Rinnai EHPT250VM A Series Heat Pump Hot Water System
This appliance must be installed in accordance with:
- Manufacturer’s Installation Instructions
- Current AS/NZS 3500
- Plumbing Code of Australia (PCA)
- Local Regulations and Municipal Building Codes including local OH&S requirements
This system must be installed, commissioned, serviced, maintained and removed ONLY by an Authorised Person.
NOT SUITABLE AS A POOL OR SPA HEATER
For continued safety of this appliance it must be installed and maintained in
accordance with the manufacturer’s instructions.
Standard: AS3498:2020 Licence Number: WMK26787 SAI Global
Australian Standard
Standard: AS/NZS 2712:2007
Licence Number: SMK41304
SAI Global
WARNINGS AND IMPORTANT INFORMATION
SAFETY AND REGULATORY INFORMATION
WARNING
- DO NOT operate this system before reading the manufacturers instructions.
- This appliance must be installed, commissioned and serviced by an authorised person in accordance with all applicable local rules and regulations.
- Access covers of water heating system components will expose 240V wiring and MUST only be removed by an authorised person.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- For continued safety of this appliance it must be installed, operated and maintained in accordance with the manufacturer’s instructions.
- Children should be supervised to ensure they DO NOT play with the appliance.
- The Heat Pump is fitted with a power cord & 15 amps plug , It MUST connect to an independent, fused, AC 240V 50 Hz power supply with an isolating switch installed at the switch board, which shall effectively isolate all active supply conductors from the circuit and means for disconnection MUST be incorporated in the fixed wiring in accordance with the wiring rules. If the power supply cord is damaged, it MUST be replaced by an authorised person in order to avoid a hazard. Take care not to touch the power connections or plugs with wet hands.
- Care should be taken not to touch the pipe work as it may be HOT!
- DO NOT place articles on or against this appliance.
- DO NOT store chemicals or flammable materials near this appliance.
- DO NOT operate with collectors or covers removed from this appliance.
- DO NOT activate heat pump unless cylinder is full of water.
- NEVER use a flammable spray such as hair spray, paint, etc near this unit as this may cause a fire.
WARNING
MANDATORY INSPECTION PRIOR TO INSTALLATION
Immediately report any damage or discrepancies to the Supplier of the
appliance. This appliance was inspected and tested at the time of manufacture
and packaging, and released for transportation without known damage. Upon
receipt, inspect the exterior for evidence of rough handling in shipment.
Ensure that the appliance is labelled correctly for the gas and electrical
supply, and/or other services it is intended to be connected to. For safety
and warranty purposes, appliances that may be damaged or incorrect must not be
installed or operated under any circumstances. Installation of damaged or
incorrect appliances may contravene local government regulations. Rinnai
disclaims any liability or responsibility whatsoever in relation to the
installation or operation of damaged or incorrect appliances.
NOTICE TO VICTORIAN CONSUMERS
This appliance must be installed by a person licensed with the Victorian
Building Authority. Only a licensed person will have insurance protecting
their workmanship. So make sure you use a licensed person to install this
appliance and ask for your Compliance Certificate. For further information
contact the Victorian Building Authority on 1300 815 127
TRANSPORT AND STORAGE OF APPLIANCE
RISK OF FIRE
The appliance(s) shall be stored and transported in an area without
ignition sources (for example: open flames, an operating gas appliance or an
operating electric heater)
DO NOT pierce or burn the appliance. Be aware that refrigerants may not
contain an odour. Compliance with AS/NZS 5149 MUST be observed while storing
the appliance.
IMPORTANT
National and state regulations exist for storage, handling and transport of
hazardous goods including flammable gasses. The maximum number of pieces of
equipment or the configuration of the equipment, permitted to be transported
or stored together will be determined by the applicable regulations.
IMPORTANT IMPORTANT
DO NOT TILT MORE THAN 45° FROM VERTICAL
The Rinnai Electric Heat Pump must be transported at an angle no greater that 45º from vertical. As the compressor unit is located at the top of the electric heat pump, should the heat pump be tilted at a greater angle than 45º from vertical, the lubrication oil within the compressor can run down into the mufflers. This will leave the compressor motor without sufficient lubrication and lead to premature failure of the compressor unit. As a general good practice it is better to keep the compressor upright as much as possible to avoid any risks. Returning the Rinnai Electric Heat Pump to a vertical position will allow the oil to properly flow back into the compressor motor. Tilting beyond 45º from vertical will also place undue strain on compressor motor mounts and associated piping.
WARNING
Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer. The appliance shall be stored in a
room without continuously operating ignition sources. For example, open
flames, an operating gas appliance or an operating electric heater. Do not
pierce or burn. Be aware that refrigerants may not contain an odour.
SCALD HAZARDS
DANGER BEWARE OF SCALDING HAZARDS
HOT WATER CAN CAUSE SCALDS. CHILDREN, DISABLED, ELDERLY AND THE INFIRM ARE AT THE HIGHEST RISK OF BEING SCALDED. FEEL WATER TEMPERATURE BEFORE BATHING OR SHOWERING. SCALDS FROM HOT WATER TAPS CAN RESULT IN SEVERE INJURIES TO YOUNG CHILDREN. SCALDS OCCUR WHEN CHILDREN ARE EXPOSED DIRECTLY TO HOT WATER WHEN THEY ARE PLACED INTO A BATH WHICH IS TOO HOT.
ALWAYS……
Test the temperature of the water with your elbow before placing your child in
the bath, also carefully feel water before bathing or showering yourself.
Supervise children whenever they are in the bathroom. Make sure that the hot
water tap is turned off tightly.
CONSIDER…..
Installing child proof tap covers or child resistant taps (both approaches
will prevent a small hand being able to turn on the tap). Installing tempering
valves or thermostatic mixing valves which reduce the hot water temperature
delivered to the taps. Your local plumbing authority may already require that
these be fitted. Contact your installer or local plumbing authority if in
doubt.
NEVER….
Leave a toddler in the care of another child. They may not understand the need
to have the water temperature set at a safe level.
OPERATING PRINCIPLE
The operation of an electric heat pump is similar to a refrigerator, but in
reverse. A heat pump operates by transferring heat from the ambient outside
air into the water. Electricity is just used to operate the system, but not to
directly heat the water. Because of this energy consumption is significantly
reduced as compared to an electric element hot water system. The warmer the
climate in which the heat pump is installed, the more efficient the heat pump
system will be at heating water. The heat pump unit includes highly efficient
copper tube heat exchanger wrapped around the inner cylinder for thermal
conductivity. A temperature sensor in the tank is used to control the heat
pump operation to achieve suitable tank temperature.
During the occasional times when the ambient weather conditions aren’t
suitable for the heat pump to operate, the electric element will provide
heating to ensure a supply of hot water.
SYSTEM SCHEMATIC
SAFETY DEVICES
The water heating system is supplied with various safety devices including
temperature sensors, overheat sensors and switches and a Pressure &
Temperature Relief (PTR) valve. These devices must not be tampered with or
removed. The water heating system must not be operated unless each of these
devices is fitted and is in working order.
WARNING
DO NOT tamper with or remove safety devices.
DO NOT operate the water heater unless all safety devices are fitted and in
working order.
DO NOT block or seal the PTR Valve and drain pipe.
Pressure & Temperature Relief (PTR) Valve
This valve is located near the top of the water heater and is essential for
safe operation. It is normal for the valve to release a small quantity of
water through the drain line during heating.
However, continuous leakage of water from the valve and its drain line may
indicate a problem with the water heater.
Lift lever until w ater flow s from drain line (Low er lever gently!)
WARNING
NEVER block the outlet of the PTR valve or its drain line for any reason. The
easing gear MUST be operated at least every 6 months to remove lime deposits
and verify that it is not blocked. Failure to do this may result in the water
heater failing. If the valve does not discharge water when the easing gear
lever is opened, or does not seal again when the easing gear is closed,
attendance by an authorised person MUST be arranged without delay. The PTR
valve is not serviceable.
EXCESSIVE DISCHARGE FROM SAFETY DEVICES
Pressure & Temperature Relief (PTR) Valve
It is normal and desirable that this valve allows a small quantity of water to
be discharged during the heating cycle. If it discharges more than a bucket of
water during a 24 hour period or discharges continuously there may be another
problem. If the valve dribbles continuously, try easing the valve gear for a
few seconds as described above. This may dislodge any foreign matter and
alleviate the problem. If the valve discharges at high flows, especially at
night, it may be as a result of the water pressure exceeding the design
pressure of the water heater. Ask your installer to fit a Pressure Limiting
Valve (PLV).
WARNING
NEVER replace the PTR valve with one which has a higher pressure rating
than is specified for your water heater.
Expansion Control Valve (ECV) – if required
It is normal that this valve allows a small quantity of water to be discharged
during the heating cycle. If it discharges more than a bucket of water during
a 24 hour period or discharges continuously there may be another problem. If
the valve leaks continuously, try easing the valve gear for a few seconds.
This may dislodge any foreign matter and alleviate the problem. If it does
not, please contact Rinnai. Operate the easing gear regularly to remove any
lime deposits and to verify that it is not blocked.
HYDROGEN GAS
If the hot water unit is not used for two weeks or more, a quantity of
hydrogen gas, which is highly flammable, may accumulate in the water heater.
To dissipate this safely, it is recommended that a non-electrically operated
hot tap be turned on for two minutes at a sink, basin, or bath, but not a
dishwasher or other appliance. During this procedure there MUST be no smoking,
open flame or any electrical appliance operating nearby. If hydrogen is
discharged through the tap, it will probably make a sound like air escaping.
TURNING ON THE WATER HEATING SYSTEM
Switch on the electric supply to the heat pump unit. Water heating will now
occur as required. It may take a number of hours before hot water is
available.
TURNING OFF THE WATER HEATING SYSTEM
If you plan to be away for only a few nights, we suggest you leave the water
heating system switched on. If it is necessary to switch off the water heater,
do so as outlined below:
WARNING
DO NOT turn power off to the heat pump unit if snow or frost conditions are
expected as components in the system may be damaged by freezing. If power
needs to be turned off or power failure occurs and freezing conditions are
expected, the water needs to be drained from the heat pump unit. Follow the
procedure described below in the section ‘Draining and Filling’.
DRAINING AND FILLING
Draining or filling of the complete system normally only occurs during installation or servicing and must be carried out by an authorised person. Draining water from the heat pump unit is necessary if the power will be shut off to the unit and snow or frost conditions are expected. Arrange for an authorised person to carry out this task.
To drain the heat pump:
- Turn off power to the heat pump
- Close the cold water mains supply stop cock
- Open a hot tap to relieve pressure
- Disconnect the hot outlet near the top of the storage cylinder
- Disconnect the cold inlet near the bottom of the storage cylinder.
- The system will now drain completely.
MAINTENANCE AND REGULAR CARE
Operate the easing gear of the PTR and the ECV if fitted as described in the
section ‘Safety Devices’ on page 7. The overflow tray (supplied by installer)
and drain underneath the storage cylinder (if fitted) should be periodically
checked to ensure there are no blockages.
WARNING
DO NOT drill, screw or fix any ancillary items to the of the tank. This
product is fitted with a high efficiency heat exchanger attached to the inner
cylinder, anything penetrating the outer skin of the tank may damage the heat
exchanger.
SAVE A SERVICE CALL
Rinnai’s servicing network personnel are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs service, ring one of the service contact numbers on the back of this booklet. The pressure and temperature relief valve and expansion control valve (if fitted) must be replaced by an authorised person at intervals not exceeding 5 years or more frequently in areas where the water is classified as scaling water. If the power supply cord to the heat pump unit is damaged, they must be replaced by an authorised person in order to avoid a hazard. Use the following guide to avoid the need for an unnecessary service call.
INSUFFICIENT OR NO HOT WATER
Heat Pump Unit Not Powered| Check to ensure the electric isolating
switch at the switchboard (usually marked “Hot water” or “Water heater”) is
turned on. (note that the compressor may not start up for 2 minutes after
power is turned on).
Excessive hot water consumption| Often, end users are surprised at the
amount of hot water used, especially when showering. If the amount of hot
water used during the day exceeds the storage capacity of the cylinder, it is
likely there will be insufficient hot water.
Pressure & Temperature Relief (PTR) Valve continually discharging water|
It is normal and desirable that this valve allows a small quantity of water to
be discharged during the heating cycle. If it discharges more than a bucket of
water during a 24 hour period or discharges continuously there may be another
problem.
If the valve dribbles continuously, try easing the valve gear for a few
seconds as described in the section ‘Excessive Discharge from Safety Devices’
on page 8. This may dislodge any foreign matter and alleviate the problem.
If the valve discharges at high flows, especially at night, it may be as a
result of the water pressure exceeding the design pressure of the water
heater. Ask your installer to fit a Pressure Limiting Valve (PLV).
Expansion Control Valve (ECV) continually discharging water| It is
normal and desirable that this valve allows a small quantity of water to be
discharged during the heating cycle. If it discharges more than a bucket of
water during a 24 hour period or discharges continuously there may be another
problem. If the valve leaks continuously, try easing the valve gear for a few
seconds as described in the section ‘Excessive Discharge from Safety Devices’
on page 8. This may dislodge any foreign matter and alleviate the problem. If
this does not alleviate the problem contact Rinnai.
Ambient conditions too hot| To protect the components of the heat pump
unit it may not operate when the ambient temperature is higher than 43°C. The
heating element will operate if water heating is required, but may take longer
to heat the water.
Ambient conditions too cold| To protect the components of the heat pump
unit it may not operate when the ambient temperature is less than -7°C. The
heating element will operate if water heating is required.
NO WATER FROM THE TAP
Restriction in the hot tap or failure of the cold water supply to the water
heater| Check for water flow at the other taps and that the cold water
isolation valve is fully open.
HIGH ELECTRICITY BILLS
Excessive hot water consumption| See entry under the heading
‘Insufficient or no hot water’
High Electricity Tariffs| The electricity tariff will determine the
running costs of the system. It is important the end user is aware of the
applicable tariffs. Contact your electricity supplier to confirm what these
tariffs are.
Higher Element Usage| In extremely cold conditions the element may be
operating more than normal.
WATER FLOW FLUCTUATIONS
One or more hot taps opened at the same time| More than one or two hot
taps in use at the same time may cause a decrease in the hot water flow from
the taps.
Is there more than one or two hot taps open, or are appliances such as a
dishwasher or washing machine, in use at the same time?
Ensure only one or two hot taps are on at one time.
WATER HAMMER
Hot and cold water plumbing in the premises| Have a plumber check
clipping of hot and cold water pipe work and install a pressure limiting valve
and water hammer arrestor as required.
HEAT PUMP ICES UP
Defrosting function| The heat pump has a built in Reversing Valve which
energises for a defrosting function which operates to remove ice on the
outdoor evaporator coil.
HEAT PUMP ERROR INDICATOR
When an Error is detected with the Heat Pump, the “Fault” icon on the display
screen will illuminate, and the setting temperature window displays the
current fault code:
FAULT CODES
Fault Code | Description | Fault Code | Description |
---|---|---|---|
E1 | Water temperature sensor | E0 | Parameter error fault |
E2 | High voltage fault | EA | **High temperature protection of compressor |
exhaust air
E3| Fin temperature sensor| ED| Antifreeze protection
E4| Ambient temperature sensor| ET| The ambient temperature is not in
the operating range of the heat pump
E5| Return air temperature sensor| EE| High compressor current
E6| Exhaust temperature sensor| EB| Low compressor current
E7| Low pressure protection| EF| Communication fail
E8| Hot water temperature sensor**| |
SPECIFICATIONS
SYSTEM SPECIFICATIONS
Model | EHPT250VM |
---|---|
Net Weight / Filled Weight (kg) | 125 / 378 |
Sound Level | 48 dB(A) |
Ambient Temperature Limits
(for heat pump operation – element will operate beyond these limits)| -7°C to
43°C
Ingress Protection| IPX4
Storage Cylinder – Hot Outlet and Cold inlet Connections| ISO 7.1 ¾” RP
Storage Cylinder – PTR Valve Connection| ISO 7.1 ¾” RP
Pressure & Temperature Relief (PTR) Valve (Supplied) Setting / Rating| 850 kPa
/ 30kW
ECV Fitted (700 kPa)| Fit PLV if mains pressure exceeds| 550 kPa
Recommended PLV pressure rating| 450 kPa
ECV Not Fitted| Fit PLV if mains pressure exceeds| 680 kPa
Recommended PLV pressure rating| 500 kPa
Rated Input Electric Element (Factory Wired)| 1.5 kW
Maximum Input Refrigeration Module (Factory Wired)| 0.9 KW
Total Maximum Input| 2.4 KW
Maximum Energy Output (Use to size PTR)| 5.5 kW
Power Supply| 220-240 V AC, 50 Hz.
20 Amp Power point required in close proximity to the Heat Pump
Maximum Current| 11 Amps (15 Amp plug fitted)
20 Amp Safety Switch must be installed at the switchboard
Refrigerant Type / Mass| R134a / 1 kg
Refrigerant Circuit Maximum Pressure| 2700 kPa
Coefficient Of
Performance (COP)| 32.6°C Ambient
21.1°C cold water inlet| 7.5
Heat Output| 32.6°C Ambient
21.1°C cold water inlet| 3.1 kW
DIMENSIONS
Model | EHPT250VM |
---|---|
Cylinder height | 2140 |
Hot Outlet / PTR (A) | 1445 |
Cold water inlet (B) | 145 |
Cylinder diameter | 570 |
All Dimensions in mm
CLEARANCES
Allow 600mm on the plumbing connection side and 200 mm clearance on the fan
suction side to allow for sufficient air flow through the fan. Also allow
300mm clearance at the front of the unit for control access and service.
Model | EHPT250VM |
---|---|
Min Clearance Height H1 (mm) | 550 |
INSTALLATION
REGULATIONS AND OCCUPATION HEALTH AND SAFETY (OH &S)
WARNING
Installation and commissioning MUST be performed by authorised persons. The
heat pump MUST be installed in accordance with these instructions and all
regulatory requirements which exist in your area including those in relation
to manual lifting.
Applicable publications and regulations may include:
- AS/NZS 3500 National Plumbing and Drainage
- AS/NZS 3000 Wiring Rules
- Building Codes of Australia (BCA)
- Local Occupational Health and Safety (OH&S) regulations
This appliance is not suitable for use as a domestic spa pool or swimming pool heater. Electric Heat pumps are heavy and bulky items. Australian States and Territories have Principal Occupational Health and Safety (OH&S) Acts with requirements relating to handling of large, bulky or awkward items. Persons installing heat pump systems MUST be aware of their responsibilities and be adequately trained and qualified, in accordance with local OH&S requirements.
LOCATION
The electric heat pump can be installed externally or internally.The electric heat pump should be placed as close as practicable to the most frequently used hot water outlet point or points to minimize the delay time for hot water delivery. This will usually be the kitchen tap. For installations where the distance between the heat pump and the outlets is considerable, a flow and return system can be used which minimize the waiting time for hot water delivery. It is recommended that all components are installed at ground or floor level with consideration for easy service, repair or replacement access.. The heat pump MUST be installed in a vertically upright position. All components MUST be accessible without the use of a ladder or scaffold.
The unit MUST NOT be installed in roof spaces. The air inlet and outlet of the heat pump module MUST be away from areas with strong wind and MUST be provided with sufficient clearances as per those shown in the section ‘Clearances’ on page 14. The heat pump MUST be connected to an independent AC 240 V, 50 Hz power supply. Ensure the pressure and temperature pressure relief (PTR) valve and any access covers have sufficient clearances and are accessible for service and removal. The information on the rating plates MUST also be readable.
The heat pump MUST be installed free-standing on a level and stable base no more than 2° off perpendicular to level ground. The cylinder should be mounted on a concrete base at least 50mm thick or on, evenly spread hardwood slats with a thickness of at least 25mm. Where property damage can occur as a result of water leakage, the storage cylinder MUST be installed with a safe tray (overflow tray) at least 50mm larger than the diameter of the water heater and drain in accordance with AS 3500.4. Ensure the storage cylinder DOES NOT stand on wet surfaces.
Internal Installation
For internal installations the area MUST meet the following requirements:
- Minimum room volume of 10m3 per unit.
- Good Ventilation (i.e minimum 200 L/s per unit)
- Away from any ignition sources or corrosive environments.
If the heat pump is installed internally careful consideration should be taken in regards to positioning and limiting the effect of unit noise and reverberation during operation.
WARNING
Ensure the location complies with the requirements of AS/NZS 60335.2.40 & AS /
NZS 5149.
Condensation
As this heat pump is highly efficient the surrounding air temperature could be
cooled by up to 4°C and condensate formed, the condensate will need to plumbed
to a suitable drain.
Drainage
Where property damage can occur as a result of water leakage, the water heater
MUST be installed with a safe tray (overflow tray) and drain. Construction,
installation and draining of the safe tray MUST comply with local regulatory
requirements and. AS/NZS 3500.4 also requires the use of a safe tray for
particular situations.
WATER SUPPLY
This appliance is intended to be permanently connected to the water mains and
not to be connected by a hose set. The maximum water pressure is listed on
page 12. An approved pressure limiting valve may be required if the maximum
rated water supply pressure is exceeded. Water chemistry and impurity limits
are detailed in the separate warranty document. Most metropolitan water
supplies fall within these requirements. If you are unsure about water quality
and suitability, contact your water authority.
A water filter MUST be fitted on the inlet to the tank to prevent sludge or foreign matter entering the system. In a scaling water supply, calcium carbonate and possibly other compounds are deposited out of the water onto any hot metallic surface and form a scale. Scaling water may cause scale deposits to form onto the metallic surfaces of the PTR valve and may prevent it from operating properly. To prevent this, an Expansion Control Valve (ECV) MUST be fitted on the cold water line after the non-return valve in areas of scaling water. ECVs MUST be fitted in South Australia and Western Australia to comply with local regulations.
STORAGE TEMPERATURE
To meet regulatory requirements the thermostat control on the heat pump water
heater is factory pre-set to 60°C. It is recommended that this temperature is
not altered.
HOT WATER DELIVERY TEMPERATURE
This appliance may deliver water at high temperature. Refer to the Plumbing
Code of Australia (PCA), local requirements and installation instructions to
determine if additional delivery temperature control is required. The PCA,
local regulations and the requirements of AS/NZS 3500.4 MUST be considered
regarding the temperature limitations of hot water supplied to areas used
primarily for personal hygiene. The temperature of water to certain areas is
limited to different temperatures according to purpose, for e.g. early
childhood centres, primary and secondary schools and nursing homes or similar
facilities for young, aged, sick or people with disabilities and for all other
buildings. To comply with these requirements, a temperature limiting device,
such as a thermostatic mixing or tempering valve, will be required on hot
water systems.
VALVES AND FITTINGS
IMPORTANT
A 30 kW capacity, combined Pressure and Temperature Relief (PTR) valve is
supplied with the Heat Pump hot water system. This valve is fitted at the top
of the storage cylinder. The PTR valve is a safety device and it is mandatory
that it is fitted by the installer in all installations.
The following valves & fittings are to be supplied by the installer:
- A cold water Expansion Control Valve (ECV). An ECV MUST be fitted in Western Australia and South Australia to the cold water supply to the storage cylinder to comply with local regulations. An ECV is recommended in all other geographical areas where the water supply has a tendency to cause scaling. This will reduce hot water discharge from the pressure and temperature relief (PTR) valve which minimises wear on this valve.
- A stop cock, non return valve and line strainer. Combination valves incorporating two or more of these functions (such as ‘Trio’ valves) are suitable. These are fitted to the cold water supply to the storage cylinder by the installer.
- Cold water supply and hot water discharge pipework to and from the storage cylinder. This pipework MUST be insulated as specified in AS/NZS3500.4
- An approved pressure limiting valve (supplied with some systems) is required if the maximum rated water supply pressure on page 12 is exceeded.
- Tempering valve(s) or thermostatic mixing valve
TRANSPORT AND HANDLING
IMPORTANT
When moving the unit, it MUST be close to vertical at all times. When using a
trolley to move the unit, ensure it is not tilted more than 45° from the
vertical. Non compliance will void warranty and severely affect product
performance and operation
The Rinnai Electric Heat Pump MUST be transported at an angle no greater that 45º from vertical. As the compressor unit is located at the top of the electric heat pump, should the heat pump be tilted at a greater angle than 45º from vertical, the lubrication oil within the compressor can run down into the mufflers. This will leave the compressor motor without sufficient lubrication and lead to premature failure of the compressor unit. As a general good practice it is better to keep the compressor upright as much as possible to avoid any risks. Returning the Rinnai Electric Heat Pump to a vertical position will allow the oil to properly flow back into the compressor motor. Tilting the heat pump beyond 45º from vertical will also place undue strain on compressor motor mounts and associated piping.
POSITIONING THE HEAT PUMP
Arrive at site and conduct a safety audit (Safety audits can also be known as
Work Method Statements (WMS) or Job Site Analysis (JSA). Park your vehicle as
close as allowable to your installation. Unload all materials in a safe
manner. Position all materials in a convenient position near the work area.
Refer to “Location” on page 15 positioning consideration and requirements for
all installations. Where the requirements for internal installation can’t be
met, the heat pump MUST be installed outdoors. The location MUST also consider
noise impact on living areas. Avoid positioning near bedrooms or neighbours’
bedrooms. Although the running noise level is very low it can be expected that
the heat pump will run during the night. Adequate access MUST be available to
the relief valve and anode. Safely position the new unit on a level surface in
accordance with all plumbing and building regulations. A properly drained
overflow tray MUST be used where property damage could occur from water
spillage. (See AS/NZS3500.4.2 for further details.)
NOTE
DO NOT drain on to grass or garden beds. DO NOT commence a job where the
risks cannot be controlled.
Ensure the requirements specified in the section ‘Clearances’ on page 14. are complied with. The area MUST also be clear of debris such as leaves and tree branches.
CONNECT THE PTR VALVE
Connect the PTR valve to the uppermost fitting of the storage cylinder. See
the diagram on page the section ‘Dimensions’ on page 13. The PTR pressure
rating MUST be suited for the cylinder and adequate for the thermal loading
applied to the storage cylinder, as specified in the table on 12. The supplied
PTR valve input rating is 30.0 kW. The PTR valve rating MUST EXCEED the total
input from the heat pump. For example, the maximum output is 5.5 kW (see the
table on page 12). This is less than 30.0 kW, hence the supplied PTR valve is
of sufficient capacity.
Use Teflon thread tape on the valve, never use hemp or other sealing materials. Ensure the tape does not protrude past the end of the thread, which could result in it hanging over the end of the thread and blocking the water passage through the valve. Connect the supplied PTR valve into the top socket marked “Relief Valve”. Leave the valve outlet pointing down. Tighten the valve using the spanner flats – never use the valve body. Discharge according to plumbing regulations. PTR Valves for the unit are rated at 850kpa. The drain line from this valve MUST run in a continuously downward direction with the discharge end left permanently open to atmosphere.
PLUMBING CONNECTIONS
Refer to the diagram on page 20 for detailed information on position of
plumbing. An approved isolating valve, non return valve, line strainer, and
union MUST be fitted between the supply main and the RP ¾ socket in the water
heater. All fittings MUST be approved by the relevant installation Authority.
An ECV MUST be fitted in Western Australia and South Australia to the cold
water supply to the storage cylinder to comply with local regulations. An ECV
is recommended in all other geographical areas where the water supply has a
tendency to cause scaling.
This will reduce hot water discharge from the pressure and temperature relief (PTR) valve which minimises wear on this valve. This water heater is designed for direct connection to water supply pressures of no greater than those specified on page 12. Where the mains pressure can exceed or fluctuate beyond this, a pressure limiting (PLV) device (complying with AS1357) MUST be fitted.
CONNECT COLD / HOT WATER SUPPLY
Connect cold water supply, Pressure Limiting Valve (PLV) and or Expansion
Control Valve (ECV). Connect cold water supply to the storage tank (refer to
Diagram BELOW). A stop cock, non return valve and line strainer MUST be
fitted.
Connect the pipe work supplying hot water to the premises to the hot water outlet on the tank. A temperature limiting device may be required as detailed in the section the section ‘Hot Water Delivery Temperature’ on page 16 It is recommended that all hot water lines are insulated with high temperature, UV resistant 13mm closed cell insulation.
CONNECT CONDENSATE DRAIN LINE
A condensate drain line is required to be fitted to carry discharge clear of
the water heater. The condensate drain line should not be connected to the PTR
drain line but can exit to the same point. The diagram below shows the
location of the condensate drain on the heat pump. Use the supplied PVC pipe
(inner diameter 9mm, UV resistant) to connect to the condensate outlet.
Independent 15mm copper pipes MUST be fitted to the drain outlets of the PTR
and ECV. Each pipe MUST be open to atmosphere and run with a continual
downward grade in a frost free environment to a visible discharge point. Drain
lines MUST not exceed 9 meters in length. Valves or other restrictions MUST
NOT be placed in the relief valve drain outlet line.
TYPICAL PLUMBING LAYOUT
ELECTRICAL CONNECTIONS **
**
WARNING
The power supply to the heat pump module MUST NOT be activated until the
system is filled with water. The premises wiring to the heater MUST be capable
of withstanding the appliance load. Refer to specification table for load
details. All electrical connections and wiring MUST be installed, maintained
and removed by authorised persons in accordance with AS/NZS 3000, and all
other relevant local regulations and municipal building codes including OH&S
requirements.
IMPORTANT
The Heat Pump is fitted with a power cord & 15 amp plug, It MUST connect to
an independent, fused, AC 240V 50 Hz power supply with an isolating switch
installed at the switch board, which shall effectively isolate all active
supply conductors from the circuit and means for disconnection MUST be
incorporated in the fixed wiring in accordance with the wiring rules.
A Residual Current Circuit Breaker is recommended for the power supply to this
appliance (this may be a mandatory requirements in some states or
jurisdictions).
IMPORTANT
This appliance MUST NOT be connected via a switchable or a solar
(photovoltaic – PV) power supply without manufacturer consultation and
authorisation. The switching of the supplies will place the water heater into
a re-start cycle which reduces the available heating time and may result in a
lack of hot water. It is recommended this appliance is connected to either a
24 hour continuous tariff or an extended off-peak power supply (minimum 16
hours per day), noting that the minimum required running time is governed by
hot water demand and the climate zone. If this appliance is replacing an
electric water heater with a capacity of 250 litres (or greater), then a
connection to a 24 hour continuous tariff supply is recommended.
Disconnect all power prior to installation and commissioning. This appliance
is designed for single phase 240 Volts, AC mains electrical operation.
Cord Management
Make sure that the power cord attaches to the power outlet at a point higher
than it exits the appliance (1). Alternatively loop the cord (2) so that any
water is not directed to the the power socket.
WIRING SCHEMATIC
ELECTRICAL TESTS
DO NOT turn on the power supply to the appliance until it has been filled with
water and a satisfactory insulation (Megger) test has been performed.
Conducting Insulation (Megger) Tests
When conducting an insulation test using a Megger on this appliance,
observe the then the following:
WARNING
This appliance contains electronic components, when performing insulation
tests (500 Volts) this MUST ONLY be conducted the across active terminal to
earth and then across the neutral terminal to earth. Tests between the active
to neutral terminals MUST NOT be performed as this WILL damage the electronic
components.
Insulation test results of between 100 kΩ and 660 kΩ are normal for this appliance. In accordance with AS/NZS 3000 an insulation test with a result less than 1 MΩ is permitted where the appliance is approved to a Standard applicable to that class of appliance. This appliance is categorised and certified as a ‘stationary Class 1 motor operated appliance’ and therefore satisfies the requirements of AS/NZS 60335.2.40 for leakage current and electric strength. As such, this appliance complies with the insulation resistance requirements of AS/NZS 3000.
FILLING THE SYSTEM
Open hot water tap at sink. Open the stop cock in the cold water main supply
line. Allow the system to fill and the air to bleed through the tap. Turn off
the hot tap at the sink when water flows freely without any air bubbles or air
bursts. Bleed any remaining air from the PTR valve. If leaks are detected turn
off power to the heat pump, repair any leaks and repeat the filling process to
remove any air. If no leaks are detected water heating can commence. The heat
pump will start up after the 2 minute protection delay.
COMMISSIONING AND FINISHING THE INSTALLATION
IMPORTANT
Please confirm the following before commissioning:
- Piping and electrical wiring are all correct
- Earthing wire is installed properly
- Pipe insulation is completed
- Tank is filled
- Supply Voltage complies with rated voltage
- Air intake and discharge are not obstructed
Turn on power to the heat pump unit and wait a few seconds for the system to start. Change operation mode or water temperature setting if required (it is recommended to retain default setting however). After testing is completed, explain to the customer the functions and operation of heat pump water heater components. Explain the need to drain the heat pump if freezing conditions are likely or power is likely to be shut off for an extended time. Also explain to the customer the importance of carrying out maintenance in accordance with this manual. Leave the manual with them upon completion of the installation.
WARNING
DO NOT drill, screw or fix any ancillary items to the of the tank. This
product is fitted with a high efficiency heat exchanger attached to the inner
cylinder, anything penetrating the outer skin of the tank may damage the heat
exchanger.
OPERATION
CONTROLLER LAYOUT
Controller Icons
Icon | Description | Icon | Description |
---|---|---|---|
Eco Mode | Compressor State | ||
Hybrid Heating Mode | Electric Heating State | ||
Electric Heating Mode | Child Lock | ||
Temperature Setting | Tank Temperature | ||
Fault Warning | Wi-Fi State | ||
Timer | Clock Display |
Control Keys
Key Symbols
| ON/OFF| M
MODE LOCK| TIMER| SET| |
---|---|---|---|---|---|---
Function| Power On/Off| Mode / Lock| Timer| Settings| Temperature Up|
Temperature Down
When the unit is powered on, all the symbols will be displayed for approximately 2 seconds.
OPERATING FUNCTIONS
**On / OFF
** ON/OFF
- In standby mode, press the ‘on/off’ key once to perform the startup function and display the mode before the last shutdown.
- In the start-up mode, press the ‘on/off’ key once to shut down the appliance.
- Press ‘SET’ and ‘On/Off’ together and hold for 3 seconds to enter the Wi-Fi setting functions.
Mode / Lock
M
MODE LOCK
Press the ‘MODE’ key to cycle between Modes in this sequence: ECO →HYBRID →
E-HEATER
- Eco mode: The unit is set to economy mode, the hot water temperature is adjustable in the range of 30-60°C , the compressor is running at 30-60°C.
- Hybrid heating mode: The unit is set to hybrid heating mode. The hot water temperature is adjustable in the range of 30-70°C. The compressor and electric heating are running at 30-60°C, and the electric heating is running at 60-70°C.
- Electric heating mode: The hot water temperature is adjustable in the range of is 30-70°C, the electric heating will be operated within this range.
Every time the unit is powered on it will automatically enter the last operational mode it was in before shutdown.
Locking function
- Press and hold the ‘MODE LOCK’ key for 3 seconds to activate the child lock. Press and hold again for 3 seconds to release the lock.
Timer
Timer setting
TIMER
- Press the “TIMER” key for 3 seconds and then release to enter the time setting. The hours and minutes in the time display area will flash at the same time. Press the “TIMER” key again, and the hours in the time display area flash. Press the “up” key or “down” key to adjust the hours; Press “SET”, and the minutes in the time display area will flash. Press the “up” key or the “down” key to adjust the minutes; After the time setting, press the “SET” key to save and exit.
Timed start-up
- When there is no timing setting in the normal interface, press the “TIMER” key once to enter the timed startup setting interface and timer symbol in the time area will flash, and “ON” is displayed in the temperature area of the water tank. The default time display is 00:00, and the hour area flashes. Press the “SET” key to switch to the minute setting, and the minute area flashes. Then press the “SET” key to switch to the timed shutdown setting.
Timed shutdown
- The timer symbol in the time area flashes, and “OFF” is displayed in the temperature area of the water tank. The default time display is 00:00, and the hour area flashes. Press the “SET” key to switch to the minute setting, and the minute area flashes. Then press the “SET” key to save the timer setting.
Cancel timing
- When the timer is active, press the “TIMER” key once to cancel the timing.
**Settings
** The key is used in timed startup and timed shutdown setting, see the previous timing setting operation for details;
- Press and hold the “SET” key for 3 seconds to enter the parameter inquiry page.This function is mainly intended for use by qualified installation and maintenance personnel.
See the following table for parameter details:
Code Description | Number | Remarks |
---|---|---|
Tank temperature 1 (Thw 1) | 01 | Unit: °C |
Tank temperature 2 (Thw 1) | 02 | Unit: °C |
Ambient temperature (Ten) | 03 | Unit: °C |
Fin temperature (Tfr) | 04 | Unit: °C |
Compressor exhaust temperature (Tcomp) | 05 | Unit: °C |
Return temperature | 06 | Unit: °C |
Current of compressor | 07 | Unit: Amps |
Current opening state of electronic expansion valve | 08 | States: Open/Closed |
Set mode | 09 | 00-Eco Heat, 01-Hybrid Heat, 02-Electric Heat |
Heating set temperature (Ts) | 10 | Unit: °C |
Display water temperature | 11 | Unit: °C |
Controller version number | 12 | Example: A05 |
Controller version number | 13 | Example: A01 |
Jumper cap setting model number | 14 | Examples: 01 02 03 |
Last fault code | 15 | Example: E1 |
Second last fault code | 16 | Example: E1 |
Third last fault code | 17 | Example: E1 |
Fourth last fault code | 18 | Example: E1 |
Temperature Up/Down
- “Temperature▲”: The set temperature is increased by 1°C
- “Temperature▼”: the set temperature is decreased by 1°C
- During operation, enter the sequence “[ ▲ ] – [ ▼ ] – [ ▲ ] – [ ▼ ] – [ ▲ ] – [ ▼ ]“ within 5 seconds to initiate forced defrosting.
WI-FI CONNECTION
Please follow below steps to set up and operate Wi-Fi functions.
-
Prepare a Wi-Fi wireless router that can access the Internet, The Wi-Fi frequency band is required to be 2.4 Ghz and it should be placed within 10 meters of the water heater to ensure that a strong Wi-Fi signal is available.
-
Turn on Wi-Fi and Bluetooth on your device. After the connection is successful, you can turn off Bluetooth and operation will not be affected.
-
Scan the QR code below or search in the app market to download and install the ‘Smart Life’ App.
- iOS users – please download from App Store
- Android users – please download from Google Play
-
After completing the installation, open the App, register an account and log in according to the App prompt.
-
Power on the water heater, press ‘Setting’ and ‘On/Off’ together and hold for 5 seconds to enter the Wi-Fi setting functions. The Wi-Fi icon on the display will be flashing.
NOTE
Wi-Fi connecting is available for 3 minutes. You will need to repeat step 5 if the icon stops flashing during the connection -
Connect to the SmartLife App as follows:
-
Search for Device
-
Add Found Device
-
Connect to Wi-Fi
Connect to SmartLife App (cont). -
Wait for Connection
-
Complete
-
Device Connected
-
Control the Heat Pump with the App
The main controls for the App are laid out as follows on the App.
Rinnai Australia Pty Ltd
ABN 74 005 138 769 | AU45204
100 Atlantic Drive, Keysborough, Victoria 3173
P.O. Box 460, Braeside, Victoria 3195
- Tel: (03) 9271 6625
National Help Line
- Tel: 1300 555 545*
Monday to Friday, 8.00 am to 5.00 pm EST.
After Hours Hot Water Service Line
- Tel: 1800 000 340*
*Cost of a local call may be higher from a mobile phone.(National calls from public phones in Australia are free.)
For further information visit www.rinnai.com.au or
email enquiry@rinnai.com.au Rinnai has a
Service and Spare Parts network with personnel who are fully trained and
equipped to give the best service on your Rinnai appliance. If your appliance
requires service, please call our National Help Line. Rinnai recommends that
this appliance be serviced every 3 years.
With our policy of continuous improvement, we reserve the right to change, or
discontinue at any time, specifications or designs without notice.