MASiMO W1 Health and Wellness Tracking Watch User Guide
- September 11, 2024
- MASiMO
Table of Contents
- About This Manual
- Product Description and Features
- * Arterial Oxygen Saturation
- Risks and Benefits
- Description
- Basic Setup and Use
- Advanced Use
- Appendix
- Cleaning, Disinfecting and Service
- Limited Warranty
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MASiMO W1 Health and Wellness Tracking Watch
About This Manual
This manual explains how to set up and use the Masimo W1®. Important safety
information relating to general use of Masimo W1 appears in this manual. Read
and follow any warnings, cautions, and notes presented throughout this manual.
The following are explanations of warnings, cautions, and notes.
A warning is given when actions may result in a serious outcome (for example,
injury, serious adverse effect, death) to the patient or user.
WARNING: This is an example of a warning statement.
A caution is given when any special care is to be exercised by the patient or
user to avoid injury to the patient, damage to this device, or damage to other
property.
CAUTION: This is an example of a caution statement.
A note is given when additional general information is applicable.
Note: This is an example of a note.
Product Description and Features
Product Description
Masimo W1® is a wearable device that continuously tracks health data to better understand your general state of health and promote healthier lifestyle decisions. The Masimo W1 is compatible with the Masimo Health app where users can access, track and trend their health data.
Features
Key features of Masimo W1 include:
- Masimo SET+™ technology.
- Bluetooth® LE for the wireless communication.
The Masimo W1® provides these measurement features:
Oxygen Level (SpO 2 **) *| Oxygen levels in your blood, which can
change with heart and lung function, activity, and altitude.
---|---
Pulse Rate (PR)| How often the heart pushes blood through your body,
which can change with general health, physical activity, and with your mental
or emotional state (e.g., stress, anxiety).
Pulse Rate Variability (PRV)| The changes in your pulse rate that can
show how consistently your blood is being pushed through your body even under
exercise or stress.
Pleth Variability Index (PVi)| A calculation based on the changes in
your perfusion index, which may be affected by your fluid volume during your
respiration cycle and can increase with lower fluid levels.
Perfusion Index (Pi)| A calculation of the relative strength of your
pulse, which changes based on your circulation. The changes in your pulse rate
that can show how consistently your blood is being pushed through your body
even under exercise or stress.
Heart Rate (HR)| The number of times the heart beats in a minute, based
on electrical signals.
Hydration Index (Hi)**| An index calculated to reflect your relative level
of hydration; studies have shown that optimal hydration can improve sleep
quality, cognition, mood, and more.
- Arterial Oxygen Saturation
* Arterial Oxygen Saturation
WARNING: Always consult your physician regarding clinical decisions. Do not rely on the readings for medical decisions. Before use, read the following carefully.
Safety Warnings
WARNING: Do not use if it appears damaged or if you think it is damaged.
Damage to the device can result in exposed sharp edges that may cause harm.
WARNING: Do not adjust, repair, open, disassemble, or modify the Masimo
W1. Damage to the device may result in degraded performance and/or injury.
WARNING: Do not use in areas filled with flammable gases: such as
anesthetics, oxygen, oxygen-enriched environments, or nitrous oxide to prevent
risk of fire.
WARNING: Keep Masimo W1 away from small children. Small items may become
a choking hazard.
Note: Use and store as directed in the Specifications section in this
manual.
Performance Warnings
WARNING: Do not self-diagnose or self-medicate based on the measurements.
Always consult your doctor regarding clinical decisions.
WARNING: See Risk and Benefit Section for information on limitations and
ways to get the most accurate readings.
WARNING: Do not use Masimo W1 as an apnea monitor. Oxygen changes may be
delayed from when your breathing actually stops.
WARNING: The Masimo W1 may not fully charge if the room is too hot.
WARNING: Check the fit of the watchband periodically. Avoid wearing the
Masimo W1 too loose or too tightly to avoid inaccurate readings or pressure
injury.
WARNING: Keep electronics with communication capabilities greater than 30
cm (12 inches) to any part of the Masimo W1. Otherwise, degradation
performance could result.
CAUTION: When using with a smart device, keep both devices within the
recommended range of each other. See Specifications for details. Moving
outside of this range may cause a loss in connection.
CAUTION: Do not place the Masimo W1 near electrical equipment that may
affect the device, preventing it from working properly.
CAUTION: Failure to charge Masimo W1 promptly after a Low Battery
notification message may result in the device shutting down.
CAUTION: To establish and maintain the minimum Quality of Service of the
Masimo W1, the keep the Masimo W1 within ~7 m (~23 ft.) line of sight to the
smart device App.
CAUTION: Move the devices away from sources that may interfere with
Bluetooth connection. The presence of other devices that may create radio
frequency interference (RFI). This may result in loss of Quality of Service.
Example devices that cause RFI are other smart devices, devices with remote
controls, and baby monitors.
Note: All batteries lose capacity with age, thus the amount of run time
at Low Battery will vary depending upon the age of the battery.
Note: A functional tester cannot be used to assess the accuracy of the
Masimo W1.
HR Performance
WARNING: Make sure the Masimo W1 makes good contact with your wrist and
your finger. Poor contact can result in no or incorrect readings.
WARNING: Avoid wearing watch over compromised skin, excessive hair, or
scar tissue, as this may result in incorrect readings.
WARNING: Pacemakers that create fusion beats (pace pulse on top of the
QRS complex) may not be detected by Masimo W1.
WARNING: HR reading can be affected by the following:
- Poor electrode contact.
- Conditions that may increase skin impedance (e.g., dry skin).
- Weak heart signals.
- Excessive movement.
- Electrode or electrodes placement over skin injuries or hair.
- Abnormal heart rhythms due to physiological conditions or induced through external factors (e.g., cardiac arrhythmias, ventricular tachycardia/fibrillation, seizures etc.).
- EMI radiation interference.
- Pacemakers
Cleaning and Service Warnings
WARNING: The following can cause damage that may impact the performance of your Masimo W1:
- Do not attempt to sanitize or sterilize using heat, steam, boiling or similar means.
- Clean only with the solutions listed in this manual.
WARNING: Do not attempt to remanufacture, recondition, or recycle the
Masimo W1 as these processes may damage the electrical components, potentially
leading to user harm.
CAUTION: Only perform maintenance procedures specifically described in
the manual. Otherwise, return the Masimo W1 for servicing.
CAUTION: To avoid permanent damage to the Masimo W1, do not use undiluted
bleach (5% – 5.25% sodium hypochlorite) or any other cleaning solution not
recommended.
Compliance Warnings
WARNING: Changes or modifications not expressly approved can void the
user’s authority to operate the equipment.
WARNING: The frequency bands of this device (2.4 GHz and 5.15 to 5.25
GHz) are only for indoor use, in accordance with international
telecommunication requirements.
WARNING: Do not incinerate the Masimo W1. The device contains a battery
that should be properly disposed according to local laws and regulations.
WARNING: To help mitigate cybersecurity concerns, consider the following:
- Deactivating the Masimo W1 Bluetooth when not compatible or uncertain of the security of the Bluetooth connection.
- Do not wirelessly connect Masimo W1 with software not authorized for use by Masimo.
- Check the paired connection is made with the correct device.
- Connect the Masimo W1 to a Masimo smart device application so that data can be stored and kept.
CAUTION: Comply with local laws in the disposal of the device.
CAUTION: Keep Masimo W1 away from electrical equipment that emits radio frequencies to minimize radio interference. Radio interference may result in no or inaccurate readings.
Note: This equipment has been tested and found to comply with the Class B limits in accordance with EN 60601-1 2: 2015. These limits are designed to provide reasonable protection against harmful interference in all establishments, including domestic establishments.
Note: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note: Masimo W1 and Masimo W1 Wireless Charger are exempt from FCC and IC RSS 102 RF radiation exposure testing requirements set forth for an uncontrolled environment.
Note: When using Masimo W1 and consideration should be taken to local government frequency allocations and technical parameters to minimize the possibility of interference to/from other wireless devices.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
Risks and Benefits
See the Benefits and Risks of the Masimo W1 below.
Risks
- Inappropriate use or misuse of the device. You should follow the information provided in this manual and not self diagnosis or treat yourself. Always seek the advice of your physician if you are not feeling well.
- With electrical devices, there may be a risk of electrical hazards. These risks are reduced by the design and testing of Masimo W1.
- As with all devices with small parts, there is a risk of a child swallowing and choking. Keep small parts away from small children to prevent such hazards.
- As with all items applied directly to the skin, there is a risk of skin irritation and discomfort.
Benefits
- Masimo W1 is a wearable device able to provide clinically validated continuous oxygen saturation (SpO2) and pulse rate (PR).
- Masimo W1 can provide heart rate (HR) health data.
- Masimo W1 provides wireless communication capabilities to support storage and review of data from a connected smart device
Description
This chapter contains the description of the Masimo W1 physical features.
General Description
The Masimo W1 includes the following:
- Masimo W1 Device
- Masimo W1 Wireless Charger
For a complete list of compatible accessories, visit www.masimo.com.
Features
Top
- Main Menu/Back Button
- Press and hold to turn the watch Off. When Off, press once to turn the watch On.
- From the watch face, press once to view the Main Menu OR to navigate backwards when viewing setting menus and other screens.
- **Live Screen Button***
- From the watch face, press once to view the live health data screen. Screen returns to the watch face after a few moments of inactivity.
- From the watch face, press two times to turn off the screen.
- Press once to return to the watch face when viewing setting menus and other screens.
- Touch Screen
- Used to interact with the watch. See Using the Touch Screen on page 10.
- Top Electrode
- Electrode provided on the top and bottom bezels to be contacted with the fingers during HR health data measurements.
- Press and hold both buttons to reboot the watch.
Bottom
- Bottom Heart Rate Electrode
- Electrode on the bottom of the Masimo W1 that contacts the wrist for HR health data measurements.
- Optical Pulse Oximeter Sensor
- Location of sensors for Vitals measurements.
- Wrist M-band release button
- Press inward to remove the wrist M-band (watchband). Serial number and compliance information are located in the
recesses behind the wrist M-band.
- Press inward to remove the wrist M-band (watchband). Serial number and compliance information are located in the
Basic Setup and Use
The following steps are for the basic setup and use for operating the Masimo W1 watch
Charge the Watch
Before using Masimo W1, fully charge the battery.
Note: Use only a Masimo authorized charger when charging Masimo W1. The Masimo W1 will come with one of the wireless chargers shown, but not both.
-
Plug the wireless charger into a USB power source.
-
Place the bottom of the Masimo W1 on the compatible wireless charger base so that it is seated flush to begin charging.
Note: The Masimo W1 may need to be connected to other side of the base if it does not sit flush. -
Look for the “charging screen” to ensure the Masimo W1 is seated properly on the base.
Turn the Watch On
To turn the Masimo W1 on, press and hold the top button until the watch turns On. To turn off, press and hold the top button again until the watch turns Off.
Download the Masimo Health App
The Masimo Health App collects and displays health data from the Masimo W1 and
other paired devices.
Download the Masimo Health App directly from the Google Play or Apple App
Store and follow the setup instructions.
Masimo Health is required to support software updates to the Masimo W1 watch.
This prevents unauthorized upgrades to the Masimo W1.
Pair Masimo W1 to Masimo Health App
Pair Masimo W1 to the mobile device to view data from the watch on the Masimo Health App.
To pair the watch, from the Devices screen on the Masimo Health app, choose
Add Device.
Click on Masimo W1 under the Select a Device screen and follow the
instructions for pairing the watch to the mobile device.
Note: The connection needs to be confirmed to complete the pairing
process.
Put on the Watch
-
Place the watch with the screen facing up, on a flat part of the wrist avoiding the wrist bone (A).
The buttons should be towards your hand. -
Tighten the strap so the watch does not slip and then tighten the watch 1 to 2 more notches so that it does not slide but is comfortable.
Note: The watch has an indicator if the wrist M-band is too loose. See Watch Status Screen on page 13 for wrist M-band status.
Note: Make sure the bottom of the watch is fully touching the wrist and does not slide back and forth.
Note: Remove the watch before swimming, bathing or similar activities.
Using the Touch Screen
When interacting with the watch, use the following gestures to navigate the touch screen.
Touch/Tap – Momentarily touch and release one finger on the screen.
Touch and Hold – Touch and hold an item on the screen.
Swipe – Touch and move one finger on the screen left, right, up
or down.
Turn On Health Data
The continuous health data can be activated by selecting the Vitals icon and following the steps below. The Vitals icon can be found from either the Main Menu or the Watch Status screen. See Main Menu on page 12 or Watch Status Screen on page 13.
- Select the Vitals icon to activate the Continuous Health Data.
- Check the bottom of the watch makes good contact with the top of your wrist.
- Check the watch is secured comfortably to prevent it from slipping (1 or 2 notches tighter after it no longer slides on the wrist).
To view the Live Health Data screen, swipe right across the watch face using
one finger or press the lower button on the side of the Masimo W1.
Swipe up and down (1) using one finger to navigate the Live Health Data screen
and view all available health data.
See Live Health Data (Vitals) Screen on page 10 for complete information about the Live Health Data screen.
Live Health Data (Vitals) Screen
The Live Health Data (Vitals) screen contains the following information:
-
Health Data (Vitals)
When Vitals are enabled, Health Data displays*. If Vitals are not enabled, the option to Start Vitals displays. See Turn On Health Data on page 10. -
Waveform and Signal Quality Indicators
See Waveform and Signal Quality Indicators on page 11 for information. -
View Additional Screens
Swipe up/down to view additional screens that display more vitals measurements as well as activity data (daily step count, calories burned, and miles walked on this date). Activity data resets daily.
- Touch and hold a Vitals measurement to show information about that measurement.
Watch Face
The Watch Face displays Date, Time, Daily Step Count, and *Health Data (Blood Oxygen Content (SpO2/%), and Pulse Rate (PR/bpm)).
See Change Watch Face on page 14 to display a different face design.
- Displays when Vitals is enabled. See Turn On Health Data on page 10.
Note; The watch face may be difficult to view when in direct sunlight.
Waveform and Signal Quality Indicators
Signal IQ (SIQ) indicators are displayed as vertical bars (1) within the Pleth
Waveform (2) for each individual pulsation.
The height of the bar provides an assessment of the confidence in the SpO2
measurement displayed.
Low Confidence Indicator
When confidence in the displayed measurement is low, the reading is dimmer (1) than the others (SpO2 measurement shown, others similar).
Take a Heart Rate Measurement
The Heart Rate Measurement can be accessed by touching the Heart Rate icon from the Main Menu and following the steps below. See Main Menu on page 12. Ensure the Masimo W1 is on the wrist identified in the Orientation settings to ensure a proper Heart Rate measurement. See Watch Settings Options and Information on page 12.
- Access the Heart Rate measurement screen by touching the Heart Rate icon from the Main Menu.
- Check that the electrode pad on the bottom of the watch makes good contact to the wrist.
- Place your thumb on the electrode pad on the lower bezel (below the lower portion of the watch screen) and index finger on the upper bezel (above the upper portion of the watch screen) until the results screen is displayed.
Note: Do not move during the Heart Rate measurement. The measurement will take approximately 30s.
Advanced Use
The following information are for the additional features available that go beyond the basic set up and use
User Interface (Display)
Main Menu
The Main Menu displays a list of available apps.
- To open the Main Menu, swipe left or right across the watch face using one finger until the screen displays or press the upper button on the side of the Masimo W1.
- Open an app by tapping on its icon
Vitals Measurement * – Feature to start or stop health data measurements. See Turn On Health Data on page 10.
Watch Face Settings – Feature to change watch face. See Change Watch Face on page 14.
Heart Rate Measurement – Feature to perform a heart rate spot check. See Take a Heart Rate Measurement on page 11.
Settings Menu – Access watch settings and information. See Watch Settings Options and Information on page 12.
- The Vitals icon background color changes when active.
Watch Settings Options and Information
The following setting are available through the Main Menu.
Hydration Index| Manual or scheduled Hydration Index reset. The
Hydration Index can be reset manually or at a scheduled time.
---|---
Brightness| Screen brightness can be adjusted from the Brightness
screen. Default brightness is 7. Touch to select a brightness level from 1
(dim) to 10 (most bright).
Note: A high brightness setting may reduce battery life.
Always On| Always On displays the screen even when your wrist is down.
When your wrist is raised, all functions of the Masimo W1 are available. This
feature is turned on or off from the Always On screen.
Note: When this feature is enabled, battery life my be reduced.
Raise to Wake| The Raise to Wake feature sensitivity can be set to
Low, Medium or High (On), or turned Off. Default setting is Medium.
- When On, the screen turns on when your wrist is raised. When your wrist is lowered, the screen turns off. If the Masimo W1 does not wake when raised, check that the correct wrist orientation is selected. See Orientation.
- When Off, to view you must touch the screen or press one of the buttons on the Masimo W1. If the Masimo W1 does not wake when the screen is touched or buttons are pressed, the battery may need to be charged.
Note: A High sensitivity may shorten battery life. A low sensitivity or
turning this feature Off may extend battery life.
Note: This feature is disabled during the set hours when Bedtime is
enabled.
Vibration| Vibration is turned on or off from the Vibration screen.
When on, a vibration is felt when notifications are displayed on the Masimo
W1.
Bedtime| The Bedtime screen is used to Turn Bedtime On or Off and set
the Bedtime START and Bedtime END. This disables the Raise to Wake feature of
the Masimo W1 during the set time.
Set Time and Date| When connected to the Masimo Health app, the time and
date for Masimo W1 are automatically set. The time or date can also be set
manually. Touch the Edit Time or Edit Date tile to manually set the
time or date.
Orientation| By default, the Masimo W1 is set to be worn on the left
wrist. To set the watch to be worn on the right wrist, selection Right
from the options available on the Orientation screen.
Note: Orientation setting can affect the Raise to Wake feature
operation.
Step Sensitivity| Step sensitivity for the step counter can be set to
Low, Medium or High. Default setting is Low.
Note: A High step sensitivity may shorten battery life.
Bluetooth| Bluetooth is turned “On” or “Off” from the Bluetooth
screen. Bluetooth is On by default. When Bluetooth is off, Masimo W1 will not
communicate with the Masimo Health App to share Health Data.
Line Frequency| Line frequency for the Heart Rate measurement can be set
to 50Hz or 60Hz. Default setting is 60Hz.
About| Displays software and regulatory information about watch. Serial
number and compliance information are also located behind recess for the wrist
M-band.
Watch Status Screen
To view the Watch Status screen, swipe downward on the watch face with one
finger, or press the bottom button on the watch.
Touch an icon to view status or access settings.
| Battery Level| Battery level in percentage displays on the Watch Status
screen. When battery charge is low, a notification displays
---|---|---
| Bluetooth Status|
|
|
|
| Vibration Mode| Touch the icon to display the Vibration screen. This feature
can be turned on or off from the Vibration screen
| Bedtime Setting| Touch the icon to display the Bedtime screen and change the
settings. See Watch Settings Options and Information on page 12 for complete
information.
| Health Data| Touch the icon to display the Vitals screen. Vitals can be
started and stopped from this screen. See Turn On Health Data on page 10.
| Wrist M-band
Tightness|
Undetermined
|
Correct
|
Too Loose
|
Too Tight
Change Watch Face
To change the Masimo W1 face, open the Main Menu. See Main Menu on page 12.
- Touch the Watch Face Icon.
- Swipe left or right on watch face with one finger to choose a new watch face.
- When the desired watch face displays – stop swiping, this is now the watch face.
Appendix
Troubleshooting Masimo W1
Troubleshooting Masimo W1
Error | Possible Causes | Recommended Solutions |
---|---|---|
Masimo W1 does not turn on | · Low battery |
· Masimo W1 internal error.
|
- Charge the battery. See Charge the Watch on page 9.
- If problems persist, contact Masimo Support. See Contacting Masimo on page 19.
Masimo W1 does not charge.| The charger is not properly connected.|
- Check that the charger cable is properly connected to the USB Power Adapter.
- Check that the USB Power Adapter is plugged into the power outlet completely.
Poor connection between Masimo W1 and the charger.|
- Ensure no objects or foreign material is between the Masimo W1 and the charger.
- Ensure the back of the Masimo W1 is clean.
Masimo W1 internal error.|
- Restart the Masimo W1 by pressing and holding both side buttons for at least 15 seconds.
- If problems persist, contact Masimo Support. See Contacting Masimo on page 19.
Masimo W1 is not connected to the app on the smart device.| App is incompatible with smart device.|
- Ensure the correct app is being used.
- Ensure the latest version of the app is installed.
Connection issues between Masimo W1 and smart device.|
- Check that Masimo W1 Bluetooth is on.
- Check that Masimo W1 has been paired through the App and not just the smart device Bluetooth settings. See Pair Masimo W1 to Masimo Health App on page 9.
- Unpair and pair the Masimo W1 to the smart device again using the App. See Pair Masimo W1 to Masimo Health App on page 9.
- Restart the Masimo W1 by pressing and holding both side buttons for at least 15 seconds and retry the pairing procedure on the App. See Pair Masimo W1 to Masimo Health App on page 9.
Masimo W1 may be too far away from the smart device.| Move the Masimo W1
closer to the smart device and recheck connection.
Masimo W1 internal error.|
- Restart the Masimo W1 by pressing and holding both side buttons for at least 15 seconds and retry the pairing procedure on the App. See Pair Masimo W1 to Masimo Health App on page 9.
- If problems persist, contact Masimo Support. See Contacting Masimo on page 19.
Vitals measurements display as dashes “–“.|
- Readings may not have stabilized.
- Masimo W1 may not be worn properly.
|
- Allow time for readings to stabilize.
- Check if blood flow to the arm/wrist is restricted.
- Check that Masimo W1 is worn properly and that the watchband is tight. See Watch Status Screen on page 13.
Cannot perform Heart Rate measurement|
- Masimo W1 may not be worn properly.
- Excessive movement during measurement.
- Finger is placed incorrectly on the top electrode pad.
- Finger not held on the top electrode long enough.
|
- Ensure Masimo W1 is worn properly on the wrist. See Put on the Watch on page 10.
- Ensure the finger makes good contact with the bottom side of the bezel of the Masimo W1. See Take a Heart Rate Measurement on page 11.
- Hold finger steady for 30 seconds to process the measurement.
The following messages may appear on Masimo W1.
Message | Possible Causes | Recommended Solutions |
---|---|---|
Device Overheated, Watch needs to cool down before using. | Internal | |
temperature safety limit reached. |
- Remove from charger.
- Restart the Masimo W1 by pressing and holding both side buttons for at least 15 seconds.
- If problems persist, contact Masimo Support. See Contacting Masimo on page 19.
Something went wrong. Contact Masimo for further assistance.| Internal error.|
- Restart the Masimo W1 by pressing and holding both side buttons for at least 15 seconds.
- If problems persist, contact Masimo Support. See Contacting Masimo on page 19.
Specifications
Display Range and Resolution
Measurement | Display Range | Resolution |
---|---|---|
Oxygen Level (SpO2) | 0% to 100% | 1 % |
Pulse Rate (PR) | 25 bpm to 240 bpm | 1 bpm |
Pi (Perfusion Index) | 0.02 to 0.99 | 0.01 |
1.0 to 9.9 | 0.1 | |
10 to 20 | 1 | |
PVi (Pleth Variability Index) | 0 to 100 | 1 |
Pulse Rate Variability (PRV) | 0 ms to 150 ms | 1 ms |
HR (Heart Rate) | 25 bpm to 240 bpm | 1 bpm |
Hydration Index (Hi) | -5.0 to +5.0 | 0.1 |
The Masimo W1 includes LEDs that emit wavelengths in range of 500 nm to 1000 nm with a peak optical power less than 20 mW. This information about the wavelength range may be more useful for your healthcare professional.
*Oxygen Level Accuracy (ARMS)**
Parameter | Specification |
---|---|
SpO2 (No Motion) [1] (Low Perfusion) [2] | 2% A RMS, over the range 70% to |
100% for Adults
Pulse Rate (No Motion)| 3 bpm A RMS, over the range of 25 bpm to 240 bpm for
Adults
- ARMS accuracy is a statistical calculation of the difference between device measurements and reference measurements. Approximately two-thirds of the device measurements fell within +/- ARMS of the reference measurements in a controlled study.
**HR Accuracy (ARMS)***
Heart Rate (HR)
Range of 25 bpm to 240 bpm| ≤ 5 bpm
- ARMS accuracy is a statistical calculation of the difference between device measurements and reference measurements. Approximately two-thirds of the device measurements fell within +/- ARMS of the reference measurements in a controlled study
Physical Characteristics
Physical Characteristics
Watch Face Size| 40 mm (1.57”)
Weight with Watchband| 54 g (1.9 oz.)
Display Type| 16 bits color display with brightness adjustment
Expected Service Life| 3 Years
Protection against harm from solid and liquid ingress| IP24, Protected from
objects greater than 12 millimeters and water spray from any direction.
Electrical
Battery
Type| Internal Li-ion rechargeable
Capacity| Approx. 22 hrs. [3]
Charge Time| 3 hrs. [4]
Environmental
Environmental Conditions
Operating Temperature| 0°C to 35°C (32°F to 95°F)
Storage/Transport Temperature| -20°C to 60°C (-4°F to 140°F) [5]
Operating Humidity| 10% to 95% RH (non-condensing)
Storage/Transport Humidity| 10% to 95% RH (non-condensing)
Operating Atmospheric Pressure| 540 mBar to 1060 mBar
Compliance
Masimo W1 Safety Standards Compliance
IEC 60601-1| IEC 60601-1-2
EN ISO 80601-2-61| IEC 60601-1-11
Wireless Specifications
Communication (Bluetooth)
Type| BLE
Frequency| 2402-2480 MHz
Max Peak Output Power| -3.6dBm or 0.44mW (Conducted)
Antenna Peak Gain| +3dBi
Radio Compliance
Radio Modes| Bluetooth LE
USA| Model: W1
FCC ID: VKF-MASIW1
Model: Masimo Wireless Charger FCC ID: VKF-MASIW1CG
Guidance and Manufacturer’s Declaration
Electromagnetic Emissions
Equipment is intended for use in the electromagnetic environment specified
below. The customer or the user of the ME Equipment should assure that it is
used in such an environment.
Emission Test| Compliance| Electromagnetic Environment –
Guidance
RF Emissions CISPR 11| Group 1| Equipment uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are not likely to cause
any interference in nearby electronic equipment.
RF Emissions CISPR 11| Class B| Equipment suitable for use in all
establishments including domestic establishments.
Electromagnetic Immunity
Equipment is intended for use in the electromagnetic environment specified
below. The customer or the user of the Equipment should assure that it is used
in such an environment.
Immunity Test| IEC 60601 Test Level| Compliance Level|
Electromagnetic Environment – Guidance
Electrostatic discharge (ESD) IEC 61000-4-2| +6 kV contact +8 kV air| +6 kV
contact
+8 kV air| Floors should be wood, concrete or ceramic tile. If floors are
covered with synthetic material, the relative humidity should be at least 30%.
Power frequency (50/60 Hz) magnetic field IEC 61000-4-8| 30 A/m| 30 A/m| Power
frequency magnetic fields should be at levels characteristic of typical
location in a typical hospital environment.
Radiated RF IEC 61000-4-3| 10 V/m 80 MHz to 2.7 GHz| 10 V/m| Portable and
mobile RF communications equipment should be used no closer to any part of the
Masimo W1, including cables, than the recommendation separation distance
calculated from the equation applicable to the frequency of the transmitter.
Electromagnetic Immunity
Note 1 : At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2 : These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Equipment is used exceeds the applicable RF compliance level above, the Equipment should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Equipment.
Test Specifications for Enclosure Port Immunity to RF Wireless Communication Equipment
Test Frequency (MHz)| Band (a) (MHz)| Service (a)|
Modulation (b)| Maximum Power (W)| Distance (m)| Immunity
Test Level (V/m)
---|---|---|---|---|---|---
385| 380-395| TETRA 400| Pulse modulation (b)
18 Hz| 1.8| 0.3| 27
450| 430-470| GMRS 460, FRS 460| FM (c)
+/- 5 kHz deviation 1 kHz sine| 2| 0.3| 28
710| 704-787| LTE Band 13, 17| Pulse modulation (b)
217 Hz| 0.2| 0.3| 9
745
780
810| 800-960| GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5| Pulse
modulation (b)
18 Hz| 2| 0.3| 28
870
930
1720| 1700-1990| GSM 1800; CDMA 1900; GSM 1900; DECT; LTE Band 1, 3. 4. 35:
UMTS| Pulse modulation (b)
217 Hz
| 2| 0.3| 28
1845
1970
2450| 2400-2570| Bluetooth, WLAN, 802.11 b/g/n, RFID 2450, LTE Band 7| Pulse
modulation (b)
217 Hz| 2| 0.3| 28
5240| 5100-5800| WLAN 802.11 a/n| Pulse modulation (b)
217 Hz| 0.2| 0.3| 9
5500
5785
(a) For some services, only the uplink frequencies are included.
(b) The carrier shall be modulated use a 50% duty cycle square wave signal.
(c) As an alternative to FM modulation, 50% pulse modulation at 18 Hz may be used because while it does not represent actual modulation, it would be worst case.
Recommended Separation Distances
Recommended separation distances between portable and mobile RF communications equipment and the Masimo W1.
Rated maximum output power of transmitter [W]| Separation distance
according to frequency of transmitter [m]
80 MHz to 2.7 GHz
0.01| 0.06
0.1| 0.19
1| 0.6
10| 1.9
100| 6
For transmitters rated at a maximum output power not listed above, the
recommended separation distance d in meters (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the
transmitter manufacturer.
Note: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Symbols
The following symbols may be found on the Masimo W1, or packaging and are defined below.
Symbols | Definition | Symbols | Definition |
---|
| Follow Instructions for use|
| Consult instructions for use
| Federal Communications Commission (FCC) licensing| | Separate collection for
electrical and electronic equipment (WEEE)
| Identifies unit has been registered as a radio device| | Protected from
objects greater than 12 millimeters and water spray from any direction.
| Date of Manufacture YYYY-MM-DD| | Manufacturer
| Catalog number (model number)| | Serial number
| Lot Code| | Storage temperature range
| Atmospheric pressure limitation|
| Storage humidity limitation
| No parameter alarms| | Bluetooth
| Battery| –| —
| Instructions/Directions for Use/Manuals are available in electronic format
@http://www.Masimo.com/TechDocs
Note: eIFU is not available in all countries.
Citations
- SpO2 performance has been validated for no motion accuracy in human blood studies on healthy adult male and female volunteers with light to dark pigmented skin in induced hypoxia studies in the range of 70%-100% against a laboratory co-oximeter.
- SpO2 performance has been validated under low perfusion (≤ 0.3 perfusion index) accuracy in human blood studies on healthy adult male and female volunteers with light to dark pigmented skin in induced hypoxia studies in the range of 70%-100% against a laboratory co-oximeter.
- This represents approximate run time with Screen on-time: 0%, Bluetooth connection On, Active Measurement, SpO2 and Heart Rate (Continuous Vitals On), Heart Rate (10 Spot-Check measurements), using a fully charged battery.
- The battery shall charge to 80% of battery capacity in no longer than 3 hours at ambient temperature and might not charge completely under elevated ambient temperature.
- If the batteries are to be stored for extended periods of time, it is recommended that they be stored between -20°C to +30°C, and at a relative humidity less than 85%. If stored for a prolonged period at environmental conditions beyond these limits, overall battery capacity may be diminished, and lifetime of the batteries may be shortened.
Cleaning, Disinfecting and Service
The following chapter contains information about cleaning, battery operation, performance verification, service, repair, and warranty.
Cleaning Masimo W1 and Charger
CAUTION: Do not immerse Masimo W1 in any liquid.
The surfaces of Masimo W1 have been tested to be chemically resistant to the
following disinfectants/solutions:
- 70% Isopropyl Alcohol
- CaviWipes™
To clean Masimo W1, follow the instructions below:
- Use a soft-bristle, nylon brush wet with DI water and gently brush along the grooves and crevices of the body to loosen debris before cleaning.
- Use one CaviWipe or a 4” x 4” gauze pad saturated with 70% IPA to wipe the surfaces twice or until the surfaces are free of any visible residue.
- Use a second soft-bristle, nylon brush with thin brush head wet with 70% IPA and gently brush along the grooves and crevices of the body at least twice.
- Use a second CaviWipe or a second 4” x 4” gauze pad saturated with 70% IPA to wipe the surfaces twice or until the surfaces are free of any visible residue.
- When using CaviWipes, use a 4” x 4” gauze pad saturated with DI water to wipe the surface once.
- Allow the Masimo W1 device to dry thoroughly before using again
CAUTION : Never saturate Masimo W1 completely with any disinfection solution.
Service and Return Procedure
Contact Masimo for product support. If needed, an RMA will be provided for repair or replacement. Masimo can be reached at 800-326-4890. For customers outside the United States, local contact information can be found at http://service.masimo.com.
Clean contaminated/dirty equipment before returning per Maintenance and Cleaning instructions. Make sure the equipment is fully dry before packing. Package the device securely, in the original shipping box if possible, and enclose the following information and items:
- Include the RMA form provided, or a letter describing in detail any difficulties experienced with Masimo W1. Include the RMA number in the letter.
- Warranty information, a copy of the invoice or other applicable documentation must be included. Purchase Order number to cover repair if the device is not under warranty, or for tracking purposes if it is.
- Ship-to and bill-to information. Person (name, telephone/Telex/fax number and country) to contact for any questions about the repairs.
- A certificate stating that the device has been decontaminated for bloodborne pathogens.
- Return the device to Masimo at the address listed in Contacting Masimo on page 19 below.
Contacting Masimo
Masimo Corporation
52 Discovery
Irvine, California 92618
Tel:+1 949 297 7000
Fax:+1 949 297 7001
Limited Warranty
Masimo warrants to the original end-user purchaser the Masimo-branded hardware
product Masimo W1 and any software media contained in the original packaging
against defects in material and workmanship when used in accordance with
Masimo’s user manuals, technical specifications, and other Masimo published
guidelines for a period of 36 months from the original date the Product was
obtained by the end-user purchaser.
Masimo’s sole obligation under this warranty is the repair or replacement, at
its option, of any defective Product or software media that is covered under
the warranty.
To request a replacement under warranty, Purchaser must contact Masimo and
obtain a returned goods authorization number so that Masimo can track the
Product. If Masimo determines that a Product must be replaced under warranty,
it will be replaced and the cost of shipment covered. All other shipping costs
must be paid by purchaser.
Exclusions
The warranty does not apply to any non-Masimo branded product or any software, even if packaged with the Product, or any Product that was: (a) not new or in its original packaging when supplied to purchaser; (b) modified without Masimo’s written permission; (c) supplies, devices, or systems external to the Product; (d) disassembled, reassembled, or repaired by anyone other than a person authorized by Masimo; (e) used with other products, like new sensors, reprocessed sensors, or other accessories, not intended by Masimo to be used with the Product; (f) not used or maintained as provided in the operator’s manual or as otherwise provided in its labeling; (g) reprocessed, reconditioned, or recycled; and (h) damaged by accident, abuse, misuse, liquid contact, fire, earthquake or other external cause. No warranty applies to any Product provided to Purchaser for which Masimo, or its authorized distributor, is not paid; and these Products are provided AS-IS without warranty.
Limitation of Warranty
Except as otherwise required by law or altered by the purchase agreement, the above warranty is the exclusive warranty that applies to the Product and software media, and Masimo does not make any other promises, conditions, or warranties regarding the Product. No other warranty applies, express or implied, including without limitation, any implied warranty of merchantability, fitness for a particular purpose, satisfactory quality, or as to the use of reasonable skill and care. See the licensing terms for the terms and conditions that apply to and Software accompanying the Product. Additionally, Masimo will not be liable for any incidental, indirect, special, or consequential loss, damage, or expense arising from the use or loss of use of any Products or Software. In no event shall Masimo’s liability arising from any Product or Software (under contract, warranty, tort, strict liability, or otherwise) exceed the amount paid by purchaser for the Product or Software. The above limitations do not preclude any liability that cannot legally be disclaimed by contract.
End-User License Agreement
This document is a legal agreement between you (“purchaser”) and Masimo Corporation (“Masimo”) for the purchase of this Product (“Product”) and a license in the included or embedded Software (“Software”) except as otherwise expressly agreed in a separate contract for the acquisition of this Product, the following terms are the entire agreement between the parties regarding your purchase of this Product. If you do not agree to the terms of this agreement, promptly return the entire Product, including all accessories, in their original packages, with your sales receipt to Masimo for a full refund.
Restrictions
-
Copyright Restrictions: The Software and the accompanying written materials are copyrighted. Unauthorized copying of the Software, including Software that has been modified, merged, or included with other software, or the written materials is expressly forbidden. Purchaser may be held legally responsible for any copyright infringement that is caused or incurred by Purchaser’s failure to abide by the terms of this Agreement. Nothing in this License provides any rights beyond those provided by 17 U.S.C. §117.
-
Use Restrictions: Purchaser may physically transfer the Product from one location to another provided that the Software is not copied. Purchaser may not electronically transfer the Software from the Product to any other instrument. Purchaser may not disclose, publish, translate, release, distribute copies of, modify, adapt, translate, reverse engineer, decompile, disassemble, or create derivative works based on the Software or the written materials.
-
Transfer Restrictions: In no event may Purchaser transfer, assign, rent, lease, sell, or otherwise dispose of the Product or the Software on a temporary basis.
Purchaser shall not assign or transfer this License, in whole or in part, by operation of law or otherwise without Masimo’s prior written consent; except that the Software and all of Purchaser’s rights hereunder shall transfer automatically to any party that legally acquires title to the Product with which this Software is included. Any attempt to assign any rights, duties or obligations arising hereunder other than as set forth in this paragraph shall be void. -
U.S. Government Rights: If Purchaser is acquiring Software (including the related documentation) on behalf of any part of the United State Government, the following provisions apply: the Software and documentation are deemed to be “commercial software” and “commercial computer software documentation,” respectively pursuant to DFAR Section 227.7202 FAR 12.212, as applicable. Any use, modification, reproduction, release, performance, display or disclosure of the Software (including the related documentation) by the U.S. Government or any of its agencies shall be governed solely by the terms of this Agreement and shall be prohibited except to the extent expressly permitted by the terms of this Agreement.
For general wellness and health applications including sports, fitness, and
relaxation management.
These operating instructions provide the necessary information for proper
operation of the Masimo W1 Health and Wellness. There may be information
provided in this manual that is not relevant for your Masimo W1. It is
recommended to read the instructions before operating Masimo W1.
See instructions for use for use information, including warnings, and precautions.
Wireless Radio:
Contains: FCC ID: VKF-MASIW1 | IC: 7362A-MASIW1 | Model: W1
Contains: FCC ID: VKF-MASIW1CG | IC: 7362A-MASIW1CG | Model: Masimo
Wireless Charger
Customer Support
Masimo Corporation
52 Discovery
Irvine, CA 92618, USA
Tel.: 1-949-297-7000
Fax.: 1-949-297-7001
www.masimo.com
Patents: www.masimo.com/patents.htm see http://www.masimo.com/patents – http://www.masimo.com/patents
Masimo®, SET®, Masimo W1®, and ® are federally registered trademarks of Masimo Corporation. M-band™ and SET+™ are trademarks of Masimo Corporation. Google Play and the Google Play logo are trademarks of Google LLC. App Store and App Store logo are registered trademarks of Apple Inc. The Bluetooth word mark and logo are registered trademarks owned by Bluetooth SIG, Inc.
© 2024 Masimo Corporation
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>