Specifications:

  • Product Name: BPRO-PWR Power System

  • Model: THINK Height-Adjustable Workstation

  • UL Recognized as an Office Furnishing Accessory (UL 1286)

  • UL Listed as a Manufactured Wiring System (UL 183)

  • Compliance: National Electrical Code (NEC), municipal
    standards

  • Rated Quad Terminal: 50 amps

  • Positive locking connections with keyed terminal housings

Product Usage Instructions:

Installation:

The power system combines junction blocks, jumpers, and power
infeeds into one modular assembly. Power is routed through flexible
oval metal conduit for easy corner traversal. Ensure all
connections are positively locked by keyed terminal housings during
installation.

THINK Power System Overview:

The patented six-point contact terminal at the center of the
power system efficiently distributes power, reducing contact
resistance and providing a stable connection. The quad terminal is
rated at over 50 amps with built-in overload insurance.

Keying:

The keying system provides circuit configurations for different
setups. Ensure proper keying alignment for circuits to function
correctly.

Product Components:

  • Receptacle: 15 Amp Duplex PROR 1, 2, 3, & 4
  • Blocks: Single Block PROSB, Double Block PRODB
  • In-Line Power Block: PROBC
  • Jumper: M/M Adjustable Jumper PROJ 41, 46, 52, & 58
  • Power Infeed: Conduit Power Entry PROIF 72 & 144, New York
    Liquid Tight Power Infeed PROIFNYC

FAQ:

Q: Can this power system be used with any type of

workstation?

A: The power system is designed to be compatible with most
workstations. However, always ensure compatibility with your
specific workstation model before installation.

Q: What is the maximum amperage rating of the quad

terminal?

A: The quad terminal is rated at over 50 amps, providing ample
power capacity for various devices.

“`

BPRO-PWR
Power System
THINK Height-Adjustable Workstation
General Installation Guide

INTRODUCTION

THINK Power System Overview
Universally Recognized
The power system is UL Recognized as an Office Furnishing Accessory (UL 1286), and is UL Listed as a Manufactured Wiring System (UL 183) in full compliance with electrical specifications found in the National Electrical Code (NEC). It also complies with municipal standards such as New York, Los Angeles, and San Francisco.
Circuitry/Keying
The power system is rated for 20 amps allowing the use of 4 circuits with 4 line conductors, 2 neutrals and 2 grounds. Under NEC requirements, up to 13 duplex receptacles maybe used per circuit, with a total of 52 available receptacles if all circuits are used, per single power entry. The line conductors are 12 AWG, and share a 12 AWG ground and a 10 AWG neutral. The fourth circuit is isolated and dedicated, and is serviced by its own line conductor, neutral and isolated ground. Alternate circuit diagrams are available. The power system can be wired in both single and three-phase configurations, 240/120V, 208/120V respectively. Additionally, a 3 hot, 3 neutral, 2 ground (3-3-2) wiring system is available
Flexibility
The practical design of the power system combines junction blocks, jumpers, and power infeeds into one modular assembly. Power is routed through the extremely flexible oval metal conduit, which makes traversing sharp corners easy.
Installation
All connections are positive locking, assured by keyed terminal housings.

THINK POWER SYSTEM

Contact
The center of the power system is the patented six-point contact terminal. The quad terminal is rated at over 50 amps, offering built-in overload insurance. The design efficiently distributes power, reducing the contact resistance. The six points of contact provide a stable connection, eliminating rocking.

Keying 3+D

Circuit 1 Circuit 2 Circuit 3 Circuit 4

N2 N1 ISO G G H4 H3 H2 H1
Circuit 1 Circuit 2 Circuit 3

N1 N2 N3 G ISO G H1 H2 H3
1

Receptacle

15 Amp Duplex PROR 1, 2, 3, & 4

Blocks

Single Block PROSB

In-Line Power Block PROBC

Jumper

Power Infeed

New York Power Entry

Double Block PRODB
M/M Adjustable Jumper PROJ 41, 46, 52, & 58
Conduit Power Entry PROIF 72 & 144
New York Liquid Tight Power Infeed PROIFNYC
2

END OF THINK POWER SYSTEM SECTION

1-866-999-0955 | hello@juniperoffice.com | juniperoffice.com © 2023 Juniper Office | Version 23.0.0

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals