CASPIAN FF/EXT/SL/TT 90 PLINTH| HACA33078| HACA33088| HACA33083| HACA33093
CASPIAN FF/EXT/SL/TT 120 PLINTH| HACA33079| HACA33089| HACA33084| HACA33094
CASPIAN FF/EXT/SL/TT 150 PLINTH| HACA33080| HACA33090| HACA33085| HACA33095
CASPIAN FF/EXT/SL/TT 180 PLINTH| HACA33081| HACA33091| HACA33086| HACA33096
Accessories| White Steel| Black steel
POWDER-COATED STEEL INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 60)| HACA33048|
HACA33053
POWDER-COATED STEEL INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 90)| HACA33049|
HACA33054
POWDER-COATED STEEL INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 120)| HACA33050|
HACA33055
POWDER-COATED STEEL INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 150)| HACA33051|
HACA33056
POWDER-COATED STEEL INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 180)| HACA33052|
HACA33057
Accessories| Product Codes
ADJUSTABLE STRAIGHT AIR INLET/OUTLET EXTENSION DUCT (TO SUIT EXT & FF RO 60)|
HACA33043
ADJUSTABLE STRAIGHT AIR INLET/OUTLET EXTENSION DUCT (TO SUIT EXT & FF RO 90)|
HACA33044
ADJUSTABLE STRAIGHT AIR INLET/OUTLET EXTENSION DUCT (TO SUIT EXT & FF RO 120)|
HACA33045
ADJUSTABLE STRAIGHT AIR INLET/OUTLET EXTENSION DUCT (TO SUIT EXT & FF RO 150)|
HACA33046
ADJUSTABLE STRAIGHT AIR INLET/OUTLET EXTENSION DUCT (TO SUIT EXT & FF RO 180)|
HACA33047
ANODISED ALUMINIUM INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 60)| HACA33058
ANODISED ALUMINIUM INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 90)| HACA33059
ANODISED ALUMINIUM INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 120)| HACA33060
ANODISED ALUMINIUM INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 150)| HACA33061
ANODISED ALUMINIUM INLET/OUTLET GRILLE (TO SUIT FF & EXT RO 180)| HACA33062
PENCIL PROOF GRILLE INSERT (PAIR TO SUIT FF, SL & UV 60)| HACA33069
PENCIL PROOF GRILLE INSERT (PAIR TO SUIT FF, SL & UV 90)| HACA33070
PENCIL PROOF GRILLE INSERT (PAIR TO SUIT FF, SL & UV 120)| HACA33071
PENCIL PROOF GRILLE INSERT (PAIR TO SUIT FF, SL & UV 150)| HACA33072
PENCIL PROOF GRILLE INSERT (PAIR TO SUIT FF, SL & UV 180)| HACA33073
FLEXIBLE HOSES 22MM PAIR| HAGA95003
ROOM THERMOSTAT HARD WIRED| HAGA95001
ROOM THERMOSTAT TAMPER PROOF| HAGA95004
CASPIAN PROPORTIONAL HEAT OUTPUT CONTROLLER 15°-25° INTEGRAL (EC)| HACA33005
CASPIAN PROPORTIONAL HEAT OUTPUT CONTROLLER 15°-25° REMOTE SENSOR (EC)|
HACA33037
CASPIAN PROPORTIONAL HEAT OUTPUT CONTROLLER 11°-21° INTEGRAL (EC)| HACA33117
CASPIAN PROPORTIONAL HEAT OUTPUT CONTROLLER 11°-21° REMOTE SENSOR (EC)|
HACA33118
BLANK CONFIGURABLE PROPORTIONAL HEAT OUTPUT CONTROLLER (PROGRAMMED AT
FACTORY)| HACA33126
CASPIAN ADJUSTABLE LOW TEMPERATURE CUT-OUT (EC AND AC)| HACA33001
CASPIAN EXTERNAL CONTROL HARNESS (EC)| HACA33004
CASPIAN EC LINKING KIT (MASTER/SLAVE)| HACA33068
CASPIAN REMOTE SWITCHING ON/OFF RELAY (24V AC COIL)| HACA33127
CASPIAN THERMOSTAT (T1) & AUTO-SPEED CONTROL (T2) (AC LOW LEVEL)| HACA33003
CASPIAN THERMOSTAT (T1) (EC & AC LOW LEVEL)| HACA33002
CASPIAN THERMOSTAT (T2) (AC LOW LEVEL)| HACA33036
As part our commitment to continuous improvement Smith’s Environmental Products may change the specifications of its products without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All dimensions are in mm unless otherwise stated. Please visit our website for the most up to date information.
+44 (0) 1245 324 900 | sales@smithsep.co.uk | SmithsEP.co.uk