HYDRO-RAIN GC1 Gateway Controller Instruction Manual
- September 7, 2024
- HYDRO-RAIN
Table of Contents
GC1 Gateway Controller
“`html
Product Information
Specifications
-
Brand: Hydro-Rain
-
Model: Gateway Controller
-
Location: 915 Overland Street, North Salt Lake, UT 84054,
USA -
Contact: 888.203.1179
-
Website: www.HydroRain.com
Product Usage Instructions
Getting Started
Prior to installing the new Gateway Controller, ensure all parts
are intact and undamaged. Contact support if any parts are missing
or broken.
Part List
- 1x Gateway Controller
- 1x Screwdriver
- 2x Cable Gland
- 1x 10ft (3.3m) antenna cable
- 4x Mounting Screws
- 1x CR2023 Cell Battery
- 1x Accessory Adapter
- 1x Door Keys
Recommended Tools
- Level
- Miscellaneous Wire
- Power Drill
- Philips Screwdriver
- Wire Stripper
Controller Installation
Mounting Options
Attach the Gateway Controller to a pole, wall, or panel using
the provided screws and the mounting holes at the top and bottom of
the controller.
Mounting the Gateway Controller to a PoleMounting the Gateway Controller to a
Wall or
Panel
Helpful Hints
- A mini screwdriver is provided for low-voltage terminals.
- Remove knockouts with a flathead screwdriver.
- Insert the coil cell battery into the designated slot.
- Add accessories using the provided accessory adapter.
Connectivity Options
The app assists in configuring connectivity during setup:
-
Cellular: Slide the B-hyve Cell Module into
the slot. (Cell Module Sold Separately)Adding a Cell Module -
Wi-Fi: Ensure the Gateway Controller is within
Wi-Fi range of the router (typically 150 ft).Wi-Fi Setup
Note: 5150-5250MHz Wi-Fi connections are not available in
Canada if mounted outdoors.
Frequently Asked Questions (FAQ)
Q: Who should install the Gateway Controller?
A: The Gateway Controller must be installed by a trained
professional for proper setup and operation.
Q: How can I get help with setting up the Gateway
Controller?
A: Contact B-hyve Ag Product Support at
1-801-407-5255 for
assistance with installation and operation.
“`
GATEWAY CONTROLLER
INSTRUCTION MANUAL
888.203.1179 915 Overland Street, North Salt Lake, UT 84054, USA
www.HydroRain.com
CONTROLLER INSTALLATION & USER MANUAL
Welcome to the Hydro-Rain Family
Congratulations on the purchase of the Gateway Controller Time is money, so
Hydro-Rain products are designed to save you both. Whether it is programming a
controller, installing a device, or adjusting the system, Hydro-Rain products
are simply faster and easier to use.
The Gateway Controller must be installed by a trained professional.
B-hyve Ag
The B-hyve Ag app is designed for for both growers and dealers to easily
manage connected irrigation controllers, users, and accounts. Download the
B-hyve Ag app to get started.
Need Help?
Contact B-hyve Ag Product Support :
1-801-407-5255 For help setting up or
operating the Gateway Controller please call the Hydro-Rain Product Support
team. Our friendly staff is here to assist with all the technical needs of the
installer or maintenance crew.
01
Getting Started
Prior to installing the new Gateway Controller, make sure the the product is
intact and undamaged. If any parts are missing or broken please call
1-801-407-5255 as soon as possible.
Part List
1x Gateway Controller
1x Screwdriver
2x Cable Gland
1x 10ft (3.3m) antenna cable
4x Mounting Screws
1x CR2023 Cell
CR2032
Battery
1x Accessory Adapter
1x Door Keys
Recommended Tools
Level
Miscellaneous Wire
Power Drill
Philips Screwdriver
Wire Stripper
02
CONTROLLER INSTALLATION & USER MANUAL
Mounting Options
Using the mounting holes located at the top and bottom of the controller,
attach the unit to a pole, wall, or panel using the provided screws.
Pole
X2
Figure 1a. Mounting the Gateway Controller to a Pole
Wall/Panel
X4
Figure 1b. Mounting the Gateway Controller to a Wall or Panel
03
CONTROLLER INSTALLATION & USER MANUAL
Helpful Hints
Mini Screwdriver A mini screwdriver is provided to be used on the low-voltage
green terminals. It can be housed in the provided slot on the door.
Knockout The knockouts on the controller can easily be removed by inserting a
flathead screwdriver into the slot and rotating.
Bottom of Controller
Coil Cell Battery Insert the provided coil cell battery into the designated
slot on the Gateway Controller. Accessory Adapter An accessory adapter is
provided to allow B-hyve accessories to be added to the Gateway Controller.
There is no need to install the accessory adapter if accessories will not be
added.
Step 1: Remove the far-right knockout on the Gateway Controller. Step 2:
Connect the accessory adapter into the 4-pin receptacle. Step 3: Remove the
paper on the accessory adapter and insert the accessory adapter into the far-
right knockout.
05
Connectivity Options
The app will help you configure the connectivity during setup.
Cellular Slide the B-hyve Cell Module into the cell module slot. (Fig. 3)
(Cell Module Sold Separately. SKU: 04450)
Wi-Fi Ensure the Gateway Controller is within Wi-Fi range of the router,
typically 150 ft. (Fig. 4)
5150-5250MHz Wi-Fi connections are not available in Canada if mounted
outdoors.
~150 ft Max Range
CELL MODULE
Figure 3. Adding a Cell Module
Figure 4. Wi-Fi Placement
Ethernet Insert ethernet cable into the marked slot on the controller.
Client Radio Insert cable into the marked slot on the controller. (Client Radio Sold Separately) Requires AG-CPB (Sold Separately SKU: 25024)
STATUS BLUETOOTH
ETHERNET
Figure 5a. Ethernet Connection
Figure 5b. Client Radio Connection
06
CONTROLLER INSTALLATION & USER MANUAL
Wiring – Power Options Line Power
120VAC/220VAC Neutral Earth Ground Figure 6. Wiring the Gateway Controller –
Line Power
24VDC
Earth Ground
Figure 7. Wiring the Gateway Controller – 24VDC
GND 24VDC
07
Wiring – General
WARNING: TURN OFF THE POWER TO THE CONTROLLER BEFORE WORKING WITH THE
TRANSFORMER AND WIRING. TURNING THE ON/OFF SWITCH DOES NOT TURN OFF THE POWER
INTO THE TRANSFORMER. ALWAYS FOLLOW APPLICABLE ELECTRICAL CODES. ELECTRICAL
WORK MAY REQUIRE A LICENSED ELECTRICIAN.
Pump
Pump 1 Voltage (24VAC/120VAC/220VAC)
PUMP 1
Pump 2 Voltage (24VAC/120VAC/220VAC)
PUMP 2
Figure 8. Wiring – Pump
The Gateway Controller relays are rated for up to 220VAC, 10amps, and single
phase. For anything else, use a contactor.
Flow Meters
METER 1
METER 2
Figure 9. Wiring – Flow Meters
The Gateway Controller can read flow meters with a pulse output and has an 18V
pull-up on the signal input.
08
CONTROLLER INSTALLATION & USER MANUAL
Wiring – Transducers
Any combination of 0-10V or 4-20mA type transducers is acceptable.
Voltage
TRANSDUCER 1
TRANSDUCER 2
Figure 10. Wiring – Transducers – Voltage
The Gateway Controller accepts voltage inputs between 0-10VDC.
4-20mA
TRANSDUCER 1 Figure 11. Wiring – Transducers – 4-20mA
TRANSDUCER 2
09
Product Warranty
Hydro-Rain warrants to its trade customers that its products will be free from
original defects in material and workmanship (commencing on the date of sale
to the trade customer) for a period of three-years, or five, (for Premier
Contractors). For customers outside of the United States, this warranty may
vary by geographical location. If there are further questions about
installation, please contact Hydro-Rain via phone
1-888-493-7672 Monday-Friday MST from
7:00am to 7:00pm and Saturday-Sunday from 7 am to 5 pm. Or try our website,
www.hydrorain.com. This warranty applies only to Hydro-Rain products, which
are installed as specified and used as intended for commercial irrigation
purposes. The warranty applies only to offered products, which have not been
altered, converted, damaged, misused, or misapplied. This warranty does not
cover products adversely affected by the system into which the products are
incorporated, including improperly designed, installed, operated, or
maintained systems or systems using water containing corrosive chemicals,
electrolytes, sand, dirt, silt, rust, and scale. This warranty does not cover
component failure caused by lightning strikes, electrical power surges, or
damage caused by freezing environments. Hydro-Rain’s liability is limited to
the repair and/or replacement at Hydro-Rain’s sole discretion, of products
that are returned prepaid through the trade customer to the factory and found
by HydroRain to be defective, but in no event shall Hydro-Rain’s liability
exceed Hydro-Rain’s selling price of the product. Hydro-Rain makes no other
warranties, expressed or implied. No representative, agent, or distributor or
other persons have the authority to waive, alter, or add to the printed
provisions of this warranty, or make representation of warranty not contained
herein.
10
CONTROLLER INSTALLATION & USER MANUAL
FCC & IC Statement
This device complies with Part 15 of the FCC Rules and Industry Canada license
exempt RSS standards. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation. FCC Warning: Any changes or modifications not expressly
approved by the party responsible for compliance could void the user’s
authority to operate this equipment. Note: This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one of the following measures: · Reorient or
relocate the receiving antenna. · Increase the separation between the
equipment and the receiver. · Connect the equipment into an outlet on a
circuit different from that to which the receiver is connected. · Consult the
dealer or an experienced radio/TV technician for help This device meets the
FCC and IC requirements for RF exposure in public or controlled environments.
The end user is advised to maintain a distance of 20 cm from the controller
and any personnel to ensure compliance with RF exposure regulations. This
Class B digital apparatus complies with Canadian ICES-003
Déclaration de FCC et L’IC
Cet appareil est conforme à la section 15 de la Règlementation de la FCC et la
norme RSS d’Industry Canada. Son fonctionnement est soumis aux deux conditions
suivantes: (1) cet appareil ne doit pas causer d’interférences nuisibles, et
(2) cet appareil doit tolérer toutes les interférences, dont les interférences
pouvant causer un fonctionnement non désiré. Cet appareil numérique de classe
B est conforme à la norme canadienne ICES-003. Remarque: cet appareil été
testé et déclaré conforme aux limites d’exposition pour les appareils
numériques de classe B, selon la section 15 de la Règlementation de la FCC.
Ces limites sont conçus pour fournir une protection raisonnable contre les
interférences nuisibles dans une installation résidentielle. Cet appareil
produit, utilise et peut émettre de l’énergie radio fréquence et, si elle
n’est pas installée et utilisée conformément aux instructions, peut causer des
interférences nuisibles aux communications radio. Cependant, il n’est pas
garantie que des interférences ne se produisent pas dans une installation
particulière. Si cet appareil cause des interférences gênantes à la réception
d’un signal radio ou de télévision, ce qui peut être déterminé en allumant et
en éteignant l’appareil, l’utilisateur peut corriger les interférences en
suivants une des mesures suivantes : · Réorientez ou repositionnez l’antenne
de réception. · Augmentez la distance entre l’appareil et le récepteur. ·
Branchez l’appareil dans une prise sur un circuit différent du circuit sur
lequel le récepteur est branché. · Consulter le revendeur ou un technicien
radio/TV expérimenté pour obtenir de l’aide. Cet appareil est conforme aux
exigences de la FCC et de l’IC concernant l’exposition aux ondes dans un
environnement public ou contrôlé. Il est conseillé à l’utilisateur final de
maintenir une distance de 20 cm du contrôleur pour assurer la conformité aux
réglementations d’exposition RF. Information de conformité pour le Canada
11
Note: The LoRA function of this product has been software blocked, and
customers cannot use this function
12
EU & UK Declaration of Conformity
Gardena, Inc. North Salt Lake, UT 84054 USA Declares under our sole
responsibility, that the product:
GC1 Gateway Controller
Complies with the following:
European Directives 2014/53/EU with reference to the following standards: ETSI
EN & EN 300 220-1 V3.1.1 (2017-02) ETSI EN & EN 300 220-2 V3.2.1 (2018-06)
ETSI EN & EN 300 328 V2.2.2 (2019-07) EN 50665:2017 ETSI EN & EN 301 489-1
V2.2.3 (2019-11) ETSI EN & EN 301 489-3 V2.1.2 (2021-03) ETSI EN & EN 301
489-17 .2.4 (2020-09) EN 55032:2015/A11:2020, IEC & EN IEC
61000-3-2:2019/A1:2021 EN 61000-3-3:2013/A1:2019 EN 55035:2017/A11:2020 EN
60730-1:2016 EN 60730-2-7:2020
Specifications
Input 120VAC 0.6A OR 240VAC 0.3A; 50/60Hz Output 120VAC 0.6A OR 240VAC 0.3A; 50/60Hz IPX4 Rating
Temperature Operating: 32-131° F (0-60° C) Storage & transport: -14-158° F
(-10-70° C)
Humidity Operating Operating: 0-90% Storage & transport: 0-90%
Antenna
Manufacture: Seeed Technology Co., Ltd Part Number: 318020693 Gain: 8 dBi
Type: Dipole
Battery Specifications Controller requires a CR2032 Lithium battery (included) To insert a new battery, the positive (+) must be on the left and the negative (-) must `be on the right.
008 887 376
CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE BATTERY MANUFACTURER’S
INSTRUCTIONS.
WARNING: RISK OF FIRE, EXPLOSION, AND ELECTRIC SHOCK. REPLACE BATTERY WITH
CR2032 ONLY. USE OF A DIFFERENT BATTERY HAS THE POTENTIAL FOR A RISK OF FIRE,
EXPLOSION, AND ELECTRIC SHOCK.
WARNING: DO NOT INGEST BATTERIES. CHEMICAL BURN HAZARD. KEEP BATTERIES AWAY
FROM CHILDREN.
WARNING: THIS PRODUCT CONTAINS A LITHIUM BUTTON/COIN CELL BATTERY.
WARNING: IF A NEW OR USED LITHIUM BUTTON/COIN CELL BATTERY IS SWALLOWED OR
ENTERS THE BODY, IT CAN CAUSE SEVERE INTERNAL BURNS AND CAN LEAD TO DEATH IN
AS LITTLE AS 2 HOURS.
WARNING: BATTERY MUST BE REMOVED FROM THE CONTROLLER BEFORE IT IS SCRAPPED.
13
888.203.1179 915 Overland Street, North Salt Lake, UT 84054, USA
www.HydroRain.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>