Thank you for your trust and for choosing this Pure Sine Wave Qoltec Uninterruptible Power Supply (UPS). We are convinced that the product will meet your expectations. This manual will guide you through the installation and use of the device and contains important safety instructions for the operation and proper installation of the UPS. If you have any problems with the machine, please read this manual carefully before calling Customer Service.

IMPORTANT SAFETY INSTRUCTIONS

The UPS has been designed to provide all the necessary safety conditions to protect home appliances and electronic office equipment. If you have any questions, please contact the Technical Service of NTEC sp. z 0.0..

  • In order to avoid any damage to the device, it is recommended to ship it in its original packaging.
  • Steam may form inside the UPS in case of sudden changes in temperature. Wait at least 2 hours before starting it. It is imperative to dry the device before turningit on.
  • After drying, all specified conditions must be adhered toin the technical specification, before connecting to the electric network.
  • Please put all cables in a proper place so that they will not be damaged by users. Before connecting to the mains, carefully read all instructions and warnings in the “BEFORE INSTALLATION” section of this manual.
  • Do not throw any objects into the device.
  • In emergency situations (damage to the housing, front panel, mains connections, flooding with liquid), please turn off the power supply, remove the plug and inform the Technical Service of NTEC sp. z o…
  • Do not connect loads to the device that exceed its power range.
  • When the input distortion is too great, the power supply may not function properly.
  • The cable insulation must be airtight to prevent oxidation of the cable.

INTRODUCTION

50716 and 50719 – 500VA/ 50718 and 50720 – 800VA/ 50717 and 50721 – 1000VA are Uninterruptible Power Supplies designed specifically to maintain the power supply of all home and office electrical appliances in the event of a mains power failure. They feature the latest line interactive technology, CPU- controlled PWM technology and a fully protected modular circuit. It is a reliable source of backup power for all types of receivers.

  • This symbol gives information on points of importance toyour own health and safety, the operation of the UPS and the safety of your data.
  • This symbol contains information, warnings, and other suggestions.

FEATURES:

  • 365 x 24 hours of operation (Long backup period)
    High charging current up to 13A, charging large batteries such as 100Ah or 200Ah in a short time.

  • Pure sine wave output
    Applicable to all types of loads, especially suited to engine loads.

  • Modular CPU-controlled circuit
    Provides accurate output signal and protection.

  • Big colorful display
    The large colour display shows basic information.

  • AVR (automatic voltage regulator) function
    The best solution for places where the mains voltage is very unstable.

  • Heavy-duty transformer and circuit, strong loading ability
    With the high efficiency heavy-duty transformer, and specially designed circuit, with strong loading ability.

  • 3-Stage charging current selector
    It allows the user to connect different batteries depending on the backup time required

  • Full protection
    Overload, overheat, battery over charge/discharge, short circuit protection.

SPECIFICATIONS

The grounding conductor should be selected in terms of current carrying capacity. Use a grounding cable for all ground connections of devices that are connected to the UPS. There is a risk of damage to electrical circuits without proper grounding or grounding without approval.
When installing the UPS, if the wrong specification cable is used, it may be dangerous to the health of the user and the device itself.

The UPS may only be repaired by an Authorized Service Center. Any attempt by the user to open and repair it may be dangerous.
Attaching magnetic data carriers to the power adapter may damage your data.

INSTALLATION

UNPACK AND CHECK
The package includes: UPS, operating instructions, warranty card and 2 wires for connecting the battery.

Please check the rating label/plate to ensure that the UPS is as ordered. Make sure that the housing of the unit is not damaged! If you notice any damage, please contact the seller immediately! Keep the packaging for possible transport.

PLACEMENT
This power supply is intended for indoor use only!

  • Install the UPS in a cool, dry and clean place.
  • Install the UPS in a well-ventilated area, keep a minimum distance of 50 cm between the UPS and the wall.
  • Keep away from unstable ground or sources of excessive vibration.
  • Keep away from windows, dust, moisture and cold places.
  • Keep away from fire and heat sources.
  • Keep away from corrosive gas or fluid.
  • Operating temperature: – 10°C~ +40°C.
  • Operating humidity: 10% ~ 90% (non-condensing).

The expected operating altitude of this UPS is less than 1000m. If the installation site is above 1000m above sea level, the load capacity will be correspondingly lower, as shown in the table below.

Special Precautions:
When the UPS input comes from a generator:

  • a. Output power capacity must be higher than the UPS rating, otherwise the UPS and generator may not work properly.
  • b. Output frequency of generator must be in range from 45 to 65Hz, and waveform must be sine wave, otherwise the UPS and generator may not work properly.

EXTERNAL DESCRIPTION

EXPLANATION OF SYMBOLS IN LED DISPLAY

B. Back view (Model: 50716 and 50719 – 500VA)

B. Back view (Model: 50718 and 50720 – 800VA, 50717 and 50721 – 1000VA)

INSTALLATION OF BATTERY

  • A. Make sure using the correct battery cable. The over-current ability of the battery cable should not be less than the maximum discharging current. Please refer to the below table.
  • B. Please make sure that the battery voltage is correct as specified on the case.
  • C. Disconnect the UPS from mains power completely.
  • D. Connect the negative (-) of battery to the BATTERY TERMINAL “-” of UPS, and positive (+) to the BATTERY TERMINAL”+”.
  • E. Before replacing battery, turn off the UPS and disconnect it from mains power.

This UPS is designed for long-time backup, the connected battery should be at least 20AH because the initial charging current is at least 3A. Smaller battery could be damaged easily.

CONNECTION TO MAINS POWER AND TO LOAD

  • A. Plug the UPS into the wall socket.
  • B. Make sure the loads/appliances are turned off before connection.
  • C. Connect the loads/appliances to the UPS one by one. Make sure the total capacity of connected appliances does not exceed the rated capacity of UPS.

OPERATION

TURN ON THE UPS
Press the POWER SWITCH, The UPS is switched on and deliver output till the UPS gives one beeping sound.
Then switch on the connected appliances one by one. If there are 2 or many appliances, please turn on the biggest appliance at the first, the smallest appliance at the last, according to their rated power.

TURN OFF THE UPS
Turn off the devices one by one, and then press the “SWITCH” button, when you hear one beep, it means that the UPS will turn off.

Even if the output of UPS is turned off, the UPS is still working to charge the battery, the UPS is not totally switched off. To switch it off completely, disconnect the UPS from the mains power.

CHARGING CURRENT SELECTOR

It’s recommended to select the charging current as below:

Wrong selection of the charging current may lead to the damage of battery in charging process!

WORK AS AVR (AUTOMATIC VOLTAGE REGULATOR)
The UPS can work as an AVR when the input range is 147-275V, offering regulated output and overload protection to the connected devices.

MAINTENANCE OF BATTERY

With correct using and maintenance, the life of the battery can last for three to six years, depending on the times of discharging and temperature. So regular check and maintenance are very necessary.

  • A. Charge the battery every three months if you don’t use the UPS for a long time. The charging time should be at least 12 hours.
  • B. If the UPS works continuously in mains mode for more than fours months, please discharge the battery to 50% of rated load, so as to keep the battery be active.
  • C. More details, please refer to the specification of the battery.

ALARM AND PROTECTION

  1. BATTERY MODE ALARM
    The UPS will beep 4 sounds when working from mains mode to battery mode.

  2. BATTERY LOW VOLTAGE ALARM AND SHUT DOWN
    The UPS will beep once every second when battery is in low level. When the battery is near empty, it will beep rapidly and shut down automatically.

  3. OVERHEAT PROTECTION
    When the temperature of transformer winding is exceeding the limitation:

    • At Mains Mode, the UPS will go to bypass mode automatically.
    • At Battery Mode, the UPS will beep rapidly, than shut down automatically.
  4. 0VERLOAD PROTECTION

    • At Mains Mode, the UPS will beep continually until the overload is removed. At Battery Mode, the UPS will beep 60 seconds, then shut down automatically.
  5. SHORT CIRCUIT

    • At Mains Mode, the circuit breaker will cut off the input power automatically once a short circuit happens.
    • At Battery Mode, the UPS will beep 3 sounds rapidly for around 10 seconds, then shut down automatically.
  6. BATTERY REVERSE CONNECTION PROTECTION
    Once the batteries are reverse connected (battery polarity wrong), the internal DC fuse will be burnt to prevent inverter from being. Please contact Technical Service of NTEC sp.z o.o. to replaceit.

MAINTENANCES

This UPS is basically maintenance-free! while regular maintenance can extend the life of the UPS by the following steps:

  • REGULAR INSPECTION
    • Disconnect the UPS from the mains power and battery completely.
    • Use cotton cloth and detergent to clean the body and ventilation holes.
  • EXTRAORDINARY INSPECTION
    • When a malfunction occurs, or the UPS is abnormal, please measure and check the parameters, refer to the authorized dealer if needed.
    • During storms or the rainy season, a detailed inspection should be carried out to prevent failure.
    • Maintenance must not be operated when UPS is working.

OTHERS
This UPS has been designed and manufactured in accordance with strict standards and a quality control system for general use, but if it causes danger to the lives of people or others, please contact the dealer.

  • Apply to traffic system;
  • Apply to medical purpose;
  • Apply to nuclear, power system;
  • Apply to aviation and aerospace;
  • Apply to all kinds of safety devices;
  • Other special usages.

DISPLAY & AUDIBLE ALARM

PROBLEM-SOLVING

ECOLOGICAL INFORMATION

Waste electrical and electronic equipment are a special waste category, collection, storage, transport, treatment and recycling are important because they can avoid environmental pollution and are harmful to heath submitting waste electrical and electronic equipment to special collection centers makes the waste to be recycled properly and protecting the environment.

Producer
NTEC sp. z 0.0.
ul. Chorzowska 44B,
44-100 Gliwice, Poland

qoltec.com
WEEE/BDO: 000137497